Good explanation sir and clearly and neatly... But plz tell me how anchor bolt marked and column erection by packing plates , how coloumn to column erectioned with level.... For me sir plz explain clearly sir..
The width of building is around 60m and height is around 9m considering the area for longitudinal wind the bracing can't withstand and you have to drain the force in interior it cannot be carried to the eave. And struct members between bracing is missing. For some reasons you avoid bracing at end bay and moved it to next bay if you want to move like this make sure you transfer the longitudinal wind to next bay by providing structs because purlin won't carry this much load. Please ensure this and revise it properly 🙏 there is lots of lives at risk. If this structure face wind above 100kmph this will collapse its sad to see engineers not giving attention to this details 😔
Aishe cost batana muskil hai, iske liye or requirement chahiye hogi, height kya chahiye, purpose kya hai, building type, sheet height, brick work height, shutter, openings, please DM with these requirements or give me yours no.
Dear Sir, Height 20 feet from road front me 02 sutter 18x18 feet, 01 cutter Right side 12x18 feet, plot size Length 90 feet width 60 feet total 600 Gaj plot in Haryana Panipat Area.
Thank you so much sir. You're awesome. 🙌
Super practical hi samjhana sir
Bahut accha content tha ....
Welldone ❤
Thank you
Thank you sir
Structure definition ki calculation kaise kiya jata hai is par kuch bataye
Very nyc
Super Sir
انا اشكرك يا مهندس انت راع ممتاز جدا
Very informative
Thanks
Nice
Very nice vedios.
Good job 👌👍
Nice sir
Sir peb rafter, colum pelar bnane ka kam kha se milega
kisi v PEB company se contact karna padega
Sir can we use 300 ismb as rafter
Why not, but depends upon load length
Thanks sir❤
We do all types of peb structures and sheds
Good explanation sir and clearly and neatly...
But plz tell me how anchor bolt marked and column erection by packing plates , how coloumn to column erectioned with level.... For me sir plz explain clearly sir..
Plz reply sir
Please Watch my anchor bolt video, from PEB Building Playlist
Nice keep it up
The width of building is around 60m and height is around 9m considering the area for longitudinal wind the bracing can't withstand and you have to drain the force in interior it cannot be carried to the eave. And struct members between bracing is missing.
For some reasons you avoid bracing at end bay and moved it to next bay if you want to move like this make sure you transfer the longitudinal wind to next bay by providing structs because purlin won't carry this much load.
Please ensure this and revise it properly 🙏 there is lots of lives at risk. If this structure face wind above 100kmph this will collapse its sad to see engineers not giving attention to this details 😔
Please make more video regarding wearhouse
Sure
Please rafters ka weight kase nikalta hain ak video bana do
Uske liye shop drawing ki jarurat padegi but I will make videos on this
90 feet by 60 feet plot per shad banvana h ji kya cost aayegi
Aishe cost batana muskil hai, iske liye or requirement chahiye hogi, height kya chahiye, purpose kya hai, building type, sheet height, brick work height, shutter, openings, please DM with these requirements or give me yours no.
Dear Sir, Height 20 feet from road front me 02 sutter 18x18 feet, 01 cutter Right side 12x18 feet, plot size Length 90 feet width 60 feet total 600 Gaj plot in Haryana Panipat Area.
Many peb engineer don't know the importance of cross bracing. Very very important. On the roof and at the column
Right sir
How to read wearhouse steel structure drawings
Hi
Please reply sir
Sir bolting kavideobanao
Already uploaded hai please check playlist