Duay hai jii aap logo ki 😊...Mai ekdam badhiya ...aap kaise hai ..bas Thoda work load jyada ho gaya hai isliye vidio nahi AA upload ho paati hai dost 👍
machine off condition me Dono line se daal sakte hai lekin try karo ko discharge line se gas daalo liquid form me .... suction se daalna hai to vapor me daalo jisse ki ...jab machine on ho to compressor pe suddenly load na pade 👍
Dost ... Hamne 3 vidio upload ki hui hai 1. Top 10 question and answer 2. Top 9 question and answer 3. Top 7 ahu question and answer In sabka link description me hai aap dekh sakte hai..Baki agar koi doubt ya question hai to aap phir pooch Lena dost 👍
@@c4chiller9984 mere kehne ka matalab hai.. bahut der tak... Karne se dikkat to nhi aayega... Means machin ya pipe me dikkat aayegi ya efficiency kam hogi...
dost ..ek video maine upload kiya hau hai Jo gas abhi chAl rahi hai un sabki vidio hai ..... description me link hai dost ...AAP dekh Sakte hai sukriYa 👍
dost ... value hai 1 year diploma ki but apko uske sath sath minimum 3 years ka HVAC me experience hona jaruri hai yani ki apki knowledge achi hogi to apko bagair certificate ke bhi select kar liya jata hai ... aor agar knowledge nahi hai to Aap chahe b.tech hi q na ho selection technician level pe nhi hoga ...👉 mai yahi kahoonga dost .. knowledge jaha se bhi mile aap lete raho ..baad me interview do nikal jayega ..👍 baaki Jo bhi doubt ya question ho to aap kabhi bhi pooch sakte Ho 👍
Dekhiye dost...koi bhi HVAC ka system ho pahle aap Thoda nitrogen daalke check kariye 100 psi agar leak nahi mil raha hai 100 psi pe to aap 150 psi add karo agar 150 psi pe maximum leak mil jaate hai ...Lekin agar phir bhi leak na mile to aap 200 psi add Karke saare joint pe check karo jaha jaha doubt HOTA hai...,👉phir bhi nhi Mila to aap 12 hours ke liye hold kardo nitrogen system me agle din aao aor check karo agar pressure ok hai to vacuum me Laga do system nitrogen nikal ke ...Kuch abhi bhi question ho to pooch Lena dost 👍
walaikum assalam...dost 😊 ji mai bilkul theek....aap kaiSe hai ? dost time bahoot kam milta hai isliye vidio bana hi nahi pa Raha hu 👉.but agar apka koi question ya doubt hai to aap pooch sakte hai mai try karoonga apke answer Dene ka .. sukriya 👍
Dost.. Pahle aap gauge band karenge aor phir gauge ko dekho ki uski needle (सुई ) - 30 psi pe ruki hai ya badh Rahi hai ...agar needle ruki hai to iska Matlab vacuum ho gaya hai ...aor phir aap vacuum pump band kar do 👍
Sir mere selection hua hai HVAC Technician me scientific company Soudi ke main confuse ho company kaisa hai or medical v ho gaya hai kya ap kuch help kar sakte hai❤
dost .. GPM ( Gallon per Minute) hota hai kahi bhi agar water ka circulation hota hai to ham use GPM me masurment karte hai .. 1 GPM water = 3.785 leter water ke barabar hota hai ...
jaise ki agar hamara chiller 100 tr ka hai to uska water flow rate 240 GPM hoga approx...1 TR = 2.4 GPM hota hai 👍 .abhi bhi agar kuch doubt ho to aap pooch sakte hai jii 👍
Waw very good 👍 informative video sir I am in kuwait I get more knowledge with your videos
thank you atayam 👍👍
@@c4chiller9984
Wlcm sir
Wo every videos help full 🎉 allso videos very nice
Ji sukriya apka 👍
Bhut sunder brother
Great sir your videos very informative kindly make video about subcool and super heat
Ok jii will try in next vidio 👍
Assalamo alaikum Bhai bahut din se wait kar rhe the 1st comment and 1st Vive
Ji walaikum assalam bhai 😊
Bas Thoda work load jyada ho gaya hai isliye vidio upload nahi ho pati hai ...but sukriya apke Pyar aor supporting ka 🙏🙏
Superb guru ji 😊
Thank you jii your loving and supporting 🙏🙏🙏♥️
Thank you for information 🙏
Nice video sir ji
Thank you jii 👍
Thank you for information
👍
Good
Sir long time ke bad video upload huwa hai All is well sir
Duay hai jii aap logo ki 😊...Mai ekdam badhiya ...aap kaise hai
..bas Thoda work load jyada ho gaya hai isliye vidio nahi AA upload ho paati hai dost 👍
Nice video
Ji sukriya apka 👍
Video chota hey but mokammel.jazakallah,,
thank you 👍
Nice
Sir ji pump down kaise karte h ki puri gas candensor me stor ho jaye sefty bypaas karna padta h kya chiller me ya bade unit me
🙏🏽
Bhai 700 Micron bhi aana hota hai kya water cooled chiller me
Hello sir please make a video about pumpdown of cold room unit ( pumpdown from liquid receiver)
ok ..dost
dekho mai jaldi hi apke topic pe practical me vidio upload kar doonga 👍
Sir pls FCU Ahu ka wiring pe eak video bna dijiye pls
dost ...abhi hamare yaha pe FCU hai nahi ...agar kidhar bhi side pe milta hai to mai practical me vidio upload kar doonga 👍
Hello Ji bahut Dino ke bad aap video upload kiye
Aaj kal kuch jayada hi busy hai
Ajay Rathod
Jii..bhai ..
Thoda work load jyada ho gaya hai isliye time Kam mil pata hai jii
But ...very thank you for loving and supporting 🙏💗
Sir app kis company Mai job kr rahe hai hum ko bhi waha ka interview Deni hai
Machine band hone may donu line se gas dhal sakta ho keya vai??
machine off condition me Dono line se daal sakte hai lekin try karo ko discharge line se gas daalo liquid form me .... suction se daalna hai to vapor me daalo jisse ki ...jab machine on ho to compressor pe suddenly load na pade 👍
Sir app chiller technician entervue pe vedeo banai plz kya kya question puchta hai
Dost ...
Hamne 3 vidio upload ki hui hai
1. Top 10 question and answer
2. Top 9 question and answer
3. Top 7 ahu question and answer
In sabka link description me hai aap dekh sakte hai..Baki agar koi doubt ya question hai to aap phir pooch Lena dost 👍
Or kijeye
Time milega to Mai jarur upload karoonga dost 👍
Sir water cooled chiller ka gpm kaise nekalata ha
GPM= TR×2.4 I will find with formula.
Limit se Jyada der tak Vaccum krne se kya hoga
system aor bhi acha vaccum ho jayega
@@c4chiller9984 mere kehne ka matalab hai.. bahut der tak... Karne se dikkat to nhi aayega... Means machin ya pipe me dikkat aayegi ya efficiency kam hogi...
Dost ..
Agar aap micron me vaccum kar rahe hai to 600 micron enough hai aor agar
Manifold gauge se vaccum kar rahe ho to - 30 psi hona chahiye...
R410 or R407or R32 r22 sabka suction or discharge or running pressure bta do Bhai please
dost ..ek video maine upload kiya hau hai Jo gas abhi chAl rahi hai un sabki vidio hai ..... description me link hai dost ...AAP dekh Sakte hai sukriYa 👍
@@c4chiller9984 Bhai mujhe ye sab Ka chahiye tha
Nitrogen koi bhi ac parts shop me mil jayega????
ji ha dost ...ac ki shop pe Milne ka chance rahta hai 👍
Sir
Mai India me ek technical institute se 1 year AC/HVAC diploma kiya hu
Gulf me 1 year diploma certificate ki value hai kya?
Please reply
dost ... value hai 1 year diploma ki
but apko uske sath sath minimum 3 years ka HVAC me experience hona jaruri hai yani ki apki knowledge achi hogi to apko bagair certificate ke bhi select kar liya jata hai ...
aor agar knowledge nahi hai to Aap chahe b.tech hi q na ho selection technician level pe nhi hoga ...👉
mai yahi kahoonga dost .. knowledge jaha se bhi mile aap lete raho ..baad me interview do nikal jayega ..👍
baaki Jo bhi doubt ya question ho to aap kabhi bhi pooch sakte Ho 👍
@@c4chiller9984 Thank you so much Sir
God Bless You
Bhai BTU unit ka pura video karona kitna flow hona
kis cheej ka flow cahiye apko ?
Sir 250 tr water cooled chiller ma nitrogen ketna psi charge karna chaiye
Kon sa gas hainusme
Dekhiye dost...koi bhi HVAC ka system ho pahle aap Thoda nitrogen daalke check kariye 100 psi agar leak nahi mil raha hai 100 psi pe to aap 150 psi add karo agar 150 psi pe maximum leak mil jaate hai ...Lekin agar phir bhi leak na mile to aap 200 psi add Karke saare joint pe check karo jaha jaha doubt HOTA hai...,👉phir bhi nhi Mila to aap 12 hours ke liye hold kardo nitrogen system me agle din aao aor check karo agar pressure ok hai to vacuum me Laga do system nitrogen nikal ke ...Kuch abhi bhi question ho to pooch Lena dost 👍
Sir apna Andaj sa Bata digya ki nitrogen kitna delta ha chiller ma
Sir 250 psi Dal da to koe problem to nhi
Apke chiller me gas konsi use ho Rahi hai ?
Bhai saheb 😊 Gurgaon me kidher h☺️
gurgaon...ka hai dost. sector 62 🤗
Bhai compressor unloaded solenoid valve Kharb ho gaye .....kay Kya reason se karab hota hai Bhai .....batao Bhai plzzz Bhai....
scrue compressor hai apka ?
Nhi Bhai semi hermetic compressor hai Jo zamil package DX unit hai
Thanks bhai apki video dekhe mene cilar operator Job milla
❤❤❤ apnki number mil jay
Me Bangladeshi ho
dost ...ye mera instagram id hai aap yahA pe bat kar sakte hai id 👉 kgufran195
Asw bhai. Sir ji sab kharyat hai na. RUclips e video uploading nhi hu thi 😢
walaikum assalam...dost 😊
ji mai bilkul theek....aap kaiSe hai ?
dost time bahoot kam milta hai isliye vidio bana hi nahi pa Raha hu
👉.but agar apka koi question ya doubt hai to aap pooch sakte hai mai try karoonga apke answer Dene ka .. sukriya 👍
Vacuum band krne se pehle ka process bhi bta dijye kaise check kre ki vacuum hold hua hai or pehle gadge band krna hai uske baad machine off krna hai
Dost..
Pahle aap gauge band karenge aor phir gauge ko dekho ki uski needle (सुई ) - 30 psi pe ruki hai ya badh Rahi hai ...agar needle ruki hai to iska Matlab vacuum ho gaya hai ...aor phir aap vacuum pump band kar do 👍
@@c4chiller9984 thanks sir jiii new student ke liye yeh bhi jaana jaruri hai
Ji ha ..jaruri hai
Dekho agar time Mila to Mai practical me ye samjha doonga 👍
Vacuum selection also one point plzzz explain
I have more knowledge with your vedio.
👍👍
Lekin sir inhg likha hota h psi nahi vacuum me
Please reply sir ji 🙏🏽🙏🏽🙏🏽🙏🏽
Sir mere selection hua hai HVAC Technician me scientific company Soudi ke main confuse ho company kaisa hai or medical v ho gaya hai kya ap kuch help kar sakte hai❤
ji bataiye kaise help chaiye apko ?
@@c4chiller9984 janana hai ye company kaisi hai? Scientific medical equipment
Sir GPM kya hota hai ?🤔
dost ..
GPM ( Gallon per Minute) hota hai
kahi bhi agar water ka circulation hota hai to ham use GPM me masurment karte hai .. 1 GPM water = 3.785 leter water ke barabar hota hai ...
jaise ki agar hamara chiller 100 tr ka hai to uska water flow rate 240 GPM hoga approx...1 TR = 2.4 GPM hota hai 👍 .abhi bhi agar kuch doubt ho to aap pooch sakte hai jii 👍
Thank you sir 😊 ☺️
Thrust bearing alarm ka sulesan
york chiller hai
Sir I am mohammad ali - I want apprenticeship
Ok dear Ali
Kya knowledge chaiyee apko HVAC se related?
Sir i respect you, sir i need your whatsapp nub becouse we have doubt of hvac system
dost ...its my Instagram ID 👉 kgufran195
koi bhi questions ya doubt hai to aap yaha pe pooch sakte hai dost 👍