हिन्दी में, Media Fill Failure Investigation in Hindi @PHARMAVEN #media #aseptic #pharma #usfda
15:46
हिंदी में: All About Media Fill in Aseptic Processing #media #aseptic @PHARMAVEN#usfda #sterile
25:42
हिन्दी में पार्ट 2, Media Fill Failure Investigation
HTML-код
- Опубликовано: 12 сен 2024
हिन्दी में, Media Fill Failure Investigation in Hindi @PharMaven #media #aseptic #pharma #usfda
Thanks for information 👍👍👍
Sir ase hi hindi me our video banate rahe hame parfect samaj me aata he
Nice video and content
Very nice
Very nice sir
Well explained sir 👏 👌
Superb sir ji
Well explained sir
Good Information
Thanks, please also share to more friends
sir Ek video microbial limit test or Raw materials and finish product bano🙏
Sir Please make video on Container closure integrity.
sir hama personnel monitoring ke video chiya
Ccit...when require
What may be the reason initial and end stage media fill vials pass but middle stage failed ?
Many reasons
1. Any intervention which was not executed properly
2. New intervention
3. Air flow not maintained
4. Opening filling machine door
5. Differential pressure low
6. One of component, such as rubber stoppers or vials not properly sterilized
7. New operator introduced without proper aseptic Processing training
8. NVPC count increased
9. Any component such as filling needle, syringe, tubing or connection changed