pH Meter used in Pharmaceutical industry l interview Important Questions answers

Поделиться
HTML-код
  • Опубликовано: 17 янв 2025

Комментарии • 38

  • @naveenkumar-zh4vm
    @naveenkumar-zh4vm 15 дней назад +1

    Nice information 😊

  • @mukulpal5786
    @mukulpal5786 11 месяцев назад +1

    Great sir

  • @billa071
    @billa071 5 месяцев назад +1

    Greate information sir thank you ❤

  • @ajeetprajapati297
    @ajeetprajapati297 8 месяцев назад +2

    Thank you so much sir aap hum sab ke liye es topic ko itna achhe se identify karne ke liye ❤

  • @machhijagesh
    @machhijagesh 7 месяцев назад +2

    Aap kafi achi information dete ho . Bas kisi kisi videos me aap jab bolte ho oos samy ye zingoor ke jaise aavaj irritate karti hai.

  • @pravinsingh8170
    @pravinsingh8170 11 месяцев назад +1

    Sir ph meret me electred lod ke under jo wire hota hai wo kiska bana ho ta hai

    • @voiceofkayani5419
      @voiceofkayani5419  11 месяцев назад +1

      Silver based electrical wire with having KCl solution

    • @pravinsingh8170
      @pravinsingh8170 11 месяцев назад

      @@voiceofkayani5419 sir ap dript bole the ya tript

    • @voiceofkayani5419
      @voiceofkayani5419  11 месяцев назад

      @@pravinsingh8170 drift

  • @shalupal6998
    @shalupal6998 6 месяцев назад +1

    sir aap jis topic ko cover karte h kya oske notes mil jayenge

  • @kuldeepbiotech4014
    @kuldeepbiotech4014 11 месяцев назад +1

    Sir GMP practice par video banaiye please

    • @voiceofkayani5419
      @voiceofkayani5419  11 месяцев назад

      Ok sure, will make soon
      Just keep watching and sharing

  • @pravinsingh8170
    @pravinsingh8170 11 месяцев назад +1

    Sir tript ya dript

  • @pad480
    @pad480 11 месяцев назад +1

    How to perform slop calculations pH meter??

    • @voiceofkayani5419
      @voiceofkayani5419  11 месяцев назад +2

      It is calculated by instrument software it self....
      But manually is little how difficult...
      You should calculate valtage difference between 2 buffer's and divide it by difference of 2 buffer's ph

  • @mangeshvartha2820
    @mangeshvartha2820 6 месяцев назад +1

    Sir aapne ph ki range batayi lekin minimum range aur maximum range kitani chahiye ye nahi batayi. plz sir water ph range mini & max

    • @voiceofkayani5419
      @voiceofkayani5419  6 месяцев назад

      Dear,
      Plus minus range depends on method...
      Little bit vary...
      Normally +/- 0 2 hoti hai and Kam bhi....
      Water ki pH 7.0 hoti hai normally depends k water konsa hai.
      Water pH is pharmacopeial

  • @ramachandrarana7751
    @ramachandrarana7751 4 месяца назад +1

    Sir I dipped the electrode in pH 4 solution is it correct?

    • @voiceofkayani5419
      @voiceofkayani5419  4 месяца назад

      @@ramachandrarana7751 for calibration yes...
      After complete cleaning...
      Don't dip in stock buffer solution

    • @ramachandrarana7751
      @ramachandrarana7751 4 месяца назад +1

      @@voiceofkayani5419 sir i am storing the electrode in pH 4 and calibrating with 4,7 and 9.2 buffer

    • @voiceofkayani5419
      @voiceofkayani5419  4 месяца назад

      @@ramachandrarana7751 electrode never be stored in any buffer solution dear...
      Electrode
      Must be stored in saturated KCL solution

    • @ramachandrarana7751
      @ramachandrarana7751 4 месяца назад +1

      @@voiceofkayani5419 Tank you sir, I was going in a wrong way

    • @sonukumarpatelverynicesir3965
      @sonukumarpatelverynicesir3965 25 дней назад +1

      Which company are you working

  • @shyamthakor6617
    @shyamthakor6617 9 месяцев назад +1

    Sir can you explain important of mV in using of pH meter

    • @voiceofkayani5419
      @voiceofkayani5419  9 месяцев назад +1

      mV has very important role in measure of pH in any solution.
      pH is potential difference between sample and reference measure in mV. Which is used to calculate the pH of sample via calibration curve. So Mili volts has very important role in pH meter during pH calculation.

  • @vikasgupta3544
    @vikasgupta3544 5 месяцев назад +1

    Sir sample ka temperature kitna hona chahiye

  • @pravinsingh8170
    @pravinsingh8170 11 месяцев назад +1

    Kal kiten molar ka hota hai

    • @voiceofkayani5419
      @voiceofkayani5419  11 месяцев назад

      Normally used saturated solution of KCl

    • @shahzadsirang2707
      @shahzadsirang2707 10 месяцев назад

      Pravin Singh mainly 3 M kcl use hota is me hum ph meter ka electrode depth kar ke rakhtn hn.

  • @SOUVIKPANDA725
    @SOUVIKPANDA725 6 месяцев назад

    Hi sir. App Merck main job karte hain?

  • @shan_kr
    @shan_kr 2 месяца назад +1

    Sir agar subtitles de dete toh achha hota😢