Sir g ma be reparing ka kam kartha hu hu sir g 75n75 ma be khad lage hi bhot acha result deta hi ma khud be lod dal ke cheak kia hi sir g ap mosfit ko tester par cheak kare ap khud he pta calh jaye ga
China ke ups me kabhi Aapne lage hue dekhe he to hamain bhi batain 75n75 dasti ups me lagte he China me nhi lagte Agar apne kahi dekhe he to hamain bhi dekhao
Dear . IRF3205 is not equivalent to NCEP85T16. It has different parameters. For example NCEP85T16. Is 85v 160 amp IRF3205. Is 55v 110 amp Dont use 3205 in replacement of NCEP85T16.
i mere pass ek UPS aaya hai usmein yah hai ki jaise hi battery per usko on karte hain jaise beep mukamal hoti he Sath hi tak Karke relay ki awaaz aakar band ho jata
Mr.Akram it's very nice to see you command on Electronic
Many many thanks 🌹🌹🌹🌹🌹🌹🌹🌹🌹🌹♥️♥️♥️
Sultan ❤❤❤❤❤❤
Thanks for watching 🌹❤️💕
Great job
Thanks 🌹🌹🌹🌹🌹🌹
السلام و علیکم اکرم بھائی بالکل یہی فالٹ میرے ورٹکس 1214SCC میں آیا ھے ہلفی سی سکرین آنے کے بعد بند ہو جاتی ھے کیا کروں
Barakallah ustad.thank you
Thanks for watching 🌹🌹🌹♥️
Mashalla zbrdast good
Many many thanks 🌹🌹🌹🌹🌹🌹🌹
Good job 👍
Thanks Thanks Thanks Thanks 👍
Sir g ma be reparing ka kam kartha hu hu sir g 75n75 ma be khad lage hi bhot acha result deta hi ma khud be lod dal ke cheak kia hi sir g ap mosfit ko tester par cheak kare ap khud he pta calh jaye ga
China ke ups me kabhi Aapne lage hue dekhe he to hamain bhi batain
75n75 dasti ups me lagte he
China me nhi lagte
Agar apne kahi dekhe he to hamain bhi dekhao
vertex Series main 1214
NCEP85T16 K jagah konsa mospet use kare and ic kunsa use kare jo easily market se mil jaye
Mosfet 3205 or 1407
IC 3525
Dear .
IRF3205 is not equivalent to NCEP85T16. It has different parameters. For example
NCEP85T16. Is 85v 160 amp
IRF3205. Is 55v 110 amp
Dont use 3205 in replacement of NCEP85T16.
Good informition
Many many thanks 🌹
salaam sir G ❤
Thanks for watching 🌹♥️♥️♥️♥️♥️♥️
Good
Thanks
Nice Work ! Sir Ic ka Number ?
Thanks
Ok Sir
Fault 03 error ka hul kia hai akram bhai?
Bhai jaan bahut si video RUclips per padi hui hai aap vah dekhen aapko HAL mil jaega
i mere pass ek UPS aaya hai usmein yah hai ki jaise hi battery per usko on karte hain jaise beep mukamal hoti he Sath hi tak Karke relay ki awaaz aakar band ho jata
Aap ismein output ke MOSFET check Karen vah kharab honge
AP ka no mil Sakta h
03088639101 only on WhatsApp number
Great job
thanks a lot