PEB Building Components & Procedure OF PEB Building | RF Building, BC-2, BC-3 PEB Building

Поделиться
HTML-код
  • Опубликовано: 26 окт 2024

Комментарии • 43

  • @KattarSalmaniac
    @KattarSalmaniac Год назад +1

    Thank you so much sir. You're awesome. 🙌

  • @civilsitewitherprithvi7566
    @civilsitewitherprithvi7566 2 года назад +2

    Super practical hi samjhana sir

  • @shivashishupadhyay7473
    @shivashishupadhyay7473 Год назад

    Bahut accha content tha ....

  • @amjadkhankhel6694
    @amjadkhankhel6694 Год назад +1

    Welldone ❤

  • @kennyomega8937
    @kennyomega8937 Год назад +1

    Thank you

  • @CaniKissyou-s3g
    @CaniKissyou-s3g 4 месяца назад +1

    Thank you sir
    Structure definition ki calculation kaise kiya jata hai is par kuch bataye

  • @Sanjayrawat.5
    @Sanjayrawat.5 Год назад +1

    Very nyc

  • @MohammadAli-kv5dx
    @MohammadAli-kv5dx Год назад +2

    Super Sir

  • @firstfadl2444
    @firstfadl2444 2 года назад

    انا اشكرك يا مهندس انت راع ممتاز جدا

  • @ihsanullah1805
    @ihsanullah1805 Год назад +1

    Very informative

  • @ashiqaliwattoo3451
    @ashiqaliwattoo3451 Год назад +1

    Thanks

  • @neutralflowers6497
    @neutralflowers6497 Год назад +1

    Nice

  • @engrmuhammadijazkhan4142
    @engrmuhammadijazkhan4142 Год назад +1

    Very nice vedios.

  • @NANOWARRENBUFFETT
    @NANOWARRENBUFFETT 2 года назад +2

    Good job 👌👍

  • @rohitpatil1297
    @rohitpatil1297 Год назад +1

    Nice sir

  • @nhinteriorofficial
    @nhinteriorofficial Год назад +2

    Sir peb rafter, colum pelar bnane ka kam kha se milega

    • @AmitSahCivil
      @AmitSahCivil  Год назад

      kisi v PEB company se contact karna padega

  • @sharathmallu4060
    @sharathmallu4060 Месяц назад +1

    Sir can we use 300 ismb as rafter

    • @AmitSahCivil
      @AmitSahCivil  27 дней назад

      Why not, but depends upon load length

  • @shamstabrez1090
    @shamstabrez1090 2 года назад +1

    Thanks sir❤

  • @ganeshganesh5027
    @ganeshganesh5027 Год назад +1

    We do all types of peb structures and sheds

  • @venkateshdeeti2813
    @venkateshdeeti2813 Год назад +1

    Good explanation sir and clearly and neatly...
    But plz tell me how anchor bolt marked and column erection by packing plates , how coloumn to column erectioned with level.... For me sir plz explain clearly sir..

  • @pearlvalleykashmir2048
    @pearlvalleykashmir2048 2 года назад +1

    Nice keep it up

  • @user9951
    @user9951 Год назад +1

    The width of building is around 60m and height is around 9m considering the area for longitudinal wind the bracing can't withstand and you have to drain the force in interior it cannot be carried to the eave. And struct members between bracing is missing.
    For some reasons you avoid bracing at end bay and moved it to next bay if you want to move like this make sure you transfer the longitudinal wind to next bay by providing structs because purlin won't carry this much load.
    Please ensure this and revise it properly 🙏 there is lots of lives at risk. If this structure face wind above 100kmph this will collapse its sad to see engineers not giving attention to this details 😔

  • @pearlvalleykashmir2048
    @pearlvalleykashmir2048 2 года назад +1

    Please make more video regarding wearhouse

  • @santanumitra1354
    @santanumitra1354 2 года назад +1

    Please rafters ka weight kase nikalta hain ak video bana do

    • @AmitSahCivil
      @AmitSahCivil  2 года назад

      Uske liye shop drawing ki jarurat padegi but I will make videos on this

  • @sunilkumar426
    @sunilkumar426 4 месяца назад +1

    90 feet by 60 feet plot per shad banvana h ji kya cost aayegi

    • @AmitSahCivil
      @AmitSahCivil  4 месяца назад

      Aishe cost batana muskil hai, iske liye or requirement chahiye hogi, height kya chahiye, purpose kya hai, building type, sheet height, brick work height, shutter, openings, please DM with these requirements or give me yours no.

    • @sunilkumar426
      @sunilkumar426 4 месяца назад

      Dear Sir, Height 20 feet from road front me 02 sutter 18x18 feet, 01 cutter Right side 12x18 feet, plot size Length 90 feet width 60 feet total 600 Gaj plot in Haryana Panipat Area.

  • @NANOWARRENBUFFETT
    @NANOWARRENBUFFETT 2 года назад +3

    Many peb engineer don't know the importance of cross bracing. Very very important. On the roof and at the column

  • @pearlvalleykashmir2048
    @pearlvalleykashmir2048 2 года назад +1

    How to read wearhouse steel structure drawings

  • @fabricationboy1347
    @fabricationboy1347 Год назад +1

    Hi

  • @venkateshdeeti2813
    @venkateshdeeti2813 Год назад +1

    Please reply sir

  • @ashokkamble3535
    @ashokkamble3535 2 года назад +1

    Sir bolting kavideobanao

    • @AmitSahCivil
      @AmitSahCivil  2 года назад

      Already uploaded hai please check playlist

  • @hariomkumhar
    @hariomkumhar Год назад

    Setting ke liye contact

  • @ganeshganesh5027
    @ganeshganesh5027 Год назад

    Any one need a shed please contact for more details

  • @vikashsolanki4161
    @vikashsolanki4161 4 месяца назад +1

    Any one need a warehouse industrial shed please contact me