Plumber - Topping up an expansion vessel - Baxi - Main - Potterton

Поделиться
HTML-код
  • Опубликовано: 14 дек 2024

Комментарии • 137

  • @raylouis6231
    @raylouis6231 Год назад

    Thanks Allen 🙂 another great informative Video. I managed to drain down my Ideal I -mini 30
    And repressurised the vessel . Heating now running perfectly . 👍

  • @benfrost8697
    @benfrost8697 5 лет назад +8

    Hi Alan , just to let you know mate, foot pumps are for feet and hand pumps are for hands ok. keep up the excellent stuff. much love

    • @AllenHart999
      @AllenHart999  5 лет назад

      Thank you. 👍

    • @robjenkins9450
      @robjenkins9450 Год назад +3

      The pump being used here is actually a stirrup pump, to be operated by both hands and feet.

  • @zdravkosim
    @zdravkosim 7 месяцев назад

    i've been searching for this info for so long. Thanks for this video !

  • @nickcarter9686
    @nickcarter9686 2 года назад

    Fantastic, I reckon you have just saved me at least £100, probably more! My boiler is running great now..

  • @sixiemetrompette7689
    @sixiemetrompette7689 4 года назад +1

    Thanks Allan this video has saved me £300. I had the same problem after following the video now my boiler works perfectly.
    Well done Allan

    • @AllenHart999
      @AllenHart999  3 года назад +2

      Please make sure you have the boiler serviced and tested correctly. Thanks.

  • @peterdalton8101
    @peterdalton8101 4 года назад +14

    Great help, thanks! But it looks like they missed an easy option there, they could have moved the red thing up a bit and had a removeable bung in the top so people didn't have to strip down the boiler to access the valve.

    • @AllenHart999
      @AllenHart999  3 года назад +2

      This job isn’t for DIY, It is something that I would advise on a boiler service. Thanks.

    • @SR-cz5yy
      @SR-cz5yy 3 года назад

      @@AllenHart999 how much would it cost to replace this including labour

    • @normanaubrey8485
      @normanaubrey8485 2 года назад

      Hi A. Can you repressurise vessel without draining the boiler?
      Thanks.

  • @coopstheplumber
    @coopstheplumber 5 лет назад +2

    Another good video Allen, Baxi Duo-Tec, great boiler, very easy to work on and bomb proof in my opinion

    • @AllenHart999
      @AllenHart999  5 лет назад +2

      I love them tbh. Thanks

    • @dazdavison1
      @dazdavison1 5 лет назад +2

      Only problem is they dont supply f2 250v fast blow fuses so try finding one of them at 4pm if it blows, why not just fit a couple spares to pcb case

    • @jamboSAFC
      @jamboSAFC 5 лет назад +2

      @@dazdavison1 or carry some on van stock

  • @sheriefgerges7789
    @sheriefgerges7789 4 года назад +1

    hi Alan I would like to make sure about the steps to top up expansion vessel as u mention in one comment one end has to to be opened. i have Worcester which filling loop built in .
    1.switch off boiler
    2. drain system
    3. close drain valve and isolate flow and return
    4. put the filling loop in open position
    5.top up expansion vessel
    6. add inhibitor
    7. pressurise the system
    Thank you

    • @AllenHart999
      @AllenHart999  3 года назад +1

      Sounds good, don’t forget to open valves at the end though. Thanks.

  • @firsteerr
    @firsteerr 5 лет назад +6

    hi Allen in the commercial world we use nitrogen to top up vessels because normal air can reduce the life of the bladder

  • @phillilley9210
    @phillilley9210 3 года назад

    Nice one Allen ,saved me a few quid.happy days ; )

  • @gazza1136
    @gazza1136 4 года назад +3

    Hi Allen just got to point out mate that theres alot of diy people watching this and will attempt the vessel recharge to save money and because its easy. Please please please people, 1st isolate the elecricity supply to the boiler. 2nd be sure you know exactly what your doing. 3rd remember its an offence if you are not gas safe registered to remove the cover off any boiler. Safety 1st👍

    • @The_best_youtuber_by_far
      @The_best_youtuber_by_far 4 года назад +1

      Hi, it’s not actually an offence to remove the cover of the boiler in your own property if you are a homeowner. You are however liable if anything happens though and you are not gas safe.

  • @yahiacherifi445
    @yahiacherifi445 4 года назад +1

    Hi Alan I wonder if I an eliminate the expansion vessel on potterton lynx 2 boiler and put an external expansion vessel as it us hard to get to it I appreciate your comments thanks

  • @russellfreestone8580
    @russellfreestone8580 2 года назад

    Brilliant. Had a kinked hose to start with, but pressure still going up will try this next

  • @Angels_reefing
    @Angels_reefing 4 года назад +3

    Can you not just leave the extension hose for the foot pump in place? So it will make it a lot easier for the next service?

  • @allum007
    @allum007 3 года назад +1

    Found out after years of removing the ignition box .That the rain drain plate can be pulled down and to the right and still get your hand in to access the vessel.

  • @elle6410
    @elle6410 26 дней назад

    If the expansion vessel has been pumped up but the problem persists, does that mean a new boiler is needed?

  • @sheriefgerges7789
    @sheriefgerges7789 4 года назад +2

    great video I would like to ask after I drain the system during topping up the expansion vessel the drain valve remain open then close it once I top up.
    Thank you

  • @H3YdUD3
    @H3YdUD3 3 месяца назад

    Can I do this myself or do I need a gas safe engineer

  • @thevenerablekev1
    @thevenerablekev1 6 месяцев назад

    I’m confused why the pressure on your foot pump was 1 bar, but at the same time the boiler pressure was zero. Can you explain? Ta.

  • @0701KRKR0409
    @0701KRKR0409 3 года назад +2

    Hello Allen
    I am new gas gas safe engineer and learnt a lot from videos from you and other senior engineers. Just like to ask you where to get this extension hose as I can’t find it any where, also can we use car tyre inflator to re pressure expansion vessel?

    • @AllenHart999
      @AllenHart999  3 года назад +1

      Sorry i didn’t see the message, I got mine from a Baxi training day but you can buy them from halfords. Thanks.

  • @craigooonw
    @craigooonw 5 лет назад +2

    Hi Allan I have a mains eco 30, serviced every year (don't no if the fella is doing it properly) but the boiler is just 3 years old. The pressure of the hot water drops regularly and the pressure gauge on the boiler shoots to 2.5/3 bar from just over the 1 bar status. You think this could be the issue??

    • @AllenHart999
      @AllenHart999  5 лет назад +1

      Sounds like the expansion vessel may need checking, Ask him to check it on the next service 👍

  • @Brian-nl1ok
    @Brian-nl1ok Год назад

    Hey pal, I’m here in the States. You should do a video on changing that expansion device. What’s involved in changing that existing expansion tank?. I hear it’s so involved that many guys just put an expansion device outside of the unit. What’s your experience?

  • @ricknotnorris
    @ricknotnorris 2 года назад

    hi allen can you help me please i have a ferrloi plues 38c boiler have repressured expansion vessel to 1 bar checked after 5min
    still 1bar good. but when boiler heats up it ruses to 3 bar \what can i do thanks rick

  • @aryansx
    @aryansx 2 года назад

    Hi Allen if expansion vessel fails dose boiler make vibrating noise as well. When heating on. If u turn hot tap on its stop vibrating

  • @carguillo1
    @carguillo1 5 лет назад +1

    cant wait for next vid al all the best mate /kev

  • @kingsuggs
    @kingsuggs 2 года назад

    Hi Allen . I've got a duo tec 24 he boiler and I've been following this video . Where do you connect the drain pipe to as my boiler doesn't have that unit on the right ? Basically I'm looking for the drain valve .Thanks

  • @wambam199
    @wambam199 3 года назад +1

    My expansion vessel is leaking...I have one to replace it but was wondering if it’s an easy job to replace the expansion vessel?

    • @AllenHart999
      @AllenHart999  3 года назад +1

      Please don’t do it yourself. It’s inside the combustion cover. This will need checking with a FGA afterwards. Thanks.

  • @alannunes6590
    @alannunes6590 3 года назад +1

    Hi Allen, my pressure gauge dropped to zero every day so cleaned the prv and pumped up the expansion vessel as per instructions, now it's banging loudly when I take a shower . Any ideas ? Thanks in advance .

    • @AllenHart999
      @AllenHart999  3 года назад +1

      This video isn’t for DIY, I would advise you call out a Gas Engineer. Thanks.

  • @mr.a2619
    @mr.a2619 5 лет назад +1

    Hi Alan, great video. So didn't realise you could drain the boiler from the magnetic filter. Please shed some light on it. Thanks.

    • @AllenHart999
      @AllenHart999  3 года назад +1

      Not sure what you mean? Thanks.

  • @MandeepSingh-sw7re
    @MandeepSingh-sw7re 4 года назад +1

    Nicely explained Thanks

  • @phasedout6769
    @phasedout6769 5 лет назад +1

    Luke is on the big cash this summer, great vid 👍

    • @AllenHart999
      @AllenHart999  5 лет назад +1

      I just got him a new computer game, He is very happy.

    • @phasedout6769
      @phasedout6769 5 лет назад +1

      @@AllenHart999 bet he's over the moon. Good to see a young'un shadowing and picking up the trade.

  • @avtarlagha719
    @avtarlagha719 3 года назад

    Hi Allen Good Morning mate i wonder if you could please do a video for me on Worcester greenstar junior 24i taking auto air vent one sit on top back of the pump without undoing the pump or anything

  • @JesusChrist108
    @JesusChrist108 4 года назад +1

    Could you do a vid explaining how shock arresters work on cold mains and why you would use them

    • @AllenHart999
      @AllenHart999  3 года назад +1

      Yes i will try my best to set something up. Thanks.

  • @HeatingSpares
    @HeatingSpares 5 лет назад +1

    Good video Alan.

    • @AllenHart999
      @AllenHart999  5 лет назад

      diybradford / Do It Yourself Thank you.

  • @ratchriat1716
    @ratchriat1716 5 лет назад +1

    I don't understand Allen why the expansion vessel on the combi boiler situated in awkward places you should have a easy access to it enjoyed the video.

    • @AllenHart999
      @AllenHart999  5 лет назад

      Very easy to do when you know how. The new boiler is much easier

  • @martinjohns8536
    @martinjohns8536 5 лет назад +1

    Hi Allen, Can I release pressure at the PRV value with the white screw before adding air to 1 bar

    • @AllenHart999
      @AllenHart999  3 года назад +1

      Not really a good idea as they will not always reseal afterwards. Thanks.

  • @CB-cz9yg
    @CB-cz9yg 5 лет назад +2

    I need to buy one of those connection! I always have to remove these vessels to pump them up, because my regin pump connector wont fully attach due to the lack of room 😕. Thanks Allen.

    • @AllenHart999
      @AllenHart999  5 лет назад +1

      No problem

    • @AmirKhan-qx2lr
      @AmirKhan-qx2lr 5 лет назад +2

      Look on ebay for shrader value extensions. They are perfect for the job and cheap as chips

  • @davidthomas3500
    @davidthomas3500 4 года назад +1

    Hi Allen, I have a problem where the copper pipe from the automatic air bleed at the top meets the plastic housing on the main exchanger is leaking. The pipe is a bit loose and the amount of drip alters as the pipe is moved slightly. The plastic housing has a clip that you pull but I don't want to pull it just in case the leak worsens. The plastic part that the copper pipe enters is fitted to the exchanger via a handfull of screws but doesnt look commercialy available. Could you let me know what makes the seal between the copper and the plastic. Vids are great by the way. Cheers

    • @AllenHart999
      @AllenHart999  4 года назад +2

      Are you a gas engineer or plumber ? Thanks

  • @markthompson6540
    @markthompson6540 2 года назад

    Can I use a normal car tyre pump?

  • @JKyfdo
    @JKyfdo 5 лет назад +1

    Well explained Allen, good video

  • @jasongeorge4602
    @jasongeorge4602 5 лет назад +2

    As a newbie , when u top up expansion vessells , does there have to be an open end ?

    • @AllenHart999
      @AllenHart999  5 лет назад +1

      Yes, Absolutely

    • @jasongeorge4602
      @jasongeorge4602 5 лет назад +2

      Ok thanks alan , learnt loads off your videos , great stuff mate , keep it up and thanks

    • @AllenHart999
      @AllenHart999  5 лет назад

      @@jasongeorge4602 Happy to help, Please keep liking and watching.👍

    • @Billy-mf1tz
      @Billy-mf1tz 5 лет назад

      @@AllenHart999 hi Allen, can you please tell me what he means by an open end? I'm hoping to do this procedure soon,so if you coukd enlighten me that would be most helpful. Brilliant videos, all the best.

  • @roylaw7765
    @roylaw7765 5 лет назад +2

    any one else think this guy sounds like Keith lemon .keep thinking hes gonna do that daft laugh any second

    • @AllenHart999
      @AllenHart999  5 лет назад +2

      Be nice if i had his money. 😂😂😂👍

  • @WILSONI007
    @WILSONI007 4 года назад +1

    Hi Alan. My main eco 30 has started to lose pressure on a weekly basis. I noticed today that water is leaking from the blow outside.. Could this be the vessel aswell?

    • @AllenHart999
      @AllenHart999  4 года назад

      WILSONI007 when was the last time it was serviced?

    • @WILSONI007
      @WILSONI007 4 года назад +1

      @@AllenHart999 about 6 years ago 😬

    • @AllenHart999
      @AllenHart999  4 года назад

      WILSONI007 well you know what you need to do then. Get Baxi out for a service

    • @_cupofteafather
      @_cupofteafather 3 года назад +2

      Had this with my eco30. They came out and pumped it back up. Sorted. Same as this vid.

  • @dipdab530
    @dipdab530 5 лет назад +3

    You’ll miss Luke next week, time to get Mackie back behind the camera.
    But saying that, you’re giving all your knowledge away, and at this rapid rate of filming you’ll be out of stuff to show us soon.
    Anyway thumbs up from me, where did you get the long extension and the angled extension from?

    • @AllenHart999
      @AllenHart999  5 лет назад

      Loads more to come. I have about 10 videos ready to upload 😂

    • @dipdab530
      @dipdab530 5 лет назад

      Allen Hart what about the 2 different extensions you used?

    • @AllenHart999
      @AllenHart999  5 лет назад

      @@dipdab530 Makes it easier to get in. 👍

    • @loafersheffield
      @loafersheffield 5 лет назад

      That's child exploitation! Outrageous!! Seriously, I was ruthlessly exploited as a child. I'm so old that I had to pull flue liners up chimneys in bare feet and clean them at the same time. My slave driver would light a fire beneath me to make me climb faster, laughing maniacally all the while. Despite all this, I still love mi Mum.
      I've had a beer. Think I'll have summore. I'm working in Rotherham on Monday.

  • @michaelcasey2833
    @michaelcasey2833 3 года назад

    How come whrn i do this on my baxi main eco elite the pressure gauge on boiler goes up aswel as on the pump im using even tho i know the system pressure is at zero what am i doing wrong ?

    • @AllenHart999
      @AllenHart999  3 года назад

      You are doing it wrong, the boiler needs an open end, drain off open, Thanks

  • @reeceprice2882
    @reeceprice2882 5 лет назад

    Where did you buy the Schrader valve extension that doesn't allow the air to be released from the vessel?

    • @AllenHart999
      @AllenHart999  5 лет назад +1

      I think i got it on a baxi training day.

  • @paulbentley849
    @paulbentley849 Год назад

    Do switch off the boiler from mains

  • @ramraja7796
    @ramraja7796 5 лет назад

    Hi Allen, Please can you tell us how the expansion vessel on unvented Cylinder would be pressurise? and is it 1 bar also.

    • @dturner8019
      @dturner8019 4 года назад

      The expansion vessel on an unvented cylinder should be set at the same pressure as the pressure reducing valve. Normally 2.1bar

  • @chriskitchen8665
    @chriskitchen8665 2 года назад

    Hi Allen, we have a main combi eco 30 which constantly leaks from the outlet pipe (from the PRV). We have to repressurise daily. Could low pressure within the expansion vessel be the cause of this? Many thanks

    • @satpal2824
      @satpal2824 2 года назад

      Hi Chris,
      I also have the same problem, was the expansion vessel the fault?

    • @chriskitchen8665
      @chriskitchen8665 2 года назад

      @@satpal2824 yes the vessel was repressurised and we also had a gas valve leak detected by the heating engineer, which was replaced. Been OK for last 10 months.

  • @billcampion2602
    @billcampion2602 3 года назад +1

    hi allen, great vids mate, can i ask what the name of that double schrader pump hose is and where you purchased from????

    • @AllenHart999
      @AllenHart999  3 года назад +1

      no idea buddy, The video was sent in. Thanks.

  • @maxnavsa4470
    @maxnavsa4470 5 лет назад +1

    Allen do you have to drain the system first?

    • @AllenHart999
      @AllenHart999  5 лет назад +4

      You need to drain the pressure out of the boiler. I try and avoid turning off the boiler valves if possible. 👍

    • @lewishowel1902
      @lewishowel1902 3 года назад

      @@AllenHart999 hi, so I have a cheap b and q one, but same thing presumably. In morning it is normally at 0.3, and when top up water it shoots up. So if in morning I just pump the air in to 1 bar, sound OK? I can access the air in for exp vessel without taking cover etc off.

  • @stewartharrod8562
    @stewartharrod8562 4 года назад

    When you pump up the expansion vessel why does the gauge not rise to 1bar?

  • @fargogemini694
    @fargogemini694 5 лет назад

    Have you done a video on a fan change?

  • @BriaCroTex
    @BriaCroTex 5 лет назад

    Where did u buy this pump and extension hose?

    • @AllenHart999
      @AllenHart999  5 лет назад

      I just got it online. Cannot remember now.

    • @AmirKhan-qx2lr
      @AmirKhan-qx2lr 5 лет назад

      the extension is easily available on ebay, they're normally used for double wheel axels on cars/trucks. Check ebay for shrader extension and you'll find them easily

  • @chucknutbraker
    @chucknutbraker 4 года назад +1

    Alan I have a valiant eco fit pure Combi it’s 30kw in a 4 storey house with 12 radiators. The boiler was working. It stopped heating water altogether . The pressure was 2.7 I dropped it to 1.5 but still not heating. There are no fault codes. Do you have any advice? Thank you!

    • @AllenHart999
      @AllenHart999  4 года назад

      Call out a local plumber to have a look, Or you could call Vaillant. Thanks.

    • @chucknutbraker
      @chucknutbraker 4 года назад

      @@AllenHart999 Thank you Allan! Called Vailant, it turned out the auxiliary pump connection was all wrong. Left the pump off altogether in the end. Works fine now. Daniel.

  • @ryandow3954
    @ryandow3954 5 лет назад +1

    And all this time ive been squeezing my (luckily) skinny hand in to take the cap off the vessel with several bruises to show for it. Why didn't i just take off the spark gen and swivel the collector out the way 🙈🙈🙈

    • @AllenHart999
      @AllenHart999  5 лет назад +1

      Every day is a school day. 😂😂😂👍

    • @ryandow3954
      @ryandow3954 5 лет назад +1

      @@AllenHart999 You've saved my poor wee hands now, thank you! 😂😂😂

    • @AllenHart999
      @AllenHart999  5 лет назад

      @@ryandow3954 😂👍😂😂😂😂😂👍

    • @Richard-ij8ge
      @Richard-ij8ge 5 лет назад

      Same....didn't realise the collector swivels....thanks Alan

  • @msidhu84
    @msidhu84 5 лет назад

    Hi m8 my potterton titanium boiler pressure goes up when heating is on after 10 min go to 3

    • @SR-cz5yy
      @SR-cz5yy 3 года назад

      Same here 🤔

  • @NineEyeRon
    @NineEyeRon 5 лет назад +1

    Is this suitable for DIYers, I am guessing not as it opens up the inner cover.

    • @AllenHart999
      @AllenHart999  5 лет назад +1

      Not really, Nice to know though and you could ask the plumber if he did it when the boiler is serviced. Thanks.

    • @NineEyeRon
      @NineEyeRon 5 лет назад +1

      Its bloomin intimidating having it open like that. Just to get to a schrader valve... Why cant they just put an extension to outside the inner cover of the gas and leccy bits. I dont want to nudge something that I shouldn't! Great vid BTW.

  • @shafiqmustafa2777
    @shafiqmustafa2777 4 года назад +1

    I had the same problem soon as I switch the central heating on the bar went all the way into the red so I had to go outside and drain off the water to get it back down when it’s nice and cool weight drops down to 1 1/2 bar soon as you turn the central heating on it goes all the way up to maximum so I called the boiler guy round and he went and charge me £200 including materials to put a brand-new red tank in when all you needed to do was do what he’s going to videos doing.

    • @namesanmanname297
      @namesanmanname297 4 года назад

      Hi, some engineers lack the skill or the experience. It's shocking what some guys get away with.

  • @paulbentley849
    @paulbentley849 Год назад

    Not all expansion vessels are set at 1 bar

  • @ImranAli-oi4jv
    @ImranAli-oi4jv 5 лет назад

    👍👌

  • @neilglazebrook5015
    @neilglazebrook5015 11 месяцев назад

    means expansion vessel is shagged waste of time

  • @simplemind7532
    @simplemind7532 5 лет назад

    That rain water drip tray is ridiculous!

    • @AllenHart999
      @AllenHart999  5 лет назад

      Why? i like it, Stops any mess in boiler.

    • @bernarddodd9041
      @bernarddodd9041 3 года назад +2

      ​@@AllenHart999 Allan we had our Potterton Gold Combi he boiler.a friend recommended ! ! ! engineer that does it on the cheap,well we had no problems with the boiler just wanted a annual service,after he had finished he said don't use hot water for 10 minutes (thought that unusual) so did wait. Then tried it found we had no hot water boiler indicates no gas supply on going out to the meter found he had turned off gas supply anyway after topping up from 0 to 1.5 then after a day or two water pressure started to drop to 1bar on checking all radiators not leaking.Must be something else he has done so I took cover off the boiler found like a vent on top of of pump slightly undone tight that up. but still have a sight pressure drop, could it be on expansion vessel were you pressure to top it up. Will no way call him back, should I call in Gas board it do Annual service, thanks

    • @rayc1503
      @rayc1503 3 года назад

      @@bernarddodd9041 top the boiler up and isolate the far left and right valve overnight. You won't be able to use the central heating for this duration. If the next morning the pressure is exactly the same your boiler is ok. Open the valves run the heating after a while take a look at the pressure gauge it should rise no more then 2.5 bar. If it's raised anything above you have a problem with the pressure vessel. If not your radiators or pipework are leaking.

  • @tomaszkus3652
    @tomaszkus3652 2 года назад

    That coud have save me £60
    Well
    I will now next time 🤷‍♂️