Pawan bhai ki jai ho . very nice video . bhai ek sawal tha input our output me jo black colour ki core lagi he oh kisliye lagai he . uska kya kam hota he . reguler inverter me kyo nahi lagate he ??. sirf ups mehi dikhte he . ?? please bataye . ok thanks . by by .
Pawan bhai thanks for ups invertor repair video many people help for this. I have one question that I have genus 800va invertor many time trip ups mode and show over load but some time working fine. Pls suggest me
Singh sahab plzz check load when it shows overload If load is ok than you can check electrolytic capacitors 6800mfd/25volt for single battery inverter Thanks
Good work done ✅👏👏👏 I really need your help. Pls am repairing a 10KVA ups with low battery alarm, even though the batteries are all replaced. 16 batteries in total, summing to 213v from multimeter check, but what appear on ups screen is 174v . Kindly assist me , what could be the possible cause of the fault which affecting the voltage failure sensing. Thank you 🙏
Excellent work, i have a Eaton UPS 5SC750, and i have added 65AH batteries with it but UPS on backup give me a calculated time then shutdown ( UPS thinks it self there is 7AH batteries attached can't detect 65AH batteries ), i want to bypass calculated time frame kindly give me some expert advice on that thank you
Sir mere pass numeric 36 volt battery ka online ups hai on nahi ho raha hai Maine multimeter se IGBT 3 PIN Wala check kiya toh pata laga ke wo short hai mera IGBT no hai 11N120 CND AD hai kiya replaced kar sakta hu FGA 25N120 ANTD ?sir pls help me
Sir mere pass 24 volt 30 amp ka battery charger hai ,usme FGH 35N60 OR 10 ohm 15watt ka load resistance khharab ho gya tha ,jise me Badale diya tha 35N60 ki jagah 40n60 laga diya tha ,but power on karne on par power Aur Ho Jata Hai but output mein battery Lagate Rahe 40n60 aur 15 ohm ka registration kharab ho jata hai,pls help
Hai sir we are using numeric 1000plus ups in home last 2 years is good working condition.but today We are put mixer grinder after this ups not working and long beep sound is coming what happened this ups?
Sir mere paas arrow ka 1kva 36v ups ha jisme igbt 11n120 kharaab ha igbt ki Pluse ok karne ke baad 40k120 igbt lagai par output coil bina lode ke garm ho rahi hai output capacitor bi dusara laga liya koi solution de
Sir microtek me pin no 26 par charging volt nahi aa rahe hai. 202 bhi change kar diya or 555 bhi nikal rakhi hai .fir bhi volt nahi aa rahe .kya karan hi sakta hai.
Sir mare paas be aaya hai 1kva ups NUMERIC hp max 36volt aage display chal Raha hai magar dc volt cum nekal raha hai power board per charger do connection koe be uthata ho mai charger barabar volt 40 dekhta hai problem power board mai kes part mai problem hai mare ko batana please.
I'm sure this video contains a lot of important information about how this UPS works and I really like it, but unfortunately I don't understand your language.
मेरे पास एक ऑनलाइन यूपीएस है 96 वोल्ट से ऑपरेट होता है इसमें फोल्ड यह है कि बार-बार बैकअप मोड से हट जाता है और फिर ऑन करना पड़ता है तब फिर से ऑन होता है
Hello Sir.May apka bohot bara fan sir.
And apka video se mujhe bohot help milta hay
Thangs Sir.....for helping ud
Pawan bhai ki jai ho . very nice video . bhai ek sawal tha input our output me jo black colour ki core lagi he oh kisliye lagai he . uska kya kam hota he . reguler inverter me kyo nahi lagate he ??. sirf ups mehi dikhte he . ?? please bataye . ok thanks . by by .
Sir AJ online ke bare me bhi kahi kuch sikhne ko Mila hai thanks sir aisi video banane ke liye
Explained very nicely. Too much helpful for beginners. Thanks a lot.
Nice video.Esme bdavala transformar kya Kam karta hi .q ki charge and power k breme aap ne acchha samjaya
Really a good vedio, thanks.
We want more vedio like this.
Aapki video bahut hi knowledge full hoti h sir
Thanks
Share if possible
Pawan bhai thanks for ups invertor repair video many people help for this. I have one question that I have genus 800va invertor many time trip ups mode and show over load but some time working fine. Pls suggest me
Singh sahab plzz check load when it shows overload
If load is ok than you can check electrolytic capacitors 6800mfd/25volt for single battery inverter
Thanks
Good work done ✅👏👏👏
I really need your help.
Pls am repairing a 10KVA ups with low battery alarm, even though the batteries are all replaced.
16 batteries in total, summing to 213v from multimeter check, but what appear on ups screen is 174v .
Kindly assist me , what could be the possible cause of the fault which affecting the voltage failure sensing.
Thank you 🙏
very nice and a knowledgeable video thanks
बहुत बढ़िया और ज्ञानवर्धक वीडियो । पवन जी आपका वर्कशॉप किस स्थान पर है ?
Inverter overload indicater glow What is fault Sir ?
numeric 600 ex ups kam load par 40 second ke baad khud band ho jata hai, iska kuch ilaaj hai? Please reply
You didn't tell about that big transformer. What is the use it it comes with smps charger and high frequency inverter?
Excellent work, i have a Eaton UPS 5SC750, and i have added 65AH batteries with it but UPS on backup give me a calculated time then shutdown ( UPS thinks it self there is 7AH batteries attached can't detect 65AH batteries ), i want to bypass calculated time frame kindly give me some expert advice on that thank you
Kya 38N30 ki jagah 38N60 MOSFET laga sakte hain?
Sir mere pass numeric 36 volt battery ka online ups hai on nahi ho raha hai Maine multimeter se IGBT 3 PIN Wala check kiya toh pata laga ke wo short hai mera IGBT no hai 11N120 CND AD hai kiya replaced kar sakta hu
FGA 25N120 ANTD ?sir pls help me
Nice explanation,thank u sir Ji !
Sir mere pass ip11s- wn hitachi ka 1kv he pr usme charg amp or volt ka satting nhi he charg volt 41 volt he muje volt 40 v krne he koi upaye btaye
Sir mere pass 24 volt 30 amp ka battery charger hai ,usme FGH 35N60 OR 10 ohm 15watt ka load resistance khharab ho gya tha ,jise me Badale diya tha 35N60 ki jagah 40n60 laga diya tha ,but power on karne on par power Aur Ho Jata Hai but output mein battery Lagate Rahe 40n60 aur 15 ohm ka registration kharab ho jata hai,pls help
Hai sir we are using numeric 1000plus ups in home last 2 years is good working condition.but today We are put mixer grinder after this ups not working and long beep sound is coming what happened this ups?
Hello, what's the settings of Delta 2 kva ups.. please explain!!
Mujhe yehsb sikhne ke liye Kya parhna parega engineering ya fir diploma
ITI, DIPLOMA YA B.TECH KOI BHI CHALEGA
Sir mere paas arrow ka 1kva 36v ups ha jisme igbt 11n120 kharaab ha igbt ki Pluse ok karne ke baad 40k120 igbt lagai par output coil bina lode ke garm ho rahi hai output capacitor bi dusara laga liya koi solution de
Sir , मेरे पास एक 3 kva microtek पीस आया है जो on होने के साथ ही mains mcb ट्रिप कर देता है। क्या करूँ
Good Paji 👍
Thanks
Nice vdo sir, very useful, thank you sir
Thanks
Sir we have also an online ups of luminous 72 Volt which is completely dead . And the Inverters is high frequency inverter
Fuse ok h bt no display
Jab charging saksham ka fuse chala jata hai supply dene ke bad tab kya
Ustaz mohtaram ap agr is invetor par ziayada tawajo dogi bohot acha ho ga
I have the same ups, but yeah, bettary ko fill charge nahi karta or backup v 10 minutes se jayda nahi deta, keya kare??
Sir microtek me pin no 26 par charging volt nahi aa rahe hai. 202 bhi change kar diya or 555 bhi nikal rakhi hai .fir bhi volt nahi aa rahe .kya karan hi sakta hai.
Hello Sir. I need to use it with 12v instead of 36v. Can you please show how to do it. Thanks
Sir,G.M. hi freq. on line ups ke spears kaha mil sakate hai? mere pass bhahut sara kam in ups ka ata hai but spears ki problem aati hai
pl.reply me
Sir Eaton dx 6kva on line 16 battery error 007 Regan Kya hai battery mod per
Dear Pavan Pratap
I have 2kv 72v numerics online ups is dead could you please help in repairing it, support in getting it fixed
Sir mare paas be aaya hai 1kva ups NUMERIC hp max 36volt aage display chal Raha hai magar dc volt cum nekal raha hai power board per charger do connection koe be uthata ho mai charger barabar volt 40 dekhta hai problem power board mai kes part mai problem hai mare ko batana please.
Halo sir mara ek emerson 1kv/800watt.36bdc online ups ON out put supply plz iska koye upai bataye sir ji
Sar ji ups me transformation nhey hota to vo voltage keseh bnata hey
You are the great sir
Good tiching karte hai 👍👌👌👌👌👌👌👍👍👍👍👍👍👍
Thank U Sir ji for this post 🙏🙏🙏
Always welcome
Coast of power ckt ?isit available inmkt
Sir very nice vedio
Badavala transfomar out k Lia hi kya .online ups me kdhi Dekha nhi
🙏👌very nice teaching sir 👌🙏
Hamara numeric digital 600 ax ups on karne ke turant bad off ho ja raha hai kya kare?
Sir is ups Mai battery full charge hoti Hain lekin LCD pe battery low dekhata hai please help
240 v dc 5kw fault hai numeric ups only bypass working no display what is solution prosses
Very good 👍🙏 thank you sir
Sir discharge krne ka sahi tarika keya batiye plz.....
Thanks...sirji
sir emerson ups main fault 11 a raha hai to repair kase kare
Numeric 3 kva me 6 no. Fault kya hota h
V nice Sir 👌👍
सर् चार्ज़िंग वोल्टेज अप ओर डाउन कैसे करे
Sir bypass on hota hai but battery pe on nahi ho raha hai
Nice video 👍👍👍
इस UPS में वार्निग 10 आने का क्या कारण है ?
Sir, pls make a video for programming ic 30f2010 sinewave inverter.
u r from?
Best video as ir
Thanks
2 kav 24v ka utl Gamma PCU h sir vo ledi to Cho krta h Lekin on nahi hota sir kaa problem h
सर numric hp 2000 3 kva 96 volt me 6 नंबर falut दे रहा है
Good
Sir consul ka ups h 3kva / 96 volt DC ka sir ye 125 volt bc nikal rha h sir is ka charger card kharab hai ya sahi plz sir confirm kar do
Kam kro usko
Thanks sir ji
Sir luminous eco volt PCB repair ka video banaaooo
Good job
Transformerless inverter ke bare mein video banaen
Sir igbt based stabilizer's k bare me kuch bataye sir
we are waiting for pic16f72 tutorial.
Useful video
do you service APC online UPS ?
Hey. I got engineer who is into repairing all sort of ups, even industrial ups..
My details are in my RUclips Channel, get in touch with me
How to connect to bulb trublshoot
Ye ups me bada transfermar q laga hi
I'm sure this video contains a lot of important information about how this UPS works and I really like it, but unfortunately I don't understand your language.
Sir you dont reply to emails?
sir mere e baik ke chargiar riper karvane hai kase bheje
Thanks for sir information k liye
मेरे पास एक ऑनलाइन यूपीएस है 96 वोल्ट से ऑपरेट होता है इसमें फोल्ड यह है कि बार-बार बैकअप मोड से हट जाता है और फिर ऑन करना पड़ता है तब फिर से ऑन होता है
online 3kv UPS ma 06 error a raha hy ??
Model name
Thanks you sir gerat
👍👌👍👌👍
Sir is card ka full dittels class ka video bnaye
Sir Training dete hai please tell me
Thanks.
350 volt Dc Ac me 250 se kam hota hai
Set microteck online Kabhi video banaen
Sir kya aap online ripeyer ki training dete ho..
7981636836 if u need any help
Nice
Thank you sir
Out put voltage nahin a raha
Sir pic 16 f 72 ka agla tuturiyal banayen pls pls sir
Nice sir
Sir derive ic.chiak karna k leya jik banado sir
Ok
Sir vertiv liebert Mt+ ka bataiye
Sir TL494 PWM IC ka pora detail ka video baniya sir
kis liye ? TL494 sg3525 almost same behavior .
Thanks sir
thank u sir