Predictive Maintenance Best Practices Presented by Fluke
HTML-код
- Опубликовано: 2 окт 2024
- Join us for this webinar about predictive maintenance best practices. Implementing proactive testing will help reduce downtime and minimize lost revenue. We will be discussing the best maintenance practices, the most important trends, the leading technologies to start a predictive maintenance program with and how much predictive maintenance can save you.
To find out more about Transcat’s product and service offerings, please contact us at 800.828.1470 or visit our website: www.transcat.com
To view all Fluke products, visit this link: www.transcat.c...
INTRODUCTION
0:00 Welcome to The Fluke Predictive Maintenance Webinar
1:29 Predictive Maintenance Best Practices
2:14 Leading Test Technologies to start a Predictive Maintenance prgram
2:39 Todayʻs Agenda
MAINTENANCE
3:16 Maintenance Practices: Which is Best?
3:20 Before we begin
4:10 Case Study
5:30 Reactive Maintenance Practices
6:22 Reactive Maintenance Practices
7:01 Mean Time to Failure (MTTF)
7:35 Predictive Maintenance (PdM) Practices
8:18 Spectrum of Maintenance Practices
8:57 Which Practice is Best?
9:24 Why use a blended approach?
9:51 Reliability Centered: “Asset Uptime based”
THEMAL IMAGING
10:53 Next Up: Thermal Imaging
10:55 What is infrared?
11:26 How can infrared help me?
12:06 Understanding modes of heat transfer
12:26 Thermal imaging considerations
12:43 Thermal imaging considerations (contʻd)
13:25 Thermal imaging applications
13:28 Causes of electrical hot spots NFPA 70B v2023 - requires thermal imaging of panels in buildings with a certain amount of people
14:37 Thermal imaging example images
15:06 Inspection Frequency
15:45 Causes of mechanical hot spots
16:31 Themal imaging example images
17:17 Causes of process hot spots
18:00 Themal imaging example images
18:22 Causes of building diagnostic hot spots
19:31 Themal imaging example images
19:55 How is the Image Created? Thousands of IR Temperature Measurments
20:47 Spot Size & Resolution
21:47 Heat Capacity
21:55 What is an IR Window?
22:33 Easy to Use Transmission correction
ACOUSTIC IMAGING
23:14 Ultrasonic Leak Detection - ii900/ ii910 Air/Gas Leak Detection in Fanufactureing Facilites
23:42 Background Facts (Compressed Air Systems)
25:02 Where compressed air and gas is used
25:32 Value of Leak Detection
26:19 What is Acoustic Imaging?
26:25 Acoustic Imaging basics
26:49 How the Sound Map is created
26:59 Time savings
VIBRATION TESTER
28:33 Next Up: Vibration
28:37 What is mechanical vibration?
29:25 Early Indicators of Machine Health
31:24 What probelsm does vibration cause?
31:43 Four common causes of vibration
32:28 Souces of bearing failure - Bearing Failure
32:54 Types of misalignment
33:21 Sources of misalignment
33:34 Sources of unbalance
33:48 Two types of looseness
34:00 Benefits of vibration testing
34:11 How does vibration testing work?
34:52 History of vibration testing
34:58 Fluke 810 Vibration Tester
35:08 Fluke makes vibration testing easier (Aquires Azima DLI in 2023)
35:40 How does Fluke 810 work?
35:52 Vibration testing in three simple steps (Self guided tool)
36:07 Sample of machine setup fields
36:41 Mounting Options
37:12 Understanding the diagnosis
38:11 810 Vibration Tester Features
38:20 Viewer PC Software
38:36 VIewer PC screen shot
39:05 Machine Setup
39:14 Diagnosis Details - Spectra
39:27 Everything you need - out of the box
39:31 Fluke 810 Pays for Itself…And Then Some
POWER QUALITY ANALYZER
40:11 Next Up: Power Quality
40:20 Engergy Logging: Why is my Energy bill so high and where is theis power being wasted?
40:22 Beer Power Analogy and the Power Triangle
41:03 Quantity: Power, kW
41:42 Quantity: Demand, kVA
41:55 Quantity: Power Factor, PF
42:20 Power, Demand or Consumption?
42:29 Peak Demand - the most expensive power
42:51 Quantity: The Utility Bill
43:03 NFPA 70E NEC Code 220 (Load change requries 30 days, must use a Power Analyzer)
43:18 Industrial Facilities Energy Efficiency
43:52 How Should You Measure Engergy Consumption?
44:15 Common Causes of Energy Waste
45:05 Power Quality Components: Why is equipment not working in my facility?
45:07 Quality: Harmonics (quality of voltage, non-linear loads, switchmode power supply in PC, displays that distord waveforms)
45:57 Quality: Dips & Swells
47:22 Quality: Transients
47:49 Quality: Transients sampling
48:14 Unbalance
49:00 Quality: Flicker
49:40 Causes of Poor Power Quality
50:07 History of Power Quality (IEEE519, EN50160)
50:41 Power Quality Applications
51:17 Range of Power Quality Tools
CONCLUSION
51:25 Next Up: Conclusion - ROI & Savings
51:31 Benefits of functioning program
52:24 Seminar Summary
53:23 Thank you for your time today! Questions
Is battery maintenance for UPS part of predictive maintenance with Fluke BT521 Battery Analyzer?