Hi! First of all thank You for the video. Some days before arrived my HMI panel too. I had a big frustration about my HMI device. I'll tell You what happened. Maybe the story will be useful for the others. I didn't know that the version of HMI is very important thing in this case. My OP320A is an early version (v.6.5) so I can use that version of this program, which especially written for v. 6.5. Finally I found the suitable version and I made a small simple screen arrangement with it. I downloaded the software to the HMI, but after downloading the screen was empty. I couldn"t see any of the downloaded elements on the screen. I didn't know why. In earlier I used an Array SH300 type HMI device, which was very similar to OP320. At SH300 after downloading immediately appeared the designed user screen on the HMI. At OP320 there is different the method. After long suffering I though, lets try to connect HMI to the PLC. The downloaded user screen suddenly appeared. Now I am happy :) Greeting from Johnny
Halló Jonny, nálam sikerült már 3-4 óra múlva mikor a megfelelő programverziót megtaláltam hozzá. Utána akartam egy érintőset és rendeltem egy DOP107BV-t. Itt újra végig kellett küszködnöm mindent, míg végre sikerült. Most azzal kínlódom hogy az így fennmaradt soros portot a PLC-n másra is használhassam a programozáson kívül. Nem nagy sikerrel. Talán segít a tervezője, de nem találom az email-címét sehol. Üdv. stephanabonyi@gmail.com
@@stephanabonyi685 Szia István! Én is próbálom mindig megúszni a kínlódást, de sajnos gyakran beletenyerelek valami hasonlóba. Ezt a DOP 107BV típust nem ismerem még, de a neten találtak alapján úgy látom, hogy ez egy Delta gyártmány. Úgy tudom, hogy van a Delta-nak magyarországi képviselete, talán egy próbát megérne megkérdezni tőlük. Üdv: István
Hello, I have the same plc and hmi but I cannot connect the plc with the hmi, I already did all the steps indicated in your video but it is impossible to connect, I have an fx3u and an op320a. but i tried with a fx1n and if it connect
Hi I have performed step by step all your info works everything is activated the outputs of the plc and the memories. there is no exchange of D parameters from PLC to OP If I change the D parameter on the Op it works, but there is no PLC count. can you help me thank you
@@gerozz1973 i will try this soon. I can download program. View status of M and outputs. Data from plc no problem. But when i enter d values it wont register to plc. I will try using 6.3. If not maybe modbus
I just bought an OP320A, it was made in 2022. I can not for the life of me get it to download to the unit. I've tried 6 different USB->RS232 convertors. Made my own cables. Used the supplied cables. Used versions 6, 8 and 9 of the software and I can't get the thing to download. The unit beeps and says "downloading" and then the software times out. It's very frustrating. Anyone else have this problem?
Pc - hmi 2-3 3-2 5-5 7-7 Cable pin connection. Before download select com port in which usb to rs232 cable connected in hmi software. Use 6.5 version . If not working use 8. Mostly 6.5 will support
Сразу не понял кто наполняет регистр,потом прочитал мануал,что М8013 это генератор на 1Гц) Спасибо,было познавательно!
Interesting. How? I thought you needed to set up D8120, then SET M8196 and RST M8125 as it is written in the manual. Why does it just works?
Very helpful ! Thanks for sharing.
thanks for this video, very informative video,,, i have a question,,, do the set value from HMI retain/save to PLC after power off both PLC and HMI?
Wonderful bro...used for me...
Hi!
First of all thank You for the video. Some days before arrived my HMI panel too.
I had a big frustration about my HMI device. I'll tell You what happened. Maybe the story will be useful for the others.
I didn't know that the version of HMI is very important thing in this case. My OP320A is an early version (v.6.5) so I can use that version of this program, which especially written for v. 6.5.
Finally I found the suitable version and I made a small simple screen arrangement with it. I downloaded the software to the HMI, but after downloading the screen was empty.
I couldn"t see any of the downloaded elements on the screen. I didn't know why. In earlier I used an Array SH300 type HMI device, which was very similar to OP320.
At SH300 after downloading immediately appeared the designed user screen on the HMI. At OP320 there is different the method.
After long suffering I though, lets try to connect HMI to the PLC. The downloaded user screen suddenly appeared.
Now I am happy :)
Greeting from Johnny
Halló Jonny, nálam sikerült már 3-4 óra múlva mikor a megfelelő programverziót megtaláltam hozzá. Utána akartam egy érintőset és rendeltem egy DOP107BV-t. Itt újra végig kellett küszködnöm mindent, míg végre sikerült. Most azzal kínlódom hogy az így fennmaradt soros portot a PLC-n másra is használhassam a programozáson kívül. Nem nagy sikerrel. Talán segít a tervezője, de nem találom az email-címét sehol. Üdv. stephanabonyi@gmail.com
@@stephanabonyi685
Szia István!
Én is próbálom mindig megúszni a kínlódást, de sajnos gyakran beletenyerelek valami hasonlóba.
Ezt a DOP 107BV típust nem ismerem még, de a neten találtak alapján úgy látom, hogy ez egy Delta gyártmány.
Úgy tudom, hogy van a Delta-nak magyarországi képviselete, talán egy próbát megérne megkérdezni tőlük.
Üdv: István
I saw a possible solution in Spanish ruclips.net/video/iv1JBpafh4Y/видео.htmlsi=wMQQkUdCzt31yiYW
Do you have information pin connection
Between plc FX n HMI
nice video
Hello sir, thanks for this tutorial video and its really help. Can you do a tutorial for integrating barcode scanner with Fx3u PLC.
hey hi can you please help me this hmi and plc can run 6 contactor time wise
I need the program example in each 150 mm length servo on for 2 sec off and on for 150mm
Hello sir thank you for the video. How to connect plc op320 hmi and servodriver in jog mode,speed mide .
Hello, I have the same plc and hmi but I cannot connect the plc with the hmi, I already did all the steps indicated in your video but it is impossible to connect, I have an fx3u and an op320a. but i tried with a fx1n and if it connect
Set baud rate as 38400 in hmi software. check cable pin configuration. use straight cable 1 :1 connection
@@automationtraining385 thanks, the problem was the cable.
@@automationtraining385 thanks, the problem was the cable.
@@automationtraining385 Cable is pin to pin please?
Hi I have performed step by step all your info works everything is activated the outputs of the plc and the memories.
there is no exchange of D parameters from PLC to OP
If I change the D parameter on the Op it works, but there is no PLC count. can you help me
thank you
I have this same problem also. What did u do to fix?
@@franzschluter5252 version 6.3 of the programming software of the op panel must be used
@@gerozz1973 i will try this soon. I can download program. View status of M and outputs. Data from plc no problem. But when i enter d values it wont register to plc. I will try using 6.3. If not maybe modbus
Sir can i get usb to serial cable driver because we havr purchased same cable but it can't run on prolific driver
Download driver here.Please subscribe our channel.
drive.google.com/open?id=1iW70wOfEcoWEoqc_Qyvy1hVnOa-RgD6r
Hi. sir I find a lot of software program to download program to HMI.
please give me your program you use it web to download program.
Software name to hmi please..
I just bought an OP320A, it was made in 2022. I can not for the life of me get it to download to the unit. I've tried 6 different USB->RS232 convertors. Made my own cables. Used the supplied cables. Used versions 6, 8 and 9 of the software and I can't get the thing to download. The unit beeps and says "downloading" and then the software times out. It's very frustrating. Anyone else have this problem?
Pc - hmi
2-3
3-2
5-5
7-7
Cable pin connection. Before download select com port in which usb to rs232 cable connected in hmi software. Use 6.5 version . If not working use 8. Mostly 6.5 will support
I saw a possible solution in Spanish ruclips.net/video/iv1JBpafh4Y/видео.htmlsi=wMQQkUdCzt31yiYW
Giod
passwoe
In new plc and hmi there is no password. password is done by user while programing