  • Fire alarm test 59
    Hope you guys enjoy!!! This is part one of a 2 part series of tests at a retirement home in my area. This building is the largest of the two with 4 floors and a massive Siemens MXL fire alarm system installed. You also get to see some elevator recall testing.
    Join the discord: / discord
    Need a fire alarm coder or sync module? Check out my ebay store: www.ebay.com/u...

Комментарии • 58

  • @FourtyFiftyEighty
    @FourtyFiftyEighty  5 месяцев назад +8

    Idk why the intro animation is slightly delayed from the audio. Hopefully its not too noticeable

    • @josephfrye7342
      @josephfrye7342 5 месяцев назад +3

      ugh these damn siemens panel are nuttin but trouble and shit why do they have issues?

    • @STR2K6
      @STR2K6 5 месяцев назад +3

      u put the outro in 2 times

    • @josephfrye7342
      @josephfrye7342 5 месяцев назад +2

      @@STR2K6 well it happens but what about the siemens faraday panel which it is having problems?

  • @a.r.aproductions1569
    @a.r.aproductions1569 5 месяцев назад +23

    Bro was touching all that Siemen

  • @tristanajohnson6925
    @tristanajohnson6925 5 месяцев назад +3

    Gotta love those pull stations which take awhile to reset.

  • @HJCF0520
    @HJCF0520 5 месяцев назад +2

    Ah this reminds me of a retirement facility I used to inspect when I was a tech. This place was OLD. It had a Cerberus Pyrotronics PXL in one section of the building and a giant Silent Knight voice evac system in the “tower” section of the building. The building’s history goes back so far and there’s a lot of unused rooms which give it an abandoned building feel. Was always so fun to inspect it and the elevator shafts were awesome. Great video! Well done for documenting while doing the inspection!

  • @YourLocalFireAlarmTech
    @YourLocalFireAlarmTech 5 месяцев назад +2

    Siemens!! One of my favorite brands. I miss the Faraday Siemens / Cerberus Pyrotronics era of Siemens. Love the MXL systems, just hate how proprietary Siemens is. Makes it hard for collectors and enthusiasts to use them if we ain't techs for them lol.

  • @DCC--vq1ng
    @DCC--vq1ng 5 месяцев назад +4

    Compressed air should help with preventing smoke detectors to re alarm.

  • @johndeerefan725
    @johndeerefan725 3 месяца назад +1

    Siemens U-MHU-MCS in a retirement facility, I believe it was a very loud system since the U-MHU-MCS can literally blow your ears out.

  • @Loganetics1
    @Loganetics1 5 месяцев назад +4

    That one at the start seemed high pitched, interesting!

    • @tkproductions2019
      @tkproductions2019 5 месяцев назад +2

      it was likely a UMHU that replaced a former UMMT

    • @Organham4903
      @Organham4903 5 месяцев назад

      They all seem to be umhus

  • @gamingwithwilliamyt1341
    @gamingwithwilliamyt1341 5 месяцев назад +1

    great video really seeing these tests plus i've been looking for someone testing a Siemens MXL and i finally found one

  • @prism_2903
    @prism_2903 5 месяцев назад +3

    Those strobes look bright. I'm assuming 75 or 110 candela.

  • @LoyalmoonieProductions
    @LoyalmoonieProductions 5 месяцев назад +2

    Wait for 10:15 to hear the U-MHUs.

  • @BigMitch
    @BigMitch 5 месяцев назад +3

    Oh shit, is that a white UMMT? That's so rare

  • @SomeGuyWithInternet
    @SomeGuyWithInternet 5 месяцев назад +1

    One comment and a couple questions:
    1. I've seen T-handled hex keys (in fact, my dad has a few) which might be easier to reset these pull stations with! Probably would be easier to one-hand, too.
    2. 8:37 Are the UMMT and UMHU-series alarms rated for ceiling use? I seem to recall that the SpectrAlert Advance could do that, maybe these can too. I haven't seen any ceiling mount Faraday/Siemens N/As so it may not be far-fetched that they designed the same device to work on both walls and ceilings.
    3. Most prominently around 11:15 I hear a sync issue. Are these sections on different NAC's? I'm wondering if the Siemens sync protocol doesn't work between NAC's because I heard this same problem at one of my schools, despite the panel there being an XLS and the two NACs in question being entirely Siemens-rebranded Wheelock equipment (other with mechanical horns were presumably covered under different NACs). You'd hear two areas syncing internally, but one area was sounding at different times than the other.

  • @patrickstahl2006
    @patrickstahl2006 4 месяца назад

    You can make alarm horns in a Function Generator app. I replicated the SpectrAlert Advance, L-Series and the Wheelock NS, ZNS, HSR and horns alike.

  • @davidbian2466
    @davidbian2466 4 месяца назад

    Should all fire alarms be at 120db at 80 ft or is that not necessary?

  • @GaryBeltz
    @GaryBeltz 5 месяцев назад

    What was plugged in below the pull station by the panel when you started the audible test?

  • @officialsimplexguy
    @officialsimplexguy 5 месяцев назад +2

    Mark’s retirement home

  • @sarahspindler2914
    @sarahspindler2914 5 месяцев назад

    My elementary school had these fire alarms

  • @FireAlarm33
    @FireAlarm33 4 месяца назад

    I like Siemens Systems.

  • @the_1drummajor
    @the_1drummajor 5 месяцев назад

    how terrible are the mxl panels?

  • @RossiZockt
    @RossiZockt 4 месяца назад

    The pull stations are really inconvenient for maintenance purposes. 😅

  • @ZacharyHappy366
    @ZacharyHappy366 5 месяцев назад

    Why the hell is the panel date on march if the video was posted on April?

    • @FourtyFiftyEighty
      @FourtyFiftyEighty  5 месяцев назад

      There’s this crazy concept of recording a video then waiting a bit to upload it. I know its mind blowing

    • @ZacharyHappy366
      @ZacharyHappy366 5 месяцев назад

      @@FourtyFiftyEighty yep

  • @felix_the_computer_cat
    @felix_the_computer_cat 5 месяцев назад

    we have those alarms that are school

  • @cherryhuang2626
    @cherryhuang2626 5 месяцев назад +1

    Is this a that you? 10:11

  • @aerhardt
    @aerhardt 5 месяцев назад

    8:30 Why are there two annunciators?

    • @FourtyFiftyEighty
      @FourtyFiftyEighty  5 месяцев назад +1

      actually there's 3 annunciators. Its a big building

    • @aerhardt
      @aerhardt 5 месяцев назад

      @@FourtyFiftyEightyI was actually asking why there are two right on top of each other.
      Also, what happened to the horn strobes around 13:04?

    • @FourtyFiftyEighty
      @FourtyFiftyEighty  5 месяцев назад +1

      @@aerhardt ooooh one is for the second building. Test for that will be uploaded next week or so

    • @aerhardt
      @aerhardt 5 месяцев назад

      @@FourtyFiftyEightyI see. I’m excited!

  • @aidanthetoiletelevatorfire7554
    @aidanthetoiletelevatorfire7554 5 месяцев назад

    Those horn strobes seem unsynchronized.

    • @GaryBeltz
      @GaryBeltz 5 месяцев назад

      And also not the right type of NAs for a retirement community should have gone with LF horn strobes.

    • @a.r.aproductions1569
      @a.r.aproductions1569 5 месяцев назад +4

      @@GaryBeltzthe system is 30 years old. Low frequency was not available at the time.

  • @vintagesimplexfirealarmsof6440
    @vintagesimplexfirealarmsof6440 5 месяцев назад

    why was it doing 4002 t3 at end

  • @angry_pineapple6006
    @angry_pineapple6006 5 месяцев назад

    10:12 who's that guy

  • @STR2K6
    @STR2K6 5 месяцев назад

    siemen