Vintage Ferroli and Daikin air conditioners

Поделиться
HTML-код
  • Опубликовано: 5 фев 2025
  • So, after a long wait, here's a new video! These air conditioners are at my friend's house.
    Daikin:
    model: FTY35GV1B/ REY35GV1B (1999, R22)
    Ferroli (Hisense):
    models: indoor is unknown, outdoor: U. E. DS 7+7 PC7 (2004, R407C).
    Both air conditioners work good, but daikin has a broken swing and ferroli is rattly.
    Hope you liked, if yes subscribe for more content. Leave a comment if you want

Комментарии • 31

  • @Unvalid_Marc
    @Unvalid_Marc Месяц назад +3

    I never seen this Ferroli indoor and remote until i watched fully the video

    • @endermat_
      @endermat_  Месяц назад +1

      These are pretty uncommon models

    • @Unvalid_Marc
      @Unvalid_Marc Месяц назад +1

      @endermat_ ok but i saw the other Ferroli outdoor units in Naples when i was in my parents' car

  • @AirConditioner4ever
    @AirConditioner4ever Месяц назад +3

    Slay ❤

    • @endermat_
      @endermat_  Месяц назад +2

      I love them too 🥰

  • @Daris-r2i
    @Daris-r2i Месяц назад +1

    the Ferroli remote reminded me of the Siemens Xelibri 4!

    • @endermat_
      @endermat_  Месяц назад

      It might be an Hisense oem too

    • @Daris-r2i
      @Daris-r2i Месяц назад

      @@endermat_ it is a phone

    • @endermat_
      @endermat_  Месяц назад

      @@Daris-r2i ah 😂 i never heard jt

  • @brothermyboy8226
    @brothermyboy8226 15 дней назад +1

    Ferroli's indoor fan motor capacitor might've gone bad, which explains the weak airflow.

    • @endermat_
      @endermat_  15 дней назад

      That’s provably the reason

    • @brothermyboy8226
      @brothermyboy8226 15 дней назад +1

      @endermat_ replacing it was cheap and easy, it doesn't matter what brand it was, as long as it was the right size.

    • @endermat_
      @endermat_  15 дней назад

      @ well, I told this to the owners, they said “it’s fine like this” 🙁

    • @brothermyboy8226
      @brothermyboy8226 15 дней назад +1

      @endermat_ well despite this, i still recommend them to call an HVAC tech to replace the capacitor if they want it to blow normally.

    • @endermat_
      @endermat_  15 дней назад +1

      @ yes this is what I would do

  • @Daris-r2i
    @Daris-r2i Месяц назад +1

    That Daikin startup sound lasted until the FTC50/60NV14 in Indonesia

    • @endermat_
      @endermat_  Месяц назад

      They are newer than this…probably same compressor…?

    • @Daris-r2i
      @Daris-r2i Месяц назад +1

      @@endermat_FTC uses Rechi Compressor

    • @endermat_
      @endermat_  Месяц назад

      @@Daris-r2i I’m not sure about this one..i never opened the condenser

  • @Westmimo14
    @Westmimo14 9 дней назад

    On/offs Daikin are sooo rare

    • @endermat_
      @endermat_  9 дней назад

      Not that much

    • @Westmimo14
      @Westmimo14 8 дней назад +1

      @endermat_ emmm.... Most of the time inverters

  • @aerinsha
    @aerinsha Месяц назад +1

    i found that vintage daikin at the hospital, but the red indicator is turn on

    • @endermat_
      @endermat_  Месяц назад

      The red indicator means that filter needs to be cleaned. On this unit I had to reset it before the video

  • @Tom7AirConditioners
    @Tom7AirConditioners Месяц назад +1

    My Midea Ac Have The Same Problem Of Broken Swing

    • @endermat_
      @endermat_  Месяц назад

      Yes it’s annyoing as you can’t adjust it

  • @TrigintillionFan
    @TrigintillionFan Месяц назад +1

    Conventional Inverter Daikin

    • @endermat_
      @endermat_  Месяц назад

      This is not an inverter, but there is its inverter version, it’s rare, but there is

    • @AirConditioner4ever
      @AirConditioner4ever Месяц назад +1

      ​@@endermat_ there's even siesta version of this!

    • @endermat_
      @endermat_  Месяц назад

      @ nice! Merry Christmas to you

    • @AirConditioner4ever
      @AirConditioner4ever Месяц назад +1

      Thx