GVI testing

Поделиться
HTML-код
  • Опубликовано: 23 окт 2024

Комментарии • 6

  • @mayrabrocel2745
    @mayrabrocel2745 Год назад

    Hi, Please, What is distance that should be between the digital flow meter and the isolation valve?

    • @globalvisioninc7943
      @globalvisioninc7943  11 месяцев назад

      Hello, this should be a minimum of 5 pipe diameters before the flow meter and 2 pipe diameters after. This is free of any bends or valves, only straight pipe. Please email info@gviflow.com for more information.

  • @josecarlosmartins7040
    @josecarlosmartins7040 6 месяцев назад

    I would you like to learne me how calibration this meter? Please

  • @trianggaindralukmana2184
    @trianggaindralukmana2184 7 лет назад +1

    can you give us clue why the needle in our test with similiar product, is shake around and couldnt steady like videos? maksimum range the scale is 3000 gpm and at around 1500 gpm and 2250 gpm, the needle shaking and unsteady

    • @globalvisioninc7943
      @globalvisioninc7943  7 лет назад

      Hello, and thank you for your comment. This video is of the new patented GVI venturi. I assume you have an older model. There can by many causes for fluctuations as you describe. Perhaps you can send an email to our team at info@gviflow.com and we can work with you for a resolution. Thank you again. GVI team.

    • @benoregan4623
      @benoregan4623 3 года назад +1

      It's your test setup. You need a throttling valve downstream of the flow meter to provide back pressure or else the needle will jump around like crazy.