I wanna share some experience. Our brother did this correctly but it's recommended to replace PVC pipe with poly because PVC will not last very long (probably 5-8 years) under direct sunlight, use flap-type check valve (spring check value will lose 15% pressure), use pipe union Use check-value (spring type) if it's installed vertically (because spring type is flexible can be installed both vertical or horizontal) or high pressure (use for water pump). Use check-value (flap type) if it's installed horizontally with low pressure (example syabas meter) because it's more durable and easy to service If use water pump, the recommended accessories are : 1. spring type check-valve 2. pressure meter 3. pressure relief valve 4. pressure control valve 5. thermal switch 6. pressure switch (usually come together with water pump) Some high value properties/industrial installation using double protection for thermal switch, pressure relief valve, pressure switch
Sy sebagai juruteknik nk punya video ni.sy nk bg 5. Bintang KT abg yg buat video ni.mmg clear Dan fhm.abg ni ajar..boleh jadi cikgu bang.sy puji abg..bgus bang ilmu xkedekut..murah rezeki abg Dan sihat buat selamanya..Amin
bagus kaedah ni saya dh guna hampir 5 tahun,cuma kekurangannya bila cek valve Tu rosak air Akan msk ke dlm tangki Dan over flow,lalu ko blur bila tukar valve pelampung tp air tanki still melimpah,Dan akhirnya ko dpt tau rupanya c.valve Tu rosak bila tgk u tube org lain bgtau kekurangan kaedah cek valve ni.
Sebaiknya guna one way valve jenis flip..jika guna jenis spring kkdang spring jem n bendasing tersangkut susah lepas..jenis flip bendasing akan mudah lepas..oneway valve jenis flip sesuai utk tangki perumahan yg kandunganya kurang dari 500 galoon..jika jenis spring air akan perlahan sebab tekanan air kurang kuat utk buka valve jenis spring..jadi akan perlahan dari asal..itu pengalaman sy membuat kerja2 pemasangan oneway valve ini..🙏 Dalam video ini kekurangan 1 lagi valve..ianya perlu dipasang pada paip utama utk elak air tangki mengalir kembali ke meter apabila air dari meter terputus bekalan..
Assalamualaikum wbt bang.sy ni sepatah haram tak tahu apa2 tentang paip,rumah saya ada masalah air slow di bilik mandi melalui tangki,jadi saya ulang berkali2 perkongsian abg ni utk saya faham,alhamdulillah petang tadi siap bang sy bua,3jam sy buat haha ,air laju ngam semua..terima kasih bnyk2 bang,semoga murah rezeki dan di permudahkan semua urusan...aamiin...
Sy lupa nk bgtau dlm video...psl tmpat sy buat ni ada frp water filter kt luar rumah slpas meter yg smmngnya air tersekat kat situ.... kebiasaannya cv sy pasang slpas meter jika rumah tiada water filter coz semua outlet akan dpt supply dr tangki jika air dr main pipe tiada termasuk sinki dapur...
Tkaseh bang ilmu yang bagi mula saya beli yang menggunakan elektrik bila saya lihat saperti ini ...tak payah mengunakan elektrik......tkaseh ilmu yang abng bagi saya akan cuba,.....🤲🤲🤲🤲🤲🤲🤲🤲
Assalamualaikum bang. Saya ada masalah bilik air dari tangki air xkuat. Rumah saya double storey. Bilik air di tingkat atas. Macam mana nak dpt perkhidmatan dari tuan utk buat kat rumah saya. Tuan sangat jujur bagi penerangan dgn jelas dari A to Z. Semuga tuan dimurahkan rezeki. Tkasih
Assalamualaikum tuan.. terima kasih share ilmu, alhamdulillah faham apa yg tuan share.. apa yg saya faham, air dalam tangki baru akan turun bila paip utama tak ada air.. ini akan brlaku air dalam tangki tak digunakan dan boleh mengakibatkan air betakung lama dan busuk..
Respet✌️✌️. Sangat² jelas penjelasan tuan. Ini baru betul nk jd RUclips. Sy like Dan subcribe. Kalau ada iklan pn sy Tak skip iklan😀. Smoga murah rezeki Dan mnjadi RUclipsr berjaya bosku✌️✌️✌️
tima kasih ....hasil pngalaman sblm2 ni....sy guna pelbagai jenis paip jgk coz nk tgk kualiti camner... sy pn try & error jgk... insyaallah apa yg ada dlm dada sy , sy akan curah kt sini....
Salam tuan, saya buat by pass, bilik utama je laju air dan bilik air no 2 pelahan....lubang tangki satu utk bilik utama dan bilik air no 2......check valve satu dari main n satu dari air tangki....
saya rasa klu bikin bypass..xperlu psng checkvalve..klu tujuan nya bypass utk dptkn pressure air lebih kuat utk support air dr tgki..ke rmh. Klu psg checkvalve air tgki xakn supply kermh...Tngki tkr peranan sbgai reservd tank. sila btlkn klu silap.!
Assalamualaikum tuan..salam dari borneo,, Alhamdulillah jelas pencerahan tuan ni,cuma ada 1 faktor yg saya x faham mengenai 1 btg paip bediri lurus dpn tangki tu utk apa ya? Spt dlm video ni,paip kluar dari tangki ada sbtg paip bdiri tinggi spt tinggi tangki trsebut,jadi minta tuan share apa kegunaan dya😊
saya tlg jwpkn.boley yek.. paip vertical tu peranan nya utk support paip yg lalu diatas..so paip tegak tu kosong..cara ni dibuat bila poisition paip jauh dr dinding utk psng hook didinding.. juga utk paip di atas &bwh kukuh & nmpk kemas.. sbb ada support stand... klu salah sorry Bahh
Kalau pressure air direct laju boleh la buat mcm ni ..kalau air dari meter pun meleleh Kena pakai water pam jgk ..sy plumber area utara...mmg byk sy pakai booster pam kalau rumah 2 tingkat,3 blk air ke atas.rumah setingkat 2 blk air pun nak pakai booster pam sbb air mmg puas hati...laju....sy sendiri pun kena pakai water pam....air slow sgt kat rumah sy...apapun perkongsian terbaik....
@@budakbaik7425 ya.... betul... jika pasang pump lepas meter, ia aniaya pada jiran jika pressure air dari luar slow. pump kena pasang lepas tangki, maksudnya sedut dari tangki.
kaedah bypass dan one way valve ni, jika air direct pressure ok dah contohnya jika setahun air direct tak tutup2, maka tangki setahun lah bertakung, tak guna
@@harzman1123 kat utara sy psg tank asing kat bawah,sbb tekanan air terlalu slow,air masuk dari ke tank baru dulu..pastu guna booster pam utk sedut air ke dlm rumah,kat tank asal sy buat bypass....tank atas tetap air akan turun jgk tuan bila kita buat bypass....kat sini sistem mcm tu ja yg terbaik....tp kos mmg tinggi la..cuma mmg terbaik la...mandi shower pun best...tp tangki flush blk air xleh pakai yg biasa..yg pakai pelampung hitam tu...sbb cepat rosak...air terlalu laju...mcm tuan ckp air kat tank akan bertakung sy xberapa jelas sbb sy buat bypass air tank pun akan guna... semalam pun sy p cek rumah custumer sy....air tank dia akan kurang bila guna bila air...boleh tahu booster pam akan jln utk topup blk ke tank atas....sekadar info dan pengalaman sy buat pemasangan water pam/booster pam....
Dah guna bypass direct water, fungsi checkvalve tu dah jd bekalan spare. Kalau bekalan direct terputus maka tekanan dari tangki akan menolak check valve utk bekalkan air
Kalau bekalan air tak terputus maksudnya air dr main sentiasa ada.. air tangki tu takkan digunakan betol ke? tp mcm mana nk bg air dlm tangki tu digunakan ya sebab kalau lama sangat dalam tangki tak bagus kan?
@@yiktakata3968 xmungkin air tangki keluar bersama air direct..sebab tekanan direct kuat berbanding tangki maka air direct akan tutup checkvalve.. cuba tgk 17:10
@@aleaf88 kalau dah pasang check valve mmg air tangki tak gerak selagi air main ada. Mcm saya saya akan buat satu lagi paip direct tangki buat ambil wuduk. So air tangki still gerak
tmkasih tuan atas perkongsian yg bagus. nk tanya, paip yg menegak ke atas pd permulaan kluar service paip dr tangki tu apa fungsi? ada sstgh x wujud pon mcm tu
@@fixfairuz1808mcm mna ye nk tahu bacaan tekanan air kt rmh kita tuan? apa alat yg perlu ada bole dikongsi x? tuan dduk dekat area mana tu? klau dekat dengan sy nk mnta tolong buatkan kt rmh sy…nanti buat kira2 brapa kos brg nk buat serta upah psg….bole tuan?
@@fixfairuz1808 bos nak tanya... boleh ke air dari tangki turun, sekiranya air dari meter tak ada, sebap chek valve tu ada spring, air dari tangki tu kan tekanan tak kuat, ?
Saya ada satu soalan. Berkenaan sistem ni saya paham 100% .sebab dr background mekanikal. Tapi persoalan saya.tuan tak pasang check valve di inlet. Jika bekalan air main supply terputus.. adakah air akan berpatah balik ke meter kemudian akan sedut habis air tangki ke rumah kejiranan yg guna..ahhahaha.. paham kan soalan saya?
Assalamualaikum tuan , t.kasih penerangan yg cukup lengkap , cuma sy nk tanya dekat paip utama dr meter x perlu letak check valve juga ke in case air dr meter utama tiada bekalan air , air dr tangki air akan pergi ke piping meter utama jika tiada check valve
Tuan pertanyaan..kegunaan air tangki 2 saluran 1 kebilik air bawah..1 lagi ke bilik atas..masalhnya air bilik atas tk selaju bilik air bawah..jika sy pasang check valve utk bilik air atas shj..ada problem ke .dri segi kebaikan atau keburukkan..
Masalah bypass ini , air di tangki ada chlorine masa fresh dari sumber Tapi bila terlalu lama tinggal di dalam tangki , chlorine tu sudah tak ada, bacteria dah kulat pula Akan datang. Masa tak ada air, tak tahu air dari tangki itu selamat atau tidak. So guna cara ini , perlu clear tangki air atau rajin Cuci air dalam tempoh beberapa hari atau minggu. Atau guna booster pump terus.
nak tanya, dari tangki tu ada dua outlet. selepas stock.cock saya nampak ada paip yang naik ke atas... yang tu pergi mana? atau atas ditutup (utk create pressure?)
Rumah saya dua tingkat. Bilik tingkat atas di bawah tangki tak ada masalah. Tingkat bawah tak ada masalah. Tingkat atas belah lain dari tangki, pressure rendah, sehingga shower tak ada air langsung. Ini masalah air lock ke pressure tangki? Saya cuba release airlock macam video RUclips macam tak berkesan, mungkin cara salah. Lebih baik pasang terus pump kat tangki atau modify tambah check valve macam ini dah cukup? Atau apa cara release air lock yang betul?
@@alakhir9020 check valve yg selepas meter tu bertujuan mengelakkan terjadinya "sucking" @ negetive pressure @ back flow ke dlm mainline bila air tiba2 slow atau lagi teruk, air putus (kalau tak sempat tutup main valve). Semua air yg ada dlm service pipe kita tu blh tersedut balik masuk ke comm. pipe & main pipe syarikat air.
Terbaik penerangan tuan, sy dh pasang cv mmg air dlm bilik air laju, cuma nak tanya bila tutup stopcock utama naik ke tangki air dlm bilik air jadi slow sangat, apa masalahnya ya tuan?
Hi fairuz. Sambungan paip di video utk brp bilik? Biasa rumah 2 tingkat ada 4 bilik mandi. 3 bilik mandi di tingkat 1 Dan 1 di tingkat bawah. Macam mana nak pasang bypass? Fairuz ada buat pemasangan di kawasan klang Bukit tinggi 2? Terima kasih.
Assalamualaikum bang… sy tgk abg ajar ni mcm sy boleh buat tp masalahnye jenis paip xsama😅… abg boleh tlg x cmne kalau paip lama main paip besi…outlet air ke toilet pvc… cmne sy nk buat bypass… umh sy paip mmg slow terus… penah pakai water heater yg ade pump pun xlarat nak pump…
Waalaikumsalam, nk tanya, rumah ada tangki x? @ ambil direct semua dari main pipe? Kalo xpakai tangki xblh buat. By the way, pvc dan paip galvanised saiznya sama shj.... blh pakai samada penyambung yg ada bunga (threat). @ lbh senang gi kedai hardware tanya brng apa perlu pakai utk material paip lain jenis...
@@fixfairuz1808ada tangki bang… cuma main paip air masuk tu jenis besi saiz rasa mcm besar dr paip outlet pvc dan bersaiz kecil sikit… ukuran saiz xbrp pasti sbb xde plak tulis kat situ…
Tak silap.Klu pressure dr main paip lebih tinggi dr tekanan tangki. Bypass flow selepas check valve xkan masuk ke laluan output. Hanya akan lalu jika press dr main paip lebih rendah dr tangki
Kalau dah pasang bypass ni,mcm mne kte nk guna air melalui tangki .. adakah kena bukak kunci?? Dan mcm mne kte nk pkai air melalui direct? Kena buka kunci jgak ke..boleh terangkn mcm mne sistem dia
pendek cerita...kedua2nya berfungsi. Tiada apa2 kunci diperlukan...stopcock yg dipasang itu cuma utk safety....jika ada paip bocor pd 1 bhgian.hanya tutup stopcock itu shj tanpa perlu tutup stopcock dkt meter air tu....jimat tenaga xperlu turun naik semasa kerja2 repai dilakukan.
Air tangki akan keluar spt biasa dan dibantu tekanan keluar bersama air direct dari meter.....kalo tanya percentage sy kurang arip cara nk kira...ttpi bergantung pd keadaan graviti smadasama byk atau salah satu akn keluar minima, satu lg kwluarkan air secara maksima...
Salam bang terima kasi ilmunya Cuma mau tanya sambungan bypass dr meter tu tak perluka pasang oneway valve sbb air dr tgki akan bepusing balik masuk ke tangki ikut laluan by pass tu sbb drumah saya mcm tu terus overflow@ rumah saya ketinggian tangki tak betul
Sepatutnya air dari tangki takan masuk balik ke paip utama bila tiada air masuk sebab paras air masuk dalam tangki adalah tinggi (bersekali dengan pelampung).
kan dia dah bypass td😅.. bukan keluar dr pelampung tu.. keluar dr outgoing la masuknke meter balik.. sebab dalam kes ni dia dah bypass incoming dan outgoing dr satu paip dan laluan yg sama.. one way valve hanya menghalang incoming masuk ke tangki melalui outgoing..tapi dia tak halang dr outgoing ke meter sebab dia tak pasang one way valve kat incoming.. tp saya ada baca komen.. air dr dalam rumah tak kan melepasi meter sebab meter tu pon sebenarnya bersipat one way direction jugak..
Salam tuan. Nak tanya. Klu sebelum kita buat kerja paip ni, tapi tangki tak diskosongkan dulu sebaliknya tutup saja valve outlet dari tangki, ada apa2 perbezaan tak? Atau mmg nak kena kosong kan jugak dulu tangki sebelum buat kerja2 paip? Mohon penjelasan tuan 🙏🏻
Seblh2nya kosongkan.... sebab kalo bocor jd 2x kerja... utk rumah sendiri ok...mcm sy jd byk kerja billa owner rumah call ada bocor....rugi masa dan kos ulangalik serta brng perli ditukar baru....xsalah blh cuba...
Encik, nak tanya sikit berkenaan dengan air dari tangki yg beri tekanan kepada main pipe/direct. Katakanlah kalau tiada air dari main pipe/meter air, bukankah air dari tangki akan mengalir masuk ke meter air? Jadi adakah patut letak satu check valve selepas meter air?
Tgk level rumah...jika tere sama level xde masalah kecuali rumah kita level tunggi dr rumah org lain....itu blh pasang 1 lg check valve slpas meter air...kalo ada pakai penapis air yg besar tu dkt dgn meter air tidak perlu check valve...
Rasanya meter air dia mcm check valve jgk kalau psg terbalik meter air tu air tak akan kelua jdi kalau tak ada air dri paip utama rasanya air tak akan mengalir ke meter
kalo dr main ke panggil Syabas @ mana konsesi negeri, mntak diorng bukak valve besar sikit....tp kalo tekanan stay rendah jgk kwsan tu terpaksa pakai pam elektrik lah
saya dah buat check valve dari tangki tak mau bukak dari pressure tangki tak kuat nk tolak valve tu kalau tutup air direct.. maknanya dia guna pipe air direct je sebenarnya.. tutup direct dari tangki tak keluar setitik pun.. jd tak ada function la air tanki.. igtkn bila buat sistem mcmni air tangki dgn air direct bertembung jadi labih kuat air.. rupanya bukan.. hmmm dia baypass jd sistem tangki stop direct je yg jalan.. kalau direct mcm air luir meleleh mmg xfunction langsung.. rasa kecewa pulak.. hmmm
Pertama tuan kena pastikan sambung dan kedudukan check valve itu betul....kedua pastikan juga tiada mana2 paip yg tersumbat @ ada halangan utk mengalir secara sempurna... ketiga baru kita check keseimbangan graviti pepasangan kita.....
Pemakaian Tanki air di perlu kn jika tekanan / kederasan ( main)sumber Air tidak mencukupi dan booster pump harus di beri pilihan jika tekanan air melalui gravity juga tidak mncukupi. Jika tekanan dari sumber air mencukupi maka tanki dan booster pump hya digunakn pada waktu2 darurat. Dari itu saluran atau piping line harus diubah sesuai dan adalh Terlebeh baek mngunakn pipe dan tanki yg terbuat dari bahan stainless Steel yg tahan lama dan tahan karat daripada mngunakn PVC pipe . Dalam isu ini Perlu diingat juga Tanki harus dirawat.
Assalam tuan. Bermakna kita menggunakan air dr paip meter lah ye. Bl paip meter xde air, baru lah air tangki digunakan. Betul ke mcm tu tuan. Saya keliru jgk tu 😄
Salam bro... saya tak faham di dua tempat ni, minit 23:06 dan 23:17 Apa fungsi paip menegak panjang ni, satu selepas stop-cork out-going dan satu lagi sebelum...??
apoo🤣 aku okay je potong poli pakai grgaji, brtahun² dh buat plumber, xde kluar pun air. jnji pasang soket tu btul, xde trbalik².. potong pun kena lurus.. 🤣🤣
Bila kita hendak menjadi guru biarlah ajar benda yg betol, selamat dan memudahkan..apa guna sesuatu alat dicipta?.apa guna compressor dicipta walhal berus cat lg murah...samalah perbandingan apa yg kamu kata gergaji pon blh....bkn setakat gergaji, dengan parang pn blh....kdng2 soal keselamatan pon kene fikir jgk...kualiti kerja pasti bagus jika kita menggunakan peraltan yg betol....itulh yg dipanggil orang 'kompetan' dlm dunia teknikal...
Blh sangat dan xperlulh pakai check valve.....tp kalo semua direct dr meter air nnti air xde semua xleh pakai tau...dan air tangki nnti dh rugi xguna.....
Nie namanya baypass tank. Air datang terus dari air paip ke bilik air. Bila air paip tak de baru, air dari tangki akan keluar. Sebenarnya tak bagus sebab air tangki disimpan terlalu lama, bakteria cepat membiak dalam air tangki. Cara terbaik air tangki harus sentiasa digunakan. Tarik paip dari tangki ke mesin basuh atau mane tempat yang sesuai. Jangan tarik ke sinki atau penapis air. Cara ini dapat mengurangkan pembentukan bekteria dalam tangki air.
blh bg 1 sbb knp air dr tangki tidak digunakan kalo ada bypass....? adakah air itu bersifat keras mcm batu? tidak blh bergerak walau sedikit? biat komen blh diterima akal
Tgk video tu biar smpai abes...kan dh xfhm...org leng ok jer fhm...semua dh bgitau kt situ.. rasa xbetul, buatlh video awk yg betol sgt tu....tgk ada org nk tgk ker x....
Pemerangan yang amat jelas..terima kasih Tuan sedia kongsi ilmu yg bermanafaat
I wanna share some experience.
Our brother did this correctly but it's recommended to replace PVC pipe with poly because PVC will not last very long (probably 5-8 years) under direct sunlight, use flap-type check valve (spring check value will lose 15% pressure), use pipe union
Use check-value (spring type) if it's installed vertically (because spring type is flexible can be installed both vertical or horizontal) or high pressure (use for water pump).
Use check-value (flap type) if it's installed horizontally with low pressure (example syabas meter) because it's more durable and easy to service
If use water pump, the recommended accessories are :
1. spring type check-valve
2. pressure meter
3. pressure relief valve
4. pressure control valve
5. thermal switch
6. pressure switch (usually come together with water pump)
Some high value properties/industrial installation using double protection for thermal switch, pressure relief valve, pressure switch
Sy sebagai juruteknik nk punya video ni.sy nk bg 5. Bintang KT abg yg buat video ni.mmg clear Dan fhm.abg ni ajar..boleh jadi cikgu bang.sy puji abg..bgus bang ilmu xkedekut..murah rezeki abg Dan sihat buat selamanya..Amin
bagus kaedah ni saya dh guna hampir 5 tahun,cuma kekurangannya bila cek valve Tu rosak air Akan msk ke dlm tangki Dan over flow,lalu ko blur bila tukar valve pelampung tp air tanki still melimpah,Dan akhirnya ko dpt tau rupanya c.valve Tu rosak bila tgk u tube org lain bgtau kekurangan kaedah cek valve ni.
Terima atas penerangan tn...
Sebaiknya guna one way valve jenis flip..jika guna jenis spring kkdang spring jem n bendasing tersangkut susah lepas..jenis flip bendasing akan mudah lepas..oneway valve jenis flip sesuai utk tangki perumahan yg kandunganya kurang dari 500 galoon..jika jenis spring air akan perlahan sebab tekanan air kurang kuat utk buka valve jenis spring..jadi akan perlahan dari asal..itu pengalaman sy membuat kerja2 pemasangan oneway valve ini..🙏
Dalam video ini kekurangan 1 lagi valve..ianya perlu dipasang pada paip utama utk elak air tangki mengalir kembali ke meter apabila air dari meter terputus bekalan..
Assalamualaikum wbt bang.sy ni sepatah haram tak tahu apa2 tentang paip,rumah saya ada masalah air slow di bilik mandi melalui tangki,jadi saya ulang berkali2 perkongsian abg ni utk saya faham,alhamdulillah petang tadi siap bang sy bua,3jam sy buat haha ,air laju ngam semua..terima kasih bnyk2 bang,semoga murah rezeki dan di permudahkan semua urusan...aamiin...
Alhamdulillah.....
@@fixfairuz1808 boleh sy dapatkan contact number tuan
010 339 2020
3 jam x per.. yg penting dpt siap sblm waktu2 kritikal...hehe
sama2 kita belajar... byk juga idea2 dlm komen2 yg diberikan...blh baca jg....guna yg mana betol...yg komen merapu tu, abaikan jer
kene ada lg 1 check valve kat bypass utk elakkan air tangki return ke meter.
elok guna swing valve, takde spring. lebih tahan lama
Betul tuan, klau xda 1lgi check valve air dari tangki keluar ke meter. Bila air xda, air dlm tangki pun habis. Itulah pengalaman umah saya
Sy lupa nk bgtau dlm video...psl tmpat sy buat ni ada frp water filter kt luar rumah slpas meter yg smmngnya air tersekat kat situ.... kebiasaannya cv sy pasang slpas meter jika rumah tiada water filter coz semua outlet akan dpt supply dr tangki jika air dr main pipe tiada termasuk sinki dapur...
Abg rumah area mana ya? Ada pernah nampak komen org kata kat meter air tu dah ada non return valve
@@mohdnasir4921
Ya betul..kekurangan 1oneway valve di paip air dari meter👍..juga baik guna oneway valve jenis flip..👍🙏
mudah cerita brader ni sambung direct dari bekalan luar, kalau air luar xmasuk air tangki ada 👍👍
Sikit tak sama. Ada non return valve, pressure lebih tinggi Dari direct sambungan
Saya paham maksud awak..dan kenyataan awak benar .
tuan explain betul2 macam cikgu..terima kasih ilmunya
Tkaseh bang ilmu yang bagi mula saya beli yang menggunakan elektrik bila saya lihat saperti ini ...tak payah mengunakan elektrik......tkaseh ilmu yang abng bagi saya akan cuba,.....🤲🤲🤲🤲🤲🤲🤲🤲
sama2...alhamdullillah....kalo masih ada part yg xfaham blh tanaya yer...
Senang kata check valve tu letak selepas stopchock outlet dari tangki tapi sebelum pipe bypass
Assalamualaikum bang. Saya ada masalah bilik air dari tangki air xkuat. Rumah saya double storey. Bilik air di tingkat atas. Macam mana nak dpt perkhidmatan dari tuan utk buat kat rumah saya. Tuan sangat jujur bagi penerangan dgn jelas dari A to Z. Semuga tuan dimurahkan rezeki. Tkasih
Assalamualaikum tuan.. terima kasih share ilmu, alhamdulillah faham apa yg tuan share.. apa yg saya faham, air dalam tangki baru akan turun bila paip utama tak ada air.. ini akan brlaku air dalam tangki tak digunakan dan boleh mengakibatkan air betakung lama dan busuk..
Penerangan abg ni sangat jelas dan mudah faham terima kasih bang
Respet✌️✌️. Sangat² jelas penjelasan tuan. Ini baru betul nk jd RUclips. Sy like Dan subcribe. Kalau ada iklan pn sy Tak skip iklan😀. Smoga murah rezeki Dan mnjadi RUclipsr berjaya bosku✌️✌️✌️
Alhamdulillah..terima kasih atas doa yg baik2....⚘️
Terbaik bosku penebangan jelas.. Ini projek terbaru saya.. Air dirumah saya slow sangat.. Terima kaseh tuan... Inshaallah harap berjaya..
Alhamdulillah...hrp ilmu yg tuan belajar ni, dpt tuan kongsikan jgk dgn jiran2 & sahabat2 yg lain.....kongsikan ilmu besar pahalanya...insyaallah...
Perkongsian yg sangat baik. Ilmu yg sangat berguna.. trima kasih
Terima kasih Tuan, boleh cuba. Selalu bila bukak 1 paip, yang lain air macam meleleh aje.
penerangan mantap gile..seronok menonton dgn dpt ilmu sekali..,,👍
mekasih tuan...
Mantap ilmu yg saudara perturunkan kerja2 sambungan paip begitu kemas sekali
tima kasih ....hasil pngalaman sblm2 ni....sy guna pelbagai jenis paip jgk coz nk tgk kualiti camner... sy pn try & error jgk... insyaallah apa yg ada dlm dada sy , sy akan curah kt sini....
Salam tuan, saya buat by pass, bilik utama je laju air dan bilik air no 2 pelahan....lubang tangki satu utk bilik utama dan bilik air no 2......check valve satu dari main n satu dari air tangki....
buka kepala paip bilik air no 2...mnhkin ada benda yg tersumbat
12:37 terima info bang, saya baru tahu spec jkr
Sy tk ada tangki..semua guna derek dari meter..air laju..tangki sper sy asing guna tong biru..dan mudah kerja2 mentenans.
saya rasa klu bikin bypass..xperlu psng checkvalve..klu tujuan nya bypass utk dptkn pressure air lebih kuat utk support air dr tgki..ke rmh. Klu psg checkvalve air tgki xakn supply kermh...Tngki tkr peranan sbgai reservd tank. sila btlkn klu silap.!
Terimakasih Abg diatas perkongsian ilmu tersebut.moga rezeki Abg diluaskan
Baguih , terang dan jelas, tp rase bill air ade increase jgk mcm nih..... Good job 👌
increase xbyk sbb tekanan smmngnya dtng jg dr paip utama....
ya bil air akan meningkat sbb guna direct dari paip utama, mesti meter jalan laju, hehehe
Assalamualaikum tuan..salam dari borneo,, Alhamdulillah jelas pencerahan tuan ni,cuma ada 1 faktor yg saya x faham mengenai 1 btg paip bediri lurus dpn tangki tu utk apa ya?
Spt dlm video ni,paip kluar dari tangki ada sbtg paip bdiri tinggi spt tinggi tangki trsebut,jadi minta tuan share apa kegunaan dya😊
saya tlg jwpkn.boley yek.. paip vertical tu peranan nya utk support paip yg lalu diatas..so paip tegak tu kosong..cara ni dibuat bila poisition paip jauh dr dinding utk psng hook didinding.. juga utk paip di atas &bwh kukuh & nmpk kemas.. sbb ada support stand... klu salah sorry Bahh
terima kasih atas perkongsian ilmu👍🏻 semoga Allah merahmati encik🤲🏻
Sama2 bro..... insyallah byk lagi perkongsian utk penjimatan penggunaa peralatan rumah...blh subcribed spy xketinggalan
Kalau pressure air direct laju boleh la buat mcm ni ..kalau air dari meter pun meleleh Kena pakai water pam jgk ..sy plumber area utara...mmg byk sy pakai booster pam kalau rumah 2 tingkat,3 blk air ke atas.rumah setingkat 2 blk air pun nak pakai booster pam sbb air mmg puas hati...laju....sy sendiri pun kena pakai water pam....air slow sgt kat rumah sy...apapun perkongsian terbaik....
blh kongsi x dgn kitorang semua brp hp diperlukan utk rumah spt diatas...? dan Pam seeloknya dipsng sblm tangki @ slpas tangki?
@@fixfairuz1808 pasang pam kena selepas tangki bang. X boleh sebelum tangki, syarikat air marah nanti
@@budakbaik7425 ya.... betul... jika pasang pump lepas meter, ia aniaya pada jiran jika pressure air dari luar slow. pump kena pasang lepas tangki, maksudnya sedut dari tangki.
kaedah bypass dan one way valve ni, jika air direct pressure ok dah contohnya jika setahun air direct tak tutup2, maka tangki setahun lah bertakung, tak guna
@@harzman1123 kat utara sy psg tank asing kat bawah,sbb tekanan air terlalu slow,air masuk dari ke tank baru dulu..pastu guna booster pam utk sedut air ke dlm rumah,kat tank asal sy buat bypass....tank atas tetap air akan turun jgk tuan bila kita buat bypass....kat sini sistem mcm tu ja yg terbaik....tp kos mmg tinggi la..cuma mmg terbaik la...mandi shower pun best...tp tangki flush blk air xleh pakai yg biasa..yg pakai pelampung hitam tu...sbb cepat rosak...air terlalu laju...mcm tuan ckp air kat tank akan bertakung sy xberapa jelas sbb sy buat bypass air tank pun akan guna... semalam pun sy p cek rumah custumer sy....air tank dia akan kurang bila guna bila air...boleh tahu booster pam akan jln utk topup blk ke tank atas....sekadar info dan pengalaman sy buat pemasangan water pam/booster pam....
Terima kasih diatas perkongsian ilmu..moga dapat balasan di dunia dan akhirat
Air kuat kerana paip air dari meter dah bypass selepas check valve,..
Dah guna bypass direct water, fungsi checkvalve tu dah jd bekalan spare. Kalau bekalan direct terputus maka tekanan dari tangki akan menolak check valve utk bekalkan air
abselutely yes....👍
Kalau bekalan air tak terputus maksudnya air dr main sentiasa ada.. air tangki tu takkan digunakan betol ke? tp mcm mana nk bg air dlm tangki tu digunakan ya sebab kalau lama sangat dalam tangki tak bagus kan?
@@aleaf88 air tangki tetap keluar bersama air direct main
@@yiktakata3968 xmungkin air tangki keluar bersama air direct..sebab tekanan direct kuat berbanding tangki maka air direct akan tutup checkvalve.. cuba tgk 17:10
@@aleaf88 kalau dah pasang check valve mmg air tangki tak gerak selagi air main ada.
Mcm saya saya akan buat satu lagi paip direct tangki buat ambil wuduk. So air tangki still gerak
mantap penjelasan
tmkasih tuan atas perkongsian yg bagus. nk tanya, paip yg menegak ke atas pd permulaan kluar service paip dr tangki tu apa fungsi? ada sstgh x wujud pon mcm tu
Itu utk 'air release'.nnti sy buat video apa kepentingan paaip ini...xde pon xper tp ada skit risiko 'air locked'.
Guna air incoming memang la kuat... Tapi sudah kurang pasang 1 check velve kat incoming...
tidak juga jika incoming slow air tetap akan slow tanpa bantuan booster pump....video inihanya utk incoming yg stabil dan tekanan melebihi 1.5 bar...
@@fixfairuz1808mcm mna ye nk tahu bacaan tekanan air kt rmh kita tuan? apa alat yg perlu ada bole dikongsi x? tuan dduk dekat area mana tu? klau dekat dengan sy nk mnta tolong buatkan kt rmh sy…nanti buat kira2 brapa kos brg nk buat serta upah psg….bole tuan?
terbaik bang. terima kasih memperkenalkan check valve
dh buat dh ? kalo ada xfhm blh tnya yer....
@@fixfairuz1808 bos nak tanya... boleh ke air dari tangki turun, sekiranya air dari meter tak ada, sebap chek valve tu ada spring, air dari tangki tu kan tekanan tak kuat, ?
Terima kasih pakcik atas perkongsian ilmu..
Saya ada satu soalan. Berkenaan sistem ni saya paham 100% .sebab dr background mekanikal. Tapi persoalan saya.tuan tak pasang check valve di inlet. Jika bekalan air main supply terputus.. adakah air akan berpatah balik ke meter kemudian akan sedut habis air tangki ke rumah kejiranan yg guna..ahhahaha.. paham kan soalan saya?
Kemah bossku.... Kemaman idaman
T.ksh atas perkongsian ilmu
sama2 tuan....hrp bermanafaat...
untuk tahan lama, saya spray clear coat spring check valve tu.
Betol...lagi esok spray sgn paip sekali utk panjangkan hayat paip dr sinaran uv atau air hujan...
Terima kasih perkongsian tuan
sama2 tuan.moga bermanafaat...
minit 3:17 dah nampak.. seluruh sistem tangki diganti hybrid tangki + air bekalan. bermakna jika bekalan air xde, air akan perlahan kembali.
Yer betol.. cara ini hanya alternatif utk kurangkan kos....
Maknanya macam dairect paip jugak la kan, andai kata paip bilik air guna dua2 serentak.....dua bilik air, ada kemungkinan tak air kecil
@@marhalimbain3635 2 paip tu akan lbh laju drp sblmnya
Terbaik
Informasi yang berguna.👍👍 Mahu tanya. Kalau jenis valve mana yang lebih sesuai? Spring valve atau flat valve?
Keduannya sesuai tetapi bergantung pd kualiti produk itu sendiri....
Assalamualaikum tuan , t.kasih penerangan yg cukup lengkap , cuma sy nk tanya dekat paip utama dr meter x perlu letak check valve juga ke in case air dr meter utama tiada bekalan air , air dr tangki air akan pergi ke piping meter utama jika tiada check valve
Kalo ada water filter xperlu dan air xkan melepasi meter air..meter air pun bersifat one way valve jg.......
Air xkan keluar melalui paip meter,sbb paip inlet dari meter berada d bhgian atas tangki..air xleh panjat masuk lubang paip..hehe
jazakallahu khair kasira ustaz fairuz
Penerangan yang jelas….
Tuan pertanyaan..kegunaan air tangki 2 saluran 1 kebilik air bawah..1 lagi ke bilik atas..masalhnya air bilik atas tk selaju bilik air bawah..jika sy pasang check valve utk bilik air atas shj..ada problem ke .dri segi kebaikan atau keburukkan..
Nanti cuba
Masalah bypass ini , air di tangki ada chlorine masa fresh dari sumber
Tapi bila terlalu lama tinggal di dalam tangki , chlorine tu sudah tak ada, bacteria dah kulat pula Akan datang. Masa tak ada air, tak tahu air dari tangki itu selamat atau tidak.
So guna cara ini , perlu clear tangki air atau rajin Cuci air dalam tempoh beberapa hari atau minggu. Atau guna booster pump terus.
ilmu yg bermanfaat bang.. terima kasih
bagus ini idea.. tapi saya nak buat lantai cam tuu lahhhh siapa leh buat
buat sendiri jer slow2 bang, nnti sy upload cara buat...
nak tanya, dari tangki tu ada dua outlet. selepas stock.cock saya nampak ada paip yang naik ke atas... yang tu pergi mana? atau atas ditutup (utk create pressure?)
Rumah saya dua tingkat. Bilik tingkat atas di bawah tangki tak ada masalah. Tingkat bawah tak ada masalah. Tingkat atas belah lain dari tangki, pressure rendah, sehingga shower tak ada air langsung. Ini masalah air lock ke pressure tangki? Saya cuba release airlock macam video RUclips macam tak berkesan, mungkin cara salah. Lebih baik pasang terus pump kat tangki atau modify tambah check valve macam ini dah cukup? Atau apa cara release air lock yang betul?
Inlet paip (sebelum T - yg salur ke 2 paip outlet)perlu yg ada satu check valve, supaya air tangki tak turun ke meter, jika tiada bekalan air.
Blh letak kat slpas meter kalo mahu...kalo letak kat sblum T tu air xkn dpt supply pd bagian outlet direct dr main jika main pipe xde air
sy faham, sy pun berfikiran mcm tu.
@@zulhishamhashim7505 saya pn faham mcm den maklumkan. Air dr tangki akan kembali ke main paip syabas. Check valve selepas stopcock
klau valve dpn tutup dia tidak akn ke mn2
@@alakhir9020 check valve yg selepas meter tu bertujuan mengelakkan terjadinya "sucking" @ negetive pressure @ back flow ke dlm mainline bila air tiba2 slow atau lagi teruk, air putus (kalau tak sempat tutup main valve). Semua air yg ada dlm service pipe kita tu blh tersedut balik masuk ke comm. pipe & main pipe syarikat air.
Terbaik penerangan tuan, sy dh pasang cv mmg air dlm bilik air laju, cuma nak tanya bila tutup stopcock utama naik ke tangki air dlm bilik air jadi slow sangat, apa masalahnya ya tuan?
Pressure dr main pipe yg bantu lajukan air....jika tiada aliran dari main, pressure akan jd sedia kala
Terbaik lah bangunkan.
Cutter paip kita guna sm la bang...warna biru pun sm😂🤭
salam tuan..klau kite psang valve je pda out dri tngki tanpa baypas dri incoming boleh ke???
boleh dan tiada apa2 efek..
Hi fairuz. Sambungan paip di video utk brp bilik? Biasa rumah 2 tingkat ada 4 bilik mandi. 3 bilik mandi di tingkat 1 Dan 1 di tingkat bawah. Macam mana nak pasang bypass? Fairuz ada buat pemasangan di kawasan klang
Bukit tinggi 2? Terima kasih.
Biasanya outlet depent brp jumlah bila mandi biasanya...kalo ada 4, maknya ada 4 outlet....
sent gambar dkt tangki air dr semua sudut kt wasap 010 339 2020 and i quot kos buat....
Air dari main kena taruk check valve kalau tidak air akan gostan ke meter bila main X ada air
Tangki atas tempat tinggi bumbung mmg ada graviti dan tekanan.. Kalau tangki letak bawah rendah boleh ke buat gini tanpa water pump
Sy blm pernah cuba...tp firasat sy akan laju lbh sikit shj...
Bang ada video cara pasang waterpump ke paip tangki ka
Salam tuan... Klau tak pakai tangki hitam tu... Bole ke pasang by pass tu
yg ada tangki ajer tn....sbb dr tangki tu lah kita amik tekanan...
Baik2... Tq
Assalamualaikum bang… sy tgk abg ajar ni mcm sy boleh buat tp masalahnye jenis paip xsama😅… abg boleh tlg x cmne kalau paip lama main paip besi…outlet air ke toilet pvc… cmne sy nk buat bypass… umh sy paip mmg slow terus… penah pakai water heater yg ade pump pun xlarat nak pump…
Waalaikumsalam, nk tanya, rumah ada tangki x? @ ambil direct semua dari main pipe? Kalo xpakai tangki xblh buat. By the way, pvc dan paip galvanised saiznya sama shj.... blh pakai samada penyambung yg ada bunga (threat). @ lbh senang gi kedai hardware tanya brng apa perlu pakai utk material paip lain jenis...
@@fixfairuz1808ada tangki bang… cuma main paip air masuk tu jenis besi saiz rasa mcm besar dr paip outlet pvc dan bersaiz kecil sikit… ukuran saiz xbrp pasti sbb xde plak tulis kat situ…
Tq share❤
Nak tanya. Kenapa x letak check valve kat incoming? Kalau incoming tiba2 xde air, air x balik ke incoming ke?
Tak silap.Klu pressure dr main paip lebih tinggi dr tekanan tangki. Bypass flow selepas check valve xkan masuk ke laluan output. Hanya akan lalu jika press dr main paip lebih rendah dr tangki
mmng tugas check valve @ one way valve utk air dr luar xmelepasinya....
Kalau rumah ada 3 bilik air berasingan (ada shower, sinki dan tandas) tekanan nya masih tinggi ke atau kurang?
Hi , Boss , nak tanya , kalau Air Main tak masuk dekat by pass tu , kira air tangki juga akan turun balik pipe Main ke ?
Betol...air tangki akan berfungsi spt biasa.....
Encik, adakah penggunaan check valve perlahankan aliran air/mengurangkan tekanan air?
menguatkan tekanan aliran air
Kalau dah pasang bypass ni,mcm mne kte nk guna air melalui tangki .. adakah kena bukak kunci?? Dan mcm mne kte nk pkai air melalui direct? Kena buka kunci jgak ke..boleh terangkn mcm mne sistem dia
pendek cerita...kedua2nya berfungsi. Tiada apa2 kunci diperlukan...stopcock yg dipasang itu cuma utk safety....jika ada paip bocor pd 1 bhgian.hanya tutup stopcock itu shj tanpa perlu tutup stopcock dkt meter air tu....jimat tenaga xperlu turun naik semasa kerja2 repai dilakukan.
Kalau buat macam ni pasang check valve, air dari tanki dah tak boleh guna lah ya?
Air tangki akan keluar spt biasa dan dibantu tekanan keluar bersama air direct dari meter.....kalo tanya percentage sy kurang arip cara nk kira...ttpi bergantung pd keadaan graviti smadasama byk atau salah satu akn keluar minima, satu lg kwluarkan air secara maksima...
Salam bang terima kasi ilmunya
Cuma mau tanya sambungan bypass dr meter tu tak perluka pasang oneway valve sbb air dr tgki akan bepusing balik masuk ke tangki ikut laluan by pass tu sbb drumah saya mcm tu terus overflow@ rumah saya ketinggian tangki tak betul
ni. overflow, kemungkinan kedudukan valve xbetul...tuan kene lukis mngkin sy akan fhm....penerangan tuan xbrp jelas.
Sepatutnya air dari tangki takan masuk balik ke paip utama bila tiada air masuk sebab paras air masuk dalam tangki adalah tinggi (bersekali dengan pelampung).
kan dia dah bypass td😅.. bukan keluar dr pelampung tu.. keluar dr outgoing la masuknke meter balik.. sebab dalam kes ni dia dah bypass incoming dan outgoing dr satu paip dan laluan yg sama.. one way valve hanya menghalang incoming masuk ke tangki melalui outgoing..tapi dia tak halang dr outgoing ke meter sebab dia tak pasang one way valve kat incoming.. tp saya ada baca komen.. air dr dalam rumah tak kan melepasi meter sebab meter tu pon sebenarnya bersipat one way direction jugak..
Salam tuan. Nak tanya. Klu sebelum kita buat kerja paip ni, tapi tangki tak diskosongkan dulu sebaliknya tutup saja valve outlet dari tangki, ada apa2 perbezaan tak? Atau mmg nak kena kosong kan jugak dulu tangki sebelum buat kerja2 paip? Mohon penjelasan tuan 🙏🏻
Seblh2nya kosongkan.... sebab kalo bocor jd 2x kerja... utk rumah sendiri ok...mcm sy jd byk kerja billa owner rumah call ada bocor....rugi masa dan kos ulangalik serta brng perli ditukar baru....xsalah blh cuba...
Ko masuk direct dari paip utama memanglah laju bonggok..aku nak tau dari tangki naper air slow walau dah ade overflow..tunjukkan cara dari tangki..
Perrgghhh... hebat benar kau bonggok kan org... kau nak minta tunjuk ajar dari org, tapi kau bonggokkan org tu... kau yg bonggok sebenarnya 😂😂😂😂 berbual konek...
Encik, nak tanya sikit berkenaan dengan air dari tangki yg beri tekanan kepada main pipe/direct. Katakanlah kalau tiada air dari main pipe/meter air, bukankah air dari tangki akan mengalir masuk ke meter air? Jadi adakah patut letak satu check valve selepas meter air?
Tgk level rumah...jika tere sama level xde masalah kecuali rumah kita level tunggi dr rumah org lain....itu blh pasang 1 lg check valve slpas meter air...kalo ada pakai penapis air yg besar tu dkt dgn meter air tidak perlu check valve...
Rasanya meter air dia mcm check valve jgk kalau psg terbalik meter air tu air tak akan kelua jdi kalau tak ada air dri paip utama rasanya air tak akan mengalir ke meter
Salam bro kalau kta pas g 1 way valve ni yg dri meter air adakah meter nya akan jd laju berpusing tak
xde laju..nape nk gi ke meter lak..sy xbrp fhm tn.
Lepas stock cock dari outlet tangki ada paip pvc yg tegak panjang tu utk buang angin ya... Ini you tak explain
Bkn keperluan..ada ok..xde pon xper...
Salam tuan buat area mana? Area Melaka boleh buat ke?
Sy di Sepang.... Melaka agak jauh... tp ada jg customer sanggup bayar add. charge... blh brhbng dgn sy ditalian wasap 0103392020
Air dari paip main dah slow nak buat mcm aner
kalo dr main ke panggil Syabas @ mana konsesi negeri, mntak diorng bukak valve besar sikit....tp kalo tekanan stay rendah jgk kwsan tu terpaksa pakai pam elektrik lah
saya dah buat check valve dari tangki tak mau bukak dari pressure tangki tak kuat nk tolak valve tu kalau tutup air direct.. maknanya dia guna pipe air direct je sebenarnya.. tutup direct dari tangki tak keluar setitik pun.. jd tak ada function la air tanki.. igtkn bila buat sistem mcmni air tangki dgn air direct bertembung jadi labih kuat air.. rupanya bukan.. hmmm dia baypass jd sistem tangki stop direct je yg jalan.. kalau direct mcm air luir meleleh mmg xfunction langsung.. rasa kecewa pulak.. hmmm
Pertama tuan kena pastikan sambung dan kedudukan check valve itu betul....kedua pastikan juga tiada mana2 paip yg tersumbat @ ada halangan utk mengalir secara sempurna... ketiga baru kita check keseimbangan graviti pepasangan kita.....
Pemakaian Tanki air di perlu kn jika tekanan / kederasan ( main)sumber Air tidak mencukupi dan booster pump harus di beri pilihan jika tekanan air melalui gravity juga tidak mncukupi. Jika tekanan dari sumber air mencukupi maka tanki dan booster pump hya digunakn pada waktu2 darurat. Dari itu saluran atau piping line harus diubah sesuai dan adalh Terlebeh baek mngunakn pipe dan tanki yg terbuat dari bahan stainless Steel yg tahan lama dan tahan karat daripada mngunakn PVC pipe . Dalam isu ini Perlu diingat juga Tanki harus dirawat.
As salam bang. Klau tak pkai paip 'air release', ada effect tak kpd kelajuan air keluar.
Waalaikumsalam...sy xpasti sbb blm pernah cuba...tp pernah buat utk paip jenis poly/hansen mmng xde pon dr asal....
Assalam tuan. Bermakna kita menggunakan air dr paip meter lah ye. Bl paip meter xde air, baru lah air tangki digunakan. Betul ke mcm tu tuan. Saya keliru jgk tu 😄
Waalaikumsalam...dlm soalan2 berkaitan dh byk sy jwb....mohon tuan refer kt situ yer tuan...
Kalau nak buat sistem air utama xde air dan gunakan air tangki.mksd saya bila air meter takde auto air tangki turun..
Salam bang....yg paip ventinya kena sebelum check valve ka?
kebiasaanyalah....
Salam bro... saya tak faham di dua tempat ni, minit 23:06 dan 23:17 Apa fungsi paip menegak panjang ni, satu selepas stop-cork out-going dan satu lagi sebelum...??
paip menegak tu utk release angin ....mesti tinggi sikit dari tangki....biar kan terbuka...
@@fixfairuz1808 Ok... terima kasih bro... terbaik.
xampamham amkumm ampem mendemm 🤣😂
Salam...boleh nak tahu kalau pakai sistem paip mcm ni...di mana tempat nak letak pump air ye tuan....pump utk tarik air masuk tangki
Waalaikumsalam...cuba google ' cara betul pemasangan booster pam... dia ada gambarjah...sy nk terangkan pon pnjng sgt....
Assalamualaikum bg.. nak tanya kalau air kt rumah takda, air tangki tu boleh guna jg ke? Ke kena ada air dari meter bru air keluar?
boleh guna air tangki bila2 masa....
Kalau tangki stainless steel letak dibawah dan sy tak pakai motor, boleh guna juga ke teknik ni?
Blh....xde masalah....
Kalau ayer pressure ta- kuat boleh-ka ? Saya pasang check valve bagi dia kuat Dari tanki ke rumah atas . Terima kasih
.
sbnarnya bypass tugas dia utk bantu kuatkan pressure tetapi utk betol2 kuat terpaksalah pakai pam...
Dari tangki boleh ke pasang bypass
apoo🤣 aku okay je potong poli pakai grgaji, brtahun² dh buat plumber, xde kluar pun air. jnji pasang soket tu btul, xde trbalik².. potong pun kena lurus.. 🤣🤣
tu bezanya profesional dan kampung
@@FreemanSurplusapa kena mengena dengan kampung lak? kau duk profesional ke duk bandar? nak buat perbandingan pun tak betul.
Bila kita hendak menjadi guru biarlah ajar benda yg betol, selamat dan memudahkan..apa guna sesuatu alat dicipta?.apa guna compressor dicipta walhal berus cat lg murah...samalah perbandingan apa yg kamu kata gergaji pon blh....bkn setakat gergaji, dengan parang pn blh....kdng2 soal keselamatan pon kene fikir jgk...kualiti kerja pasti bagus jika kita menggunakan peraltan yg betol....itulh yg dipanggil orang 'kompetan' dlm dunia teknikal...
Bang .. Kalo ade 2 outlet tp cume pasang 1 jerrr check valve... Ok ke
Blh jer...kalo blh sblm berpecah gunakan paip yg saiz lbh besar sedikit dr 2 outlet td....
Klu dari meter terus tak pkai tangki boleh buat dak
Blh sangat dan xperlulh pakai check valve.....tp kalo semua direct dr meter air nnti air xde semua xleh pakai tau...dan air tangki nnti dh rugi xguna.....
Ada satu paip T yg pergi ke atas tangki sambung pg kmana bang?
Itu paip utk 'air release, ketinggian mesti melepasi takat max. tangki...
Nie namanya baypass tank. Air datang terus dari air paip ke bilik air. Bila air paip tak de baru, air dari tangki akan keluar. Sebenarnya tak bagus sebab air tangki disimpan terlalu lama, bakteria cepat membiak dalam air tangki. Cara terbaik air tangki harus sentiasa digunakan. Tarik paip dari tangki ke mesin basuh atau mane tempat yang sesuai. Jangan tarik ke sinki atau penapis air. Cara ini dapat mengurangkan pembentukan bekteria dalam tangki air.
blh bg 1 sbb knp air dr tangki tidak digunakan kalo ada bypass....? adakah air itu bersifat keras mcm batu? tidak blh bergerak walau sedikit? biat komen blh diterima akal
Pandai
nk tanya balik, apa kegunaan check valve @ 1 way valve? knp digunakan?
Ko ni giler ker aper.....try buat aper...dh beratus aku buat....ko pehal giler camni....?
Tgk video tu biar smpai abes...kan dh xfhm...org leng ok jer fhm...semua dh bgitau kt situ.. rasa xbetul, buatlh video awk yg betol sgt tu....tgk ada org nk tgk ker x....