Home Automation 32CH Distribution Board DIY Smart Home IOT Project 2020

Поделиться
HTML-код
  • Опубликовано: 15 авг 2024

Комментарии • 454

  • @KinCony
    @KinCony  Год назад

    ruclips.net/video/Ae4CDMBKRwA/видео.html this is 2023 newest smart distribution board DIY video tour, have diagram download link in video description.😀

  • @darioampuy
    @darioampuy Год назад +27

    i would suggest for the next project, use a busbar instead of daisychaining the breakers... it's cleaner and safer. the only negative point in busbar is that you have to replace the busbar is you want to expand the circuit... havn't seen expandable busbars so far

    • @KinCony
      @KinCony  Год назад +1

      yes, thanks for your suggestion, next project will improve it.

    • @pedroveloso9707
      @pedroveloso9707 Год назад +1

      yeapp... busbar, and normal wire to the connection off the drivers, small secction. great job never the less :)

    • @pedroveloso9707
      @pedroveloso9707 Год назад

      one more thing, 25A, and 2.5 wiring you are on the edge off it. better 16A to that wire section

    • @KinCony
      @KinCony  Год назад

      @@pedroveloso9707 thank you

    • @KinCony
      @KinCony  Год назад

      @@pedroveloso9707 ok, thanks.

  • @Willeexd1337
    @Willeexd1337 Год назад +8

    Good idea for a project but you shouldn't really connect stuff like this. Daisy chaining the contactors like that will overheat if you draw a big current, use a busbar instead and split the circuit into different sections. So you use maybe 4 busbars with 4 wires from the main fuse to split up the load in the wires. The fuse should be before the contactor to protect it as well because those can't handle 63A like the main breaker is rated for. This is no hate its just some constructive criticism from someone who is a Automation engineer.
    edit: spelling error, English isn't my main language

    • @KinCony
      @KinCony  Год назад +1

      thank you very much for your suggestion, we will make new video tour based on new controller and solution, it will be improved.

    • @Willeexd1337
      @Willeexd1337 Год назад

      @@KinCony Nice! Looking forward to it :)

    • @KinCony
      @KinCony  Год назад

      @@Willeexd1337 thanks.

  • @ronross4288
    @ronross4288 Год назад

    Ron Ross, I am a Principal Design Engineer for a Large Utility in the US. I just turned 67 and I will be retiring. I would like to add comments for improving your panel. I realize that this may be copied by others. I am not sure of the color code used but the hot wire here is black. White is used for the neutral and green for the ground wire. As I understood your control layout, the relays powered the circuit breakers which then fed the output to the circuits. The main breaker in the panel limits the internal and downstream circuits by its rating. I did not count the breakers, but I believe you had 32 at 25 Amp each. The main is maybe 63 amp? two pole. We do not break the neutral of white wire with a breaker in the US. If you are going to use a main breaker, it should be larger, maybe 100 amp. Also, you need to group the power runs in groups of 5 from the main. You are feeding them all with the same wire. The din rail under the relays and the breakers should have a screw thought the mounting plate about every six inches.

    • @KinCony
      @KinCony  Год назад

      Thank you very much for your valuable advice, this video made by two years ago, this month we have made a new solution video tour, i think you will love it. ruclips.net/video/Ae4CDMBKRwA/видео.html how about this solution?

  • @Broadcast1Channel
    @Broadcast1Channel Год назад +12

    Anyone viewing this please do not use this as a guide. Get in contact with a qualified electrician and find out how it should be done.

    • @frikkied2638
      @frikkied2638 Год назад

      Wtf why? This is a super clean build.

    • @chunchun722
      @chunchun722 Год назад

      ​@@frikkied2638cuz sometimes viewer copying the video and doing it wrong

    • @cedricschoemans5214
      @cedricschoemans5214 9 месяцев назад

      Yes, but if you don't know what you're doing you can make some mistakes and that can put you and your house in danger when you try to connect with the power

  • @PHUC_DOHUU
    @PHUC_DOHUU Год назад +8

    As a control and distribution cabinet, you should distinguish and specify the wire color, usually red wire for phase, black wire for neutral, green/yellow wire for ground, signal control wire is a small wire and also distinguished by wire color and the ends of the wire are the heat-generating contacts, so the presser should be used.

    • @KinCony
      @KinCony  Год назад

      thanks for your suggestion, we are designing another new solution.

    • @dpsmoin2151
      @dpsmoin2151 Год назад

      good think!

    • @dpsmoin2151
      @dpsmoin2151 Год назад

      Distribution cabinet use the cable only fire alarm cable.

    • @KinCony
      @KinCony  Год назад

      @@dpsmoin2151 how about this style? ruclips.net/video/Ae4CDMBKRwA/видео.html

    • @waoooSky
      @waoooSky Год назад

      @@KinCony waiting new design so

  • @henkhakkertoene
    @henkhakkertoene Год назад +3

    shouldn't the wire be thicker when the fuse is only 63 amps ?

    • @KinCony
      @KinCony  Год назад

      yes, this demo, not use full of load current.

  • @anoyarhosenmondal5205
    @anoyarhosenmondal5205 2 года назад

    Sair very very nice video and easy proses to learning

  • @firsteerr
    @firsteerr 7 месяцев назад +1

    can that 4mm singles take the sixty to 100 amps you will be drawing through it ?

    • @KinCony
      @KinCony  7 месяцев назад

      ruclips.net/video/Ae4CDMBKRwA/видео.html this is 2023 newest smart distribution board DIY video tour, have diagram download link in video description.😀

  • @mohammadsaifkamal1468
    @mohammadsaifkamal1468 Год назад +1

    Good sir 🇮🇳🇮🇳🇮🇳

  • @gustavocalderon8153
    @gustavocalderon8153 3 года назад +2

    Thanks a lot KinCony. Amazing job. I Will be waiting the second video of this Electrical WiFi Control Panel.

    • @KinCony
      @KinCony  3 года назад +5

      if want to use wifi, just replace the controller with KC868-H32B is ok

  • @paulbell7654
    @paulbell7654 Год назад

    Death trap in a box! No separation of mains and low voltage. No earthing or bonding. Main switch feeding contractors without circuit protection. Undersized cables. RF devices installed inside a metal box - thanks for demonstration of what not to do.

    • @KinCony
      @KinCony  Год назад

      next version will all improve

  • @user-nt4ie4iv6l
    @user-nt4ie4iv6l Год назад

    Very good

  • @ekesmanaffiliate9308
    @ekesmanaffiliate9308 2 года назад

    I really appreciate your efforts in educating the world with innovations.
    Home automation has always been my dream career.
    Will you be my direct mentor?

    • @KinCony
      @KinCony  2 года назад

      thanks, any question need help just leave message. we will help everyone.

    • @BTW...
      @BTW... Год назад

      SRSLY?

  • @shashikantmarskole
    @shashikantmarskole Год назад +1

    nice work, love it. thank u

  • @barycza
    @barycza Год назад +1

    No commentary - annyoing music in background instead. It tells everything about your channel quality.

    • @KinCony
      @KinCony  Год назад

      next video will have voice explain.

  • @oaba201
    @oaba201 Год назад

    Busbar (Splited (Not one large!!!!)) Clean the paint under the earth strap!!! I would put an earth strap between the back panel and box too. Labels. Larger neutral distribution bar. And earth distribution bar too. Wiring diagram on the inside of the door. I would put a switch on the front door. That does not allow the door to be opened while the switch is ON.
    The wire color might OK in your Country. EU IEC 60445:2021
    Might you want cabinet lighting as well?

    • @KinCony
      @KinCony  Год назад

      thanks for your suggestion. this is our new solution: ruclips.net/video/Ae4CDMBKRwA/видео.html this is better.

  • @SrPachaman
    @SrPachaman Год назад +1

    This is beautiful ❤

  • @EliasAwandaOduor
    @EliasAwandaOduor 11 месяцев назад

    This nice

  • @aglmbranagahmaddghabibah3573
    @aglmbranagahmaddghabibah3573 5 месяцев назад

    Selamat pagi bos db gn dlm nya cantik gn kemas cuma ada lg kurang dlm db book tu tidak ada kipas pendingin haba panas untuk pcb bot control nya kalau tidak ada kipas pendingin udara apabila pcb bot tu nanti panas cepat rosak sebap panas alat elektronik pcb nya pasti tidak akan tahan lama gn cepat rosak jadi mesti kena letak kipas bos 😊🇲🇾

    • @KinCony
      @KinCony  5 месяцев назад

      thanks for suggestion.

  • @rickymeadows5176
    @rickymeadows5176 Год назад

    Beautiful work !

  • @abbarrukhanelectricandplum1750

    butyfull video

  • @DeKempster
    @DeKempster Год назад

    Strange way of mounting the din rail. Why multiple pieces in the same row. Self tapers are also much easier. Good videos non the less, always interesting how people make cabinets in other countries.

    • @KinCony
      @KinCony  Год назад

      thanks for suggestion.

  • @wiratno6612
    @wiratno6612 3 года назад +1

    this video is in accordance with my hobby.can the manual switch button be replaced with a touch switch?thank you.

    • @KinCony
      @KinCony  3 года назад

      already can extend connect with wall switch. the black button inside of AC contactor only for emergency use.

    • @BTW...
      @BTW... Год назад

      @@KinCony No, it's for isolation and bypassing control signals when testing.

    • @KinCony
      @KinCony  Год назад

      @@BTW... if use bypassing control, will use COM,NC,NO will be very large space.

  • @siderminerkgl8193
    @siderminerkgl8193 Год назад

    Do you love to tidy stuff in casings?
    Do you like building robust mechanisms?
    Do you also like tech?
    Say hello to embedded systems engineering or embedded systems!

  • @ASHOK-ob3yu
    @ASHOK-ob3yu Год назад

    Hi nice

  • @prashantdawar
    @prashantdawar Год назад

    Awesome work

  • @shahzoddehqonov4935
    @shahzoddehqonov4935 Год назад +1

    Thank a lot of

  • @MrRajSood01
    @MrRajSood01 3 года назад +1

    Big fan of your work !!! Keep up the
    Good work

    • @KinCony
      @KinCony  3 года назад

      thanks, we will make more interesting applications

    • @BTW...
      @BTW... Год назад

      Seriously?

    • @richardswairg3695
      @richardswairg3695 Год назад

      @@BTW... give him a break bro he said he made this project for fun 😅

    • @BTW...
      @BTW... Год назад

      @@richardswairg3695 Lets say... between the two.. a 'how to' DIY no idea 20kg batch of black powder fireworks, stored in every room of the house, or this 'how to' DIY no idea mains voltage (240V AC 40A @ 10kA pfc) switchbox fireworks, permanently connected to a home or commercial building.
      Now, what do you think would be more fun and safer?
      ...and it follows, Do you think demonstrating either of these highly dangerous 'DIY fun' things is suitable for RUclips promotion?

  • @lameckobiero3160
    @lameckobiero3160 Год назад

    i like the work,can this be used in offices

    • @KinCony
      @KinCony  Год назад

      sure, no problem

  • @AalimOnlineOfficial
    @AalimOnlineOfficial Год назад +1

    7:11 why you did multi looping?

    • @KinCony
      @KinCony  Год назад

      Load diversion for safer operation

    • @AalimOnlineOfficial
      @AalimOnlineOfficial Год назад

      Multi looping is prohibited in good designs

    • @KinCony
      @KinCony  Год назад +1

      @@AalimOnlineOfficial thanks for suggestion.

  • @MatSmithLondon
    @MatSmithLondon 3 года назад +4

    I really like this work. Have you manufactured smart dimmers, like triac dimming or for LED light?

    • @KinCony
      @KinCony  3 года назад +1

      i am dimmer, you can see this video: ruclips.net/video/cKgbX8nO0jQ/видео.html

    • @MatSmithLondon
      @MatSmithLondon 3 года назад +1

      @@KinCony Thank you! Do you have a triac dimmer as well (for incandescent or other lights)?

    • @KinCony
      @KinCony  3 года назад +1

      yes, we have, KC868-D8 + SSR is ok, i will make video later.

  • @darkshadowsx5949
    @darkshadowsx5949 3 месяца назад

    why would someone want a PLC for their house? whats so tedious that you would want to automate?
    does it wash the dishes, do your laundry, mow the yard, and cook for you?
    No? what the point then?
    automating lights isn't worth the cost.

  • @metamud8686
    @metamud8686 Год назад

    5:05 if you put those remote units in an all metal enclosure, won't that make for poor reception due to them being inside a Faraday cage?

    • @KinCony
      @KinCony  Год назад

      mainly use by ethernet, not use by wifi.

  • @Jumman_Hossen
    @Jumman_Hossen Год назад

    Good

  • @omumaro
    @omumaro Год назад

    Why do you use C breakers and not B?

    • @KinCony
      @KinCony  Год назад

      mainly use for light. here is our new solution: ruclips.net/video/Ae4CDMBKRwA/видео.html this is improvement.

  • @Alexander-dv9vx
    @Alexander-dv9vx Год назад

    Мне кажется мягким проводом монтаж был бы намного проще, быстрее и надежнее. Идея хорошая, исполнение на 3.

    • @KinCony
      @KinCony  Год назад

      thanks for suggestion, this is the newest solution: ruclips.net/video/Ae4CDMBKRwA/видео.html

  • @alimimuhammes5258
    @alimimuhammes5258 2 года назад

    Hope not putting cooling fan wont damage the panel?

    • @KinCony
      @KinCony  2 года назад

      it can work without fan

  • @oumartellydiallo6411
    @oumartellydiallo6411 Год назад

    I would like to follow this training

  • @matthijsthijssen3406
    @matthijsthijssen3406 2 года назад

    Why you didn’t choose for a wireless solution, Zigbee based or so? Not necessary to wire your whole home to this central switch box…

    • @KinCony
      @KinCony  2 года назад

      because wired solution is best stable. we will use a new way for switch panel connection, reduce wires number.

  • @weikeungtang6722
    @weikeungtang6722 Год назад +1

    Bad to use more than 40 red short wires instead of using copper bar with plastic cover

    • @KinCony
      @KinCony  Год назад

      thanks for suggestion.

  • @user-ri8mr1on9z
    @user-ri8mr1on9z 2 года назад

    Great job

  • @dharmapatel2235
    @dharmapatel2235 11 месяцев назад

    32 channel means it can control only 32 different devices (On/Off) - correct? What if I have dimmable CCT lights? Also, how to connect this to Home Assistant that I already have?

    • @KinCony
      @KinCony  11 месяцев назад

      yes, relay controller use for control 32CH ON/OFF, if you need dimmer, you can add KC868-D16 dimmer controller into DB, so that they can work in one software.

  • @deang5622
    @deang5622 Год назад

    Those MCBs are not intended for routine switching things on and off. Typical contact life is 100,000 operations.

    • @KinCony
      @KinCony  Год назад

      yes, mainly control ON/OFF by extend wall switch panel, not by MCBs.

  • @joshuadingle2761
    @joshuadingle2761 3 года назад +2

    Hello sir! How much is the cost hardware not including the software?

    • @KinCony
      @KinCony  3 года назад +1

      you can see our online store: kincony.aliexpress.com/ all our software is free.

  • @mrhendry6552
    @mrhendry6552 2 года назад

    nice job sir

    • @BTW...
      @BTW... Год назад

      No... dangerous and non complaint to any mains wiring Standard.

  • @josephtloumello2609
    @josephtloumello2609 Год назад

    why does it not have Earth leakage that panel? how does it protect against earth fault?

    • @KinCony
      @KinCony  Год назад

      if you want ,you can add it, this is a sample demo.

  • @johnkosheluk1041
    @johnkosheluk1041 Год назад

    and when something goes bad how do you replace it with all the wires on it

    • @KinCony
      @KinCony  Год назад

      there is manual control button.

  • @muhammadsohaibkhan6224
    @muhammadsohaibkhan6224 2 года назад

    I
    love this video

  • @jasonmare33
    @jasonmare33 3 года назад

    very cool!

  • @amadoubaa4700
    @amadoubaa4700 Год назад +1

    ❤❤❤

  • @sandeepshinde4709
    @sandeepshinde4709 Год назад

    Nice

  • @vicentecamilo5636
    @vicentecamilo5636 Год назад

    Why didn't you use an electrical bus instead of cable jumpers?

    • @KinCony
      @KinCony  Год назад +1

      now updated for use bus

  • @thebestever2851
    @thebestever2851 Год назад

    What type of microcontroller are you using?

  • @sethtetteyannan
    @sethtetteyannan 2 года назад

    Please what of type of circuit breaker did you use? I see another attachment to it?

    • @KinCony
      @KinCony  2 года назад

      middle row is contact, the breaker just traditional MCB

  • @hu2481
    @hu2481 Год назад

    When you come in with AC L1 in one relais and then go 32 screw terminals to the last one, you have high connection resistance. Did you measure voltage drop under load?
    Use 4 or more feed ins and connect them in star topology.

    • @KinCony
      @KinCony  Год назад

      yes, you are right, now using 8 pins together with power in.

    • @BTW...
      @BTW... Год назад

      Poor advice from a non-electrician. Can't you see the gross design errors here?
      The only safe and professional way to do this is use a correctly rated (63A) manufactured and insulated copper busbar to connect the supply to all CB's... that then individually feed the contactors.
      A single 63A rated cable connects Main Switch to Busbar. Enclosed in a box that would be 16mm2 cable minimum. what's he using? Looks like 4mm2 solid core wire at the most... good for 32A.
      Note: No more than 2 conductors per terminal is what those CB and Contactor terminals are designed for anyway.
      Where are the Neutral and Earth bars with a minimum of 33 terminals for outgoing circuits?
      The enclosure is too small to accommodate sufficient segregation and cable management anyway.

    • @KinCony
      @KinCony  Год назад

      @@BTW... this is a demo, most use for lamp, not use full current. if large current load need thicker wire.

    • @piotrkowalkowski7349
      @piotrkowalkowski7349 Год назад

      @@KinCony doesn't metter what kind of load (lamps or anything else). Remember that CB must protect device AND CABLE - this is a principal rule. In case of some short circuits your contactors and wires are not protected, 63 A will burn out them.

    • @KinCony
      @KinCony  Год назад

      thanks for your suggestion, next project will update.

  • @jeremykromah9267
    @jeremykromah9267 Год назад

    how you did it??

  • @iqking2828
    @iqking2828 2 года назад

    With this set up it is not possible to control much load, no?

    • @KinCony
      @KinCony  2 года назад +1

      just add controller will control much load.

  • @dineshsingh-gb6un
    @dineshsingh-gb6un Год назад

    2017 ke bad lenevo thinkserver kyu nahi aaye purane hi kyu bik

  • @maxphipps2
    @maxphipps2 3 года назад +27

    Not much smart in 32 on off switches. Good to see how not to build a breaker panel though.

    • @LouieCastro3
      @LouieCastro3 3 года назад +1

      Yea those massive jumper chains look awful

    • @KinCony
      @KinCony  3 года назад +3

      now we are using new jumper, will take new video later.

    • @BTW...
      @BTW... Год назад

      Yeah, pretty dumb in many ways. I say not good to see someone with no idea on how to design and fabricate a non-compliant SCA with the intent of instructing others!
      Count the number of morons that think it's all "good work" and 'fans' who have even less idea.
      I just pity the Emergency responders that have to attend a fire or electrocution as a result of dumb ideas like this.

    • @HobbyFinn2
      @HobbyFinn2 Год назад +5

      I think it’s neat, BUT is’n all the current for every single braker going through the first screw terminal?! 32x10A……320A on a single screw terminal. Worst case. I smell MAGIC SMOKE…

    • @BTW...
      @BTW... Год назад +4

      @@HobbyFinn2 Correct regarding the string connection of supply Active to each sub circuit. EVERY dodgy looping in that panel is problematic. On that type CB the clamp is designed for little more than 32A, because that's the max rating of those CB's, when properly installed. That involves using rigid pressed copper busbar that maybe rated to carry 160-225A total loading which also directly connects to the 2 pole 63A rated Main Switch (it's not a CB... just an isolation switch). Your calculation of 32 x 10A = 320A isn't correct because this panel would be fed from an overcurent protection device (Fuse or CB) at the Main Distribution panel in the building.... but maybe not if some dodgy idiot connected it up. That fuse or CB's rating should be no more than the rating of cable to this panel AND the rating of the Main Switch. Who knows what he has used. Further, he has used small gauge low current rating solid wire for the looping and connection to Main Switch that is only good for 32A... some looping there using lower gauge wire is only rated for 10A.
      BUT LOOK closer.. that unswitched active loop feeds to every CONTACTOR (that has a even lower designed current rating) that then feeds individual CB's. This "neat" fire hazard is wired back to front!
      In any case, I first look at the Earthing/Grounding circuit, which is most important to protect life... and that fails Standards.
      Further major design flaws present.
      The Control power supply (for PLC and contactor switching operation) that is fed from Main Switch should be protected by it's own 2-10A fuse or CB. Without that the control wiring at mains potential under fault condition (which could happen inside the PLC or any relay switched contactor or low voltage power supply in that enclosure) is 'protected' at a current rating of the fuse or CB in Main Switchboard. Could be 63A... only needs to be 16A to 32A max if that thing is only controlling lighting circuits... more if general power circuits for appliances... and a lot more if controlling high demand loads like fixed heating too.
      At least he made it easy to isolate any wireless control to the panel. All you need to do is close the metal door of the Faraday Cage enclosure! LOL

  • @omegamix7750
    @omegamix7750 2 года назад

    Thanks a lot 👍

  • @eliomargoncalves
    @eliomargoncalves 2 года назад +1

    Parabéns. 1000 ok

  • @waheedkhokhar5755
    @waheedkhokhar5755 3 года назад

    You use back ground music if u stop music only you explain all connection so more help full for alls

    • @KinCony
      @KinCony  3 года назад

      thanks for your suggestion, here is a video we have maken: ruclips.net/video/B3RgOH_MGeQ/видео.html that we have explained details.

  • @sygad1
    @sygad1 Год назад

    I would enjoy a follow up video where you explained it, watching the construction doesn't tell me a lot

  • @dusax3838
    @dusax3838 Год назад

    damit sie schön dein strom abstellen könne wenn du nicht bezahlst xDD

  • @H1GH0CT8N3
    @H1GH0CT8N3 Год назад

    Our company would like to specialize in your products and methods for IOT. How can we get training?

    • @KinCony
      @KinCony  Год назад

      we have online training video play list: www.kincony.com/forum/forumdisplay.php?fid=18

  • @magayweryvan
    @magayweryvan Год назад

    Woo!

  • @mathiauskalanda9377
    @mathiauskalanda9377 Год назад

    Hello Conny...requesting for circuit diagrams and software documents

    • @KinCony
      @KinCony  Год назад

      Link in video description

  • @godfreyonyango512
    @godfreyonyango512 Год назад

    Hi can you wirig of the lighting and auto gate please

    • @godfreyonyango512
      @godfreyonyango512 Год назад

      Share wiring diagram showing the position of lighting ,dry switch and cable for auto gate.

    • @KinCony
      @KinCony  Год назад

      www.kincony.com/forum/forumdisplay.php?fid=33

  • @kofikwofie
    @kofikwofie Год назад

    please where can i get the materials to buy and diagram

    • @KinCony
      @KinCony  Год назад

      you can from our online store: kincony.aliexpress.com/store/1100463977
      all diagram download at here: www.kincony.com/forum/forumdisplay.php?fid=33

  • @Andrey0I
    @Andrey0I 9 месяцев назад

    8:55 это место 100% первым выгорит. Жаль у вас нет тепловизора)

    • @KinCony
      @KinCony  9 месяцев назад

      ruclips.net/video/Ae4CDMBKRwA/видео.html this is 2023 newest smart distribution board DIY video tour, have diagram download link in video description.

    • @Andrey0I
      @Andrey0I 9 месяцев назад

      @@KinCony ruclips.net/video/Ae4CDMBKRwA/видео.html да, тут уже все отлично.

    • @KinCony
      @KinCony  9 месяцев назад

      thanks@@Andrey0I

  • @TheTIAHUB
    @TheTIAHUB Год назад

    Sir what is the range of controlling to this panel?

    • @KinCony
      @KinCony  Год назад

      anywhere, just have internet.

  • @cristianantwi1212
    @cristianantwi1212 Год назад

    i really wanna do this as my final year project what are the names of the components u used in doing this please help me out kk

    • @KinCony
      @KinCony  Год назад

      thanks, many use our KC868-H32 series smart controller, this month have new hardware version, support alexa , google and apple homekit directly

  • @hussainnawaz9641
    @hussainnawaz9641 Год назад

    Good....we need your circuit diagram and code plxxx share it with us

    • @KinCony
      @KinCony  Год назад

      all our diagram you can see here: www.kincony.com/forum/forumdisplay.php?fid=33

  • @muzammilahmed8799
    @muzammilahmed8799 3 года назад

    Nice Work done👍👍. I need the circuit diagram and it's specificications like what kind of MCB, chips and elcbs used. Can you please give me its detail.

    • @KinCony
      @KinCony  3 года назад +1

      www.kincony.com/download/SMART-MAIN-DB-AUTOMATION.pdf

    • @BTW...
      @BTW... Год назад

      No it isn't. Don't do it.

  • @Scrapy5
    @Scrapy5 9 дней назад

    Cool but if i turn off the power my i ternet wont work so i cant turn it back on 😂😂😂😂😂😂😂😂

    • @KinCony
      @KinCony  9 дней назад

      use two different channel.

  • @aljasiyaengineering1297
    @aljasiyaengineering1297 2 года назад

    Can you upload video on Home Automation using Smart Station. Please

    • @KinCony
      @KinCony  2 года назад

      Smart Station?

  • @adilibrahim375
    @adilibrahim375 2 года назад +1

    iot is good , but no proper channel duct , no lugs , no proper main wire distribution , you may need to learn more about electrical . otherwise i see some burning smell from your this panel .. ;)

    • @KinCony
      @KinCony  2 года назад

      thanks for suggestion, the new verison many have updated.

  • @MrDenisJoshua
    @MrDenisJoshua Год назад

    Witch software are you use in the mobile phone please ?
    Thanks for the video

    • @KinCony
      @KinCony  Год назад

      now our newest controller can work with tuya app

    • @MrDenisJoshua
      @MrDenisJoshua Год назад

      @@KinCony I don't like tuya... I like all my questions in my local area.
      Is this tuya on you phone please ?
      Thanks again

    • @KinCony
      @KinCony  Год назад

      @@MrDenisJoshua ok, understand now, it can use kincony KBOX application in local network without internet.

    • @MrDenisJoshua
      @MrDenisJoshua Год назад

      @@KinCony ok Thanks a lot for the answer.

    • @KinCony
      @KinCony  Год назад

      @@MrDenisJoshua you are welcome

  • @rantungsampouw9099
    @rantungsampouw9099 Год назад

    This is Great. Thank you!

  • @Engineer1GH
    @Engineer1GH Год назад

    Hello,
    That's beautiful! I want to give it a try. Could you share circuit and software with me?

    • @KinCony
      @KinCony  Год назад

      next week, we will have new version circuit

    • @Engineer1GH
      @Engineer1GH Год назад

      @@KinCony thanks a lot; looking forward to that

    • @KinCony
      @KinCony  Год назад +1

      @@Engineer1GH ok, because we have released new smart controller, many new functions.

  • @tomaskonopac9431
    @tomaskonopac9431 Год назад

    Co takhle koupit originál propojovací lištu , když už to chcete dělat pořádně ?

  • @crisptvevents681
    @crisptvevents681 2 года назад

    wow nice project. please can it be controlled with amazon alexa?

    • @KinCony
      @KinCony  2 года назад

      yes, it can

    • @crisptvevents681
      @crisptvevents681 2 года назад

      Okay. Please is possible for you to do a video on that?

    • @KinCony
      @KinCony  2 года назад

      @@crisptvevents681 ok, later we will make it.

    • @crisptvevents681
      @crisptvevents681 2 года назад

      @@KinCony alright.. thank you

  • @wes89
    @wes89 2 года назад

    Lose the audio, speed the video up and get the thought across.

  • @janniemalan1597
    @janniemalan1597 Год назад

    May i ask the diagram and software used for this awesome project please

    • @KinCony
      @KinCony  Год назад

      you can download from kincony webpage: www.kincony.com/document

  • @joelcalaminos8259
    @joelcalaminos8259 2 года назад

    Where we can buy supplies in the Philippines? Thanks

    • @KinCony
      @KinCony  2 года назад

      you can order from our online store: kincony.aliexpress.com

  • @user-jm1bm1kd3y
    @user-jm1bm1kd3y 3 месяца назад

    Забравих Ли да спомена, че на моите звезди мимума стана "страшен"!

  • @ZhiarAOmer
    @ZhiarAOmer 3 года назад

    what is the use of terminal switch board?

    • @KinCony
      @KinCony  3 года назад

      that for manuall control with wall switch and use RF wireless remoter control 32 relays ON/OFF

  • @ehabelectrical5535
    @ehabelectrical5535 2 года назад

    Does each light need a separate circuit breaker

    • @KinCony
      @KinCony  2 года назад

      no, just traditional breaker.

    • @marek-kulczycki-8286
      @marek-kulczycki-8286 Год назад

      Why not to put breakers on the grid side, and have loads grouped, e.g. 4 light circuits per one MCB?
      It's a rare case when you can have better safety and save money at the same time. You always should have protection on the grid side, so it protects against the shorts in relays and other steering devices, not only shorts on the side of final loop (cabling and powered devices).
      With average LED power consumption of about 6.5 W you can have 350 bulbs on one B10 MCB so grouping circuits with a few MCBs makes perfect sense. Btw., B16 should not be used for standard lighting circuits (if you don't have 3000 W halogen lights).

  • @exipno
    @exipno Год назад

    Какой провод первым выгорит?

    • @KinCony
      @KinCony  Год назад +1

      this demo for lamp.

  • @bagyamadushan34
    @bagyamadushan34 3 года назад +1

    Hi..
    Do you have a distributor in sri lanka?

    • @KinCony
      @KinCony  3 года назад

      no, need send product by express

  • @mohammadshawal2213
    @mohammadshawal2213 2 года назад

    Hi sir , you can do smart air breaker DB box.

    • @KinCony
      @KinCony  2 года назад

      yes, but we not change breaker structure.

  • @WinstonFlorent
    @WinstonFlorent 3 года назад

    Do you have any controller with the Zigbee protocol?

    • @KinCony
      @KinCony  3 года назад

      we have zigbee switch panel, suggest control relay by network, it's stable

  • @al774
    @al774 Год назад

    not epileptic, but the camera jumping made it impossible to watch this

    • @KinCony
      @KinCony  Год назад

      we will improve in furture:)

  • @bamideledavid8769
    @bamideledavid8769 Год назад

    Can you please share the circuit diagram?

    • @KinCony
      @KinCony  Год назад

      circuit diagram in the video description

  • @benoitpesesse9773
    @benoitpesesse9773 2 года назад

    Connecting red and blue cables together !?

    • @KinCony
      @KinCony  2 года назад

      what time showed?

    • @benoitpesesse9773
      @benoitpesesse9773 2 года назад

      @@KinCony 8:56

    • @KinCony
      @KinCony  2 года назад

      @@benoitpesesse9773 i see, that is "N" line. maybe the AC contactor teminal use blue is better.

  • @sur0x
    @sur0x 2 года назад

    Can I use normal wall switch instead of pulse with 12v switches?

    • @KinCony
      @KinCony  2 года назад

      no problem, any dry contact wall switch can be used, just momentary switch, not must kincony's wall switch.

    • @sur0x
      @sur0x 2 года назад

      @@KinCony so just toggle switches won't work right?(like on and off), just to confirm, if its a momentary switch with dry contact will work

    • @KinCony
      @KinCony  2 года назад +1

      @@sur0x yes, not use Latch switch, use self-reset type switch button

    • @sur0x
      @sur0x 2 года назад

      @@KinCony perfect!!

  • @hammadjathar6558
    @hammadjathar6558 Год назад

    hello i hope you are fine
    Can you send me complete code and circut diagram

    • @KinCony
      @KinCony  Год назад

      ruclips.net/video/Ae4CDMBKRwA/видео.html this is 2023 newest smart distribution board DIY video tour, have diagram download link in video description

  • @shahzoddehqonov4935
    @shahzoddehqonov4935 Год назад +1

    Zuda zoʻr

  • @paholovillagran1527
    @paholovillagran1527 Год назад

    Muy bueno