Easy to connect PLC S7-200 SMART communication with LAN cable by using Step7 MicroWin SMART V2.5

Поделиться
HTML-код
  • Опубликовано: 6 сен 2024
  • Hello RUclipsrs and Programmers,
    Today I have one video for show and share about how to easy to connect PLC S7-200 SMART communication with LAN cable by using Step7 MicroWin SMART V2.5 step by step and easy to understand.
    In this video everyone will understand about how to use and configure software Step7 MicroWin SMART V2.5 to communication between PLC S7-200 SMART with LAN cable.
    If everyone have any questions please kindly drop comment under my videos or contact me by:
    / plc.scada.7564
    Link below is related to PLC programming:
    Easy to connect PLC S7-200 SMART communication with PPI cable by Step7 MicroWin SMART V2.5
    • Easy to connect PLC S7...
    Easy to connect PLC S7-200 CPU 226 CN communication with PPI cable by Step7 MicroWin V4.0 SP9
    • Easy to connect PLC S7...
    Learn SIMATIC Manager Step7 full course start from beginner in 6 hours EP2
    • Learn SIMATIC Manager ...
    Learn SIMATIC Manager Step7 full course start from beginner in 7 hours EP1
    • Learn SIMATIC Manager ...
    Connect PLC S7-200 CPU 226 CN communication with PC Adapter A2 cable by Step7 MicroWin V4.0 SP9
    • Connect PLC S7-200 CPU...
    Connect PLC S7-200 CPU 226 CN communication with PC Adapter MPI cable by Step7 MicroWin V4.0 SP9
    • Connect PLC S7-200 CPU...
    Connect PLC S7-200 CPU 226 CN communication with PC Adapter MPI cable by Step7 MicroWin V4.0 SP9
    • Connect PLC S7-200 CPU...
    WinCC Flexible 2008 SP5 and Simatic Manager software how to create Analog alarms
    • WinCC Flexible 2008 SP...
    How to install driver PC Adapter USB MPI for connect with PLC S7-200 and PLC S7-300
    • Video
    How to install driver PC Adapter USB MPI A2 driver for PLC S7-200, S7-300
    • Video
    PC Adapter A2 driver
    drive.google.c...
    PC Adapter V2.0 driver
    drive.google.c...
    PLC S7-200 Smart EM AR02 connect directly with RTD, PT-100
    • PLC S7-200 Smart EM A...
    How to install software Step7 MicroWin SMART V2.5 on Windows 10 Pro X64 Bit?
    • Video
    Software Step7 MicroWin Smart V2.5
    drive.google.c...
    WinCC Flexible 2008 SP5 and SImatic Manager software how to create discrete alarms or digital alarms
    • WinCC Flexible 2008 SP...
    SIMATIC Manager V5.6 how to use Function FC105 for scaling analog input converter
    • SIMATIC Manager V5.6 h...
    How to install software Step7 MicroWin V4.0 SP9 on VMware Player and Windows 10Pro X64 version 2018
    • Video
    PID control temperature by using Pt-100 with PLC S7-200 Smart CPU SR30 & EM AM03
    • PID control temperatur...
    Pt-100, RTD connect with PLC S7-200 Smart
    • Pt-100, RTD connect wi...
    How to connect Pt-100 and control valve to PLC S7-200 and link to HMI SMART 700 IE V3 (PID Control)
    • How to connect Pt-100 ...
    How to connect Pt-100 and control valve to PLC S7-200 and link to HMI SMART 700 IE V3 part 2
    • How to connect Pt-100 ...
    PLC S7-200 SMART CPU SR30 & EM AM03 Analog scaling full creation step by step part1
    • PLC S7-200 SMART CPU S...
    How to connect Pt-100 and control valve to PLC S7-200 part1
    • How to connect Pt-100 ...
    PLC S7-300 Analog input module connect with Pt-100, RTD and TC(Thermocouple)
    • PLC S7-300 Analog inpu...
    PLC S7-300 connect with temperature sensors RTD, Pt-100
    • PLC S7-300 connect wit...
    Simatic Manager v5.6 and WinCC Flexible 2008 SP5 how to use Function "FC" PID control VFD part 3
    • Simatic Manager v5.6 a...
    Simatic Manager v5.6 and WinCC Flexible 2008 SP5 how to use Function "FC" control VFD part 2
    • Simatic Manager v5.6 a...
    Simatic Manager v5.6 and WinCC Flexible 2008 SP5 how to use Function "FC" ON, OFF control VFD part 1
    • Simatic Manager v5.6 a...
    How to add/configure/test Digital Output module of PLC S7-300 SM322-1HH01-0AA0 by using Simatic Manager V5.6
    • How to add/configure/t...
    How to add/configure/test Digital Input module of PLC S7-300 SM 321-1BH02-0AA0 by using Simatic V5.6
    • How to add/configure/t...
    How to add/configure/test Analog Output module of PLC S7-300 SM 332-5HF00-0AB0 by using Simatic V5.6
    • How to add/configure/t...
    How to add/configure/test analog input module of PLC S7-300 SM 331-7KF02-0AB0 by using Simatic V5.6
    • How to add/configure/t...
    Simatic Manager how to create Function "FC" for Analog Input part2
    • Simatic Manager how to...
    Simatic Manager how to create Function "FC" part1
    • Simatic Manager how to...
    Simatic Manager how to create Function "FC" part2
    • Simatic Manager how to...
    Read data from encoder by using PLC S7-300 CPU314C-2PN/DP part1
    • Read data from encoder...
    Read data from encoder by using PLC S7-300 CPU314C-2PN/DP part2
    • Read data from encoder...
    Thanks you so much for watching my video.
    I'm so sorry if I have mistake in this video.
    Please like share and subscribe my video also to get new notification and new videos.
    Good luck for everyone!
    See you next videos.

Комментарии • 23

  • @henrrycaticuago5092
    @henrrycaticuago5092 2 года назад +2

    Hello friend, do you happen to have a virtual machine to download information about the PLC Smart CPU ST60?

  • @r-v-o-s357
    @r-v-o-s357 3 месяца назад

    Hi friend, i am trying to access our PLC S7-200 CPU ST60 and it was found. The problem is after i press the Upload button, the microwin suddenly closed. It is not the same on your video that the blocks immediately appeared. My question is, does the program still there in the CPU and not corrupted? Thank you

  • @eliekashaka7830
    @eliekashaka7830 2 года назад +1

    Oh okay ! Now it's working ! Thank you sir

  • @ka-eskwelatv6097
    @ka-eskwelatv6097 3 года назад +1

    Thank you very much for your video sir.

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 года назад

      You are very welcome!

    • @ka-eskwelatv6097
      @ka-eskwelatv6097 3 года назад +1

      @@generaltechnologyknowledge5165 Sir what version is yours ? I have 2.02 version I have problem detecting PPI to network interface card and that's cause of not detecting the PLC once I click find. Can you help me.sir

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 года назад +1

      @@ka-eskwelatv6097 Dear sir,
      I used Version 2.5 it can use with all CPUs.

    • @ka-eskwelatv6097
      @ka-eskwelatv6097 3 года назад

      @@generaltechnologyknowledge5165 I use lan cable for.communication much easier. Thank you sir

  • @jayakrishnachowdery4539
    @jayakrishnachowdery4539 2 года назад

    Nice bro pls do video on servo programme with s71500 or 1200

  • @ransagark.c3039
    @ransagark.c3039 3 года назад +1

    Thank you sir

  • @vandeetmehta9658
    @vandeetmehta9658 Год назад

    Can you plz help me, I already did everything step by step as you showed but it still is showing failed to connect to current IP address.Plz Help.

  • @trungthanh6635
    @trungthanh6635 Год назад

    Em cần link mua cáp kết nối giữa PC với S7-200 CPU CR30s ạ

  • @dwinurdianto7298
    @dwinurdianto7298 3 года назад +1

    I have been try connect cpu st40 with my laptop but failed...
    I try ping default ip but it's no reply..
    When I click find cpu, there is no cpu found, can you help me solve it..
    My network port is works when I connect it with another networks, except the plc one

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 года назад

      Dear sir,
      First we need to put the automatic for IP address of your computer.
      Second we need to connect the Lan cable from your Lan port of PC to PLC S7-200 Smart.
      Third we need to turn off windows fire wall: control panel->Windows fire wall->select OFF then click ok.
      Fourth we need to open softwar Simatic Microwin Smart->Communication->Select the coorect your network port type-> Click find CPU-> It will found IP address of PLC and Mac address also.Then you can put the manual IP address of your computer the match with Ip address of your PLC.
      I hope it work.
      Thanks

    • @generaltechnologyknowledge5165
      @generaltechnologyknowledge5165  3 года назад +1

      Anyway I will create a tutorial more and go slowly step by step about how to connect using Lan port between Simatic Microwin Smart with PLC S7-200 Smart for easy to understand.
      Thanks

    • @dwinurdianto7298
      @dwinurdianto7298 3 года назад

      My problem solved after windows 10doing updates

  • @eliekashaka7830
    @eliekashaka7830 2 года назад

    Thank you sir. But I did all these rigth, but it Still saying: Failed to connect to the current IP adress. Check the IP adress, the network connection. What Can I do ?

    • @vandeetmehta9658
      @vandeetmehta9658 Год назад

      Hi,I have the same problem,can you guide me through it?how did you solve it?

  • @ransagark.c3039
    @ransagark.c3039 3 года назад +1

    All plc video upload kro