Hi, Today have one customer, compressor model MUY-GE13VA. The LEV give different reading R-BR:0 R-BL:0 R-OR:49ohm resistor R-Y:0 R-W:49ohm resistor BR-Y:49ohm resistor BL-Y:100ohm resistor Is this LEV spoil because i dont have service manual for this outdoor unit Thank you
Sorry sir aap ke Jo video banaa rahe ho jiske bare mein aap batate ho vah video to chhoti Ho jaati aapki photo badi dikhti chhoti video mein dikhai bhi nahin deta please video ka size full Karen aur aap video mein voice joint kare please aapse request hai 🙏 aur aapke dwara banai gai video se hamen kuchh Na kuchh sikhane Ko milta hai thank you. 🙏
English please. I have an Inverter Refrigerator GE and It has an expansion valve (Saginomiya 5 pins) and I´d appreciate explanation of how to make a proper diagnostic of this part.
If you have 5 pins then you have 4 positive wire for four coils and 1 common negative for 4 coils. They are two procedure to check for EXV . One is mechanical stucked up in stem of exv ,which you can check by putting the system in fan mode and manually flushing th refrigerant or nitrogen to liquid line if the gas comes through suction line then the exv is stucked , because exv should get closed in fan mode and shud not allow refrigerant to pass . And the other is electronic side . Use multimeter in resistance mode and check the resistance between common and coils , u shud not get resistance between 2 coils positive side.
Ada yg punya pengalaman serupa seperti ac saya sidikinftkq20smv4 Punya saya yg berembun cuma pipa kecilnya saja, di evap indoor cuma dingin yg bagian saluran masuk pipa kecil saja (di sentuh tangan) palingan setengah tapak tangan aja bagian permukaan indoor evavoratornya, tapi pagi ini tetiba normal sendiri,dingin merata di indoor evavoratornya, dan di pipa besar outdoor juga sudah berembun. fix bukan freon bocor, tapi apanya ya, kambuhan soalnya.. Tidak ada kode error apapun, sudah saya lihat EEV nya bersih dari karat.
Hi,
Today have one customer, compressor model MUY-GE13VA. The LEV give different reading
R-BR:0
R-BL:0
R-OR:49ohm resistor
R-Y:0
R-W:49ohm resistor
BR-Y:49ohm resistor
BL-Y:100ohm resistor
Is this LEV spoil because i dont have service manual for this outdoor unit
Thank you
Can you test the expansion valve resistance without removing it from ODU. Checking resistance using Multi meter....
Do all inverter ac with r410 contain this valve?
Sir Itachi 5 star outdoor ki cancer designing ki pic mil jayegi expensive wall laga hua hai
Gorkhapur kis jagah milenge
Thanks
Nice video
Good explain
Sorry sir aap ke Jo video banaa rahe ho jiske bare mein aap batate ho vah video to chhoti Ho jaati aapki photo badi dikhti chhoti video mein dikhai bhi nahin deta please video ka size full Karen aur aap video mein voice joint kare please aapse request hai 🙏 aur aapke dwara banai gai video se hamen kuchh Na kuchh sikhane Ko milta hai thank you. 🙏
Sir expansion valve khrab hone par compressor ka pressur ek dum low ho sakta hai kya
गेरखपुर से मै भी हू भाइ और एसी का ही काम भी करता हू आप जो काम रहे है बहुत अच्छा हा
Thanks you sir
Sar mai bhi deoria se hu
Sir sabka coyal sem sem hota hai kya
Nice g
Sir samsung inverter ac mai E422 error code batla raha hai. Gas v oo hai ok service valves v theek se open kardiya
Kya solutions nikla iska apka bhai ho gya thik ya nahi
sir gorkhpur se mai bhi ap kaha se ho
English please. I have an Inverter Refrigerator GE and It has an expansion valve (Saginomiya 5 pins) and I´d appreciate explanation of how to make a proper diagnostic of this part.
If you have 5 pins then you have 4 positive wire for four coils and 1 common negative for 4 coils.
They are two procedure to check for EXV .
One is mechanical stucked up in stem of exv ,which you can check by putting the system in fan mode and manually flushing th refrigerant or nitrogen to liquid line if the gas comes through suction line then the exv is stucked , because exv should get closed in fan mode and shud not allow refrigerant to pass .
And the other is electronic side . Use multimeter in resistance mode and check the resistance between common and coils , u shud not get resistance between 2 coils positive side.
Ese baipass karne ka upaye bataye pipe line dairect kar de to
Vrf system h baar baar compressor kharab ho rha h q sir
सर इन्वेटर ac में एक्सपेंसिव वाल्व के वोल्टेज कैसे चेक करे
Ada yg punya pengalaman serupa seperti ac saya sidikinftkq20smv4
Punya saya yg berembun cuma pipa kecilnya saja, di evap indoor cuma dingin yg bagian saluran masuk pipa kecil saja (di sentuh tangan) palingan setengah tapak tangan aja bagian permukaan indoor evavoratornya, tapi pagi ini tetiba normal sendiri,dingin merata di indoor evavoratornya, dan di pipa besar outdoor juga sudah berembun. fix bukan freon bocor, tapi apanya ya, kambuhan soalnya..
Tidak ada kode error apapun, sudah saya lihat EEV nya bersih dari karat.
place .. Gas chage inverter Ac,, give me video, I,am form Bangladesh ,, place boss
Sir aap na jobhi veido m kaha vo samhaj m too aaya leakin aap ko prakyekly zada dikhlana chahey tha
Agar 1indoor fail hai to by pass kaise karana
Videolarına Türkçe alt yazı ekleyebilirmisin
İnverter klima soğutmuyorsa Elektronik genleşme valfi arızalı mı nasıl çözülür diyor
Bhai practicallu chahiye
Title and text is in English. Rest is not? Why waste people's time?
🙏
Sir apna number dijiye kuch puchna hai
Thanks sir ji