Testing the JK BMS... but instead I found a problem! 🤔😑

Поделиться
HTML-код
  • Опубликовано: 1 янв 2025

Комментарии • 269

  • @AndreaFurlan-ro8cw
    @AndreaFurlan-ro8cw Год назад

    Hello Andy, thank you for everything you're doing for everyone on your channel. I'd gladly buy you a beer, especially since I also lived in Queensland, Australia, 10 years ago and know exactly what summer, thirst, and 40 degrees outside mean😊.
    Keep it up, I always follow you!
    P.S. I just bought the J.K. BMS, can't wait to receive it!
    Thank you very much!

  • @danielardelian2
    @danielardelian2 3 года назад +22

    11:05 When everything is OFF, you are practically measuring the voltage difference of two power supplies that have a common positive pole.
    The charger has 56.00 V and the battery open-circuit voltage is 55.60 V.

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +8

      And later on, the discharge is off which means you have a voltage drop over the discharge mosfets's parasitic diode. Enabling discharge eliminates this problem. The BMS does this automatically at higher currents, even if you disable discharge - however in this case the BMS will still prevent the battery from discharging once the charge current drops again.

    • @diydsolar
      @diydsolar 3 года назад

      But it is impossible to be off when he is trying to charge with 100ma, 1a, 2a, ... until 5a

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +6

      @@diydsolar Charging was on, discharging was off. At low currents, the discharge mosfets are just parasitic diodes. As soon as the current increases, the BMS enables the discharge mosfets, and now the drop is gone and charging continues as usual. If he had discharge enabled from the beginning, he would not see this.

    • @diydsolar
      @diydsolar 3 года назад

      @@upnorthandpersonal thanks I understand you. You are right. Only one question.... May be you have disabled discharge for any reason.... why does the bms has to enalbed it ? May be risky in same cases ?
      Does daly do the the same ?

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +4

      @@diydsolar It doesn't - it only does this when the charge current grows, which means there is current not used for the load and the battery would not be discharged in any case. Once the current drops, the settings take effect and prevent any current from going out of the battery. In other words: the setting means: 'don't discharge the battery', which is doesn't.

  • @teardowndan5364
    @teardowndan5364 3 года назад +19

    15:05 the large voltage difference across the BMS FETs has nothing to do with how much current the BMS is passing. You DISCONNECTED the battery from the power source by turning off charge and discharge, so the battery and source voltage are now independent just like they would when the contactor is open on the Q BMS. No current (open switch) = "large" difference, high current (closed/connected switch) = low voltage difference. Same as measuring voltage across a a ceiling light switch: light is on, 0V across the switch, light is off, full AC mains voltage across the open switch.
    It may not be as you would like it to be but it isn't defective. With a FET-based BMS, you can set your PPT to 58.2V fixed max voltage and let the BMS disconnect charging whenever necessary.

  • @ascii892
    @ascii892 3 года назад +11

    Andy, Since the charge and discharge are disabled, the BMS is basically an open switch. the 350mV you are measuring is the difference between the charger and the battery.

    • @mediadaemon
      @mediadaemon 3 года назад +1

      This was hard to watch, I was like ITS OPEN ANDY!

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +3

      Actually, the real issue later on in the video when he has charging enabled is that he has discharging disabled. This means he's measuring the drop over the parasitic diode in the discharge mosfets. All he needs to do is enable discharge...

  • @danielardelian2
    @danielardelian2 3 года назад +24

    15:36 I can see discharge is OFF on your phone. The missing 0.4 V is the drop across the parasitic body diode of the DISCHARGE MOSFET being turned OFF.
    PLEASE repeat the test at 16:00 with the Discharge ENABLED.

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +5

      Exactly.

    • @MrHantu666
      @MrHantu666 3 года назад

      @@upnorthandpersonal No, it's two completely separate power sources with a shared ground. He's measuring a battery and measuring a power supply that are completely disconnected from each other and getting obviously differing results

    • @howardschlunder9754
      @howardschlunder9754 3 года назад +3

      @@MrHantu666 No, they are not sharing a ground reference. The battery and BMS ground reference is the B- wire. The power supply ground reference is the P- wire. Between B- and P- are two MOSFETs connected back to back in series, but with opposing polarity. One MOSFET permits current inflow while on and turns into a reverse biased blocking diode while off and still trying to charge. The other MOSFET permits current outflow while on and likewise turns into a diode while off, however since it is connected in reverse polarity of and in series with the charging MOSFET, this diode is in forward conduction while the discharge MOSFET is off and you still force current into the battery. The only time B- and P- are the same ground reference is when both the charge and discharge MOSFETs are both on simultaneously. The BMS automatically turns on the discharge MOSFET during charging (despite being off in the App) when it detects sufficient charge current to avoid overheating the body diode in this discharge MOSFET.

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +2

      @@MrHantu666 Later in the video he has charge enabled, closing the switch - he still measures the gap. It's when he's slowly increasing the voltage on the charger, sees low currents and a big drop until it suddenly changes. That's the point where the BMS opens the discharge mosfets. The drop before that happens is the diode voltage drop of the closed discharge mosfets.

    • @greg6609
      @greg6609 3 года назад

      I am glad I wasn't the only one to see this.

  • @sebastienl2140
    @sebastienl2140 3 года назад +7

    It's not a special feature, on all mosfet bms there is 2 mosfet Nch in serial configuration, one for charging one for discharging.
    When you don't activate discharge mode and at very low current charging, mosfet discharging is off (voltage drop is 0.5V) but when charging current is consistent bms activate mosfet discharging to remove this 0.5V body diode drop, even discharge mode is off.
    There is absolutely no problem at all.

  • @PRASTRO
    @PRASTRO 3 года назад +6

    Andy, Andy you only have to turn on the discharge switch and your problems ar solved 👍🏻

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      I know now. It's been discussed in the community section of the channel already BEFORE you made this post 😁

  • @camro210
    @camro210 3 года назад +4

    I have a *similar* behavior on my Overkill/JBD BMS, and like I have seen a few others mention, it depends on the charge/discharge switches in the BMS app. I have a shunt connected on the negative side, downstream of the BMS, and when I turn the charging off through the BMS, the voltage reported by the shunt is about half a volt lower than the voltage reported by the BMS. If I turn the charging back on in the BMS then the shunt sees full voltage again (even with no charge voltage applied).

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      Yeah, usually, charge and discharge are both turned on and they get disabled if the BMS if voltage goes too high or low. My discharge was turned off manually. It's in the next video.

  • @stephenrebelo788
    @stephenrebelo788 3 года назад +3

    Andy get the new 500A version of the QUCC BMS they have their new version with 2 contactors. One for Charge & one for discharging. The reason I say this is because at some stage you will want to parallel your battery banks. With a MOSFET based BMS you cannot parallel at all. So you have a pending problem with your JK BMS in the future already. Please go ahead & run the experiment yourself. The behaviour of the parallel BMS will scare the living day lights out of you. The QUCC guys are really onto something good with their contactor approach! Great Video thank you again...

    • @kuhrd
      @kuhrd 3 года назад +1

      Why can't you parallel banks with a MOSFET BMS? I say this because I have 3 banks in parallel running my house and they have been in parallel for over a year without an issue. Not really sure what issus you are having where you can't parallel multiple MOSFET based BMSs.

  • @wayne8113
    @wayne8113 3 года назад +1

    Thanks Andy

  • @kirbarton
    @kirbarton 3 года назад +2

    Andy, you are measuring the difference between two power supplies because the MOSFETs are not conducting, that is why when you rise the power supply voltage the voltage difference rises

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      Yes, that is correct. We discussed this in the community section and it is in the new video 😊

  • @alexschulein7002
    @alexschulein7002 3 года назад +16

    Andy... Your charge setting in the BMS is off, the FETs in the BMS is in high resistance mode, the loss you think you have is no loss, it's just a difference between your power supply and the battery state because the FETs are not conducting.

    • @TheGalifrey
      @TheGalifrey 3 года назад +5

      Understanding Ohm's Law is essential when you make videos like these haha

    • @alexschulein7002
      @alexschulein7002 3 года назад +2

      @@TheGalifrey don't want to uhm rain on you parade here but this has nothing to do with ohm's law. Since there is no current to induce a voltage in a resistance, ohm's law doesn't apply. This is just a matter of two voltage sources sharing a common and measuring the other side

    • @babaluto
      @babaluto 3 года назад

      @@alexschulein7002 as in an idle voltage divider. Still doesn't seem to explain the quiescent voltage state. Curious.

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +9

      @@babaluto It's just the drop over the parasitic internal diode of the discharge mosfet - he has discharge disabled in his settings. Enabling discharge eliminates this problem. The BMS does this automatically at higher currents, even if you disable discharge - however in this case the BMS will still prevent the battery from discharging once the charge current drops again.

    • @alexschulein7002
      @alexschulein7002 3 года назад

      @@upnorthandpersonal yes this seems very logical, i have no experience with this BMS or any BMS but I do have a good understanding of electronics.
      I wonder if Andy would be so kind to repeat the measurements with discharge and charge ON in the BMS to confirm

  • @RapidCRM
    @RapidCRM 2 года назад +1

    This video is very interesting and informative. Can you please clarify how the charger is disconnected from the battery pack without the load being disconnected. I have a Chargery BMS16 that has a connection to a relay that disconnects the charging if cell differences are above settings or an individual cell is above maximum. This doesn't affect the load.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  2 года назад

      The JK-BMS (like many others) use MOSFET transistors to control the charging and discharging separately. One side can be turned of but it still lets the current flow in the other direction.

    • @MMMM2MMMM2MMMM
      @MMMM2MMMM2MMMM 2 года назад

      How did you solve it?

  • @elpihendi6793
    @elpihendi6793 2 года назад +1

    how do you manage BMS - battery - remote monitoring with Victron energy app -? Thx

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  2 года назад

      All Victron gear natively shows in the VRM. To connect the BMS as well, we need to modify a few things. It will come later on this channel once the battery is in place and working.

  • @maxklinger6023
    @maxklinger6023 3 года назад +1

    Andy, perhaps is needs a trickle to charge a capacitor ready for the balancing stage so it depends at what stage some of the other parameters are at.

  • @vaneay
    @vaneay 3 года назад +1

    on the dally BMS both mosfets are tuned on ( charge and discharge ) so their body diode are bypassed by the mosfets hence the low drop voltage of few mV across the BMS P- and B-

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад +1

      As we discussed in the community post two days ago... I know now 😊

    • @vaneay
      @vaneay 3 года назад

      @@OffGridGarageAustralia thanks ! Did not see the community post before the video so I m late on the topic 😋

  • @madtec3348
    @madtec3348 3 года назад +1

    C an you put different ah together like 100 ah with 215 or 275???

  • @svtosca3371
    @svtosca3371 3 года назад +12

    @andy Why is this a problem? You have a Victron smartshunt that measures accurately at the battery and sends that to your Victron smartsolar. So your smartsolar allways uses the proper battery voltage and doesn’t use the voltage it measures itself. So No problemo then. That is what makes Victron great stuff to work with.

    • @lexicase8805
      @lexicase8805 3 года назад

      Because the plan is to use more than one 16s pack, each having its own bms and then they will be paralleled after the bms, at least this is my understanding of the new plan Andy has. The victron will only use the voltage reading from one place, so the victron gear wont help with Andys new setup. If the plan was to combine this bms with a Victron shunt or smart battery sense on a single pack, sure it would not be an issue.

    • @svtosca3371
      @svtosca3371 3 года назад

      @@lexicase8805 hmmm… 2x16s would balance out so measuring on one bank should still work fine. After all, if one bank has a lower voltage it will get the grant of the charge would it not?

  • @sawomirmaksimowicz8191
    @sawomirmaksimowicz8191 3 года назад +1

    Try to change over voltage protection for battery bank in BMS to +0,4V and check if it will allow to charge on top.

  • @edwardbyrd7667
    @edwardbyrd7667 3 года назад +3

    I am confused. If you opened all of the connections in the BMS then are the battery and the charger two isolated systems? Why would you expect their potential to remain the same if they are isolated. The battery will begin its journey towards 53.7, while the supply will be fixed by its AC side. What am I missing?

  • @alexandergunda8916
    @alexandergunda8916 3 года назад +1

    @Andy - just an early in the morning theory: the BMS itself has a consumption for it's internal controler and BT. As soon charging happens it takes it's power from the "charging line" but not before - maybe this has something todo with the observed behaviour?

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      This comes all from the battery though and not from the charger. And, it is very little >10mA.

  • @Dutch_off_grid_homesteading
    @Dutch_off_grid_homesteading Год назад

    Heya, oke that good be a rabbit hole to solve this because it is working🙃

  • @Drillmechanic
    @Drillmechanic 4 месяца назад

    Discharge should be on to open the BMS discharge mosFETs!

  • @hommerdalor6301
    @hommerdalor6301 3 года назад

    Where does the Bluetooth module take his power from? from the charger when charging, from the battery when not charching?

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      It's been powered from the battery. Otherwise it would stop when no charger is connected.

  • @JeremyAkersInAustin
    @JeremyAkersInAustin 3 года назад +1

    Andy Andy Andy... :) At 9:37 you said "If they are turned on, if they are conducting there should be almost no voltage drop at all"
    Right... but you just showed us that you had them turned off. :D
    Yes I know I'm probably really late to the party. Still catching up.

  • @BradCagle
    @BradCagle 3 года назад +1

    It's probably not defective, it's probably just a bad design. 0.4v sounds like the voltage drop of a diode, BTW power mosfets have diodes built-in between the source and drain. This might be what you're seeing.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад +1

      Thanks, yeah something like this. I show it in the second video from this morning.

  • @jasonbroom7147
    @jasonbroom7147 3 года назад +1

    I think it's good that someone looks at the minutiae of these things and questions every tiny little detail. For me, I am really more interested in the practical application (usage) of the batteries, charge controllers, inverters and solar panels. I don't worry about 1/3 of a volt over a 16S pack, when it is at rest. In practical use, the pack will typically be charging and/or discharging most of the time, so this "deviation" will be negligible, if it exists at all. It seems like it went away when the pack was charging, so is this a deep dive into something of little consequence? I don't know for sure, but it seems that way to me.

    • @arebear4797
      @arebear4797 3 года назад +1

      Agreed.. if you see the cell voltage is at 3.55-+. that perfectly good for any setup practically. we not sending rocket ship to venus here till we need to make sure the battery full at exact 3.65V at all time.
      Mean here practically if this is genuinely how the BMS behaviour,, no issue at all.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      0.6V could the the border you don't want to cross though.

  • @waldi2909
    @waldi2909 2 года назад +1

    Sehr interessante Videoreihe (Kanal ist direkt abonniert). Vielen Dank dafür. Weiter so! 🙂

  • @wenhaowong5549
    @wenhaowong5549 3 года назад +1

    turn on both charge and discharge function in the bms, and check the voltage again.

  • @vaneay
    @vaneay 3 года назад +1

    enable both mosfets ( charge and discharge toggle switchs) you will not have the 0,6v delta on charge with low current

  • @rcinfla9017
    @rcinfla9017 Год назад +1

    When you have charging or discharging disabled it turns off one side of back to back MOSFET's. The other allowed current direction has a MOSFET body diode voltage drop from the turned off MOSFET. That gives you the 0.6v drop across BMS.
    To make things more complicated, if current gets above 3-6 amps on the non-disabled path, the BMS will override the disable setting and turn both back to back MOSFET's back on. This is to avoid too much heating of MOSFET's due to the higher current and extra MOSFET body diode voltage drop. Current will be monitored by BMS current shunt (level and direction of current flow) and restore the disable setting when the allowed pass current drops back down to low levels.
    You should not use the disable function for anything but supervised testing.
    One problem BMS does have is with cell overvoltage charge disable, coupled with a sporadic higher discharge currents from inverter is the charge disable override to handle the sporadic moderate discharge current. Because the MOSFET turn on and tun off time is slow in BMS, there will be a short 'squirt' of charging when inverter load drops off and the BMS goes back to disabling the MOSFET that blocks charge current. There is some delay in re-disabling charging that allow a short 'squirt' of charging current to leak through to battery for a fraction of second. If inverter load is bouncing up and down causing BMS override of charging disable to turn off and on it can end up overvoltaging a cell beyond the overvoltage cell cutoff voltage. Nothing you can do to stop it other than control the inverter discharge current from happening or disconnect any charging source.
    o

  • @MrSeb-455
    @MrSeb-455 3 года назад +3

    Hi, one question. Do you think you can connect this JK BMS to the Victron GX device via CANBUS?

  • @john_in_phoenix
    @john_in_phoenix 3 года назад +2

    Yes, way too many people "balance" by placing cells in parallel. You have both sets of FETs turned off, pretty normal. The 2 amp trigger is pretty standard. If you let the Daly go to sleep, it will exhibit the same behavior.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      Thanks John. I'll test the Daly again and play around with the charge/discharge option.

    • @john_in_phoenix
      @john_in_phoenix 3 года назад +1

      @@OffGridGarageAustralia Trust me, the Daly is not worth the effort. It will work fine, but the quality and reliability are missing ingredients.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      @@john_in_phoenix I can see this already since my first year.

  • @Cooldudeblue261
    @Cooldudeblue261 3 года назад

    Ive learned a lot from you. My packs i charge to max 3.55 and cut off at 2.5 . Hardly need a bms . Never get run away cells . I think the internal circuit is using some power maybe? Try disconnect the +ve and see what happens.

  • @vaneay
    @vaneay 3 года назад +1

    it is normal behavior , you have turned off charge and discharge mosfets so the battery is disconnected from the power supply, you set your power supply higher than the battery , hence the voltage difference

  • @rickard1802
    @rickard1802 3 года назад +1

    Daly bms behaves the same if you turn off discharge switch and charge switch then turn charge switch back on and try to charge.
    The bms have a capacitor (or something that behaves like one) between BMS and P- conductor.

  • @reneroman1421
    @reneroman1421 2 года назад

    Hi....How can I synchronize the JK bms so that it gives the correct reading of the SOC? I was making some parameter changes and when I clicked "ok" I changed the SOC to a lower one (100% to 76%), the battery was already at 100% (54.4V). .I need help

  • @RuoKimPee
    @RuoKimPee 2 года назад

    B+ B- BMS standby power with Bluetooth or not?

  • @MrHantu666
    @MrHantu666 3 года назад +1

    It's the battery voltage and the power supply voltage, they are separate but with common ground. Turn the power supply knob and you'll see!

    • @MrHantu666
      @MrHantu666 3 года назад

      I mean they are turned off so no longer connected together apart from the ground.

  • @bendelongis2945
    @bendelongis2945 3 года назад +1

    Is the the P-N junction forward bias?

  • @dave3005
    @dave3005 3 года назад +1

    Just curious, why do you set your clocks to 24 hour time? I am retired US military and do the same thing out of habit.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      Because I'm from Europe where this is the norm. Easier for me to read and understand

  • @Mike_Neukam
    @Mike_Neukam 3 года назад +1

    The voltage drop measured is the difference of potential between the two power sources and is what you would expect to see when the mosfets are turned off. In at least one of your demonstrations, it appears that you have manually disabled the mosfets. If the mosfets are turning off automatically when idling, then that is the problem. Look in the app to see if there's a setting to disable that behavior.

  • @holgerj7520
    @holgerj7520 3 года назад +1

    Doesn't the battery sense tell the charge controllers the correct voltage and they can compensate?

  • @totobox918
    @totobox918 6 месяцев назад

    good morning Andy, I also wanted to try out the JK bms but... The device seems well made but mine....does not seem to be reliable.
    2 weeks ago I received the B2A20S20P model so without instructions I installed the app Ver. 4.21.0 on V11.XA hardware Version
    Now, I notice that I cannot edit Calibration current as you do in the videos and when I activate the Balance from the control panel
    in the settings screen it is disabled as well as the Discharge. ..In my opinion this Ver. is still full of bugs
    But the worst thing is when I have a load like a simple heat gun on the Bms I have -40A😳 , confirmed with ammeter.
    Yesterday a water pump (2HP) started and the ATS (100A) burned out probably due to too many amps.
    What to do in these cases, does it depend on the software, the settings or BMS to be thrown away?
    Ask for a HEELP to the whole team. thanks

  • @Sanwizard1
    @Sanwizard1 3 года назад +2

    Ask JK how much energy the Bluetooth is pulling to stay on?

  • @lanealucy
    @lanealucy 3 года назад +1

    Irgendwie erinnert mich das ganze an die float Funktion von den Laderegler, wenn der Strom unter 1,5A fällt, wird die Spannung vermindert, könnte also vielleicht ein Feature sein

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      Aber ein BMS hat doch keine Float Funktion...

    • @lanealucy
      @lanealucy 3 года назад

      @@OffGridGarageAustralia ein BMS ist dafür da, Akkus zu managen, wo auch der Schutz und die Erhaltung zu gehört, warum sollte ein BMS sowas also nicht haben?

  • @peterwalker7869
    @peterwalker7869 3 года назад

    You say no current is flowing? But what powers the BMS BlueTooth?

  • @extremeacc101
    @extremeacc101 3 года назад

    I have always wanted to do this well done to you Andy.
    I too can confirm the DALYBMS has very minimal voltage deviation.
    Voltage readings from the BMS compared to the battery monitoring system are identical.
    I agree with you and would say it would be a faulty BMS.

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +4

      No, he's got discharging disabled and is measuring the parasitic diode voltage drop from disabled mosfets. It's absolutely normal behavior - all e needs to do is enable discharge.

  • @jasondevine6014
    @jasondevine6014 3 года назад

    I wonder is you are measuring the gate bias voltage. Try measuring under load that is what matters

    • @jasondevine6014
      @jasondevine6014 3 года назад

      It could also be a design feature. If the current is under a certain amount it may use a different current sense resistor for higher accuracy.

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +1

      @@jasondevine6014 He's just measuring the voltage drop over the parasitic diode of the discharge MOSFETS. He disabled discharge in the app, which means these MOSFETs aren't active until a certain current flows (the BMS has to prevent the battery from providing any current as per this setting, but will enable these discharge MOSFETS once enough charge current is flowing). If he enabled discharge in the app, the 'problem' would be gone...

  • @jackoneil3933
    @jackoneil3933 3 года назад +1

    I would call it defective at this point, but offhand I can't imagine why you are getting a such a high forward voltage drop across the MOSFETs in the charge direction. Do you also see a similar drop going the other way under load?
    If you have an scope you might check for a frequency in that voltage drop that might indicate the MOSFETs are being switched on and off rapidly, suggesting some issue with the MOSFET trigger voltage supply.

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +2

      He gets the voltage drop from the discharge MOSFETs, which he has turned off in the app. Charge and discharge MOSFETs are in the same circuit. When discharge is disabled, these MOSFETs act as a diode (parasitic diode in the MOSFET). Once the charge current rises, the BMS enables the discharge MOSFETS as well. That's what he's seeing when he increases the voltage to see that 1.5A current. The discharge function still works as expected: the battery will not be discharged since as soon as the charge current drops again, the discharge MOSFETs are off again as per the settings.

    • @jackoneil3933
      @jackoneil3933 3 года назад

      ​@@upnorthandpersonal Seems a plausible explanation. I did not notice such a setting did you?

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +1

      @@jackoneil3933 yes, at 10:43 in the video. I have the same BMS as well.

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +1

      @@jackoneil3933 Also, at 15:33 and 17:15 you can see that the discharge is off. This is when he has the 0.4V drop and no current flowing. Then, he increases the voltage and you can see when current starts flowing, discharge is on - e.g. at 14:05. This is where the BMS enabled the discharge.

  • @Zorlig
    @Zorlig 3 года назад +3

    You have charging off... Your just comparing battery to charger voltage because they are still both tied at one end.

  • @dirkaust5107
    @dirkaust5107 3 года назад +1

    The voltage drop is lower when you switch on the Mosfets, try to Switch on the Mosfets and measure the voltage, it should fit. When the BMS switches off, there is No battery the Charge controller could charge. I think the BMS is acting normal

  • @jornbeckmann5697
    @jornbeckmann5697 3 года назад +6

    Servus Andi, @~11:00 I think, it's not strange at all, it's totally normal to see a voltage diff when all switches are open, you have both, charge and discharge, switched off at this point. The battery sits at a lower voltage than your power supply - and due to the open switches you see the voltage diff... And the increasing amps after you switched on the charging below the 1.5amps might be some kind of a soft-start, what do you think?

    • @philippk.5242
      @philippk.5242 3 года назад

      Totally right. Battery and supply are disconnected so they can have every voltage they want, when charge and discharge are disabled. But in the end you had it enabled. So this behavior seems not normal.

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +4

      @@philippk.5242 It is. He has discharge disabled. What he sees is the voltage drop over the internal Mosfet diode of the discharge Mosfets. At higher currents, the BMS will enable these discharge Mosfets to get rid of this drop (even when discharge is disabled). He should just keep discharge enabled as well. Remember, a BMS is a last line of defense, not a general switch for charger/load. The BMS does exactly what it is supposed to.

    • @diydsolar
      @diydsolar 3 года назад

      @@upnorthandpersonal 🤔

    • @philippk.5242
      @philippk.5242 3 года назад +1

      @@upnorthandpersonal at this sequence charge and discharge are off. So both voltages are more or less independent, no current flowing. Later in the video he had charge enabled.

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад

      @@philippk.5242 Yes, that's what I'm saying: later in the video he had charge enabled, not discharge.

  • @lanealucy
    @lanealucy 3 года назад

    Villeich ne Dioden Durchbruch Spannung/Strom?

  • @JR.M.S
    @JR.M.S 3 года назад +1

    Does the voltage drop matter in reality? What I mean is that if you run your solar setup with the JK BMS would this be a problem?

  • @rickpalmer9518
    @rickpalmer9518 3 года назад

    Ran into that before on many bms's and though bms was bad,however just do a quick discharge at high current and voila you will be at full voltage just PFM -normal

  • @mitchrothermel8157
    @mitchrothermel8157 3 года назад

    I guess you wouldn’t like my 6kw growatt inverter-charger it says the voltage is 1.1 volts higher than the battery!! I called about it and they said it’s fine the way it is. I guess on a positive note I can never over charge cause max charge voltage is 58.4😂.but my BMS doesn’t act like yours. Max difference through the BMS in or out is .03 at 50 amps either direction. I didn’t check at 100 amps though.
    Thanks for your thoughts

  • @landonferguson7282
    @landonferguson7282 3 года назад

    When the mosfets turn on, their resistance goes to only a few miliohms, allowing current to flow, and the voltage measures correctly. When the mosfets are off, the resistance across them goes up, which inhibits current flow, and makes a voltage drop.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      But why are they becoming conductive all of the sudden when increasing the voltage?

  • @philbrooke-little7082
    @philbrooke-little7082 3 года назад +1

    It was confusing to start with as you showed both charge and discharge switches off and so I was screaming at the video ‘what d you expect ffs?’ However watching further it seems you had actually turned on the charge one. I think the problem was that you had the discharge one turned off. This would not be a normal configuration and I suspect that things may well work if the discharge switch is switched on. In a situation of low voltage disconnect this will not be a problem for charging as charge voltage will be at least 0.6v above low voltage disconnect and so it will turn on and then, once the battery has reached low voltage reconnect, the discharge will be turned on and all will roses in the garden again.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      Hahaha, it's good my videos are causing reactions 😁
      Yeah, the disabled discharge was the problem as I show in the next video.

  • @PlanetCypher_
    @PlanetCypher_ 3 года назад

    So the .4V is the switch or forward voltage for the mosfet to latch? Does the qucc bms use bjt transistors? If so they are not reliant on a voltage to latch on as they use current and mosfet uses voltage to latch, seems like a design flaw¿?

    • @graemezimmer604
      @graemezimmer604 3 года назад

      FEts don't "latch". It depends if the controller is switching then on or not.

    • @PlanetCypher_
      @PlanetCypher_ 3 года назад

      @@graemezimmer604 agreed, sorry wrong word, hard switch is prob more accurate 👍

  • @anthonydequina2822
    @anthonydequina2822 Год назад

    were you able to fix or solve this problem?

  • @sjdtmv
    @sjdtmv 3 года назад +1

    sounds like a diode problem, a voltage drop of that size is normal when a diode is in series with voltage

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      Yeah, something like this. But why does it 'break' once we increase the voltage and it conducts then? Next video 😁

  • @extremeacc101
    @extremeacc101 3 года назад +1

    Keep up the excellent work Andy love your videos

  • @upnorthandpersonal
    @upnorthandpersonal 3 года назад +4

    What you're seeing is your discharge MOSFET (parasitic) diode voltage drop since you have discharging disabled.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад +1

      Yes, I know now. Thank you. Has been discussed in the community section already. I made a second video showing and explaining it 😊

  • @lesw8798
    @lesw8798 3 года назад +1

    Thanks Andy I love it when you poke your stick in the hornets nest, it gives me hours of entertainment!

  • @gd2329j
    @gd2329j 3 года назад

    Look like the drop across the meter !
    Disconnect just the BMS & see what 's on the DVM .

  • @andrewbowden1076
    @andrewbowden1076 3 года назад

    Andy you are testing two different power sources that are not connected together.
    For instance. You have a 16s battery that is at 48v and another 16s battery that is at 53v and they are connected but by the positive cable only and delete the thought of BMS. Now do the same test. You will have a delta of 5volts.
    Your .3v - .6 volt is the delta between

  • @MarcusPocus
    @MarcusPocus 3 года назад

    when you measure 0.3 to 0.6v.. that look batteries charged BMS in floating mode and when the BMS wake up, the charging mode is working fine.. or.. in your BMS settings, have you set a minimum working current around 1.5amp?

  • @TheGalifrey
    @TheGalifrey 3 года назад +4

    Andy, the battery is 55.6 and the charger is set at 56 volts with charging off, the positive of the charger is still connected so there is a 0.4v potential difference, with the charger running there will be no voltage drop, disconnect everything and measure resistance across the BMS it will read 0 which is no voltage drop. The voltage drop is non existent other than in your head due to a misunderstanding of potential difference. The only PD you're reading is the difference between the charger and the actual battery pack. If the PD was 0 then no current would flow. Voltage pushes current!

  • @ackmaniac5101
    @ackmaniac5101 Год назад

    Just enable "Discharging". What you see is the voltage drop of the Discharge Diode. When the BMS detects that it charges with a higher current, it protects the discharging diodes from overheating by switching on "Discharging".
    Just repeat the test and enable "Discharging" at all times, and you will see that the voltage drop disappears.

  • @Suicid344
    @Suicid344 3 года назад +3

    Vollkommen normal. Da Netzteil und Akku nicht miteinander verbunden sind, wenn im BMS Charge und discharge Off sind, siehst du einmal die Batterie Spannung 55,63v und die Netzteilspannung 56v. Und da du mit dem Multimeter dazwischen misst, misst du nunmal die Differenz. Technisch absolut richtig 👍🏻
    Ersetze BMS durch einfachen Ausschalter und du hast das gleiche Verhalten.

  • @davedave6404
    @davedave6404 3 года назад +1

    This is an interesting experiment, as is everything that Andy does. It is certain that there are differences in fine detail on the designs. This 0.4V drop is that of a diode across a MOSFET, some internal current draw. PD and EMF come into the equation here as well. The point when the MOSFET(s) conduct is clear. In practise the unit is working, it is interesting though to see the differences between products in such fine detail. I am sure the unit is not faulty though. Whether Andy can use these in his particular installation with 2 banks of batteries and different BMS and charge controllers will be determined by further experiments. Great U-Tube educational channel, you don't get this stuff on the BBC do we?

  • @joakimrehn1544
    @joakimrehn1544 3 года назад +1

    Since charge/discharge is both off you are measuring two different sources. Battery - Charger = your diff. Not strange at all.

  • @offgridwanabe
    @offgridwanabe 3 года назад +2

    What is the current on the 16 wire which supplies power to the bms?

    • @marcosmercado5648
      @marcosmercado5648 3 года назад +1

      Yes, yes, the S16 wire!!!??? This is the one who powers the BMS processor and Bluetooth, I guess?

    • @babaluto
      @babaluto 3 года назад

      @@marcosmercado5648 I recall the instructions calling for external BMS power source under some conditions suh as a lower voltage pack. May be going external in this config would resolve this.

  • @JimmyLLL
    @JimmyLLL 3 года назад

    Good solar charge controllers that don't use separate voltage sense cables should have voltage calibration.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      Never seen one with voltage calibration? Which one has that?
      It would not make sense to offset the voltage in the SCC. The voltage drop to the battery is dependent of your cables and amps.

    • @JimmyLLL
      @JimmyLLL 3 года назад +1

      @@OffGridGarageAustralia My midnite classic has voltage calibration for both battery and the pv. My old Plasmatronics had separate battery voltage sense cables.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      @@JimmyLLL cool thanks for sharing. Never heard about such a feature in a SCC...

    • @JimmyLLL
      @JimmyLLL 3 года назад

      @@OffGridGarageAustralia No problem. The classic is an excellent charge controller. Been running my house entirely since 2012.

  • @rcinfla9017
    @rcinfla9017 3 года назад +2

    Not a problem. It is normal When you have discharge turned off one of the back to back MOSFET's is turned off to prevent discharging. Charging is on which keeps one of the back to back MOSFET's on.
    The body diode of the turned off MOSFET will give you the voltage drop.
    When both back to back MOSFET's are on you get little voltage drop across BMS. This is the normal operation. Only when there is undervoltage cutout would the situation you manually invoked will occur. This only allows a lower charge rate because of the heat created by the body diode drop. This is only during LV cutoff and will allow full charge current again when cell voltage rises above reset LV cutout in normal operation and both back to back MOSFET's turn back on.
    There is not a problem only that they gave you the control to go and manually shut off discharge. This is not a normal manual control on most BMS's. They also gave you manual ability to turn both charge and discharge off so there will be voltage drop across BMS of any amount. This state would normally only occur in normal operation if an over temperature and maybe overcurrent cutoff occurs. Overcurrent discharge cutoff may keep charging ability. Overcurrent charge may shut off both directions.
    They have an extra single MOSFET with a power resistor in series at end of MOSFET string on PCB. This may be the low voltage cutoff charging path or path to avoid startup surge current.

  • @ShenZhenDigiCasting
    @ShenZhenDigiCasting 3 года назад

    up to 96S LFP and NMC BMS

  • @dmeyer8937
    @dmeyer8937 3 года назад +2

    If you have no current flowing then you have no voltage drop - but you do have a voltage difference between voltage sources. You have the power supply + connected to the battery +. You have isolated the battery supply (-) from the power supply (-) by turning off the mosfets in your bms. If you disconnect the wire from the power supply (-) and read the voltage across P- and B- of your BMS I bet it says 0.00, zilch, nada. Keeping the wire diconnected and reading from battery (-) to power supply (-) you will probably still see your voltage difference.

    • @andreyrules4ever
      @andreyrules4ever 3 года назад

      Exactly my thought.

    • @babaluto
      @babaluto 3 года назад

      Well that's just P•I•E in your face. Makes sense. Curious to see where this goes.

  • @1978jra
    @1978jra 3 года назад

    Is it the bodydiode of the mosfet?

    • @1978jra
      @1978jra 3 года назад

      Was the discharge off all the time?

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +5

      @@1978jra yep - that's the issue.

  • @ruim8954
    @ruim8954 Год назад

    I have a B2A8S20P with self power consumption 65Ma@12,25v 0,8w with all disconnect and functions disabled, JK false advertised as having standby function. Only on off available for bms. I don't want discharge my battery. This is a big problem!

  • @mcdonaldt100
    @mcdonaldt100 3 года назад

    My Daly BMS has the exact same thing

  • @GabrieleBertaina
    @GabrieleBertaina 3 года назад

    Looks like the extra voltage required to turn on the bms has some strange sort of correlation with this behaviour where volts drops are happening...
    Or is a sideeffect of the capacitor used in the balance function...?
    Probably over thinking, is just faulty...
    🤔

  • @Zorlig
    @Zorlig 3 года назад +1

    If you check his other post he figured it out two days ago, but still posted this video as is.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      Yes, the videos were already made so I share the information anyway for others to learn. Also watch the next video where I explain what happened.

  • @graemezimmer604
    @graemezimmer604 3 года назад

    The Voltage drop can't be caused by the FETs as they have incredibly low series resistance when on.
    For some reason the BMS is not turning on the FETs.
    My guess is that the BMS will isolate the batteries until it is sure that the supply is high enough to begin charging, because it can't measure current until significant current is actually flowing. So instead it measures Voltage, then switches on the FETs when the current is sufficient to measure.
    Another possibility is that to save energy, it is in "sleep mode" until there is significant forward or reverse voltage difference.
    A simpler explanation is that you have charging switched off.

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +1

      His discharge MOSFETs are turned off - that's why (later part in the video, charging is on, discharging off). The BMS turns these on (even if you have it turned off in the app) once enough charge current flows. The closed discharge MOSFETs act as a diode (parasitic diode in a MOSFET) and causes the voltage drop. It will still prevent the battery from discharging once the current drops as per the settings. If he had enabled discharging in the app, he wouldn't have seen this. The BMS is operating normally.

  • @windpowered7771
    @windpowered7771 3 года назад +5

    You take comments down from people who actually know what there doing

  • @Portcall1
    @Portcall1 Месяц назад

    Hi,
    I need help! I bought a small sailing boat with JK BMS installed. The previous owner changed the password. I need to reset it, but after several attemps asking the manufacturer (they do not repond) I looked on thew internet and found you. Can you help me out?
    That would be very nice if you can, thanks in advance Portcall

  • @tronor5
    @tronor5 3 года назад

    I have a jk only Balancer and it shows 0.4 v more than my BMS and if i measure manually same result (so jk) had to adapt to that !

  • @philippgraf4589
    @philippgraf4589 3 года назад

    Also bei meinem Dali bms ist kein Spannungsfall mes bar und ich verstehe deine Probleme mit dem Dali bms ich muss aber sagen ich bin zufrieden damit und finde auch mosfets bms besser da die kontakte nicht zusammen geschweißt werden können

  • @launacorp
    @launacorp 3 года назад +1

    Wer misst, misst mist 😉

  • @jomilkman580
    @jomilkman580 3 года назад

    This might be a silly question but I'm unable to find a contract number for victron I am unable to login to my victron VRM account and I have not been able to access my account for almost a year now were can I find a number to talk with someone from victron that maybe able to assist me in gaining access to my account again also the reason I can't login is I recive an sms when I log in and well that sim card got damaged hope you may be able to help

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      I would reset the password here: vrm.victronenergy.com/login
      Or I googled 'victron contact'
      www.victronenergy.com/contact

    • @jomilkman580
      @jomilkman580 3 года назад +1

      I have done the rest password multiple times but I can't do it as the mobile number I will receive I code to allow me to reset my password because I enabled second step verification and yeah since I lost the ability to receive text messages codes I even created a new account but I'm not able to link any of my gear because it's already linked to my account I can't access but I'll try to call the number in the Netherlands again I'm sure there is a way

  • @vaneay
    @vaneay 3 года назад

    this is normal it's the body diode of the mossfet , when the body diode reverse voltage trip 0.6v a circuit trigger the mosfet to bypass the body diode in order to not dissipate power inside the diode

  • @jerzol_KOMINIARZ
    @jerzol_KOMINIARZ 2 года назад

    W JK BMS masz kondensator który pracując pobiera lub oddaje prąd :-))

  • @babaluto
    @babaluto 3 года назад

    Is the KY internally or externally powered in your config?

    • @pmacgowan
      @pmacgowan 3 года назад

      Nothing like internally powered KY, makes the wife happy!

    • @babaluto
      @babaluto 3 года назад

      @@pmacgowan HeHe, you got that, did ya?

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      you guys 🤦‍♂️😁

  • @andrewbowden1076
    @andrewbowden1076 3 года назад +3

    Your test on the Daly was not the same just to be fair. You did not have the the charge and discharge off on the Daly.

    • @OffGridGarageAustralia
      @OffGridGarageAustralia  3 года назад

      I didn't pay attention to this setting and will do the Daly test again.

    • @andrewbowden1076
      @andrewbowden1076 3 года назад

      @@OffGridGarageAustralia no reason to. The test will be that same as the jk

  • @markspieth7591
    @markspieth7591 3 года назад +1

    The difference between the relay BMS and the MOSFET BMS is that you have a sense wire on the BMS side of the relay which is effectively your battery voltage. You do not have this sense wire with the JK BMS. What you have described is ohms law. Infinite resistance (MOSFET or relay off because BMS charge is off) means no current and the potential difference (voltage) is the voltage difference between the battery and the charger voltage. Exactly what you see and what is EXPECTED.

  • @KevIsOffGrid
    @KevIsOffGrid 3 года назад

    My 'FET based BMS doesn't do that ....

  • @igorkvachun3572
    @igorkvachun3572 3 года назад

    Yes 👍 🔌 🔋 ⚡ 💡

  • @uhjyuff2095
    @uhjyuff2095 3 года назад +1

    The BMS is not perfect, but it does have active balancing!

  • @andreyrules4ever
    @andreyrules4ever 3 года назад +1

    I think what you are measuring without current flowing is the difference between the battery and the supply.... the voltage would still be there even without the BMS inline.... starting the charging on the BMS and measuring the drop across the BMS, shows what the drop on the MOSFETS really is.... and it really is 3-4mV...
    Think about this: you have a light and a light switch in series, powered by the grid voltage. with the switch ON, you measure 230V across the light bulb and zero volts across the switch.... With the switch OFF, you measure 230V across the switch, and zero across the lightbulb....

    • @andreyrules4ever
      @andreyrules4ever 3 года назад

      But still a strange behaviour of the BMS turning on so late, and building half a volt across.... Curious, I wonder if that is intentional or a mistake on their behalf...

    • @upnorthandpersonal
      @upnorthandpersonal 3 года назад +3

      @@andreyrules4ever It's Andy's mistake: he has discharge disabled. He's measuring the voltage drop over the internal (parasitic) diode of the discharge mosfets at low current. At higher current, the BMS activates the discharge mosfets (even if you have this disabled) to get rid of this drop.

    • @andreyrules4ever
      @andreyrules4ever 3 года назад

      @@upnorthandpersonal Exactly, it makes perfect sense.

  • @ab_ab_c
    @ab_ab_c 3 года назад +1

    You are measuring a voltage difference of .4V across your BMS, but the supply/charge current is 0A. That is odd. It makes me think the BMS is possibly getting current from the batt or from it's supercap/s. One way to answer that question is to measure the current between the batt & the BMS & also between the supply/charger to the BMS to see if current is moving from either potential energy source to the BMS. If you see no current flowing from either direction to the BMS, then the BMS is supplying the current or the output circuitry of the BMS is leaking a bit of energy some how...
    So your BMS cuts-off in batt bulk charging mode .4 V lower than your supply/charger V. Why is that a big deal? If you want it to reach cut-off at the same V as your supply/charger V, then raise the BMS cut-off to .4 V higher than it is currently set. Won't that work? I'd consider that 'problem' as a safety feature if I was you.