I don't have much idea about the industry...but you can join our telegram support group etp knowledge junction where many professionals are available to help you.
First we have to master in wastewater management. Have to know about all the process deeply. This is so simple 😊 If you are a professional, we can work together. sanjeetrawat684@gmail.com . . Join telegram group ETP Knowledge Junction and personally msg me on instagram iamsanjeetrawat
Tube settler retention time refers to the duration that water remains in contact with the tube settlers within a settling tank. It is an important parameter in the design and operation of sedimentation systems, as it directly affects the efficiency of solid particle removal. The retention time is typically calculated based on the flow rate and the effective settling area of the tube settlers. To calculate the tube settler retention time, you need to follow these steps: 1. Determine the flow rate: The first step is to determine the flow rate of water entering the settling tank. This can be measured directly using flow meters or estimated based on the design parameters of the system. 2. Calculate the effective settling area: The effective settling area is the total surface area of the tube settlers that is available for sedimentation. It can be calculated by multiplying the total number of tube settlers by their individual surface area. 3. Calculate the volume of water in contact with tube settlers: Multiply the flow rate by the effective settling area to obtain the volume of water in contact with tube settlers per unit time. 4. Calculate the retention time: Divide the volume of water in contact with tube settlers by the total volume of water in the settling tank to obtain the retention time. The formula for calculating tube settler retention time can be expressed as: Retention Time = (Effective Settling Area × Flow Rate) / Total Volume It is important to note that this calculation assumes ideal conditions and does not take into account factors such as short-circuiting, hydraulic inefficiencies, or variations in influent characteristics. Therefore, it provides an estimate rather than an exact value. In practice, it is recommended to conduct pilot-scale tests or use computational fluid dynamics (CFD) simulations to validate and refine the calculated retention time for specific applications.
Sir ek video bnaye jisme harek tank ke bare mai detail mai btaye jaise har tank ka hrt kiya hai kon sa bacteria hai kiya parameters hone chiye har ek tank ka kiya kaam hai
Hi Ajay, Sabse pahle to aapko aapke aeration tank ka hydraulic retention time nikalna Hoga. hydraulic retention time ke bare mein janne ke liye aap channel per uploaded video hydraulic retention time dekh sakte ho. Uske bad aapko aapke plant capacity ke hisab se jo bhi aap equalization tank se aeration tank mein feeding karte ho uss feeding ko aapko 24 ghante ke hisab se barabar Bhag Mein bantana Hoga. let suppose Agar aap 24 KL feed karte hain to aapko 24 ghante se use divide karna hoga. yani ki aapko per Ghanta 1KL feed karna hoga.
Chrome effluent ko effluent treatment plant mein treat karne ke liye aam taur par **sodium bisulfite (NaHSO₃)** ka upyog kiya jata hai. Yeh chemical hexavalent chromium (Cr⁶⁺), jo atyadhik vishaila hota hai, ko trivalent chromium (Cr³⁺), jo kam vishaila hota hai, mein badal deta hai. Yeh reaction aam taur par amliya vatavaran mein hoti hai, aur iske baad trivalent chromium ko chromium hydroxide (Cr(OH)₃) ke roop mein precipitate kiya ja sakta hai, jise solution ke pH ko chuna ya kisi anya kshar ke saath badhakar kiya jata hai.
Sir ,hamara solvent plant hai ,tho use hum effluent ko neutral kar ke wo UASB Ko feed karte hai ,lekin uske baad hamara UASB distrub ho jaata hai,tho hame alag si solvent treat karne ka solution bataye
Solvent ko UASB me feed krne se phle... pretreatment krna jaruri hai... Oil grese ko remove krna jaruri h...COD ko balance krna jaruri h...Aap mujhe feeding effluent ke parameters bataen
Sir biological etp me paani clear karne ke aur ph maintan karne liye lime aur alum ke alava kya sulfamic powder use kar sakte hai kya aur dusra koi chemical honga to please batao
Bod load badh jata hai ya DO km hota h ya culture km ho jata h jb... Aur bhi kai Karan ho sakte hn.. Join telegram group ETP Knowledge Junction and personally msg me on instagram iamsanjeetrawat.
We just getting too much foaming in Ctech basin nowadays. Just in a 10mins off short time. Please can we have a conversation on this. I'm tired of taking care of this situation. And actually right now due to covid lots of companies are stopped. So we're getting just 14-15 MLD water.
Hi Abhay, Thanks for writing us. Aapko main batana Chahunga Pani Mein jhag tabhi bnta Hai Jab usmein pollution ki Matra hoti hai inlet Mein forming Hona Aam baat hai lekin Agar outlet treated water mein bhi forming ho rahi hai iska matlab hai vah Puri Tarah Se treat Nahin hua hai usmein abhi bhi suspended solids Honge aur vaha Pani turbid hoga kripya yah jaanch len ki aapka treated water Puri Tarah Se crystal clear Ho yani ki uske andar jo bhi BOD hai vah remove hui ho Thanks dear stay connected❤️
Sar ji namaste main ETP plant chalata hun sar ji 10.KL ka plant hai sar ji mere ko yah bataiye poli kitni dalni chahie chuna Kitna dalna chahie fitkari kitni dalni chahie 10 kilodi ka plant hai Pani Kala aata hai
Dost lab me sample leke jao... naap tol ke sample lo.. naap tol ke solution banao alam, poly aur lime ka.. uske baad settling shuru karo.. dekho ki kitne leter ya ml effluent ko settling karane me kitna chemical lga. Uske hisaab se plant me settling kro.
Fresher ke liye maine video bnai h... Aur ap meri baki ki videos bhi dekh sakte ho... Sari in formative hn... Aur cumminity tab pr questions dalta hu. .. You can join telegram group ETP Knowledge Junction and personally msg me on instagram iamsanjeetrawat.
11 месяцев назад
Sir., In my ETP there is jelly type biomass formed & also white foaming. What is reason for this jelly formation
The formation of jelly-like biomass and white foaming in an Effluent Treatment Plant (ETP) can be indicative of various issues in the treatment process. Here are some possible reasons and solutions: **Possible Reasons:** 1. **Filamentous Bacteria Overgrowth:** - **Reason:** Overgrowth of filamentous bacteria can lead to the formation of a jelly-like biomass. - **Solution:** Adjust the microbial population by optimizing aeration, nutrient levels, and pH. Consider using specific microbial products to control filamentous bacteria. 2. **Nutrient Imbalance:** - **Reason:** Imbalance in nutrient levels, particularly nitrogen and phosphorus, can contribute to biomass formation and foaming. - **Solution:** Conduct a nutrient analysis and adjust the nutrient dosing to achieve a balanced nutrient ratio. 3. **Aeration Issues:** - **Reason:** Inadequate or uneven aeration can lead to localized anaerobic conditions, causing foaming. - **Solution:** Optimize aeration systems, check diffuser efficiency, and ensure proper mixing to maintain aerobic conditions. 4. **pH Fluctuations:** - **Reason:** pH variations can impact microbial activity and favor the growth of certain organisms. - **Solution:** Monitor and control pH levels within the optimal range for biological treatment. 5. **Organic Overloading:** - **Reason:** High organic load can overwhelm the treatment system, leading to biomass overgrowth and foaming. - **Solution:** Ensure that the influent organic load is within the designed capacity of the ETP. Consider adjusting the flow or implementing pretreatment if necessary. 6. **Presence of Surfactants:** - **Reason:** Surfactants in the influent can contribute to foam formation. - **Solution:** Identify and minimize the source of surfactants. Consider using antifoaming agents if necessary. **Actions to Take:** 1. **Microbial Analysis:** - Conduct a microbial analysis to identify the composition of the biomass and determine if specific types of bacteria are causing issues. 2. **System Optimization:** - Optimize operational parameters, including aeration, pH, and nutrient levels, based on the characteristics of the wastewater. 3. **Foam Control Agents:** - Consider using foam control agents or antifoaming agents to address excessive foaming temporarily while underlying issues are resolved. 4. **Regular Monitoring:** - Implement a regular monitoring program to assess the performance of the ETP and make adjustments as needed.
Sir According to my experience I have seen more importance are given for production and very less importance given for waste water or etp and this section r directly related to public n environment
Namaste sir mujhe ya Jaana Hai ki stp plant ke sbr me svi kitna se kitna tk hona chahiye And mujhe vi Jaana Hai ki svi ko kese increase kiya jaye Mera sbr me 150 Sv 30 hai but mlss 10560 ho jata hai kyou ki sewage ke sath send vi aa raga hai but fir vi koei to rasta hoga ki svi increase kese karu plz help me
Bohot hi badhiya aur helpfull video banaya hai sir ji aap ne thank you so much 💞 u n God 🙏 bless you
Thanks dost... Stay connected with channel... Aap Facebook page pr bhi review de sakte ho ..❤️
Sir etp me chrome ke liye hame konsa chemical use karte h
Please provided the interview questions for fermentation and distillation of alcohol industry
I don't have much idea about the industry...but you can join our telegram support group etp knowledge junction where many professionals are available to help you.
Sir agar testing k parameter k bar me bta do ki konsi testing se ky hota h kya fayada h kya nuksaam
Sir ek aap video banaye jisme
Bod .cod .tds mlss jar testing ka
Sir Etp plant ki capacity kese nikalte h
Provide process of ETP aerobic system with proper define function of ph cod bod mlss mlvss SLI fm ratio DO level and jar rest
ruclips.net/video/0MPfrQV1df0/видео.html
Sir etp plant design kaise krte h. Par bhi video banoaao
Hi dost.. you can join telegram group ETP Knowledge Junction
धन्यवाद सर
खूप छान माहीती आहे 👍
तुमि पन विचारू शकतो।
@@ETPKnowledgeJunction सर तुम्ही अजून विडिओ बनवत राहा , खूप शिकायला मिळतंय तुमच्या कडून तेही सोप्या भाषेत
Thanks dear
Etp treatment water colour is white kya dosing kre
Sir please one video mak a BOD analysis with titertion please sir
High cod ko kaise down kare
Please bataye sir
How to solve secondary clarifier sludge bulking
Plz explain fm ratio calculation with example..
ruclips.net/video/uuYHFK_Gvo0/видео.html
Example in video description.
U r have a good teacher ability
Thanks dear
Who to control Aeration tank outlet sample turbidity?
Hi dipak...
Dedicated video on turbudity is there in Playlist. And stay connected..
Sir can you please share the formula for blower selection and how to decide number of diffusers to be installed in aeration tank.
Hi dear.. you can watch meenu Jain Lalitpur video on RUclips.. about calculation of aeration system. Or join telegram group ETP Knowledge Junction
Sir distillery me Mee plant ka condensate ke pane ko kese clear kerte hai
How design stp and etp plant...?
First we have to master in wastewater management. Have to know about all the process deeply. This is so simple 😊
If you are a professional, we can work together. sanjeetrawat684@gmail.com
.
.
Join telegram group ETP Knowledge Junction and personally msg me on instagram iamsanjeetrawat
Stp plant me outlet bale pani me chlorine kyo mixs krte h.or kis baictiriya removed krta h .
पानी में badbu नही आये
Clorine se bacteria dead hote hn...
ruclips.net/video/NhfXPv0_MxM/видео.html
Wastewater odour- cause and solutions
Bhaiya Tube Settler Retention timings kaise calculate karte hain?
Tube settler retention time refers to the duration that water remains in contact with the tube settlers within a settling tank. It is an important parameter in the design and operation of sedimentation systems, as it directly affects the efficiency of solid particle removal. The retention time is typically calculated based on the flow rate and the effective settling area of the tube settlers.
To calculate the tube settler retention time, you need to follow these steps:
1. Determine the flow rate: The first step is to determine the flow rate of water entering the settling tank. This can be measured directly using flow meters or estimated based on the design parameters of the system.
2. Calculate the effective settling area: The effective settling area is the total surface area of the tube settlers that is available for sedimentation. It can be calculated by multiplying the total number of tube settlers by their individual surface area.
3. Calculate the volume of water in contact with tube settlers: Multiply the flow rate by the effective settling area to obtain the volume of water in contact with tube settlers per unit time.
4. Calculate the retention time: Divide the volume of water in contact with tube settlers by the total volume of water in the settling tank to obtain the retention time.
The formula for calculating tube settler retention time can be expressed as:
Retention Time = (Effective Settling Area × Flow Rate) / Total Volume
It is important to note that this calculation assumes ideal conditions and does not take into account factors such as short-circuiting, hydraulic inefficiencies, or variations in influent characteristics. Therefore, it provides an estimate rather than an exact value.
In practice, it is recommended to conduct pilot-scale tests or use computational fluid dynamics (CFD) simulations to validate and refine the calculated retention time for specific applications.
@@ETPKnowledgeJunction Thank you so much... 🙏
Sir fm ratio kaise calculate karte hai??
Sir ek video bnaye jisme harek tank ke bare mai detail mai btaye jaise har tank ka hrt kiya hai kon sa bacteria hai kiya parameters hone chiye har ek tank ka kiya kaam hai
Sure stay connected
Sir,Sludge is not settling in aeration and secondary clarifier please suggest
ruclips.net/video/uDmOwjY1sMo/видео.html
Sir etp new ruls par video banao
Stay connected... tayari chal rahi h
Dear Sir, Thank you .Mera question ye he ki ,STP MBBR tank me SV-30 kitni honi chahiye or PH kitna honi chahiye , please answer me
If it helps you then you can review it on Google. Please share your experiences on Google.
g.page/r/CVcxcj5sxUuTEA0
Equilazation se areation tank me feeding Kitana hona chahiye
Hi Ajay,
Sabse pahle to aapko aapke aeration tank ka hydraulic retention time nikalna Hoga. hydraulic retention time ke bare mein janne ke liye aap channel per uploaded video hydraulic retention time dekh sakte ho. Uske bad aapko aapke plant capacity ke hisab se jo bhi aap equalization tank se aeration tank mein feeding karte ho uss feeding ko aapko 24 ghante ke hisab se barabar Bhag Mein bantana Hoga. let suppose Agar aap 24 KL feed karte hain to aapko 24 ghante se use divide karna hoga. yani ki aapko per Ghanta 1KL feed karna hoga.
Very good bro it's really helpful
Thanks dear stay connected ❤️
Parameters ke bareme batana sar..
Konse
Liquofaction plat ke baare mai bataye.
Bod ki leya dm water me air kis leye de jate h sir
Dissolved oxygen level badhane ke liye
Sur. Arrtion tank me d.a.p urea kyou dalte hai
To maintain nitrogen and phosphorus
Ek video anerobic etp ka banao
Dear sir.
Is Hardness reduction in DAP process of ETP is possible?....How
What is dap here?
Sir acidic efulent ko kese treat kren pH 1
Hmmm lime add kar do ph increase ho jayega aur phir agar 7 se jyda ho jaye toh hcl add karke
@@textiletech1638 after ading lime, primary settler require not not?
Or shall it send to directly to aeration tank ?
@@dnyaneshwarmanal5995 we need to settle sludge in primary then send to aeration tank
Sir vfa kaise nikalte h our lab testing process kaise hota h
Aeration tank me pH kom ho Jane se kaisa bohai
?????
Etp m biocalture ke kya jarurat h hmna to khi nhi dekha ye sab 10 years se
Bacteria (sludge) ko culture kahte hn...aur jab external culture (powder farm) se culture develope krte hn toh use bioculture khte hn.
sir etp me chrome ke liye konsa chemical use karte h
Chrome effluent ko effluent treatment plant mein treat karne ke liye aam taur par **sodium bisulfite (NaHSO₃)** ka upyog kiya jata hai. Yeh chemical hexavalent chromium (Cr⁶⁺), jo atyadhik vishaila hota hai, ko trivalent chromium (Cr³⁺), jo kam vishaila hota hai, mein badal deta hai. Yeh reaction aam taur par amliya vatavaran mein hoti hai, aur iske baad trivalent chromium ko chromium hydroxide (Cr(OH)₃) ke roop mein precipitate kiya ja sakta hai, jise solution ke pH ko chuna ya kisi anya kshar ke saath badhakar kiya jata hai.
Sir srt and mcrt and sludge blowdown calculation bataiye pleased
Holding tank me pH kam hone ke kya karan hai.
Holding time adhik hone se septic conditions bnti h jisse pH km hota h
Can you explain how to calculate dosing in ETP plant of poly, feso4, h2o2, fecl3, and urea and DAP in aeration tank
Yes please.. Same question
Yes same question
Sie ETP MBR Aabhi bhut foming kar raha he sir kaya Reagan ho saktha ...?
Sir COD high aaye to kya karna chahiye..?
Aeration tank ka DO range kitna hoga..?
Aerate tank ka DO high to kya karna chahiye...?
ruclips.net/video/h1F8FHrOlUo/видео.html
SIR, TOTAL AMONICAL NITROGEN JYADA HO JAYE TO KESE DOWN KARNEKA.
Thankyou sir well done,good job
If it helps you then you can review it on Google. Please share your experiences on Google.
g.page/r/CVcxcj5sxUuTEA0
Sir aration me bactiriya jldi growth kaise kre
DP water mein COD kyon badhati hai ise kaise control karenge
DP?
Sir BFA and alkalinity ke regards me bataya
new etp digram drawing milega kya
Yes... plz share the plant details and get quotation. Sanjeetrawat684@gmail.com
Aerobic or anaerobic plant mein kya Antar Hai bata sakte hain
ruclips.net/video/-oz7MPvzId4/видео.html
Sir ,hamara solvent plant hai ,tho use hum effluent ko neutral kar ke wo UASB Ko feed karte hai ,lekin uske baad hamara UASB distrub ho jaata hai,tho hame alag si solvent treat karne ka solution bataye
Solvent ko UASB me feed krne se phle... pretreatment krna jaruri hai... Oil grese ko remove krna jaruri h...COD ko balance krna jaruri h...Aap mujhe feeding effluent ke parameters bataen
Boiler feed water k liye cod or bod ki koyi standerd nhi h
Lekin aap jaanna chhate h to
1 ppm se below honi chaiye
Do u know the COD of DW??
@@ETPKnowledgeJunction yes...
@@ETPKnowledgeJunction
Sir DW ki cod to zero hoti h
I think you have some confusion
@@ETPKnowledgeJunction
May be..
But I want to know ...
Really what will be cod of DW
Turbidity kese check kare.tirbiditi kya hai
sir plx mustard oil water treatment par ek video bnaiye
Thanks Deepak.👍
plz mail on sanjeetrawat684@gmail.com . Plant process details and some photos and short videos bhejo.
Sir biological etp me paani clear karne ke aur ph maintan karne liye lime aur alum ke alava kya sulfamic powder use kar sakte hai kya aur dusra koi chemical honga to please batao
Mee plant pe bhi yek video banaye sir
Areation tank me effluent black kyu hota hai sir
Bod load badh jata hai ya DO km hota h ya culture km ho jata h jb... Aur bhi kai Karan ho sakte hn..
Join telegram group ETP Knowledge Junction and personally msg me on instagram iamsanjeetrawat.
Sir Kya ap hame anaerobic biogas digester ke pure anyalysis ke bare me Bata dijiye
Jaise Ki how to limit of caustic
How to limit of cod
Etc
How to make ppm dose
Sir hamare mlss groth nahi kar PA rahe hai
ruclips.net/video/uDmOwjY1sMo/видео.html
Sir what is organic load in Wastewater treatment?How to calculate it?
Sir etp m low ph chla gya pani ka colour change ho gya kaise thik hoga
Mee plant ka video banao
Thanks dear.. stay connected.
Chloride control kaise hota hai ETP se
ETP main career hain kya??
ETP PLANT ME TDS KAISE KAM KRE
Ro se
Sir, what is MLR in ETP process??
How to calculate etp plant capacity
You ae really doing a very great job Sir
Thanks please..stay connected
Mlss and mlvss kitna hona chahiye
DAP aur urea Kitna quantity me dalna hai MlSS banane ke liye
Plant disturb kese hota hai
Sir effluent se solvent kese nikale
There are many methods.. physical.. chemical
Sir airetion tan me setling nahi badh raha hai
Aeration tank me d.o. kitna hona chahiye sir
1.5 to 3ppm
Sir explain this etp plant in sugar mill
Aap kya jannaa chahte ho ..aap poochh sakte ho
Good explanations
Thanks dost... stay connected
We just getting too much foaming in Ctech basin nowadays. Just in a 10mins off short time. Please can we have a conversation on this. I'm tired of taking care of this situation. And actually right now due to covid lots of companies are stopped. So we're getting just 14-15 MLD water.
ruclips.net/video/zRmZ0y4UR70/видео.html
@@ETPKnowledgeJunction thank u so much sir!. Now I can took actions after observation.🥳
Bhai kitne pani m kitni doseg deni chahiye
Kiski
Sir ETP plant me colour ko remove karne ke liye Kya karte h
What happens to Areation black
Sir COD check krne ka process kya hota hai
You can join telegram group ETP Knowledge Junction
IS 3025 PART 58
Etp inlet water me pH kitana hota hai our outlet me kitana rahna chahiye
Inlet ka pH aapke process pr depend krta h lekin outlet ka 5.5 se 8.5 tk hona chahiyen
@@ETPKnowledgeJunction Thanks for the reply
Pharmaceutical Etp ke bare mein video banaye our jankari de please
Sir bacteria kaise Kam karta hai
Watch activated sludge process video
Water pond ki ph 2.5 aa rhi h sir kaise badhaye caoh2 se dissolved krne k baad 5.5 s jyada nhi aa rhi h sir please help
Water pond ...kya yah final treated water h?? Ya yah treatment ki kon si stage h?
No sir 2.5 acid mix water h treat krne k baad 5.5 se upar nahi ja rhi h water bhi black sa pad gya h
केमिकल प्लांट है
ट्रीट पानी में झाग बहुत आता है क्या करें कौन से केमिकल डालें बताओ सर
Hi Abhay,
Thanks for writing us. Aapko main batana Chahunga Pani Mein jhag tabhi bnta Hai Jab usmein pollution ki Matra hoti hai inlet Mein forming Hona Aam baat hai lekin Agar outlet treated water mein bhi forming ho rahi hai iska matlab hai vah Puri Tarah Se treat Nahin hua hai usmein abhi bhi suspended solids Honge aur vaha Pani turbid hoga kripya yah jaanch len ki aapka treated water Puri Tarah Se crystal clear Ho yani ki uske andar jo bhi BOD hai vah remove hui ho Thanks dear stay connected❤️
Sar ji namaste main ETP plant chalata hun sar ji 10.KL ka plant hai sar ji mere ko yah bataiye poli kitni dalni chahie chuna Kitna dalna chahie fitkari kitni dalni chahie 10 kilodi ka plant hai Pani Kala aata hai
Dost lab me sample leke jao... naap tol ke sample lo.. naap tol ke solution banao alam, poly aur lime ka.. uske baad settling shuru karo.. dekho ki kitne leter ya ml effluent ko settling karane me kitna chemical lga. Uske hisaab se plant me settling kro.
Sr etp all parmeter ka chart share kre with chart
Noted... please stay connected 🙏
Aeration tank me NH3N badjatahe uska upai bataiye
Ammonia kantrol less kare
etp में क्या क्या ध्यान देना चाहिए ?
Sab kuchh dost
Sir 1000 ltr water m kitna caoh 2 dale
Sir muje etp interview ko nikal na he to sir kyu app muche interview me puche chane Wale questions bata sakte ko
Fresher ke liye maine video bnai h... Aur ap meri baki ki videos bhi dekh sakte ho... Sari in formative hn... Aur cumminity tab pr questions dalta hu. ..
You can join telegram group ETP Knowledge Junction and personally msg me on instagram iamsanjeetrawat.
Sir.,
In my ETP there is jelly type biomass formed & also white foaming. What is reason for this jelly formation
The formation of jelly-like biomass and white foaming in an Effluent Treatment Plant (ETP) can be indicative of various issues in the treatment process. Here are some possible reasons and solutions:
**Possible Reasons:**
1. **Filamentous Bacteria Overgrowth:**
- **Reason:** Overgrowth of filamentous bacteria can lead to the formation of a jelly-like biomass.
- **Solution:** Adjust the microbial population by optimizing aeration, nutrient levels, and pH. Consider using specific microbial products to control filamentous bacteria.
2. **Nutrient Imbalance:**
- **Reason:** Imbalance in nutrient levels, particularly nitrogen and phosphorus, can contribute to biomass formation and foaming.
- **Solution:** Conduct a nutrient analysis and adjust the nutrient dosing to achieve a balanced nutrient ratio.
3. **Aeration Issues:**
- **Reason:** Inadequate or uneven aeration can lead to localized anaerobic conditions, causing foaming.
- **Solution:** Optimize aeration systems, check diffuser efficiency, and ensure proper mixing to maintain aerobic conditions.
4. **pH Fluctuations:**
- **Reason:** pH variations can impact microbial activity and favor the growth of certain organisms.
- **Solution:** Monitor and control pH levels within the optimal range for biological treatment.
5. **Organic Overloading:**
- **Reason:** High organic load can overwhelm the treatment system, leading to biomass overgrowth and foaming.
- **Solution:** Ensure that the influent organic load is within the designed capacity of the ETP. Consider adjusting the flow or implementing pretreatment if necessary.
6. **Presence of Surfactants:**
- **Reason:** Surfactants in the influent can contribute to foam formation.
- **Solution:** Identify and minimize the source of surfactants. Consider using antifoaming agents if necessary.
**Actions to Take:**
1. **Microbial Analysis:**
- Conduct a microbial analysis to identify the composition of the biomass and determine if specific types of bacteria are causing issues.
2. **System Optimization:**
- Optimize operational parameters, including aeration, pH, and nutrient levels, based on the characteristics of the wastewater.
3. **Foam Control Agents:**
- Consider using foam control agents or antifoaming agents to address excessive foaming temporarily while underlying issues are resolved.
4. **Regular Monitoring:**
- Implement a regular monitoring program to assess the performance of the ETP and make adjustments as needed.
Hi
BFA kya hota hai sir
It's VFA .. volatile fatty acids...plz wait video bn rhi h is pr
SIR ETP mai lime aaur midea kitne time baad change hone chaiye
BOD COD contarl Karna hi kasha hog
Samjha nahi dost
BOD ka load agar jada ho gya ho to kam kese kare
Aur sir chemical jaise colar bnane ke liye kitane ph,tds,bod,aur cod kitni honi chahiye
Sir
According to my experience I have seen more importance are given for production and very less importance given for waste water or etp and this section r directly related to public n environment
But day by day its demand increase due to gov. Regulations
Namaste sir mujhe ya Jaana Hai ki stp plant ke sbr me svi kitna se kitna tk hona chahiye
And mujhe vi Jaana Hai ki svi ko kese increase kiya jaye
Mera sbr me 150 Sv 30 hai but mlss 10560 ho jata hai kyou ki sewage ke sath send vi aa raga hai but fir vi koei to rasta hoga ki svi increase kese karu plz help me
Errietion ka inlet aur outlet COD kitna hona chahiye, pls riplay
Outlet ka standard h 250mg/l