Varmepumpemontasje i Molde

Поделиться
HTML-код
  • Опубликовано: 15 янв 2025

Комментарии • 28

  • @mariomarchelo3999
    @mariomarchelo3999 Год назад +1

    Winter wonderland.

  • @konsul2006
    @konsul2006 Год назад +1

    That is quite a long few meters of pipes from the indoor- to the outdoor unit. Does this affect efficiency to any notisable degree?

    • @HowieNOR
      @HowieNOR  Год назад +1

      this is about 5 meters (~16.5 ft) with pipe. this exact unit is rated for 15m (~50ft) without extra filling of refrigeant. with extra it's possible to reach around 20m (~65,5 ft). I doubt that this length is having any impact on the efficiency.

  • @waledtaha422
    @waledtaha422 Год назад

    Hvor lang tid bruker man ca på installasjon av brukt varmepumpe fra Panasonic? Trwnger man både elektriker og montør?

    • @HowieNOR
      @HowieNOR  Год назад

      Hei
      montasjetid vil variere veldig avhengig av tilkomst og lengde mellom inne- og utedel. typisk varer en installasjon fra 3-8 timer.
      man trenger både elektriker og montør, men noen elektrikere er også varmepumpemontør.
      sjekk litt rundt og snakk med noen i nærområdet, så kan de komme med forslag / tilbud ;)

    • @hanzo52
      @hanzo52 3 месяца назад

      @@HowieNOR Er det lov å montere og legge opp alt av rør og ledninger og få elektriker/montør til å koble opp? Er nevenyttig til å få dette til selv.

  • @stianjarnass
    @stianjarnass 4 года назад

    Kan man ha flere innedeler på Daiseikai 9-35? Har ett to etasjer gammelt trekkfult hus🤗

    • @HowieNOR
      @HowieNOR  4 года назад +1

      Ikke mulig å ettermontere, men mulig å ha to innedeler (M18 heter maskina da). Du vil også få mindre effekt siden du må dele effekten på 2 innedeler.
      Jeg ville anbefalt å snakket med en leverandør og fått en befaring 😉

    • @stianjarnass
      @stianjarnass 4 года назад

      Takker, ja det skal jeg gjøre🤗

  • @sjokomelk
    @sjokomelk 5 лет назад

    Hvor gjorde du av dreneringen til innedelen? Kan ikke si jeg så noe rør som forlenger dette helt bort til utedelen.

    • @HowieNOR
      @HowieNOR  5 лет назад +1

      Den ble lagt ut igjennom terminalen/dekslet ved gjennomføringen.

    • @sjokomelk
      @sjokomelk 5 лет назад +1

      @@HowieNOR Så den drenerer bare ut midt på veggen?

  • @igormossounov2334
    @igormossounov2334 3 года назад

    How do you check for leakage? Pressure and dP or Pressure and No bubbles?

    • @HowieNOR
      @HowieNOR  3 года назад +1

      Using nitrogen (N2) to 25 BarA, then spraying on either soapy water or leak finder spray. Next I vacuum down as low as possible, (under 200 microns) and put shut the valve to the vacuum pump. If the vacuum has not risen over the 200mic limit after 10-15 mins, I open the valves and let the gas out to the pipes.

    • @igormossounov2334
      @igormossounov2334 3 года назад

      @@HowieNOR Thank you for answer. IMHO better use special reductor and pressurise till 40 Bar (R410a and R32 working pressure even higer). About vacuum - it is waste spend of time; dP is too low for small leakage detection;
      Please, could U inform about brand and model of leak finder spray. Thank you.

  • @axab2004
    @axab2004 3 года назад

    Why in 2021 there is nothing for central air conditioners with wired Toshiba RAV SM 806 BTP-E consoles it was necessary to make a remote control, albeit a wired remote control, but to have an IR sensor or make it possible to connect it to the indoor unit board

    • @HowieNOR
      @HowieNOR  3 года назад

      not quite sure if i understand your comment, but the units for duct connection (BTP-E) can be connected to an wired remote, or an IR remote.
      you can also get an Modbus interface if you have a home automation system that can communicate over modbus.
      the newer version of the 800 series would be an Toshiba RAV-GM801ATP-E / RAV-RM801BTP-E (outdoor unit / indor unit)

    • @axab2004
      @axab2004 3 года назад

      @@HowieNORhow can i connect it to IR remote ?

    • @axab2004
      @axab2004 3 года назад

      ​@@HowieNOR Is there some kind of module for this, if there is, what is it and how to connect it?

    • @axab2004
      @axab2004 3 года назад

      @@HowieNOR You write that : connection (BTP-E) can be connected to IR remote. Okay, can I do it, what do I need for it?

    • @axab2004
      @axab2004 3 года назад

      @@HowieNORand what do I need to buy for this so that I can use IR remote

  • @roccotalarico847
    @roccotalarico847 5 лет назад

    Mitsubishi ln or Toshiba super daisekai 9 ? What Is the best ?

    • @HowieNOR
      @HowieNOR  5 лет назад +1

      personally I like the Toshiba D9 best,
      but check the spec on both machines in your climate, there could be differences
      and most important find a supplier/installer in your area who is serious about it. cheapest is not always best ;)

    • @roccotalarico847
      @roccotalarico847 5 лет назад

      @@HowieNOR thank you for the reply... Why do you prefer Toshiba?

    • @HowieNOR
      @HowieNOR  5 лет назад +1

      @@roccotalarico847 Mainly because that's what i work most with. And in my experience so far, is it less problems with them.
      no hate over the other brands, they have many good machines as well.

    • @jevelskab
      @jevelskab 3 года назад

      Daikin is easy'er to do service on later on (change of data card etc) .

  • @waolsful
    @waolsful 9 месяцев назад

    Kjeltring. .. Totalt galt montert

    • @HowieNOR
      @HowieNOR  9 месяцев назад

      hva mener du er galt? har montert en hel drøss tilsvarende, og har ikke hatt klager 😅