Nice concept but You can discuss some more issues related ESP and HVTX Transformer like Under voltage tripping,Ash level high Tripping,Transformer Heating tripping,Oil heating Tripping so that viewers can understand some more criticalities and don't forget the charge ratio concept.
Bhai baaki to nahi pata...lekin aapka explanation ka trika kaafi se kafi behtar hai....Keep it up.... Animation k through kisi bhi chiz ko smjhna kaafi had TK easy ho jata h
Sir namaskar, aapne achha se concept clear kiya, but sir aap ESP me low & high resistivity, air flow, migration air flow ke bare me deaply video banaye, dhanyavaad
Sir , Namaskaar . No Videos of yours over a long period as of now . By the way , Would you mind taking up "Concept of Restriking & Recovery Voltages along with Breaking & Making Currents of Circuit Breaker" . I hope that you will not of course disappoint your channel's early subscribers like me .
I have doubt about esp. as u know there is a Parameter setting called Charge Ratio in ESP controller . And as per manuals we kept this setting in increasing order starting from 1st field to last field ex: 1 field 1:11 then 2nd field 1:21 then 3rd 1:31 so on . Why we kept setting like this only. What will happen if we set all the field charge ratio setting same like 1:11 or 1:21 .
Fluctuations in KV is normal phenomenon. Its because of voltage build up process & then spark takes place. But fluctuations should not be out of limit.
If ac is applied, electrostatic force on charged dust particles will not be unidirectional. Force will change its direction with time... so just think: then how the dust particles will be collected at collecting plate.
Sir i think collectiong plate positive dc supply ko connected hota h...grounded nahi hota. Plz correct me if i am wrong... If dust particles near earthed collecting plate. Then which force attracts them towards collecting plate...???? Plz reply
No brother, its not like that. Positive polarity of rectifier is grounded that is connected to collecting plate. Bye the way, I really appreciate your way of thinking. Negatively charged particles are attracted towards the grounded plate due to potential difference.
Nice concept but You can discuss some more issues related ESP and HVTX Transformer like Under voltage tripping,Ash level high Tripping,Transformer Heating tripping,Oil heating Tripping so that viewers can understand some more criticalities and don't forget the charge ratio concept.
Bhai baaki to nahi pata...lekin aapka explanation ka trika kaafi se kafi behtar hai....Keep it up.... Animation k through kisi bhi chiz ko smjhna kaafi had TK easy ho jata h
The best video ever I get related to ESP. appreciate your effort
Thank you so much...
sir, why ESP field charged negativity.please clear the concept about that.
Please upload continue videos about power plant (Electrical related)...
The way you explain is very much Interesting 👌 . A lay person can also Abel to understand about esp by this video. 👌
So nice of you. Thanks 😊
Very nice explain and very informative video's keep it.
Thank you very much
Most welcome
It's a Best concept for me, thank you sir
Most welcome
Sir namaskar, aapne achha se concept clear kiya, but sir aap ESP me low & high resistivity, air flow, migration air flow ke bare me deaply video banaye, dhanyavaad
Very great explanation in every topic. Thank you somuch. May i know your good name?
Please make a video on Generator Cooling system, Hydrogen and Water cooling. How it work . In details…
Good information ji sir tq so much for giving this information
Great explanation sir
Very very nicely explained
Thanks
Ek video me pura ESP ka electrical, mechanical & C&I concept clear ho aisa video banane ka kast kre❤❤❤
210 MW unit have 28 fields and every field have separate Emitting motor & collecting motor
you are absolutely correct. Relatively modern plants of 210 MW uses 28 fields also
Nice explain sir
Sir , Namaskaar . No Videos of yours over a long period as of now . By the way , Would you mind taking up "Concept of Restriking & Recovery Voltages along with Breaking & Making Currents of Circuit Breaker" .
I hope that you will not of course disappoint your channel's early subscribers like me .
Hi, Priyaranjan ji. I always enjoyed our technical discussion on this platform.
I will try to pick up this topic in future.
Excellent explanation.. Nice visuals
Glad you think so!
Nice video and concept explanation this video is make on PPT or other if possible give ans
very good explanation
Thanks
Sir my question is,why positive is grounded
And emeting is cannecting of negetive
Best Explanation ❤
Glad you think so!
Excellent video keep the same tempo
I have doubt about esp. as u know there is a Parameter setting called Charge Ratio in ESP controller . And as per manuals we kept this setting in increasing order starting from 1st field to last field ex: 1 field 1:11 then 2nd field 1:21 then 3rd 1:31 so on . Why we kept setting like this only. What will happen if we set all the field charge ratio setting same like 1:11 or 1:21 .
will be answered in next video
Great explain
Thank you sir
Free electon
Negative electrode se produce hote hai kya .toh un pr negative charge hoga. Negative charge paticle will attract to grounded plate.
Sir kya he padhate ho❤
Excellent
Thanks
Thanks fo information
EXCELLENT JI🙏🙏
So nice of you
Excellent video👍
Sir why there is KV fluctiation and what steps do we need to stabilisie KV while charging ESP
Fluctuations in KV is normal phenomenon. Its because of voltage build up process & then spark takes place.
But fluctuations should not be out of limit.
How to calculate ESP field and why DC supply use in Esp field?
nice video sir
Friend, why does the particle go into hopper only after humming, ID fan can pull it.
Very nice
Thanks
Did esp transformer earthing and esp plates earthing connected with eachother or not !
both are connected with common earthing mat
Over fluxing kya hai please explain
Nice sir....
Thanks
Nice
How to decide or know the capacity of e.s.p.?
Sir exam mein ye question aayega to isme diagram bhi banana pdega kya
Please explain pass A B C D in brief
Esp ko dc supply kyo diya jata hi
If ac is applied, electrostatic force on charged dust particles will not be unidirectional. Force will change its direction with time... so just think: then how the dust particles will be collected at collecting plate.
As AC is sinusoidal and DC is Constant. To charge a resistive or conductive dust We need constant electric force .
Good job sir.
Keep it up..❤️
Thanks a lot
Hopper se dust ko kese nikala jata hai
There are two modes. By using water or compressed air
My bangladesh sa bol raha ha. Mara ak electrostatic precipitator bohut zorori ha. Kis tarah milaga?
Why low RPM motor use in ESP
bcz of requirement of high torque & low speed requirement
Collecting plate kaha se attached hai?
Negetive supply emitor ko kyu Diya jata hai isko bataye kha milega link video dekhne k liye
What is field in esp
Sir i think collectiong plate positive dc supply ko connected hota h...grounded nahi hota. Plz correct me if i am wrong...
If dust particles near earthed collecting plate. Then which force attracts them towards collecting plate...????
Plz reply
No brother, its not like that. Positive polarity of rectifier is grounded that is connected to collecting plate.
Bye the way, I really appreciate your way of thinking.
Negatively charged particles are attracted towards the grounded plate due to potential difference.
@@ElectricalTalks but sir if positive polarity earth karoge to waha voltage zero hoga na.???
Kyunki earth ka potential to zero hota h..
Corona discharge kya h sir
Sir why did you stop for past 1 month
Sir ji good bye kyo bol rhe ho😂😂
ha ha 🤣🤣
Kabi negative electod positive bana rhe ho kabi negative
Or positive particles ko positive electrode se attract krwa rhe ho ...ajeeb cheeze kr rhe ho
Best🫂
Kannada dalli helu
Excellent