HOW TO WIRE AND PROGRAM ELIWELL ID974 DIGITAL CONTROL OF COMMERCIAL REFRIGERATORS(TAGALOG)
HTML-код
- Опубликовано: 2 ноя 2019
- Tara lahat ng RAC ASPIRANTS, iprogram at iwiring natin ang nabanggit na control. Wag po tayo magfocus sa aircon lamang, try studying Refrigeration too para mas malaki ang $$$ mo. Kung mayroon po kayong katanungan just write it down po sa comments section.
Part 1- Programming eliwell id974
Part 2- Wiring tutorial
#EliwellId974
#RefrigeratorDigitalControl
#OCTTV
My other tutorial videos: • Tutorials on Refrigera...
Funniest Comedy Videos
• Playlist
The creator is a topnotcher in Consumer Electronics and in Refrigeration and Air-conditioning, a certified Welder (smaw), Diesel Mechanics, Cellular phone Servicing,and an experienced Computer Technician. Наука
This tutorial is intended for RAC aspirants at iba na allowed mag adjust or mag calibrate ng mga commercial refrigerator nila. Reprogramming at wiring is being discussed here.
Galing niyo po mag tutorial!salamat sa pag share
Sana nakatulong po. Ty din po sa panonood
Galing master mabuti nakita ko ang mga video mo
ruclips.net/p/PLOMYgMklNMhF8NP3aD97DgeB3pk_kJtFX dyan sir naka playlist na po para sa lahat ng ibig umangat sa refrigeration. Programming at pcb repairs din po
Thanks
Me gantan din akong controller medyo mahirap ng konti iprogram pero maganda din yan. Yung AKO ay simpke at user friendly
Sa abot ng makakaya ko sir, share ko sa mga katech natin about control both programming and control repair. Hiling ko lang na isubscribe nila channel ko para kung mahit ko na requirements ni youtube ay mawawala na ang annoying ads sa mga tutorials ko.
boss pwede b yan sa water heater ng auto dishwashing machine? nasira n kc ang analog thermostat at balak ko paltan ng digital pra may temperature display.... paano po iba bypass ang defrosting? thanks po sa reply
Wag mo ng ibypass sir, used eliwell ic 901 instead kasi single sensor lang sya at mayroon parameter for heat/cool.
Kung chiller use cool, if heater naman like ng dough proofer namin use heat. At kaw na bahala sa setting temperature ng diswashing mo. Sa dough kasi namin is 35-38 °c lng
How to program and wiring, If i connect to power ampli audio for sirine & strobo?
Many thank before 🙏
This is design only for heating and cooling my friend. For the power output it can drive 220v / 8 amp but need to sense heat or cool to start. Otherwise an error occure. Try motion/clap sensor
galing tala ng technician na to henyo
Arigato maduma. Share po natin para madaming kababayan natin ang matuto sa larangan ng Refrigeration
Hello what 's about PA1 in the screen? I can't do nothing
Go to "diS" label and proceed to LOC parameter, from there change Y to N.
At this time your Eliwell id974 is unlock.
Now scroll down and change PA1 parameter to O which is the default value.
Good luck my friend!
E2 blinking and alarm how solve this problem
Replace evaporator sensor sir
Hello sir panu ba iset ang fan, kc pag nag automatic na xa nareach nya temp.
Set, mag off n compressor nag off dn evap. Fan.. paanu ba iset na nd nMmatay ung evap. Fan. Nawawla kc display ng fan sa eliwell pag nag automatic.
Gawan po natin ng tutorial natong mo po sir. Tama andito pa eliwell controller ko sir
Cge sir, waiting po
ruclips.net/video/9xZMaT3H6ZE/видео.html yan na po sir alfe
Meron ako ginagawa nag defrost lang hindi na nag frost ang chest freezer, malamig lang hindi nman nagalaw ang temp. Digital control
Recovery po usually 30mins to 1 hr yan sir
Paano po mag set sa eliwell para Po sa 2pcs na 1000 w na heater
Gamit ka contactor boss👉ruclips.net/video/zWfkYZFeJwY/видео.html watch po yan although dixell sya magkakaidea ka po
Kabayan paano po eset ang eliwell id plus 974..for freezer
Ala kaming ID PLUS model boss. Exaggerated po if sasagutin natin yung di na tackled. Pero sa DEI meron syang parameter for reset.
@@THEMULTISKILLEDTECH mayron nga po syang parameters sobrang dami nya tapos tumingin aq sa mga yutube same model yong pag set nila tiningnan q may nag iba..sundin q nlang ang parameters nito kabayan nasa 31 lahat bago matpos ang pag set..
Fan not activeted in digital controller what is the reason...? What to do?.
Check output 220v from internal relay if you saw evaporator fan is being engage at display sir.
Sir mor power po. Ask ko lng po san po ba available mka bili niyan sa pinas?
Try lazada po sir
@@THEMULTISKILLEDTECH sir thank you sa kaalaman. More power .
Sir,pag sira po b ang digital LAGI po bng namamatay ang compressor?
Hindi po Kasi pumupunta ang current papuntang compressor..aandar man 1 second. LNG,,tpos na 0000 ung digital..paki sagut nman po me sir,tnx...
Possible sir
ruclips.net/video/ynF1rFsMsQM/видео.html ⬅️ try mo watch to sir/tukayo baka makatulong sa problema mo. Kung paano ayusin ang control same issue sa problema mo sir.
Master anu po problem ng walk in frezzer umaandar nman lahat kaso alang lamig...at panu tanggalin yung nagblink na alarm.
Ano alarm nya sir?
@@THEMULTISKILLEDTECH dko pa alam sir baguhan lng kc..
@@raymundestocapio4683 ang mga alarm ng eliwell id974 ay e1, e2, ah1, al1, ad2 alin sa mga yan sir?
Ah1 pla sir.. salamat..
Could you please show me how to change fahrenheit to celsius on eliwell digital
Go to parameter dro sir and select zero (0) to shift for degrees Celsius. Ty
Puide po b sa egg incubator?
Eliwell IC902/lae po sir pwede kasi mayroon parameter sya pang heat or cool mode.
@@THEMULTISKILLEDTECH yan po eliwell 974 di po sya pede kahit kaya nya ma read hanggang 50 degree celsius
Eto mga sir My Diy egg incubator using dixell temperature control 👇ruclips.net/video/dZa95RCQpZE/видео.html