Master your connections - Shear connections

Поделиться
HTML-код
  • Опубликовано: 5 янв 2025

Комментарии • 5

  • @LaesgcEngineering
    @LaesgcEngineering 4 месяца назад

    thank you so much for sharing, insightful content

  • @Facvideoss
    @Facvideoss 3 месяца назад

    Good day if the consultant insist that the forces should be applied on the Node so that a momentdue to eccentricity is generated what is the proper way Should it be on Node or on the Bolt thank you 🙏

    • @ideastatica_en
      @ideastatica_en  3 месяца назад

      If you design a connection with a hinge (pinned connection) = in your global structural model, there is no moment in the node, only a shear force, then in IDEA StatiCa you set the position of the shear force to bolts (center of rotation in the hinge).
      www.ideastatica.com/support-center/how-to-define-correct-load-position
      If in the global model you have bending moment in the node (semiridig or rigid connection) then you dont move the shear force position in IDEA StatiCa and leave it in the node.
      In other cases when you want to elaborate and achieve a perfect alignment, you can use the manual set of position of shear force and thus moment diagram shift.

    • @Facvideoss
      @Facvideoss 3 месяца назад

      @@ideastatica_en thank you ❤️❤️