ETP Q&A || sawal jawab ||

Поделиться
HTML-код
  • Опубликовано: 29 мар 2020
  • Hello guys the video is based on the questions you asked in comments section of various videos of science classes.
    #etpknowledgejunction
    #science_classes
    #sludge_volume_index
    #chemical_oxygen_demand
    #biochemical_oxygen_demand #Importance_of_BOD_and_COD #Wastewater_treatment #waste_water_treatment #activated_sludge_process
    #sanjeet_rawat
    #microorganisms_and_BOD
    #food_and_mass_ratio
    Watch the full videos and keep supporting the channel.
    Biochemical oxygen demand::
    • What is Biochemical ox...
    Standard procedure for analysis of mlvss and mlss::
    • Procedure of MLSS and ...
    Standard procedure for Analysis of Dissolve Oxygen::
    • Dissolved oxygen analy...
    Standard procedure for chemical oxygen demand::
    • Chemical oxygen demand...
    effluent treatment plant :: • What is Effluent treat...
    you can ask any question to us by social media and we will try to solve your queries so please follow us on social media.
    Stay tuned with the science classes by following on social media:
    Facebook:: / scienceclassesofficial
    Facebook Sanjeet Rawat::
    / sanjeet.rawat.7
    Instagram:: / iamsanjeetrawat (personal)
    / etpknowledgejunction
    facebook Group::
    / 154870968535789
    ________________________________________________
    •What is MLSS & MLVSS?
    •How to control COD?
    •What is SVI?
    •How to develop MLSS?
    •COD of Boiler feed water.
    •How to control excess foaming in aeration tank?
    •How to analyse high COD?
    •How to control floating sludge in secondary clarifier?
  • НаукаНаука

Комментарии • 390

  • @vaibhavpatil449
    @vaibhavpatil449 2 года назад +2

    Bohot hi badhiya aur helpfull video banaya hai sir ji aap ne thank you so much 💞 u n God 🙏 bless you

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 года назад

      Thanks dost... Stay connected with channel... Aap Facebook page pr bhi review de sakte ho ..❤️

  • @nebulaarts1639
    @nebulaarts1639 Год назад +1

    Good.Keep it up.👌👌

  • @sgm4324
    @sgm4324 3 года назад +1

    Thankyou sir well done,good job

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 года назад

      If it helps you then you can review it on Google. Please share your experiences on Google.
      g.page/r/CVcxcj5sxUuTEA0

  • @dnyaneshwarmanal5995
    @dnyaneshwarmanal5995 3 года назад +2

    You ae really doing a very great job Sir

  • @farhaankhan9184
    @farhaankhan9184 3 года назад

    I am really happy to your job

  • @Ajitsadangi4839
    @Ajitsadangi4839 6 месяцев назад +1

    U r have a good teacher ability

  • @manishgohil4900
    @manishgohil4900 3 года назад +1

    Sir what is organic load in Wastewater treatment?How to calculate it?

  • @prasadhande8310
    @prasadhande8310 4 года назад +1

    Sir fm ratio kaise calculate karte hai??

  • @patelhabib4692
    @patelhabib4692 4 года назад +2

    SIR, TOTAL AMONICAL NITROGEN JYADA HO JAYE TO KESE DOWN KARNEKA.

  • @veerpancheshwar6443
    @veerpancheshwar6443 Год назад +1

    Very good bro it's really helpful

  • @rajan1432r
    @rajan1432r Год назад +1

    Sir ek aap video banaye jisme
    Bod .cod .tds mlss jar testing ka

  • @farhaankhan9184
    @farhaankhan9184 3 года назад

    Sir I am working in a slaughter house.And I am working last 8 years in etp I want to ask you that what should tha dose of farric Alum and caustic cristal

  • @jigneshpatel1995
    @jigneshpatel1995 4 года назад

    COD ke liye phenolics components ke alawa aur kon konse matter effluent me rahte hai?

  • @kalyanighogarepatil7909
    @kalyanighogarepatil7909 3 года назад

    Sir
    According to my experience I have seen more importance are given for production and very less importance given for waste water or etp and this section r directly related to public n environment

    • @noor03250
      @noor03250 3 года назад

      But day by day its demand increase due to gov. Regulations

  • @sumityadav-yd4io
    @sumityadav-yd4io 4 года назад +1

    Sir agar testing k parameter k bar me bta do ki konsi testing se ky hota h kya fayada h kya nuksaam

  • @3207amit
    @3207amit 4 года назад +4

    Plz explain fm ratio calculation with example..

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 года назад

      ruclips.net/video/uuYHFK_Gvo0/видео.html
      Example in video description.

  • @VinodKumar-wy9ks
    @VinodKumar-wy9ks 3 года назад +1

    Sir please one video mak a BOD analysis with titertion please sir

  • @roshanrai2318
    @roshanrai2318 3 года назад

    If milky water come in sequence batch reactor then What can we do...
    Plz....rpy me sir

  • @vickramlondhe5440
    @vickramlondhe5440 Год назад

    Sir biological etp me paani clear karne ke aur ph maintan karne liye lime aur alum ke alava kya sulfamic powder use kar sakte hai kya aur dusra koi chemical honga to please batao

  • @sunilbhardwaj5252
    @sunilbhardwaj5252 3 года назад

    sir how to grow bacteria in aeration tank . i have bioculture powder

  • @rakeshdeshmukh7622
    @rakeshdeshmukh7622 4 года назад +1

    How to calculate etp plant capacity

  • @studyv3education789
    @studyv3education789 2 года назад

    Sir distillery me Mee plant ka condensate ke pane ko kese clear kerte hai

  • @Surendrayadav-gb2cf
    @Surendrayadav-gb2cf Год назад +1

    Please provided the interview questions for fermentation and distillation of alcohol industry

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  Год назад

      I don't have much idea about the industry...but you can join our telegram support group etp knowledge junction where many professionals are available to help you.

  • @nirmalkatiyar2486
    @nirmalkatiyar2486 3 года назад +1

    How to solve secondary clarifier sludge bulking

  • @devendrakumarsingh645
    @devendrakumarsingh645 4 года назад +1

    Sir srt and mcrt and sludge blowdown calculation bataiye pleased

  • @amitpayra1895
    @amitpayra1895 4 года назад

    Sir, secondary Clarifier may algae generate hona rukh na ka leay kya korna chi y

  • @vipinsingh5890
    @vipinsingh5890 4 года назад +2

    Ek video anerobic etp ka banao

  • @monuyogi25
    @monuyogi25 3 года назад +1

    Sir Etp plant ki capacity kese nikalte h

  • @purvanshvlog
    @purvanshvlog 3 года назад

    Sir aeration me air,DAP,Uriya air nitrogen ko kaise calculate karenge ki hamara Fooding sahi hi

  • @acharyadeepakthespiritual442
    @acharyadeepakthespiritual442 2 года назад +1

    Etp treatment water colour is white kya dosing kre

  • @nileshshelar2994
    @nileshshelar2994 2 года назад +1

    Good explanations

  • @pankajlohar1894
    @pankajlohar1894 4 года назад +1

    धन्यवाद सर
    खूप छान माहीती आहे 👍

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 года назад +1

      तुमि पन विचारू शकतो।

    • @pankajlohar1894
      @pankajlohar1894 4 года назад +1

      @@ETPKnowledgeJunction सर तुम्ही अजून विडिओ बनवत राहा , खूप शिकायला मिळतंय तुमच्या कडून तेही सोप्या भाषेत

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 года назад

      Thanks dear

  • @durgeshkumarshukla6137
    @durgeshkumarshukla6137 3 года назад

    Sir boilar water ke liye hadnes and cod,aur bod Kitna hona chahiye

  • @vijaymalik2892
    @vijaymalik2892 4 года назад

    Sir hamara water Ka kalar change nai ho ray ha ETP Ka Kish charge ke doging karni ha Jo kalar change ho jaya

  • @AshokKumar-gb5qp
    @AshokKumar-gb5qp 3 года назад +1

    Sir,Sludge is not settling in aeration and secondary clarifier please suggest

  • @MohdSajid-rl1fp
    @MohdSajid-rl1fp 3 года назад

    Sir meb hi 3 year she etp pe kam krta hu aur pura etp.chla sakta hu pr 12 pass hu pr me jana chahta hu kya etp kya koi coursh he 12 ke bad

  • @pradeepkushwaha8433
    @pradeepkushwaha8433 2 года назад

    Very nice sir

  • @prahladsinghchouhan2821
    @prahladsinghchouhan2821 3 года назад

    Sie ETP MBR Aabhi bhut foming kar raha he sir kaya Reagan ho saktha ...?

  • @sgm4324
    @sgm4324 3 года назад

    What's the indication of low do level ?

  • @durgeshkumarshukla6137
    @durgeshkumarshukla6137 3 года назад

    Aur sir chemical jaise colar bnane ke liye kitane ph,tds,bod,aur cod kitni honi chahiye

  • @nareshbollipo999
    @nareshbollipo999 3 года назад

    Sir plz how can chemical dosing monitering formulas secondry tertairy clarifires also plz tell me sir

  • @prasadhande8310
    @prasadhande8310 4 года назад

    Fm ratio kaise check kare??

  • @DeepakThakur-gt7pm
    @DeepakThakur-gt7pm 3 года назад

    Effluent m alum & poly ki dosing kitne % ki karte h

  • @aamirhussain8909
    @aamirhussain8909 4 года назад

    Very nise sir
    Sir g microbiology laboratory ka kuch topic

  • @umeshpatil5407
    @umeshpatil5407 3 года назад +2

    ETP main career hain kya??

  • @JitenderKumar-nj1ff
    @JitenderKumar-nj1ff 3 года назад +1

    Sir etp m low ph chla gya pani ka colour change ho gya kaise thik hoga

  • @faiyazkhan9569
    @faiyazkhan9569 Год назад

    Sir, what is MLR in ETP process??

  • @vaibhavpatil449
    @vaibhavpatil449 3 года назад +1

    High cod ko kaise down kare
    Please bataye sir

  • @dantanijagdishkumar3586
    @dantanijagdishkumar3586 4 года назад

    Sir doshing me lph ppm kese set karte he

  • @omveerkashayp8404
    @omveerkashayp8404 2 года назад

    Thanks ser

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 года назад

      You can join telegram group ETP Knowledge Junction and personally msg me on instagram iamsanjeetrawat.

  • @sachingaikwad9964
    @sachingaikwad9964 4 года назад +2

    Sir safety diploma regular or external matter krta hai kya in professional life or in starting of career

  • @nandannandan9880
    @nandannandan9880 2 года назад

    Namaste sir mujhe ya Jaana Hai ki stp plant ke sbr me svi kitna se kitna tk hona chahiye
    And mujhe vi Jaana Hai ki svi ko kese increase kiya jaye
    Mera sbr me 150 Sv 30 hai but mlss 10560 ho jata hai kyou ki sewage ke sath send vi aa raga hai but fir vi koei to rasta hoga ki svi increase kese karu plz help me

  • @Itspradeepgore_01
    @Itspradeepgore_01 3 года назад

    Hi sir
    Mai distilleries biogas chemist ke pad pr work kar rha hu pr muze biogas ke process ke bare me Puri jankari chahiye
    Aur ek bat kya etp ke liye koi deploma hai

  • @amarjeetram4909
    @amarjeetram4909 3 года назад

    Sir Aertion tank ka pani thora mota ho gaya hai aur chip chip karta he
    eska kya reason ho sakta hai

  • @Itspradeepgore_01
    @Itspradeepgore_01 3 года назад

    Sir Kya ap hame anaerobic biogas digester ke pure anyalysis ke bare me Bata dijiye
    Jaise Ki how to limit of caustic
    How to limit of cod
    Etc

  • @farhaankhan9184
    @farhaankhan9184 3 года назад +1

    Sir ek video bnaye jisme harek tank ke bare mai detail mai btaye jaise har tank ka hrt kiya hai kon sa bacteria hai kiya parameters hone chiye har ek tank ka kiya kaam hai

  • @mryunuskhan1990
    @mryunuskhan1990 4 года назад

    What is aerobic and Anaerobic process.?

  • @nareshbollipo999
    @nareshbollipo999 3 года назад

    Sir plz explani vfa procedure

  • @sandeepbadgujar1995
    @sandeepbadgujar1995 3 года назад +1

    Mee plant pe bhi yek video banaye sir

  • @guruji8390
    @guruji8390 Год назад

    How to make ppm dose

  • @SunilSingh-lu4oy
    @SunilSingh-lu4oy 9 месяцев назад

    Sir airetion tan me setling nahi badh raha hai

  • @DharmendraSingh-zm8jh
    @DharmendraSingh-zm8jh 4 года назад

    Cod me jitne bhi chemical hotel hai. Wo Kam Kya large hai.

  • @maheshprajapati5515
    @maheshprajapati5515 3 года назад

    Sir vfa kaise nikalte h our lab testing process kaise hota h

  • @ankurjaiswal9626
    @ankurjaiswal9626 3 года назад

    Liquofaction plat ke baare mai bataye.

  • @sandeepbadgujar1995
    @sandeepbadgujar1995 3 года назад

    Chemical etp me high cod ko control kaise kare

  • @sachinsharma-zc2bx
    @sachinsharma-zc2bx 3 года назад +1

    Provide process of ETP aerobic system with proper define function of ph cod bod mlss mlvss SLI fm ratio DO level and jar rest

  • @RUSHABH8460290014
    @RUSHABH8460290014 3 года назад +1

    Can you explain how to calculate dosing in ETP plant of poly, feso4, h2o2, fecl3, and urea and DAP in aeration tank

  • @sagarsalunkhe5859
    @sagarsalunkhe5859 2 года назад

    What happens to Areation black

  • @kapilvashiasta1906
    @kapilvashiasta1906 2 года назад +1

    Sir etp plant design kaise krte h. Par bhi video banoaao

  • @Ajitsadangi4839
    @Ajitsadangi4839 6 месяцев назад

    Etp ko sikhne ke kya jan na important hai.. please reply

  • @ketanmohite7401
    @ketanmohite7401 2 года назад +1

    How design stp and etp plant...?

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 года назад

      First we have to master in wastewater management. Have to know about all the process deeply. This is so simple 😊
      If you are a professional, we can work together. sanjeetrawat684@gmail.com
      .
      .
      Join telegram group ETP Knowledge Junction and personally msg me on instagram iamsanjeetrawat

  • @Meet-ef1jr
    @Meet-ef1jr 4 года назад

    Hlw sir me 12th ke bad DDT diploma in dairy tech. Kiya hua h ignou se or ignoue se hi BA kiya h to me puchna chahta hu is line me age badne ke liye or kya kar sakte h safety diploma usko kare kya plz is barr me btaye ge to help hogi kafi me kafi presaan hu sir apne future ko leke or ye bhi btaye agar ek jagh kam karke futur nhi najar a rha h is line me to jump kare kisi or plant me job search kre isi line me tell me

  • @manojdhumal9530
    @manojdhumal9530 4 года назад +1

    Nice sir

  • @Mindblowinganuj
    @Mindblowinganuj 3 года назад +1

    Sir 1000 ltr water m kitna caoh 2 dale

  • @sanjaykumarrewadia8556
    @sanjaykumarrewadia8556 4 года назад +1

    sir Kya mbbr technology me sludge re circulars hota h or kyo

  • @devkinandandumka3312
    @devkinandandumka3312 2 месяца назад

    SIR ETP mai lime aaur midea kitne time baad change hone chaiye

  • @ramawtar6172
    @ramawtar6172 3 года назад +2

    Sir E.T.P ka D.O.test karane keliye ham khan se water lekar test kara shakte hai aur D.O. ka full form bataye

    • @Rashid7645
      @Rashid7645 3 года назад +1

      Water airation tank mai kahi se bhi sample le skte hai Kyunki yh poore tank mai hota hai and DO means Dissolve oxygen

  • @dipakkhatri3581
    @dipakkhatri3581 2 года назад +1

    Who to control Aeration tank outlet sample turbidity?

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 года назад

      Hi dipak...
      Dedicated video on turbudity is there in Playlist. And stay connected..

  • @AnupKumar-tt2xc
    @AnupKumar-tt2xc 3 года назад

    COD kon sa tank mai Kam hota hai

  • @yraut730
    @yraut730 3 года назад

    Air tank kitana time off rakh sakte he 8 h

  • @ShaileshKumar-wl2hl
    @ShaileshKumar-wl2hl 3 года назад +1

    Sir explain this etp plant in sugar mill

  • @DharmendraSingh-zm8jh
    @DharmendraSingh-zm8jh 3 года назад +1

    Sir BFA and alkalinity ke regards me bataya

  • @hirendranikose1928
    @hirendranikose1928 2 года назад

    Sir ye trade kaha se karte

  • @anupmajhi6961
    @anupmajhi6961 2 года назад

    Sir ! Main is company Mai Naya Aya hoon aur yaha ka Areation ka colour black aur becterialess hai to kya hum Areation tank ko Khali karke fresh pani bharkar usko cow dung ,juggery, ka dosing load karke becteria devlop ho sakega ?

  • @pankajkumar2210
    @pankajkumar2210 3 года назад

    Sir etp me others country me bhi job mil jati hai kay

  • @dkyadavji7813
    @dkyadavji7813 3 года назад

    Sir aration me bactiriya jldi growth kaise kre

  • @jigarbaria2293
    @jigarbaria2293 2 года назад +2

    Sir can you please share the formula for blower selection and how to decide number of diffusers to be installed in aeration tank.

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 года назад

      Hi dear.. you can watch meenu Jain Lalitpur video on RUclips.. about calculation of aeration system. Or join telegram group ETP Knowledge Junction

  • @ganeshware8057
    @ganeshware8057 4 года назад +1

    Sir ,hamara solvent plant hai ,tho use hum effluent ko neutral kar ke wo UASB Ko feed karte hai ,lekin uske baad hamara UASB distrub ho jaata hai,tho hame alag si solvent treat karne ka solution bataye

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  4 года назад

      Solvent ko UASB me feed krne se phle... pretreatment krna jaruri hai... Oil grese ko remove krna jaruri h...COD ko balance krna jaruri h...Aap mujhe feeding effluent ke parameters bataen

  • @tinu-hb3lz
    @tinu-hb3lz 2 года назад +1

    Dear sir.
    Is Hardness reduction in DAP process of ETP is possible?....How

  • @MusicdilseJaiShreeRam
    @MusicdilseJaiShreeRam 4 года назад +3

    Dear Sir, Thank you .Mera question ye he ki ,STP MBBR tank me SV-30 kitni honi chahiye or PH kitna honi chahiye , please answer me

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 года назад

      If it helps you then you can review it on Google. Please share your experiences on Google.
      g.page/r/CVcxcj5sxUuTEA0

  • @AnupKumar-tt2xc
    @AnupKumar-tt2xc 3 года назад

    TDS kaha kam hota hai sir

  • @hardiksinhdodiya6561
    @hardiksinhdodiya6561 3 года назад +1

    Hypo &poly &allum used Etp

  • @ankitkumarmishra4669
    @ankitkumarmishra4669 2 года назад +1

    Sir COD high aaye to kya karna chahiye..?
    Aeration tank ka DO range kitna hoga..?
    Aerate tank ka DO high to kya karna chahiye...?

  • @kiranbaria4111
    @kiranbaria4111 Год назад

    Turbidity kese check kare.tirbiditi kya hai

  • @vijaybhan8202
    @vijaybhan8202 3 года назад +1

    Mlss and mlvss kitna hona chahiye

  • @shridharvyas1511
    @shridharvyas1511 3 года назад +1

    thanks nice information can you suggest some articles or books that give a complete description of the complete process of an ETP whether to small or big one

    • @PAWANKUMAR-ln9mi
      @PAWANKUMAR-ln9mi 3 года назад

      Coke plant me etp ka kya process hai

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 года назад

      If it helps you then you can review it on Google. Please share your experiences on Google.
      g.page/r/CVcxcj5sxUuTEA0

  • @narpatsingh7052
    @narpatsingh7052 3 года назад

    Etp kitne stage par hota hai

  • @vishwakarmasound6151
    @vishwakarmasound6151 2 года назад +1

    Sir muje etp interview ko nikal na he to sir kyu app muche interview me puche chane Wale questions bata sakte ko

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 года назад

      Fresher ke liye maine video bnai h... Aur ap meri baki ki videos bhi dekh sakte ho... Sari in formative hn... Aur cumminity tab pr questions dalta hu. ..
      You can join telegram group ETP Knowledge Junction and personally msg me on instagram iamsanjeetrawat.

  •  7 месяцев назад

    Sir.,
    In my ETP there is jelly type biomass formed & also white foaming. What is reason for this jelly formation

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  7 месяцев назад

      The formation of jelly-like biomass and white foaming in an Effluent Treatment Plant (ETP) can be indicative of various issues in the treatment process. Here are some possible reasons and solutions:
      **Possible Reasons:**
      1. **Filamentous Bacteria Overgrowth:**
      - **Reason:** Overgrowth of filamentous bacteria can lead to the formation of a jelly-like biomass.
      - **Solution:** Adjust the microbial population by optimizing aeration, nutrient levels, and pH. Consider using specific microbial products to control filamentous bacteria.
      2. **Nutrient Imbalance:**
      - **Reason:** Imbalance in nutrient levels, particularly nitrogen and phosphorus, can contribute to biomass formation and foaming.
      - **Solution:** Conduct a nutrient analysis and adjust the nutrient dosing to achieve a balanced nutrient ratio.
      3. **Aeration Issues:**
      - **Reason:** Inadequate or uneven aeration can lead to localized anaerobic conditions, causing foaming.
      - **Solution:** Optimize aeration systems, check diffuser efficiency, and ensure proper mixing to maintain aerobic conditions.
      4. **pH Fluctuations:**
      - **Reason:** pH variations can impact microbial activity and favor the growth of certain organisms.
      - **Solution:** Monitor and control pH levels within the optimal range for biological treatment.
      5. **Organic Overloading:**
      - **Reason:** High organic load can overwhelm the treatment system, leading to biomass overgrowth and foaming.
      - **Solution:** Ensure that the influent organic load is within the designed capacity of the ETP. Consider adjusting the flow or implementing pretreatment if necessary.
      6. **Presence of Surfactants:**
      - **Reason:** Surfactants in the influent can contribute to foam formation.
      - **Solution:** Identify and minimize the source of surfactants. Consider using antifoaming agents if necessary.
      **Actions to Take:**
      1. **Microbial Analysis:**
      - Conduct a microbial analysis to identify the composition of the biomass and determine if specific types of bacteria are causing issues.
      2. **System Optimization:**
      - Optimize operational parameters, including aeration, pH, and nutrient levels, based on the characteristics of the wastewater.
      3. **Foam Control Agents:**
      - Consider using foam control agents or antifoaming agents to address excessive foaming temporarily while underlying issues are resolved.
      4. **Regular Monitoring:**
      - Implement a regular monitoring program to assess the performance of the ETP and make adjustments as needed.

    • @sahidurzzaman7266
      @sahidurzzaman7266 6 месяцев назад +1

      Hi

  • @deepaksoni4848
    @deepaksoni4848 2 года назад +1

    sir plx mustard oil water treatment par ek video bnaiye

    • @ETPKnowledgeJunction
      @ETPKnowledgeJunction  2 года назад

      Thanks Deepak.👍
      plz mail on sanjeetrawat684@gmail.com . Plant process details and some photos and short videos bhejo.