Design of Underground Water tank using Robot Structural Analysis

Поделиться
HTML-код
  • Опубликовано: 22 авг 2024
  • "This video explains steps and procedure to Design of Underground Water tank using Robot Structural Analysis.
    For other related videos:
    -Design of Slab with Openings using Robot Structural Analysis: • Design of Slab with Op...
    -Design of Pile cap using Robot Structure Analysis: • Design of Pile cap usi...
    -Design of shallow foundation using Robot Structure Analysis: • Design of shallow foun...
    -Substation Civil and Structure: • Substation Civil and S...
    -Design requirement for Substation Civil & Structure: • Design requirement for... "

Комментарии • 11

  • @statutesandordinances5155
    @statutesandordinances5155 9 месяцев назад +1

    Great video, thank you for sharing.

  • @klefaklefa2828
    @klefaklefa2828 Год назад +2

    thanks for you but where is the effect of filled soil on the walls the crticale case is when the tank empty and thers only soil effect.

    • @annaiteresaec
      @annaiteresaec  Год назад +1

      Hi, Thanks for watching the video and thanks for your comments. Yes, correct.. Water tank to be checked for 2 major cases. One: when tank is empty & soil pressure exist and Two: when tank is full no soil pressure. For time constrain to limit video duration less than 30min, some real time loads are not performed. Soil pressure can be also applied by Considering GA (density) value as 1800-2100kg/m3 in load table as hydrostatic pressure, Also if surcharge pressure to be applied, the same can be added as load type: 'surface on object' in load table.

  • @statutesandordinances5155
    @statutesandordinances5155 8 месяцев назад +1

    Hello, will the selfweight of the water not be acting on the floor?

    • @annaiteresaec
      @annaiteresaec  8 месяцев назад

      Yes. Two scenarios. One when the tank is empty and Soil pressure. Another is tank is full no soil pressure. In the second scenario need to consider water density. But, considering water weight on slab will not give better results, as net upward pressure get reduced, when tank is full. Better, We can ignore water weight for UG and on ground tanks on floor slab desing.

  • @carlosbgon
    @carlosbgon 7 месяцев назад

    Hi,
    Can you revise my water tank model? Best regards from Portugal

    • @annaiteresaec
      @annaiteresaec  7 месяцев назад

      Sorry, no. We are not having sufficient time for this support.

    • @carlosbgon
      @carlosbgon 7 месяцев назад

      @@annaiteresaec ok, no problem.
      If you know someone with knowledge to do some robot jobs , tell me

  • @timothykyalo9794
    @timothykyalo9794 11 месяцев назад

    top slab not included/soil pressure not included

    • @annaiteresaec
      @annaiteresaec  9 месяцев назад

      Soil pressure can be considered same as hydrostatic loads only change is density and direction of loads. Top slab are designed is separate video with openings: ruclips.net/video/ZmDI7V18tnE/видео.html