I love your video but I have a question please. Out of the first 4 program, which one will I use and get to program 28 to parallel Felicity 10kva inverter
Please can you help me out. I am interested in knowing the batteries being charged at 90Amps. I have always known battery charing current based on recommendation not to exceed 10 - 30% of its size. My ask is about 2:49 actually. I like to take some learnings... or is the setting for somethng different from the normal charging current we typically have on the inverter it self?
hello, what would you recomend as my bulk voltage setting on my inverter, i have a 24v100H lithium battery with a charge voltage of 25v and a discharge cut off voltage of 16.5v...... cant figure how to set the bulk charge voltage in my 3kva inverter
if your battery is connected to the inverter through a bms port they is no need to set anything it will sync automatically if not, what the brand of the battery and inverter?
IVPS is transformer based Ivpm is transformer based with mppt(hybrid) Ivem is transformerless hybrid You choose according to your application and budget
Hello I need help. I have 550w solar panels in parallel. I'm getting 350v from the pv and about 425w is that correct or should I be getting a higher watts
@@colcent_solar okay thank you so much but would it affect anything? I have take positive from the 1st panel and negative from the last panel I have 8 I've connected + to -
If you mean charging with solar, the solar is not producing enough to load the house and charge the battery at the same time that why when you off them it will charge If you mean charging with Nepa, Take the inverter to repair center
How do you check how much battery you have? It's been used until the battery goes flat and the someone has to come recharge it. Unless my mechanic is conning me.
Your video is very educative. I have a 2.5kva 12v felicity inverter and it hums noticably like an airconditioner when the fan is blowing. Is this normal or do i have to report this?
Thank you so much for this timely content, I have a 5kva hybrid inverter ( felicity) the battery is same felicity 10kwh, the bms cable is connect and the installer set the float voltage at 57v, and the cut off voltage at 51v, but I notcie my battery has never charged up to 55v, it usually stopped charging at 53v
If the BMS connection is connected and the inverter and battery is communicating,you don't need to set anything,the two devices are in sync with each other
I installed this same inverter with 10kwh felicity lithium battery and I didn’t do all this settings. If It’s charging With solar, you see the battery bar reading. But if changing with grid and gen the battery bar don’t read. Please tell me what to do 🙏
Good enough for the price, reliability depends on how good the electrical work in the house is and also how good you use it. All things being equal Yes they are reliable but they are still more reliable products out there.
@@colcent_solar thanks again. I am trying to install solar in my village home. These batteries are available in Nigeria right? The reason I ask is that everything I see is felicity everywhere
hello, if i want to set the current charge from PV 25A since it's the max recommended amp as per the battery datasheet and from utility 20A i should put on option number 6 25A or what? i cant understand what this option mean PV + Utility
what you will see eg is pv + utility = 60A and then you will see utility only like 20A , meaning that the utility provides 20A PV 40A making 60A, if the utility +pv is 80A and you want to set pv to 25A set the utility to 55A
program 6 for utility and pv program 7 for utility if you dont want utility to charge the inverter you can set p6 to 25A and set p7 to 0A meaning that only the pv will provide all the 25A
But I start using 2 lithium batteries 200ah if I switch on the TV and fan sometimes the inverter it will shutdown I don't know the problem even if the batteries is fully charged
It's not showing any sign of low battery it can only start shouting and the light will take off, even if there is sun before I suspect the house wiring so I check every were I had not see any fault
Can i use two 5kva inverters at the same time with a set of 48Volts batteries? ( 4 batteries serialized to 48Volts, 2 5kva Inverters ( same brand, type and model ) ) outputting to 2 different loads? Will this damage the Batteries in any way e.g life span reduction, heating up etc? do I need to setup up any charging options on the Inverters? Just wondering if anyone here has done this?
Good evening.. I just installed this inverter 5kva. I switched it on and it came on and went off again with a fault light. I am asking, does it mean the inverter needs the 125v pv voltage to start, because I did this at night.
I have an issue with 120A Felicity charged controller, 16 320W panels connected 4 series and 4 parallel panels connection still unable to Charged 8 200A turbule battery to full capacity. Please explain what to do next
HI. great video. i am wondering how do i parallel 2 units of 5kva IVPS 5048 transformer-based ( low frequency ) Inverters? NO MPPT . I am unable to get them to display the code 29 option so as to set it to PAL. kindly assist pls. am I missing something? comm cables or what... However no comm cables came with this model.
That's a nice one pls I want to know my inverter output live wire is returning current to the input live wire when the input line is powered how can I solve the problem.
Good day sir.. pls I use this exact inverter.. but whenever I leave it to charge either by gen or sun, it drops very fast.. for example maybe its on 58% when I'm charging it with gen.. when i turn the gen off, it goes down to 51%
The inverter is just showing you the battery level,if the battery is dropping fast it's either the load is much , the battery is not well charged or the battery is bad
@@colcent_solar ok sir, so how many load should be on the inverter sir.. cause as of now there is 16% load on one, and 11% load on the other one... We have 2 inverters, 30 batteries, and 30 solar panel...
Mine isn't changing over from nepa to battery after any outage but the output would read 220v yet no power in the house but as soon as utility restore power it supply to the house. Can this be a configuration issue.
Good morning, please how can I set my hybrid Felicity inverter 5kva to charge with panel and light?
Nice meeting you God will reward nightly for the teachings
I love your video but I have a question please.
Out of the first 4 program, which one will I use and get to program 28 to parallel Felicity 10kva inverter
The first one,then to program 28
@@colcent_solar thanks
Good day sir
I have felicity 24v200ah
Whats the recommended bulk charging and float charging for rhis type
I have a question. 3:22 how about where the charge controller is separate, how do we set the charge current not to overcharge?
Good afternoon, pls what is that device above the pv fusebox, and how does it work, thanks.
Can I fix error 3? What is your advice. IVEM 5000w Thank you
Please can you help me out. I am interested in knowing the batteries being charged at 90Amps. I have always known battery charing current based on recommendation not to exceed 10 - 30% of its size. My ask is about 2:49 actually. I like to take some learnings... or is the setting for somethng different from the normal charging current we typically have on the inverter it self?
Hello engineer, please does that means that if I choose not to set the the inverter it might not charge or working properly?
it has the factory settings on it ,it will work ,the settings is by choice
It will work but charging current if is too high to gel battery it will damage them quickly you need to put on 25% to 30% and lithium 50%
I have a 3kw one, can we auto set this inverter to enable on and off of load without manually switching on lights?
No,for now
How about if you have two 15kw batteries how do you set the charging current
If the battery and inverter is communicating you don't need to set anything
Mine own out put use to carry refrigerator and electric kettle but now it can’t again please can you help me with a solution
hello, what would you recomend as my bulk voltage setting on my inverter, i have a 24v100H lithium battery with a charge voltage of 25v and a discharge cut off voltage of 16.5v...... cant figure how to set the bulk charge voltage in my 3kva inverter
if your battery is connected to the inverter through a bms port they is no need to set anything it will sync automatically if not, what the brand of the battery and inverter?
@@colcent_solar The battery is an LC-Star German Technology, then the inverter is a Must hybrid inverter PMV1800
what's the difference between felicity ivps, ivpm and ivem... And which is better
IVPS is transformer based
Ivpm is transformer based with mppt(hybrid)
Ivem is transformerless hybrid
You choose according to your application and budget
How can I set my MUST charge controller to 80Amp. Thanks
Hello I need help. I have 550w solar panels in parallel. I'm getting 350v from the pv and about 425w is that correct or should I be getting a higher watts
The wattage depends on the condition of the weather, orientation of the panels , quality of the panels etc
@@colcent_solar okay thank you so much but would it affect anything? I have take positive from the 1st panel and negative from the last panel I have 8 I've connected + to -
@@justinjimmy3234 No,it won't
The inverter is high voltage PV?
@@colcent_solar it's the same 5kva you have in this video. It's raining and cloudy I'm getting 335v and 590w
Ok
Hi I am having problem with the 5kva when ever I put on freezer or TV it will stop charging as soon as I put them off it will continue charging
If you mean charging with solar,
the solar is not producing enough to load the house and charge the battery at the same time that why when you off them it will charge
If you mean charging with Nepa,
Take the inverter to repair center
How do you check how much battery you have? It's been used until the battery goes flat and the someone has to come recharge it. Unless my mechanic is conning me.
Your video is very educative. I have a 2.5kva 12v felicity inverter and it hums noticably like an airconditioner when the fan is blowing. Is this normal or do i have to report this?
The fan makes sound when on
Thank you so much for this timely content, I have a 5kva hybrid inverter ( felicity) the battery is same felicity 10kwh, the bms cable is connect and the installer set the float voltage at 57v, and the cut off voltage at 51v, but I notcie my battery has never charged up to 55v, it usually stopped charging at 53v
If the BMS connection is connected and the inverter and battery is communicating,you don't need to set anything,the two devices are in sync with each other
Nice video, please how fast can you charge the 10kwh battery with this inverter?
Very fast
I installed this same inverter with 10kwh felicity lithium battery and I didn’t do all this settings. If It’s charging With solar, you see the battery bar reading. But if changing with grid and gen the battery bar don’t read. Please tell me what to do 🙏
How reliable are the Felicity products?
Good enough for the price, reliability depends on how good the electrical work in the house is and also how good you use it. All things being equal Yes they are reliable but they are still more reliable products out there.
@@colcent_solar thank you. Can you tell me what the better products are in Nigeria?
victron, deye or sunsink ,growatt
for batteries BYD and BSLBATT
@@colcent_solar thanks again. I am trying to install solar in my village home. These batteries are available in Nigeria right? The reason I ask is that everything I see is felicity everywhere
the batteries are available
Hi bro. I have felicity 3000va. Whenever i on freezer or blender it shows 02 error..
What is the cause of code 03 on this hybrid inver and likely solution
Warning code 03 low battery
Error code 03 internal component failed
@@colcent_solar yes it a new inverter on it first charge when it reach 45% it pop the alarm
09065594904 send a video for me on WhatsApp
Is your inverter hybrid ?
Yes sir
hello, if i want to set the current charge from PV 25A since it's the max recommended amp as per the battery datasheet and from utility 20A i should put on option number 6 25A or what? i cant understand what this option mean PV + Utility
what you will see eg is pv + utility = 60A and then you will see utility only like 20A , meaning that the utility provides 20A PV 40A making 60A, if the utility +pv is 80A and you want to set pv to 25A set the utility to 55A
program 6 for utility and pv
program 7 for utility
if you dont want utility to charge the inverter you can set p6 to 25A and set p7 to 0A meaning that only the pv will provide all the 25A
Engineer how many batteries can I going to use with 3kva Felicity solar inverter and on fridge
4 batteries of 220ah is ok
Thank you sir
But I start using 2 lithium batteries 200ah if I switch on the TV and fan sometimes the inverter it will shutdown I don't know the problem even if the batteries is fully charged
Does the battery show low when the inverter off?
It's not showing any sign of low battery it can only start shouting and the light will take off, even if there is sun before I suspect the house wiring so I check every were I had not see any fault
Can i use two 5kva inverters at the same time with a set of 48Volts batteries? ( 4 batteries serialized to 48Volts, 2 5kva Inverters ( same brand, type and model ) ) outputting to 2 different loads? Will this damage the Batteries in any way e.g life span reduction, heating up etc? do I need to setup up any charging options on the Inverters?
Just wondering if anyone here has done this?
Good evening.. I just installed this inverter 5kva. I switched it on and it came on and went off again with a fault light.
I am asking, does it mean the inverter needs the 125v pv voltage to start, because I did this at night.
No it does not, check the fault code and the meaning from the manual
Sorry I mean 3hp normal ac can it carry just it
I have an issue with 120A Felicity charged controller, 16 320W panels connected 4 series and 4 parallel panels connection still unable to Charged 8 200A turbule battery to full capacity. Please explain what to do next
The quality of the panels,position, temperature,wire sizing etc can affect the performance of the charge controller
4*4 parallel is about 40A you will not see more than 60A
4*4 parallel is about 40A you will not see more than 60A
Good evening.
Please, the output of my inverter has been fluctuating from 214 to 218v and thereby no supplying power
What can I do Please?
Why Gen & NEPA cannot charge my inverter
HI. great video.
i am wondering how do i parallel 2 units of 5kva IVPS 5048 transformer-based ( low frequency ) Inverters? NO MPPT . I am unable to get them to display the code 29 option so as to set it to PAL.
kindly assist pls. am I missing something? comm cables or what... However no comm cables came with this model.
it does not have parallel options
@@colcent_solar Thanks Boss. you are appreciated.
My 10kva new inverter keeps shooting down becos the two output fan not working,what could be the cost
it will display a code before shooting down ,whats the code number?
That's a nice one pls I want to know my inverter output live wire is returning current to the input live wire when the input line is powered how can I solve the problem.
some inverters are built that way or your inverter is faulty
@@colcent_solar once the current to the input live line it will tripped off the voltage protector (the inverter is Felicity solar
please i need settings for 3.5
kva SMKsolar hybrid wit tubular battery
Just change the battery type to FLD,set the float and equalization voltage according to the battery specs , check the manual for steps
@@colcent_solar i will try that, thanks
@@colcent_solarcan i get your phone number sir
@@colcent_solarplease how do i set the float and equalization voltage or I'm just to put it on FLD and it will do that automatically?
No,check the datasheet of the battery online and set it to the inverter accordingly,the steps to this can be found in the inverter manual
Good day sir.. pls I use this exact inverter.. but whenever I leave it to charge either by gen or sun, it drops very fast.. for example maybe its on 58% when I'm charging it with gen.. when i turn the gen off, it goes down to 51%
The inverter is just showing you the battery level,if the battery is dropping fast it's either the load is much , the battery is not well charged or the battery is bad
@@colcent_solar ok sir, so how many load should be on the inverter sir.. cause as of now there is 16% load on one, and 11% load on the other one... We have 2 inverters, 30 batteries, and 30 solar panel...
30batteries of how many amps,30panels of how many amps?
Sorry sir, how can I check the amps?? It's not showing on the body sir..
@OmohFelly its in the body like 12v/200ah
Please how to set the battery on tubular...?
Same process instead of LIB(lithium) chose FLD(flooded) same as tubular
Mine isn't changing over from nepa to battery after any outage but the output would read 220v yet no power in the house but as soon as utility restore power it supply to the house. Can this be a configuration issue.
did the problem just started or it has been there?
@@colcent_solar it is a new installation.
@@renew6255 it maybe connection error or factory error from the inverter
@@colcent_solar should I tell the installer to replace it since it's still on warranty.
@@renew6255 tell him to come and check it
Hi Sir
I have Gel batteries
Where do I change ot correctly?
AGM
Hi Sir
Can you please tell me under what Code settings can I change Battery type?
Program 8 ( AGn )
Greetings let me see the selection for tubular battery and also battery low voltage cut off too
Boss can this 5kva carry 3hp fridge
yes
Hello how can I set my Felicity 10kva to maximum charge cutoff
its automatic once the battery is full the inverter will stop charging you dont have to set it
Hello! I am a Solar Energy Engineer and Installer, how do I work with you?
09065594904 chat me up
Please how does one contact you over the phone
09065594904
Goodmornin do you really need to make this set-up if ur installing new 5kva inverter
Not really
I have error code 34 when the power goes off. I have battery. Do tou know how to configure to avoid such error on power off?
Error 34 means over load or output short circuit
Check the load and the wirings make sure everything is adequate
Seek the help of a technician if needed
Please my problem is, if I on ac out the battery will stop charging
The solar is not producing enough to load the house and charge the batteries at the same time that's why
please my inverter not charging with nepa
Good morning sir
Please mine stopped charging from solar panel and I don't know how to reset it
Please assist me 🙏🏻
Haw to make the pv charge the battery
I also have one 7.5kva that one of the fan doesn’t pick
maybe the fan is bad
@@colcent_solar the inverter is a new one
if the inverter is not showing any error everything is ok
Pls sir my charging level is not displaying in the inverter and my battery is lithium
maybe the inverter is not charging the battery or the display is bad
My ivem3024 doesn't bypass
check the settings, maybe the output source Priority is solar and battery
His sir please i am. Habing problem woth th pv panel is ov and the pv pannel icon is not showing on the screen
chat me on whatsapp 09065594904
Did you resolved this issue? My pv doesn’t show on the screen.
If you are using a separate charge controller,the PV will not show on the inverter.
Check your breakers and wiring
If it's still didn't show, contact your installer
Let him check the pv voltage if it is within range 110-500vdc
ممكن صورة الكاتلوج
Mine is showing red light and making alarming sounds
whats the error code
❤❤❤😊
I have error code 34 when the power goes off. I have battery. Do tou know how to configure to avoid such error on power off?
My inverter is 48 V hybrid inverter 10 kilowatts
Cut off on 48v low battery voltage
Pls bro how can I get ur contact
09065594904 whatsapp
My inverter is making a beep sound
Which inverter is that
@@colcent_solar felicity
@@colcent_solar the exact same one you’re working with
@@colcent_solar it’s been making noise for the past 5 hours how do I turn it off completely?it would really help
As the inverter dy beep what's the error code?