New EVR installed today and pre-start confirmed 'no voltage on the Field terminal in Key Off condition. After start, 5.6vdc. Charge light out on dash. Hurray!!
Update: The Ford troubleshooting manual says that there should not be 12vdc on the field terminal of the EVR when the truck is not running and the key is Off. Book says EVR is shorted inside. New one coming. Will let you know.
New EVR installed today and pre-start confirmed 'no voltage on the Field terminal in Key Off condition. After start, 5.6vdc. Charge light out on dash. Hurray!!
Update: The Ford troubleshooting manual says that there should not be 12vdc on the field terminal of the EVR when the truck is not running and the key is Off. Book says EVR is shorted inside. New one coming. Will let you know.