Concrete Core test at Lab

Поделиться
HTML-код
  • Опубликовано: 16 окт 2024

Комментарии • 162

  • @fajju247
    @fajju247 2 года назад +3

    Without capping to core is wrong procedure ref
    IS 516 part 4 2018
    And correction factor formula is give
    F=0.11N+ 0.78
    Where N is hight / diameter ratio.
    Graph 📈 is in old IS 516- 1959

  • @akhileshverma9823
    @akhileshverma9823 2 года назад +1

    aap bahut hi excellent kam kar rahe h sir... 🙏🙏

  • @HariKrishnan-wp9zp
    @HariKrishnan-wp9zp Год назад

    You're very good and extrimily best explanation good job thankful to you

  • @rohitgarhwal2759
    @rohitgarhwal2759 3 года назад +1

    Very good vedeo Very informative and helpful

  • @dipupal9215
    @dipupal9215 Год назад

    Nice video sir.
    Ap bahut acha samjhate h

  • @mohammadfarhan368
    @mohammadfarhan368 2 года назад +1

    Good but what if there are steel bars in the core sample? what is the factor (FReinf) for steel bars...Plz

  • @vivekbhoi8549
    @vivekbhoi8549 3 года назад +4

    Nice video, Very informative and easy understandable 👍

  • @sanketjathar9513
    @sanketjathar9513 2 года назад +1

    is this ok to have a steel in concrete core while testing and if its ok then what is based used for this by yours side. Please give us a knowledge about in brief.

  • @AMOLJADHAV-nu1bb
    @AMOLJADHAV-nu1bb 2 месяца назад

    What is the 1.25 ..? And why..? Please explain..

  • @Blogcompany_New
    @Blogcompany_New 2 года назад +1

    Sir MORTH me likha hai ki Dia 150 mm se km nhi hona chahiye section 900 me diya hai MORTH me

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 года назад

      Dear, Minimum diameter of greater of three times the maximum nominal size of the coarse aggregate or 50 mm,
      Diamond segmented core bit in Hilti ,
      Size - 50 mm to 600 mm dia & length 300 mm to 2000 mm
      I hope cleared this issue.

  • @sasankasekhar9735
    @sasankasekhar9735 3 года назад +6

    you just applied two correction factors..one is L/D & other is equivalent cibe strength...but there is another according to IS code & which is dia correction factor, for this it will be multiplied by 1.03 for dia more than 75 mm

    • @sasankasekhar9735
      @sasankasekhar9735 3 года назад +1

      Also there is acceptance for avg. of three cubes 85% of Fck & individual it will be more than 75% of Fck...

    • @qureshiniyazahmed6492
      @qureshiniyazahmed6492 2 года назад

      On which page number, dia. Correction factor is mentioned..plz state.

  • @Fahad-471
    @Fahad-471 2 года назад

    Very knowledgeable video Sir
    Thank you so much for sharing knowledge

  • @saiprakashraju1253
    @saiprakashraju1253 3 года назад +2

    what about steel inside, you take still also, so strength had came more....in cube at the time of concrete inside no steel, kindly explain.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +2

      Due to the steel coming inside the core, its strength decreases because it gets a voids of core sample..

  • @deepakkatkar1378
    @deepakkatkar1378 2 года назад +1

    Nice explanation, superrr

  • @mdangwal84
    @mdangwal84 3 года назад +2

    Very informative video sir

  • @himanshupal3731
    @himanshupal3731 2 года назад

    Thank you sir itni jankari dene ke liye bahut achh lga pura vedio smjhh aa gaya
    Sir cub ki strength persentage me kaise calculate krte hai iska ek vedio bna dijiye 🙏

  • @guddukumarsah-h5n
    @guddukumarsah-h5n 5 месяцев назад +1

    Core cutting Kitna meter Mai karna chaiya

  • @prakashbarik46
    @prakashbarik46 2 года назад +1

    Thank you Sir for this Video... It's so helpful

  • @vamsireddy6032
    @vamsireddy6032 2 года назад

    Very good explanation sir

  • @nageshkallem3611
    @nageshkallem3611 Год назад

    U can't remove the steel how to strength achieve?

  • @pavankumaryadav4900
    @pavankumaryadav4900 2 года назад

    Thanks sir to share your best knowledge

  • @rajmaheta5330
    @rajmaheta5330 Год назад +1

    As per IS code individual sample Test also have minimum 75% of strength that is not matching

  • @DevenderSingh-vk6hp
    @DevenderSingh-vk6hp 2 года назад +5

    Strength of individual core shouldn't be less than 75% of fck I.e.18.75 but 2nd reading is 15.78mpa which is unacceptable

    • @Nanikikahaniya3
      @Nanikikahaniya3 3 месяца назад

      Yes,
      But sir jabarajasti pass krne pr tule h😅

    • @rajasthanengineers3309
      @rajasthanengineers3309 3 месяца назад

      Or isme cube strength ku nikale apn core ki strength dekh rahe hai na kuki m30 ki core strength 85 percent se kam na ho

  • @harvinders18
    @harvinders18 2 года назад

    Ssa bhaji … kya charge krte ho corecutting test ke

  • @tiktikboom4226
    @tiktikboom4226 Год назад +1

    Core capping is necessary as per is code.. without capping core likely to fail early..

  • @shankerkumardas7048
    @shankerkumardas7048 2 года назад

    correction factor=2 than cylinderical strength should be= strength X correction factor i.e- 19.14 x 2

  • @samrankhan1120
    @samrankhan1120 Год назад

    Sir sulfur capping must into both side...

  • @AbhishekSingh-xy7yv
    @AbhishekSingh-xy7yv 3 года назад +3

    Sir but according to one Clause.. individual cylindrical strength should not be less than 0.75 fck. Iska kya matlab hoga?

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +3

      Because actual compression strength of concrete core is taken as 0.85 times of specified cylindrical strength.
      cylindrical strngth is given by 0.85fck
      As per your question :- 0.75 fck,
      Fck :- characteristic strength of concrete.
      Yani ki 0.75 × 25 ( 25 Grade of Concrete)
      18.75 N/mm2 is individual strength but average strength not less than 0.85 fck
      0.85 × 25 :- 21.25 N/mm2..

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад

      Is per is code guidelines.. 👍👍

    • @subratkumaranayak6232
      @subratkumaranayak6232 Год назад

      Pls sir is code ka nam bata dijiye

    • @mohdubaish4636
      @mohdubaish4636 Год назад

      516

  • @bijanmaity3459
    @bijanmaity3459 2 года назад

    Sir this result is not appropriate for acceptation condition, because three cube result not under 15%.

  • @KumarP-tr8xe
    @KumarP-tr8xe 3 года назад +1

    Excellent video 👍

  • @Akash24274
    @Akash24274 3 года назад +1

    Very nice video sir 😊😊

  • @santoshnamdev1238
    @santoshnamdev1238 2 года назад

    Yadi core ke andar steel aa jata h to uska strength kse minus krte h sir

  • @jocks5176
    @jocks5176 Год назад

    i see your video and easy understable but you forget about tell individual strenth, i see in your video the 2nd sample is fail 15. something so you forget tell about individual calculation. thankyou sir, Im a QA/Qc Engg.

  • @amarpc3532
    @amarpc3532 3 года назад +1

    Dear sir how plz tell me how to set 140kg/cm 2 after conversation 5.13 in/sec how to do trail error method

  • @mohammedarif2368
    @mohammedarif2368 2 года назад

    Sir aap ne correction factory of reinforcement kase nikala plz batana

  • @numanakhtar8519
    @numanakhtar8519 2 года назад

    Sir cylinderical strength 85% hona chahiye na cube strength ka...

  • @CivilEngineeringbyAnkur
    @CivilEngineeringbyAnkur 3 года назад +2

    Which is code detemine cube strength multiple 5/4change of

  • @DharmendraKumar-gq4fc
    @DharmendraKumar-gq4fc 2 года назад +1

    Superb sir

  • @dineshahlawat5001
    @dineshahlawat5001 3 года назад +1

    Sir not showing Correct method of testing Core test ..
    where showing Capping in core for testing for surface in CTM testing machine

  • @Terminator616
    @Terminator616 2 года назад +1

    Should we make cube of 9.8 mm side or we compare with 150mm cube?

  • @Tukaram26
    @Tukaram26 2 года назад

    Very Nice information 👍👍👍

  • @Akash24274
    @Akash24274 3 года назад +1

    And very good quality of video

  • @hazratbilal7246
    @hazratbilal7246 3 месяца назад

    How you assume the paste rate???

  • @sanjeevkumar-kw7sj
    @sanjeevkumar-kw7sj 3 года назад +1

    Sar ismein Beria son Kitna achieve karna hai

  • @Akash-1238
    @Akash-1238 4 месяца назад

    1 core kitne area se cut karte hai

  • @naveensingh9237
    @naveensingh9237 2 года назад +1

    Clear core cutting test

  • @ajaykumarverma7387
    @ajaykumarverma7387 3 года назад

    very nice information sir ....

  • @vilaspatil3148
    @vilaspatil3148 8 месяцев назад

    What about steel factory sir

  • @harishmalladihalli4588
    @harishmalladihalli4588 2 года назад

    Sooper info dhanyavaad.

  • @deepakjain9053
    @deepakjain9053 3 года назад

    Goooood important knowledge boss👍👍

    • @guddukumarsah-h5n
      @guddukumarsah-h5n 5 месяцев назад

      Sir Core cutting Kitna meter Mai karna chaiya

  • @faultychannel7106
    @faultychannel7106 3 года назад +1

    Where are you from sir

  • @nemichandbabal.7533
    @nemichandbabal.7533 3 года назад +2

    Sir ye individual strength me fail ho rhe h as per code IS -456

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +3

      Sir ji ish condition mein jish cube ka strength kam ya jada aati hai usko cube ko discard kar dete hai aur 2 cube ka average lete Hain..

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +3

      2 cube ki average strength not less than 21.25 N/mm2 as per is code 85 % of Grade of concrete..& individual strengths 75%..

    • @nemichandbabal.7533
      @nemichandbabal.7533 3 года назад +2

      Bahut bahut dhanyawad sir

  • @jyotirmoy_43
    @jyotirmoy_43 Год назад

    Thank you sir . Want some more video ❤

  • @pranavnaxane2252
    @pranavnaxane2252 3 года назад +2

    Sir table mein 4th row mein 2 correction factor kese liye

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +1

      Correction factor 2 me 1 lena hai already table me mention hai is code -516 me hai please check karo..

  • @rohits1288
    @rohits1288 2 года назад

    Sir where are you from & In which company do you work ?

  • @faultychannel7106
    @faultychannel7106 3 года назад +1

    Location

  • @anilsingh8430
    @anilsingh8430 3 года назад +1

    Very nice video

  • @kamranullah4780
    @kamranullah4780 Год назад

    Dia will be check with vernier caliper

  • @mustakimansari5756
    @mustakimansari5756 2 года назад +1

    Very good 👍

  • @deviddas9511
    @deviddas9511 3 года назад

    Strength ko N/mm² se percentage me kese convert krte hein?

  • @vikramdalvi2898
    @vikramdalvi2898 2 года назад

    Steel hai to kaise test ho jaega

  • @shaikdasthagiri8517
    @shaikdasthagiri8517 3 года назад +1

    What about shotcrete core strength achieved in 28 days core strength?

  • @pchetan266
    @pchetan266 3 года назад +1

    Sir concrete cube 28 days me 100% strength chahiye
    Lekin core ka 80% kyo

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +2

      Kiyu ki cube ko conditions mea aur curing tank mein rakha jata hai jabki Core ko Foundation se nikala jata hai & test Kiya Jata hai ISH liye dear..

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +1

      Control conditions me rakha jata hai..

    • @salimjavid135
      @salimjavid135 3 года назад

      @@rbsinghcivilengineeringaca6777Sir, is there any codal reference for 80% strength (acceptable)

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +1

      Kyunki cube control condition mein rakha Kar check karte hain aur core Foundation se nikal Kar Lete hai aur check karte hain, ISH liye as per IS code 80% required hai..

    • @salimjavid135
      @salimjavid135 3 года назад

      @@rbsinghcivilengineeringaca6777 Got it, it’s clearly mentioned in IS 456 👍

  • @sachinnanavare6750
    @sachinnanavare6750 3 года назад +1

    Sir make it video on rebound hammer test Calculation and report

  • @KISHORKUMAR-mm7bg
    @KISHORKUMAR-mm7bg 3 года назад

    Excellent sir thank you sir

  • @fox6766
    @fox6766 3 года назад +1

    Any translation for this video in English?

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +3

      No dear only for Hindi language available at RUclips channel.. sorry

    • @fox6766
      @fox6766 3 года назад +1

      @@rbsinghcivilengineeringaca6777 No issue Mr. Singh
      I will try to understand if I could 😅👍🏻
      Thanks

  • @feelthegame5074
    @feelthegame5074 Год назад

    Thank you very much sir....

  • @anootalks4077
    @anootalks4077 3 года назад +1

    Individual cube strength also should not fall below 75% .. but in ur case for 2nd sample it is less than 75% what about it?

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +3

      The core individual sample acceptable limits + - 15% of average strength , As per is code - 456 & 516 , but core average strength not less than 85% of Grade of Concrete, individual Strength less than 85 % acceptable but average strength not less than 85%.. as per is code guidelines..

    • @anootalks4077
      @anootalks4077 3 года назад

      @@rbsinghcivilengineeringaca6777 ok..so individual cube strength should not be less than 15% ? If it's less than 15% and overall average strength is 85% also then we have to reject it?

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +2

      @@anootalks4077 Yes , If the strength of any one of the three cubes is much more or less than the average strength, then it is discarded and the strength of the two cubes is check the average strength for , And the strength of individual both cubes is + - 15% of average strength and average strength not less than 85 % of the grade of the Concrete .

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад

      @@anootalks4077 And if the parameters of the cube set do not meet the IS code limits, this Cube set is rejected.

    • @anootalks4077
      @anootalks4077 3 года назад

      @@rbsinghcivilengineeringaca6777 thanku very much for ur reply

  • @souravmukherjee1992
    @souravmukherjee1992 2 года назад

    Sir I just a request to you, please detail discuss about 516 and accepance criteria

  • @NikitaSharan-g3b
    @NikitaSharan-g3b 6 месяцев назад

    Correction factor samjh nahi aaya

  • @onlytanmay
    @onlytanmay 2 года назад +1

    Spreading somewhat little misinformation as per my book , because for L/D ratio of greater than 1.75 we don't have to take correction factor

  • @yashbogawar3557
    @yashbogawar3557 3 года назад +1

    Sir, one request to you, Please mention the IS CODE NO. also in video.

  • @snarasimha84
    @snarasimha84 3 года назад

    Sir core ka caping karna tha

  • @mscivilconstruction2338
    @mscivilconstruction2338 3 года назад

    sir agar steel a jaye core main to kya correction factor lagega

  • @expose.india1430
    @expose.india1430 2 года назад

    How to convert core average into percentage

  • @nishant.centkanes
    @nishant.centkanes 3 года назад

    What about variation of + - 15% of individual w.r.t average

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +2

      Dear cube ya Core , Variation +-15% hi hai but Haam ne 03 Set core liya tha is liye 3 set core me acceptable limit,, jaise ki aapane note Sheet mein Dekha hoga..
      Aur yadi individual ki baat karte Hain to not acceptable..

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +1

      Ok dear aur koi question???..

    • @AHoney-xl9ux
      @AHoney-xl9ux 3 года назад

      Dear, very nice info. But what is factor of concrete cube 15×15×15 cm during compressive test. Because ratio 15/15 = 1. Guide at this point of cube test.

  • @Anandcomdey78
    @Anandcomdey78 Год назад

    Thanks sir ji

  • @falkebrothersatulfalke9281
    @falkebrothersatulfalke9281 Год назад

    Thanks 😊

  • @RajeevKumar-cf4xq
    @RajeevKumar-cf4xq 9 месяцев назад

    Thanks sir

  • @sankartavar1867
    @sankartavar1867 3 года назад +1

    Good video

  • @mohammedarif2368
    @mohammedarif2368 2 года назад

    How to tak volume and bulk dentist

    • @onlytanmay
      @onlytanmay 2 года назад

      πr²h is volume

    • @onlytanmay
      @onlytanmay 2 года назад

      And ρ=Weight Measured/Volume

  • @manishsahu2252
    @manishsahu2252 7 месяцев назад

    sir as per is code compressive strength should not differ more than +,- 15% but aapke result mai toh 35% tak excceed kar rha hai kaise?

    • @guddukumarsah-h5n
      @guddukumarsah-h5n 5 месяцев назад

      Sir core cutting Kitna meter Mai karna chaiya

  • @AHoney-xl9ux
    @AHoney-xl9ux 3 года назад +1

    Please make video for compressive strength of concrete block.

  • @Blogcompany_New
    @Blogcompany_New 3 года назад

    Strength me variation bhut aa rha hai.. 5% tk allow hai

  • @jitendrashah205
    @jitendrashah205 6 месяцев назад

    Strength calculation video too fast.cant understand properly.

  • @shivamupadhyay3043
    @shivamupadhyay3043 Год назад

    4:02 CORE CAPPING?

  • @dineshahlawat5001
    @dineshahlawat5001 3 года назад +1

    For core test 516 :2017 follow up .

  • @SHAHBAZ7466
    @SHAHBAZ7466 Год назад

    Caping ni ki es ko

  • @utpalbiswas6292
    @utpalbiswas6292 3 года назад +1

    Nice

  • @saurabhjha4455
    @saurabhjha4455 3 года назад +1

    Good

  • @shivamupadhyay3043
    @shivamupadhyay3043 Год назад +1

    3:22 RATE OF LOADING140 KG/SQ CM/MIN

  • @aryanverma4192
    @aryanverma4192 2 года назад

    Tnx sir

  • @miniyoutuber666
    @miniyoutuber666 Год назад

    sir core test ka details vedio as per is code banyaye please

  • @DharmGoud
    @DharmGoud Месяц назад

    Correction factor 2 hona chahiye

  • @rakeshsahu3778
    @rakeshsahu3778 3 года назад +1

    Area calculations wrong

  • @rmengineers2351
    @rmengineers2351 2 года назад

    where capping

  • @mohammedarif2368
    @mohammedarif2368 2 года назад

    Without salfar clotting

  • @sreekanthnair50
    @sreekanthnair50 2 года назад

    Sir ..it's not proper explanation,, app explanation dethatha...beguth perfect tha,understandable, but a tik nahi
    Correction Factor x 1 ... not get also not get graph . Sir app beguth knowledge diyya pahale ... Mera expectation app pahale zyse explanation Dena, appka steel ka vlog super ... please keep it that way

  • @jawaharp8901
    @jawaharp8901 3 года назад

    Core test all test fail next what do demolish element

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 года назад +3

      1) rebound hammer test
      2) ultrasonic pulse velocity test
      3) discussion to designer
      4) jacketing and extra support provided
      4) calculation the load
      All parameters are not meeted, So demolish the building..

  • @PRAVEENKUMAR-xd6iw