Double the heat to your room change a single radiator to a double radiator

Поделиться
HTML-код
  • Опубликовано: 20 сен 2024
  • Really cold weather always shows up an under powered single panel radiator. The easiest way to double the heat, is if you buy one the same size, but a double panel convector radiator. The bonus, there is no draining down of the system. Do it yourself, easy tutorial.
    I also now have an Amazon storefront for all plumbing parts. It is www.amazon.co.uk/shop/dereton33

Комментарии • 119

  • @dgallagher7029
    @dgallagher7029 Год назад +8

    This is so helpful. I was quoted £200 to replace a radiator, not including the cost of the radiator itself, by a local handyman. Watching this, I feel it’s actually something that I could do myself. Thank you for this.

    • @dereton33
      @dereton33  Год назад +1

      Excellent!

    • @foppo101
      @foppo101 3 месяца назад

      You mean a local cowboy?

  • @stevelane6637
    @stevelane6637 2 года назад +1

    i think having the wife asking questions makes this video. she asked the same questions i was thinking. nice job.

  • @kape9004
    @kape9004 Год назад +2

    A great job again from you and the missus. Thank you. I have to change a single rad to a double, but have no leeway on the feed and return copper pipes from the floor. I'm going to disconnect the radiator, then turn the valves towards me through 90 degrees, as the new radiator will be twice the depth of the single. Then I'll connect up the valve and rad with 90 degree pipework. Just a suggestion for anyone who has the same problem. Have a happy New Year and all the best for 2023.

    • @dereton33
      @dereton33  Год назад

      Good luck and have a great new year. 👍

    • @valentinefeldbergs5992
      @valentinefeldbergs5992 11 месяцев назад

      I’ve got the same problem. I was thinking the same about turning the valves towards me, but can’t figure out what 90 degree pipe work to get to make it work, are you able to share some link for what part you got? Thank you!

  • @paulb9453
    @paulb9453 3 года назад +1

    love Mo your handy assistant. And thanks to camerawoman for asking the right questions

  • @luigiluigi2098
    @luigiluigi2098 6 лет назад +4

    You make it look so easy. Nice job mate.

  • @ZacandOllie
    @ZacandOllie 6 лет назад +2

    Very timely with the beast from the east blowing in 👍

    • @dereton33
      @dereton33  6 лет назад +1

      Yes we need all the heat we can get Natasha.

  • @lordmellis7135
    @lordmellis7135 6 лет назад +9

    When your wife asks too many questions😂
    Great video... thank you

  • @ratchriat1716
    @ratchriat1716 6 лет назад +2

    loved the way you did your measurement you mad it so mush easy loved the video

  • @krismckay1590
    @krismckay1590 Год назад

    Very comprehensive, thank you.

  • @joeyshore7115
    @joeyshore7115 5 лет назад +3

    so well explained thank you

  • @normanboyes4983
    @normanboyes4983 6 лет назад

    I was relieved to see you turning off that socket!

  • @bazburdett9756
    @bazburdett9756 4 года назад

    Excellent video . . .its a job im about to do in the next few days. Thankyou for the posting

  • @barrygill2213
    @barrygill2213 4 года назад

    Great vid so easy to understand thanks👍👍

  • @corkion
    @corkion Год назад

    brilliant vid i had a plastering job done to my wall behind the rad he took the rad off but bent the pipe foward a good bit when i went to put the rad back on i need to stragent it up but im worried i will crack the pipe coming up from the concreate floor

    • @dereton33
      @dereton33  Год назад

      You will have to take a chance. Bend it slowly bit by bit.

  • @neilsjmcmahon
    @neilsjmcmahon Год назад

    Mo - great little helper

  • @DIVORCEGUY
    @DIVORCEGUY 3 года назад

    Another great video, thanks

  • @benplus2053
    @benplus2053 4 года назад +1

    if these things are filled with water,why isn't there more water coming out of the old radiator?

  • @MaximusJohal
    @MaximusJohal 8 месяцев назад

    I've never put an inhibator in the radiator and i've taken loads of water out of it as i thought it had an air lock!

    • @dereton33
      @dereton33  8 месяцев назад

      May need topping up then.

  • @davidlewis7516
    @davidlewis7516 6 лет назад +1

    Remember, the boiler BTU output is not exceeded by all radiators BTU?

  • @rickycliffe
    @rickycliffe 2 года назад

    Great video 👍

  • @msoutlookenator
    @msoutlookenator 6 лет назад +5

    When you double your output in this manner for the rad being upgraded does your boiler have to work a little harder as a result? I have five seven rads that could potentially be swapped for double panel convection rads but concerned about the boiler strength. At the moment I have a total of ten rads in the system including towel rail and two double rads.

    • @dereton33
      @dereton33  6 лет назад +2

      It has to work a little harder but the trade off is worth it.

    • @msoutlookenator
      @msoutlookenator 6 лет назад +2

      dereton33 My boiler is already struggling with what I have. Doesn't get hardley any heat to the furthest rad (which is a double). Have tried balancing by opening up the lockshield and working my way back closing off the others a quarter turn as I go back towards the boiler but it's only slightly warm at the top. If I isolate it so it's the only rad turned on through the system it heats up.

    • @davidreece1642
      @davidreece1642 2 года назад

      @@msoutlookenator Have you eliminated sludge/corrosion or air; if so you may need a new boiler. I'm not a plumber so that's my uninformed opinion.

  • @rohailali12
    @rohailali12 2 года назад

    Brilliant and very informative videos. Thank you for sharing the knowledge. In my house I have old singe radiators installed but I would like to replace them with double radiators. It's very difficult yo find exact length of the double radiators and I'm worried that the distance from the wall of the double radiator would be off from the existing copper pipe coming out of the fixed floor. I'm thinking may be I can cut the copper pipes above floor level and install plastic straight connecters and then use PEX or plastic flexi piper to connect to the new double radiators. If possible can you please make a video to help with this or provide guidance. Your help is much appreciated. Kind regards

    • @dereton33
      @dereton33  2 года назад

      I will see what jobs are coming up.

    • @muppetman777777777
      @muppetman777777777 Год назад

      ​​@@dereton33yes how come the valve was still the correct distance from the wall for the double? I find the valve is 3 or 4cm from the wall for a single and 7 or 8cm from the wall for a double. Where do you buy double radiators that have the inlets remain 3 or 4cm from the wall?

  • @Jessicaa221
    @Jessicaa221 4 года назад +1

    Double radiators can be very bulky compare to single ones checkout type 21 radiators these are double radiators but in all the sense look like a single radiator

  • @thebanditsix
    @thebanditsix 3 года назад +1

    Why can't the radiator manufacturers place the brackets in the same place, that way can just hang the rad on the existing wall hangers.

    • @dereton33
      @dereton33  3 года назад

      If only life was that easy.

  • @kkkkit
    @kkkkit 2 года назад

    My house was built in the 50’s and my rads are all a panel - just one single panel if you know what I mean. They get roasting down stairs but not upstairs, wondering if they are efficient

    • @dereton33
      @dereton33  2 года назад +1

      They may just need turning on more, or what`s called system balancing, I have videos on it.

  • @davidlewis7516
    @davidlewis7516 6 лет назад +1

    Is it not best to change the olives on the rad tails?

  • @TheHarlemShow01
    @TheHarlemShow01 5 лет назад

    Thanks For The Video 👍

  • @jodonbaker43
    @jodonbaker43 6 лет назад

    Great job more food videos please.

  • @willo219
    @willo219 3 года назад +1

    Hi, thanks for the video which is great by the way, just one question -- when you have every connected back up with the new radiator do you open the lockshield and then bleed the radiator as in the video? or do you open the trv, then the lockshield then bleed it?

    • @dereton33
      @dereton33  3 года назад +1

      It does not matter, I have always opened the lockshield first, out of habit.

    • @willo219
      @willo219 3 года назад +1

      @@dereton33 thanks for the reply, do I need to lockshield and TRV open to bleed it? I just didn't want to introduce air into the rest of the system

  • @HazelAndrewsAcupuncture
    @HazelAndrewsAcupuncture 6 лет назад

    lovely clear video. I have two rads I need to replace so I have no excuse now. Just a quick question - I have a open vented system is there any benefit in topping the rad up with water as well as inhibitor.. or should I just let the F and E tank do it's job ( not sure how much sludge is in it! )

    • @dereton33
      @dereton33  6 лет назад

      No just let the F and E tank do it`s job.

  • @rayc1503
    @rayc1503 6 лет назад

    Lovely an Ideal boiler, I call it, A pain in the A**e. Now you've added that rad it's going to bring on a host of new problems. You should've changed the boiler 😂, great vid ✌

  • @David2122006
    @David2122006 Год назад

    What do you do when there is absolutely no play in the pipe, and the rad pipework is plastered over in a blockwork wall, and only extends as far out from the wall as the radiator valve, and all that is left sticking out is 30mm of copper pipe with a soldered elbow, with another short bit of copper pipe up into the radiator valve.........?

    • @dereton33
      @dereton33  Год назад

      Drain the system and cut the pipe and extend to the new wider measurement.

    • @David2122006
      @David2122006 Год назад

      @@dereton33 Thank you for your quick reply, but there is not enough pipe sticking out of the wall to get a straight connector on, and then solder on an elbow or bend into the valve.

  • @leejones4727
    @leejones4727 2 года назад

    Great informative video. Just one thing I'm wondering, if the pipes are coming up from a concrete floor does this mean some new pipework will be needed or would there still be a little play in them?

    • @dereton33
      @dereton33  2 года назад +1

      There should be a little play in them, especially if they are long stems.

    • @leejones4727
      @leejones4727 2 года назад

      Thank you for the quick reply.

  • @stockguy2860
    @stockguy2860 Год назад

    0:24 If I get same size & brand radiator will I need to adjust the brackets? Thank you.

    • @dereton33
      @dereton33  Год назад

      No it should be the same.

    • @stockguy2860
      @stockguy2860 Год назад

      @@dereton33 Thank you. Learned a lot from you. Love watching your videos.

  • @9094328
    @9094328 4 года назад

    Did you put the Teflon tape on backwards? You wrapped it Lefty Loosely, but the fitting went in Righty Tighty! I'm actually being serious. Does this matter?

    • @lewislarkin5630
      @lewislarkin5630 4 года назад

      JASON BORDEN yes against the turn so the tape doesn’t unravel

  • @kamikas3e
    @kamikas3e 4 года назад

    Hi @dereton33, I have been watching your videos and they have helped me a lot I got to say. :) this one specially. I wanted to ask though. I want to change my single to a double/triple column one, but I am not sure of the wall will hold these? I see that you use the "standard type 22" but would you recommend a column one?

    • @dereton33
      @dereton33  4 года назад +1

      Column ones are quite ok.

  • @stuarthay1
    @stuarthay1 4 года назад

    Nice scooter T-shirt Al.Quadrophinia fan are you? 👍

  • @PensiveCashew
    @PensiveCashew 4 года назад +1

    Thanks for the tutorial. I've taken off my old rad and got the new one lined up (upstairs, opposite end of the house to the boiler). I failed to note down the number of turns on the lockshield valve (been redecorating for a couple of weeks). Should I just reopen it a couple of turns and hope for the best? If it knocks out the balance I'd that something I can sort later on?

    • @dereton33
      @dereton33  4 года назад

      Yes a couple of turns is a safe bet. Sort out any balancing after that.

    • @PensiveCashew
      @PensiveCashew 4 года назад +1

      @@dereton33 thanks for getting back to me. Your videos gave me the confidence to change my first radiator and it has been a great success. Cheers

    • @keagandylan5237
      @keagandylan5237 3 года назад

      You prolly dont give a damn but does anyone know a way to log back into an Instagram account??
      I somehow lost the password. I appreciate any tricks you can give me.

    • @pedrojames6149
      @pedrojames6149 3 года назад

      @Keagan Dylan Instablaster :)

    • @keagandylan5237
      @keagandylan5237 3 года назад

      @Pedro James I really appreciate your reply. I found the site thru google and Im in the hacking process atm.
      Takes a while so I will get back to you later with my results.

  • @markalmeida3816
    @markalmeida3816 4 года назад

    Thank you!!!

  • @HKey_Root
    @HKey_Root 4 года назад

    Great vids. Thanks. When looking for a new radiator where do you measure from and to, to make sure the replacement isn't too long/short please? What are the dimensions quoted online?

    • @dereton33
      @dereton33  4 года назад +3

      I have another video on how to measure for the correct size.

    • @HKey_Root
      @HKey_Root 4 года назад

      @@dereton33 Found it. Cheers.

  • @moulelmarteau926
    @moulelmarteau926 6 лет назад

    hello that was a real plumber job ,iam from algeria and i do work as a plumber since 2006 and soon iam coming to uk ,what do i need to be a certified plumber ?and is it necessary to learn how to write perfect english for the job ? although i can talk and communicate in english language quite good

    • @dereton33
      @dereton33  6 лет назад

      You will need to be registered. Guess they might set you a test. Not to sure on this one.

    • @rayc1503
      @rayc1503 6 лет назад

      Algerino Vero If you want to be a general plumber. You can learn on the job. If you want to do any gas related work. You'll have to do your ACS city and guilds to become Gas Safe Registered along with putting a portfolio together. You'll have to do this with an accredited Gas Safe Registered heating & plumbing engineer.

  • @davehunter6920
    @davehunter6920 3 года назад

    good vid..but find it much easier to just line rad agin the wall and place a mark where the bracket edge will be then use a level to draw a straight edge.....next measure floor to valve centre / bottom edge of bracket centre to bottom edge of radiator / add these two measurements and then subtract distance of rad edge to valve centre/ get your calculation and mark position of bracket on wall/ easy peasy lemon squeezy

  • @lilibethrolls1691
    @lilibethrolls1691 3 года назад

    Hi, just had a radiator fitted they told me it was a double but it looks more like a single can you help me is there a way of telling?
    Thank you.

    • @dereton33
      @dereton33  3 года назад

      A double has two heat panels, one in front and one at the back.

  • @lusilk7954
    @lusilk7954 4 года назад

    top marks bro

  • @Then.72
    @Then.72 2 года назад

    Make sure your boiler can do it

    • @dereton33
      @dereton33  2 года назад

      Most are oversized.

    • @Then.72
      @Then.72 2 года назад

      @@dereton33 agree but it’s worth checking

  • @richardfawcett1987
    @richardfawcett1987 6 лет назад +1

    my rads are very old and cant find one to fit

    • @dereton33
      @dereton33  6 лет назад +1

      You can get valve extensions to make up any short fall in length.

  • @mknight7209
    @mknight7209 5 лет назад +1

    What's the best boiler for these double radiator?

  • @lusilk7954
    @lusilk7954 4 года назад

    top marks

  • @qkayani
    @qkayani 3 года назад

    I thought there would be more water in the radiators

    • @dereton33
      @dereton33  3 года назад

      Never as much as you think.

  • @indicatoker420
    @indicatoker420 4 года назад

    Some important things wasn't covered. Types of walls and the fixings for them. Plasterboard vs solid wall. If that was on plaster it would eventually fall off with plugs or come loose at least. Or not withstand too much force put on the radiator.

    • @dereton33
      @dereton33  4 года назад +3

      That would have been common sense.

  • @neojted
    @neojted 4 года назад

    Why does everyone giving plumbing advice use mole wrenches and pliers rather than the correct sized spanner?

    • @dereton33
      @dereton33  4 года назад +2

      Would need to many spanners to carry around.

  • @iamkjb1
    @iamkjb1 Год назад

    Here in 2022 I know people who are swapping double panel rads for single to reduce costs, ironic.