How AVR works? How AVR regulates the voltage ? AVR working principle in Hindi Urdu

Поделиться
HTML-код
  • Опубликовано: 7 янв 2025

Комментарии • 130

  • @نصرالدينجليلة
    @نصرالدينجليلة 11 месяцев назад +2

    شكر الك انت رجل مسلم وهذا فخر للأمة الإسلامية من فضلك ضع الترجمة باللغة العربية او الفرنسية اخوك من الجزائر عامل في شركة الكهرباء والغاز الجزائر هذه الدروس مفيدة لنا

  • @khalidsatti9847
    @khalidsatti9847 2 года назад +2

    I have naver seen such a good teacher ..... what a good method of teaching ....... salute sir

  • @yutubkuful
    @yutubkuful Год назад

    wa'alaikumussalaam
    Hi Sir.. im Indonesian,
    Useful Video about Generator
    bery Nice n Thanks u👍

  • @BasuraD
    @BasuraD 2 года назад +1

    What an excellent explanation ! you are amazing in teaching Sir.. I'm a Maintenance Engineer from Srilanka.

  • @abdulazizkhan6222
    @abdulazizkhan6222 Год назад

    Well explained. Great. Like your lectures

  • @deeprajshanker2325
    @deeprajshanker2325 Год назад

    Great source of DG knowledge..thank you

  • @facereader99
    @facereader99 3 месяца назад

    Very nice. Thank you very much!

  • @smhbukhari
    @smhbukhari 7 месяцев назад

    Brother very nicely explained thanks

  • @sfplpowerhouse7143
    @sfplpowerhouse7143 2 года назад +1

    Kia baaat h bht khoob ...

  • @pardesi111
    @pardesi111 3 года назад

    exceelent ..stay blessed keep working :-)

  • @MrDillipkdash
    @MrDillipkdash Год назад

    Nicely explained Sir..Just a req...if you can make a video in AVR circuit and how it works,that would be more useful and defects related to generrators.Thank you so much for so many educacative videos.

  • @pakistanifoods4525
    @pakistanifoods4525 3 года назад +3

    Great..... Sir

  • @innermagnet8288
    @innermagnet8288 3 года назад +1

    Good..keep it up👍

  • @jonnasivaram1661
    @jonnasivaram1661 3 года назад

    Excellent video bhai

  • @kpomblekoukoudjo4173
    @kpomblekoukoudjo4173 Год назад +1

    Salut 🙋👍🏻👍🏻💪🏻💪🏻🙏🙏

  • @kishanbanjare5675
    @kishanbanjare5675 7 месяцев назад

    Thanks you sir 🙏

  • @chintanmehta4695
    @chintanmehta4695 Год назад

    Great explanation sir

  • @harrysinghpharswan3990
    @harrysinghpharswan3990 3 года назад +1

    AVR seperately axcited generator me kese kaam krta he?? Agar seperately axcited generator me v axcited rotor or motor lge hote he to self excited or seperately excited generator me kya antr rah jayega??? Ans please

  • @VikramSingh-gp9hj
    @VikramSingh-gp9hj 2 года назад

    Good sir bhout accha sir transformar end Avr dono mey kaamyaab konsa hai

  • @mastufakamal452
    @mastufakamal452 3 года назад +2

    I have a request bai, please make video for how connection identify alternator terminal box (all sensor & Engine control connection from cat Generator).

  • @mohammadrashid8678
    @mohammadrashid8678 3 года назад +1

    thanks bhi

  • @nikhilpalode3990
    @nikhilpalode3990 8 месяцев назад

    2 hours bad Voltage Variation hota hei AVR 449 and 731 Hei kya problem ho sakta hei

  • @Shahlazaidi7
    @Shahlazaidi7 3 года назад +1

    Masha,Allah

  • @haidermehdi1735
    @haidermehdi1735 2 года назад

    جزاك اللهُ‎

  • @rkgraphics9243
    @rkgraphics9243 Год назад +1

    Avr take in put from pmg ....how many voltage pls...?

  • @dineshdxx
    @dineshdxx 3 года назад

    Superb 👌

  • @azharaziz7856
    @azharaziz7856 2 года назад

    Asad bhai AVR duty cycle kia hota ha genset k display pe?
    kia kam hota ha iska?

    • @AsadElectrical
      @AsadElectrical  2 года назад

      Duty cycle ratio ya percentage ko kehtay hen. kisi bhi equipment k kaam karne ka ratio

  • @asimyounus3492
    @asimyounus3492 2 года назад

    PMG using for what purpose you saying in your video for sensing are you sure about it, and also what is dynamic excitation you know about this system.

    • @AsadElectrical
      @AsadElectrical  2 года назад

      PMG makes regulation more reliable and stable instead of self excitation.
      ruclips.net/video/yXRJVzZgR-A/видео.html

  • @mmhshajib
    @mmhshajib Год назад

    I have a one query...about voltage control and load control.
    Actually when we need to increases or decrease voltage/load set.. avr only feed excitation current to exciter where as rom almost fixed. But i want to ask u what happen when excitation current feed to exciter from avr to fulfill our setpoint (either volt increases/Decrease Or load increases/decrease) ...confusion is here that field excitation is same but why volt increases or load current increases..

    • @AsadElectrical
      @AsadElectrical  Год назад

      Excitation field is not fixed, its always vary on load

    • @mmhshajib
      @mmhshajib Год назад

      @@AsadElectrical may be I can not explain quesrion perfectly ..
      Suppose: rpm 500, load 18mw, volt 11kv, current 1200 A, excitation current 10A, excitation volt 105 volt, pf 0.8,
      If we change pf 0.8 to 0.85,
      Gen volt, load is being same, rpm same, just output current getting low Slightly.
      My question is actually it's control by excitation feed by avr. But excitation feed is send to aux exciter, then it creat 3 phase power to diode bridge, then pure DC actual feed to main rotor field ..which is totally not physically connected with any control.
      How this actual rotor field control for pf 0.85 and actually what is going on this situation.
      Any body can explain??

    • @AsadElectrical
      @AsadElectrical  Год назад

      Physical connection is not necessary because magnetic fields also work to reduce or increase amps.

  • @asimyounus3492
    @asimyounus3492 2 года назад

    If we have a PMG do we need residual voltage for initial magnetic field

    • @AsadElectrical
      @AsadElectrical  2 года назад

      Yes, but PMG helps if residual magnet get lost

  • @majeedullah1528
    @majeedullah1528 Год назад

    Dear sir
    AOA
    We can only pray for your health and happiness, may GOD bless you.
    I've one question
    Suppose from AVR's output sensing volt is 30 volt dc to excitation stator then this excitation voltage convert it into AC VOLT then again this AC convert it into DC by rotating bridge rectifer , which will again same 30 volt dc? this dc provide to main rotor
    AVR output Sensing volt and main rotor dc supply voltage from bridge rectifer will same ?
    My question is this.

    • @AsadElectrical
      @AsadElectrical  Год назад

      W,salam. After conversion voltage will be increase but we can check only Exciter stator voltage with multimeter and main rotor voltage are different also we cannot check it.

  • @bablumirza234
    @bablumirza234 2 года назад

    Sir singal fase me avr lagane ke liye diwod konse nikalna he please bataye connection samajh me aagaye par diwod kese niklenge

  • @Devbhoomidevdarshan
    @Devbhoomidevdarshan Год назад

    Same procdure in brushless excitor system ?
    If we don't get y phase of residual voltage during synchronised generator in power plant then what is the main cause ?

  • @fazalkareem3469
    @fazalkareem3469 3 года назад +1

    MashaAllah

  • @mukeetkhan6317
    @mukeetkhan6317 3 года назад +1

    Thanks sir

  • @ajaysahu4654
    @ajaysahu4654 3 года назад +1

    Superb

  • @rakeshlalgotraele4103
    @rakeshlalgotraele4103 Год назад

    Sir excitor me chumbak q lagate hai plz bataiye

  • @Complete501
    @Complete501 Год назад

    Sir written notes mil sakte hai kya pls?

  • @A.h-95
    @A.h-95 Год назад

    Asslam alikum bhai

  • @naveedjamal1725
    @naveedjamal1725 2 года назад

    Asad bhai dvr ko bhi breif kre and AVR aur DVR mein difference bhi btae

    • @AsadElectrical
      @AsadElectrical  2 года назад

      ruclips.net/video/ymxpGTpsT2E/видео.html

  • @asimyounus3492
    @asimyounus3492 2 года назад

    And also explain why first we convert from AC to DC then again From DC to AC and finally convert AC to DC.

    • @AsadElectrical
      @AsadElectrical  2 года назад

      Because we need DC supply to make constant magnetic field around the rotor.

  • @santoshbhagat1927
    @santoshbhagat1927 3 года назад +1

    Sir till now not explained the generator rotor earthfault protection system with diagram

  • @mrehan.140
    @mrehan.140 Год назад

    Sir please one video on PMG

  • @wasimedoo7994
    @wasimedoo7994 2 года назад

    How much ohms does the exciter coil is thanks bro keep it up

    • @AsadElectrical
      @AsadElectrical  2 года назад +1

      Exciter field is about 4 ohms and exciter rotor is less than 1 ohms

    • @wasimedoo7994
      @wasimedoo7994 2 года назад

      Thanks that is for big generator like 10 k and up

  • @maintenancefluidcalculatio6156
    @maintenancefluidcalculatio6156 2 года назад

    💗💗

  • @rollylinogao6895
    @rollylinogao6895 2 года назад

    Sir can you add English subtitle. It would be a big help for us who didn’t understand other language. Thank you

  • @ashishvitekar3474
    @ashishvitekar3474 3 года назад +1

    Very nice explain and informative video's, But couldn't understand residual voltages available in stators

    • @AsadElectrical
      @AsadElectrical  3 года назад

      ruclips.net/video/nCvgO4-K3Js/видео.html

    • @babunawaz4808
      @babunawaz4808 2 года назад

      @@AsadElectrical THANK YOU MY GOOD TEACHER ..ALLAH HELP US..my NAME MUHAMMAD NAWAZ..

  • @jagumane4995
    @jagumane4995 3 года назад +1

    👌💐👌💐

  • @masumakand440
    @masumakand440 Год назад

    If PMG excitation produces 60 to 70 voltage then what will be the mains excitation voltage.

    • @AsadElectrical
      @AsadElectrical  Год назад

      Main Excitation voltage remain same, PMG only helps AVR

  • @mrmirza7680
    @mrmirza7680 3 года назад

    What is residual voltage? How its produced? Plz mention link of ur video thanks

    • @AsadElectrical
      @AsadElectrical  3 года назад

      ruclips.net/video/nCvgO4-K3Js/видео.html

  • @jaldeeppatel3222
    @jaldeeppatel3222 Год назад

    AC input Acoutput AVR ho sakta hai

  • @sagarkjadhav4194
    @sagarkjadhav4194 2 года назад

    Sir aap kaha se ho

  • @md.khairulislam16
    @md.khairulislam16 3 года назад

    Assalamualicum Sir. Could you please inform that how much sensing voltage come in AVR for 11 kv alternator??

    • @AsadElectrical
      @AsadElectrical  3 года назад

      Its depend on AVR. 11 kv step down to 110, 220 or 380 from PTs than come to the AVR

    • @AsadElectrical
      @AsadElectrical  3 года назад

      Walykum assalam

    • @md.khairulislam16
      @md.khairulislam16 3 года назад

      @@AsadElectrical Sir Thank you so much. Kindly make video about this very soon 🙏🙏

  • @haseenakhter6815
    @haseenakhter6815 3 года назад +1

    Assalamualaikum

  • @vivekbhardwajofficial9276
    @vivekbhardwajofficial9276 3 года назад

    How to check efficiency of DG set

  • @taimoorkhan-rl1lt
    @taimoorkhan-rl1lt 2 года назад

    If generator is off than from where the excitor will get the initial field supply ?

    • @AsadElectrical
      @AsadElectrical  2 года назад

      ruclips.net/video/nCvgO4-K3Js/видео.html

  • @Santosh-em1yw
    @Santosh-em1yw 3 года назад

    Sir avr panel me null meter ka function kya hota hai...?

    • @AsadElectrical
      @AsadElectrical  3 года назад

      Ye output ko monitor karta he auto/manual modes par agar koi difference ho to signal deta he warna null rehta he

  • @ritika9777
    @ritika9777 9 месяцев назад

    Dc current kese rotating field bna sakta hai?

    • @AsadElectrical
      @AsadElectrical  9 месяцев назад

      Jab ham rotor ko rotate krengy to wo field bhi rotate hogi

  • @soumya2221
    @soumya2221 3 года назад +1

    Sir our gen pmg op voltage is 240v ac 275hz 3phase.. So why output frequency is so high??

    • @AsadElectrical
      @AsadElectrical  3 года назад

      PMG frequency is always high because of many poles in exciter and this is need because of smooth operation

    • @soumya2221
      @soumya2221 3 года назад

      Sir but how it becomes smooth by increasing no of poles and that in turns increses frequency

  • @DevendraSingh-pt1qr
    @DevendraSingh-pt1qr Год назад

    Bhaiya single ya three phase janeretor mai kis janeretor mai kaun sa avr lagega kaise ptaa karey
    Ya phir kitne volt ka avr lagegaa kaise ptaa karey

    • @AsadElectrical
      @AsadElectrical  Год назад

      As per manufacturer requirement

    • @DevendraSingh-pt1qr
      @DevendraSingh-pt1qr Год назад

      @@AsadElectrical bhaiya kisi bhi janeretor k liye avr select karne k perametar kya hai

    • @AsadElectrical
      @AsadElectrical  Год назад

      @@DevendraSingh-pt1qr generator rated voltage aur excitation current and voltage range k hisab se koi bhi AVR use kr sakty hen.

    • @DevendraSingh-pt1qr
      @DevendraSingh-pt1qr Год назад

      @@AsadElectrical bhaiya kitna excitaion volt aur reted current hone per kitne volt ka avr lagegaa

    • @AsadElectrical
      @AsadElectrical  Год назад

      @@DevendraSingh-pt1qr Generator nameplate pe uska maximum excitation current aur volt mention hota he uskay hisab se. Warna max 10 amps ka use krsaktay hen aur excitation volt 40 tak hona chahye agar 400 v ka generator he

  • @hasanshhadi2062
    @hasanshhadi2062 3 года назад

    hello dear, please may you add subtitles for the video because it's really difficult to understand your ideas.
    Thank you and all my respect

  • @suribabugorle4126
    @suribabugorle4126 Год назад

    Main rotor Input supply DC or ac

  • @anthonyjanz5404
    @anthonyjanz5404 2 года назад

    😍😍😍😍

  • @A.h-95
    @A.h-95 Год назад

    Kya krna chahiye. Senci ka ganretr

    • @AsadElectrical
      @AsadElectrical  Год назад

      ruclips.net/video/9fGOiYZN8Xo/видео.html&pp=ygUidm9sdGFnZSBwcm9ibGVtIGluIGdlbmVyYXRvciBhc2FkIA%3D%3D

  • @_vn_electronics_7563
    @_vn_electronics_7563 Год назад

    Avr se kitten volts DC generate hote hai

  • @eduardogutierrez8378
    @eduardogutierrez8378 2 года назад

    Hello AVR MX 341 point S1-S2 coneting? Out generators stator
    Thanks

  • @mdfarhadulislam7598
    @mdfarhadulislam7598 3 года назад

    Dear sir, How many loads have to have how many throttle positions

    • @AsadElectrical
      @AsadElectrical  3 года назад

      Hi. Your question is not clear

    • @mdfarhadulislam7598
      @mdfarhadulislam7598 3 года назад

      How much the throttle will open according to the load. want to know the use of woodward hand heald,
      thanks sir,

    • @AsadElectrical
      @AsadElectrical  3 года назад

      @@mdfarhadulislam7598 25 to 75 %

    • @mdfarhadulislam7598
      @mdfarhadulislam7598 3 года назад

      @@AsadElectrical 500kw,
      600kw, 700kw, 800kw, 900kw how throttle positions in cat 3516 A series gas engine

    • @AsadElectrical
      @AsadElectrical  3 года назад

      @@mdfarhadulislam7598 actually i am talking about diesel engine. for Gas engine you need to check with Cat ET

  • @Cris_P_Bacon.
    @Cris_P_Bacon. 3 года назад

    I hope there is english subtitle :(

  • @A.h-95
    @A.h-95 Год назад

    Volts jyda araa bhai

  • @muhammadsheraznawaz7777
    @muhammadsheraznawaz7777 2 года назад

    Bhai sirf avr ka samjho.... How avr works... Its Mechanism

  • @MD.Sultan-ot4op
    @MD.Sultan-ot4op Год назад

    ❤❤❤