  • DIC is also termed as Differential interference contrast Microscope. This microscopy technique uses the polarizer and a special type of prism to split light into two rays (or two waves) known as the e ray and the o ray. Both the rays are separated by a small distance known as the shear distance. There is also a phase difference between both the rays. Both the rays passes through the specimen and further hits the second prism which combines them into a single ray. finally the image observed has one bright region and other dark region. the physics involved in DIC microscope has been discussed in detail. Finally we also compare DIC and phase contrast microscope as both of them can be confusing.

Комментарии • 22

  • @asphyx9
    @asphyx9 Год назад +4

    Thank you - one of the best explanations I have seen on DIC

  • @yixuanshen8366
    @yixuanshen8366 2 года назад +3

    Dude, you are saving my life

  • @tarunkumarpalli7580
    @tarunkumarpalli7580 2 года назад +2

    Wow dude, its so, clear to understand

  • @nourelhoudabenyahia257
    @nourelhoudabenyahia257 Год назад +2

    Amazing explanation!

  • @phamdung3884
    @phamdung3884 Год назад

    This really is a simple explanation. Thank you so much! ^^

  • @potharlaanil5621
    @potharlaanil5621 2 года назад +2

    I salute for your explanation..

  • @peterallen8573
    @peterallen8573 7 месяцев назад

    Good explanation.Thank you.

  • @moneeralhalabi1272
    @moneeralhalabi1272 Год назад

    Great work

  • @keshaxLOVEx
    @keshaxLOVEx Год назад +1

    very useful thank you

  • @anindita6913
    @anindita6913 2 года назад

    Excellent

  • @shivanin8708
    @shivanin8708 2 года назад

    Thank you so much!!

  • @christeenamathew8606
    @christeenamathew8606 Год назад +1

    crystal clear 🤟

  • @CHAMPIONSBio
    @CHAMPIONSBio 2 года назад

    Thanks a lot bro .....

  • @nihalhathaway4089
    @nihalhathaway4089 Год назад

    thank you very much! Isn't the condenser after the polarizer, between prism and stage?

  • @pak2966
    @pak2966 4 месяца назад

    Are the two Nomarski prisms exactly the same (just inversed) or do they differ?

  • @gregvisioninfosoft
    @gregvisioninfosoft 6 месяцев назад

    Does anyone here have broad experience using DIC? I was hoping I could ask a question. I am trying to understand this in a general manner. From this video at 0:06 timestamp, we see that two (I assume 'matched') 'DIC Nomarski Prisms' are required. One below the sample, and one above. Apparently there is no concept of a single one-size-fits-all 'DIC Nomarski Prism. As when I look at actual part numbers, for example in the Olympus microscope line, there are several of these: U-DIC-10, U-DIC-20, U-DIC-40, U-DIC60, and U-DIC100. What I notice in the differing catalog numbers is what appears to be the 'Magnification' is different. This implies the DIC Nomarski Prism is somehow 'optimized' to a given magnification. My first question is - what actually causes these DIC Nomarski Prisms to be different in their manufactured characteristics? In other words, if one were to hold both a U-DIC10 and compare it to a U-DIC20 - how exactly would they be different?

  • @user-yj6ye4zk8v
    @user-yj6ye4zk8v Год назад

    5:34

  • @JongcheolLee
    @JongcheolLee 2 года назад

    Wow best video ever explaining DIC

  • @mototajo8911
    @mototajo8911 2 года назад

    Thanda

  • @user-yj6ye4zk8v
    @user-yj6ye4zk8v Год назад

    6:16