Potentiodynamic Corrosion Testing Protocol (step by step)

Поделиться
HTML-код
  • Опубликовано: 4 окт 2024
  • A protocol to set up and run a potentiodynamic corrosion test for metals.

Комментарии • 31

  • @thermalhub
    @thermalhub 2 месяца назад

    Clearly demonstrated sir. Thank you👍

  • @simonblue56
    @simonblue56 4 года назад

    Clear demonstrations!

  • @puskarpathak8913
    @puskarpathak8913 3 года назад

    insightful, thanks for sharing

  • @leepeter5643
    @leepeter5643 5 лет назад +1

    HI THANK YOU VERY MUCH FOR THIS VIDEO, PLEASE CAN YOU MAKE ONE EXPLAINING THE CURVES GAINED FROM THE EXPERIEMENT - SUCH AS TAFEL PLOTS - WHY WE USE THEM/ WHAT THEY ARE AND WHAT THE GRAPHS MEAN IN TERMS OF CORROSION? Very good video and would love to learn more!

  • @vireshpatil3469
    @vireshpatil3469 6 лет назад +1

    THANK YOU SIR

  • @vinithgr9148
    @vinithgr9148 6 лет назад

    Hi it was very useful can you elaborate the Tafel calculation methodology followed after the studies are over, thanks

  • @azimadzlan445
    @azimadzlan445 4 года назад

    Thank you for the video. May i know how we set up the initial and final E (V)? Is it depends on material and area?

  • @learngrowwithimran8208
    @learngrowwithimran8208 6 лет назад

    Thank you sir. Why we use potentiostate here.

  • @ghaithms9285
    @ghaithms9285 4 года назад +1

    Hey first of all thank you very much I'm working on similar project and I think I have something to ask you do you have any emails or how can I contact you ?

  • @hayathaddad4535
    @hayathaddad4535 3 года назад

    Thank you very much for the explanation, i have a homework and i have some questions about this. Can you help me ? How can i contact you :)

  • @gyaniyumnam7266
    @gyaniyumnam7266 3 года назад

    i want to know the price of the instrument

  • @mohanparamasivam3951
    @mohanparamasivam3951 5 лет назад

    Thanks for this informative video.
    What will be impact of initial delay time wrt to end results?

    • @metallovers8226
      @metallovers8226  5 лет назад +1

      you have to wait until open circuit potential reaches a steady state before PD tests in order to produce reproducible results.

    • @mohanparamasivam3951
      @mohanparamasivam3951 5 лет назад

      Thanks for your reply.
      But my actual doubt is :
      Say we are keeping 5 mins initial delay and 1hr initial delay, will the results be accurate in both cases. If Yes / No - Why it is So?

  • @sukunmandal-
    @sukunmandal- 2 года назад

    Bro e test mujhe kaha milega karwanekeliye

  • @lungazulu2760
    @lungazulu2760 5 лет назад

    Thank you for the video, this will definitely help me with my project , may i please ask, if you have 4 samples to test, after each test, do i have to redo the cleaning, i will be using the same electrolyte sample and different metal samples. Also , the counter electrode, does it need to be changed?

    • @metallovers8226
      @metallovers8226  5 лет назад +1

      The test itself may change pH of the electrolyte, it is better to repeat the cleaning and use new electrolyte every time.

  • @DrMa10
    @DrMa10 6 лет назад +1

    is Tafel test destructive? Does it cause damage to the coating ?

    • @wen2jun1cai4
      @wen2jun1cai4 6 лет назад

      Yes it will.

    • @DrMa10
      @DrMa10 6 лет назад

      i see.. thanks..need to learn more from u

  • @john110503
    @john110503 3 года назад

    can i use a phase change material as an electrolyte to check corrosion?

    • @metallovers8226
      @metallovers8226  3 года назад

      As long as it has some conductivity.
      en.wikipedia.org/wiki/Conductivity_(electrolytic)#:~:text=High%20quality%20deionized%20water%20has,electrolyte%20in%20a%20Wheatstone%20bridge.

  • @raghavakumarvanama9074
    @raghavakumarvanama9074 6 лет назад

    does this testing useful for measuring corrosion rate of reinforcement bar in concrete (R.Concrete member is wrapped with external FRP system)??

    • @metallovers8226
      @metallovers8226  6 лет назад

      The electrochemical part is the same, but the sample prep and container will be quite different.

  • @isaiahgonzales6727
    @isaiahgonzales6727 5 лет назад

    what is the standard statistical analysis used in this protocol?

    • @metallovers8226
      @metallovers8226  5 лет назад +1

      based on the number of repeated tests that one performs, average, standard deviation, range etc. of measured data can be calculated.

  • @Hakunamatata53191
    @Hakunamatata53191 6 лет назад

    I suppose the corrosion cell/vessel was made of Teflon. was it custom made or does any company supply them?

    • @wen2jun1cai4
      @wen2jun1cai4 6 лет назад +1

      This particular one is custom made. You may use any non-corrosive container (e.g. glass beaker/tank) for your experiments.

    • @t.dexter4448
      @t.dexter4448 6 лет назад

      hatchegg that's an awesome video. can you please provide the name of the company that custom-made your cell and coupons?

    • @metallovers8226
      @metallovers8226  6 лет назад

      They were designed by graduate student and fabricated by the machine shop at USF.

  • @MinuteMayne
    @MinuteMayne 3 года назад

    Yo you're pouring acetone down the drain wtf!