  • @ayushjptechnical5740
    @ayushjptechnical5740 4 месяца назад +1

    Nice good information

  • @gufransaifi3175
    @gufransaifi3175 Год назад

    Thank you sir

  • @UmaprasannaBarik
    @UmaprasannaBarik Год назад

    Sir if i changed a motor field voltage 110 to 220 v what parameter or wiring to be chaned in drive dcs 800

  • @UmaprasannaBarik
    @UmaprasannaBarik Год назад

    If i change a dc motor having field voltage 110 to 220 which parameter/wiring
    to be changed

  • @gufransaifi3175
    @gufransaifi3175 Год назад +1

    Next video

  • @hearttouchingwords6221
    @hearttouchingwords6221 Год назад

    300 A dc load box ready karna hai to kon sa drive sahi hoga input volt 110 vdc hai

  • @Hasib.khana.eeeeee
    @Hasib.khana.eeeeee 6 месяцев назад

    Dcs800 drive me x96 me kon sa wire connect hota hai sir ji

    • @knowledgedevelopmentchanne8720
      @knowledgedevelopmentchanne8720  6 месяцев назад

      Yah as a realy kaam karta hai ,yah output DO8 hai. As a dc contactor on /off ke liye use Kiya jata hai.
      Thanks for query,
      If any more query then ask me.

    • @Hasib.khana.eeeeee
      @Hasib.khana.eeeeee 6 месяцев назад

      Sir ji 24v dc out put deta hai

  • @kuldeepdhiman7570
    @kuldeepdhiman7570 Год назад

    Sir,
    Please guide me. ABB DCS800 me armature over volt ka fault aa raha h. Kya reason ho sakta h. Please bataye

    • @knowledgedevelopmentchanne8720
      @knowledgedevelopmentchanne8720  Год назад

      What is fault, fault is F503?

    • @knowledgedevelopmentchanne8720
      @knowledgedevelopmentchanne8720  Год назад

      Drive on karte hi trip ho raha hai ya thori der baad trip ho raha hai?

    • @knowledgedevelopmentchanne8720
      @knowledgedevelopmentchanne8720  Год назад

      Agar turnt trip ho raha ho to cable check karo or agar thori der baad trip ho raha ho to feedback ka problem ho sakta hai.

    • @kuldeepdhiman7570
      @kuldeepdhiman7570 Год назад

      @@knowledgedevelopmentchanne8720 fault is F503. And ye 2day ya 10day ya 25day me hota h kabhi kabhi...

    • @knowledgedevelopmentchanne8720
      @knowledgedevelopmentchanne8720  Год назад

      Please check your encoder and speed feedback. When it trips that time please check speed of equipments. What is speed, may at maximum speed, it's trip.
      You can check also by bypass encoder.

  • @gufransaifi3175
    @gufransaifi3175 Год назад

    Sir all perameters details

  • @umeshkumar-e8x2g
    @umeshkumar-e8x2g 26 дней назад

    Hi sir how to SOLVE Problem of ABB DCS550 FAULT 541

    • @knowledgedevelopmentchanne8720
      @knowledgedevelopmentchanne8720  24 дня назад

      This is related to field current issue , please to be observe field current during load and high speed .That means field weakening ,it is match with motor name plate or not.
      Please see the parameters of field 44 .
      If problem not resolve than you can field tunning also .
      I think problem will be resolve.

    • @umeshkumar-sx8tm
      @umeshkumar-sx8tm 23 дня назад

      thank your replay sir ,

    • @umeshkumar-sx8tm
      @umeshkumar-sx8tm 23 дня назад

      sir can you solve ABB DCS550 drive when i start without load dc motor (90kw, armature 225 A, FIELD 6.78A ) , remote mode and i observe field current taking 10A, and check voltage 375vdc, ,armature load 2.3 ampere motor is not run after few second f541 fault show in bop panel and if i change parameter 9012 not use and 2118 on run local mode motor runt but if increase speed 50 rpm above motor trip

    • @knowledgedevelopmentchanne8720
      @knowledgedevelopmentchanne8720  22 дня назад

      Keep current limit 50% then 100%
      Keep stand by field 25% ,50%,75% and 100%
      Keep drive in local mode and operate operating panel locally .Start speed from slow like 10,20,40,50 and increase check to all current is ok or not.
      If not resolve then please auto tune to motor ,note down before and after 24,43 ,44.
      Important parameters is 24,43,44,99

  • @ashishgoyal9565
    @ashishgoyal9565 5 месяцев назад

    Sir aapka number

  • @UmaprasannaBarik
    @UmaprasannaBarik Год назад

    If i change a dc motor having field voltage 110 to 220 which parameter/wiring
    to be changed