Ejector, Hogger system and Vacuum in Condenser

Поделиться
HTML-код
  • Опубликовано: 24 ноя 2024

Комментарии • 10

  • @basili5238
    @basili5238 3 месяца назад +1

    Great Summary!! Thank you

  • @devivara1162
    @devivara1162 10 месяцев назад +1

    Sir why water sealing is provided in oil purifier???any 2 advantages of separtion with water and oil??

  • @devivara1162
    @devivara1162 9 месяцев назад +1

    Sir what is emergency stop valve??? What is ESv atmospheric vent???

    • @theRedArt
      @theRedArt 9 месяцев назад +1

      In any critical situation temperature, pressure high or low , any other critical interlock acts in Turbine The Emergency Stop Value ESV will close Suddenly to save the turbine

    • @theRedArt
      @theRedArt 9 месяцев назад +1

      Esv placed before the Governing value

  • @devivara1162
    @devivara1162 9 месяцев назад +1

    Sir what is warm up vent in Steam turbine??

    • @theRedArt
      @theRedArt 9 месяцев назад +2

      At the time of turbine rolling there is no steam flow through the turbine, whenever steam passes through the stream then only temperature will raise, The warm up vent was placed nearly to the Esv inlet line before

  • @inner_voice73
    @inner_voice73 10 месяцев назад +1

    Why a hogger is needed initially, when ejector can do the same job!

    • @powerplantguru007
      @powerplantguru007  10 месяцев назад

      Hello Durga
      Hogger is also one kind of ejector, but it's size and steam consumption is higher and it is required when there is no vacuum in condenser and you need more power to establish the initial vacuum. Once you have established the initial vacuum then there is only requirement of only to maintain which may be small as.compared to initial requirements.

    • @wookie281291
      @wookie281291 2 месяца назад +1

      When starting up your sjae would you open your Steam or Air first and why?