    awesome video! i have a vista 32FB

  • @ghaithjaradat3037
    @ghaithjaradat3037 6 месяцев назад

    can you guide me how to where to connect the vista to the network like where should I connect the phone line and the ethernet cable ( I have the same one vista 32fb)

  • @jzzhang726
    @jzzhang726 7 месяцев назад

    Hi fire tech! Is there a way for me to wire a 24/7 audible into my panel without it saying fault 02? It’s driving me crazy thanks

  • @Will-c2l
    @Will-c2l 8 месяцев назад

    Awesome video!! Looks really nice 👍. Do you have any videos on how to power cycle a fire alarm panel? If not, could you do a video on it?

    • @FireTech7
      @FireTech7  8 месяцев назад +1

      Power cycling is when you disconnect all the power sources, wait like a minute, and then power it back up again

    • @Will-c2l
      @Will-c2l 8 месяцев назад

      @@FireTech7 Thank you.

  • @Crashtestboy2000
    @Crashtestboy2000 8 месяцев назад

    Nice

  • @jzzhang726
    @jzzhang726 8 месяцев назад

    On the vista 20p I accidentally put the power 1 and 2 on 3 by accident. Will my panel break?

    • @FireTech7
      @FireTech7  8 месяцев назад

      Test it with 1 and 2

    • @jzzhang726
      @jzzhang726 8 месяцев назад

      @@FireTech7 ok thanks

  • @patcarbone1753
    @patcarbone1753 8 месяцев назад

    Awesome

  • @jzzhang726
    @jzzhang726 7 месяцев назад

    Hi again sorry if I ask so much questions, in the vista 20p how can I wire it so the strobes don’t flash in code 3? Is that in programming? Also what resistors should I use in the NAC and zones? Thanks

    • @FireTech7
      @FireTech7  7 месяцев назад

      I'm not sure if you can set the nac to continuous in fire mode. Resistors are 2.1-2.2k, you don't need a resistor for the nac unless the jumper for Bell supervision has been cut

    • @jzzhang726
      @jzzhang726 7 месяцев назад

      @@FireTech7 okay tysm!

    • @alexandersalarms5380
      @alexandersalarms5380 Месяц назад

      @@jzzhang726 you need to buy a relay module and wire your strobes to it then program it to be a continuous output on 24 hr fire zones

    • @jzzhang726
      @jzzhang726 Месяц назад

      @@alexandersalarms5380 alright thanks !

  • @a6cct
    @a6cct 5 месяцев назад

    Is it possible to have the keypad siren or piezo (built in) to turn off, i have a 6160 keypad

    • @FireTech7
      @FireTech7  5 месяцев назад

      You can disconnect it if that's what you're asking

    • @a6cct
      @a6cct 5 месяцев назад

      @@FireTech7 how?

    • @FireTech7
      @FireTech7  5 месяцев назад

      The speaker plugs into the board and can be disconnected

    • @a6cct
      @a6cct 5 месяцев назад

      @@FireTech7 so you don’t have to permanently cut anything?

    • @FireTech7
      @FireTech7  5 месяцев назад

      @@a6cct no sir

  • @jzzhang726
    @jzzhang726 7 месяцев назад

    will my vista 20p call the police if I don’t have monitoring or a phone line? thanks

    • @FireTech7
      @FireTech7  7 месяцев назад

      No, it has to be programmed and be connected to some sort of communications line. Even then, you'll still need to program it. The vista by itself can't call the police anyway, it has to be programmed to dial into a central station and from there the central station will dispatch fire, police, medical etc

    • @jzzhang726
      @jzzhang726 7 месяцев назад

      @@FireTech7 okay thanks so I can press the panic button all I want?

    • @FireTech7
      @FireTech7  7 месяцев назад

      Yes, as long as it's not connected to any sort of monitoring

    • @jzzhang726
      @jzzhang726 7 месяцев назад

      @@FireTech7 okay tysm happy new year

  • @jzzhang726
    @jzzhang726 8 месяцев назад

    On the vista 20p what terminals do you wire the horn strobe? Where do you wire the pull station? Can anyone give me some info on how to wire this ( I know it’s not code complaint)

    • @FireTech7
      @FireTech7  8 месяцев назад

      Terminals 3 and 4 is the nac. 3 is positive and 4 is negative. A pull station would go on zone 1 and needs to be configured for fire

    • @jzzhang726
      @jzzhang726 8 месяцев назад +1

      @@FireTech7 TYSM!