per aghar aap ki saat reinforcment bar ki length kum ho rahi ho tu ap building wire ki zarye ap ne jo joint lagai ha wo tu aap ak hi line ma lagai ha unfortunatly in earth quake your bottom mash will be disturb so the result is your structure of building is also distrub if i right so please noted this imported point
Bhaiya jee you tube channel PE video bana rahe achhi bat Hain lekin kabhi I S CODE bhi reading karna chahiye aapko malum hain aap kitne technical mistake Kiya Hain collumn lap alternate hona chahiye or raft and footing main hamesha long spen main bar hona chahiye short span distribution bar , raft top main bar and distribution bar short span (3 layer ) hona chahiye . Steel lap ke liye hamesha 1:6 ratio crank hona chahiye or aapne raft steel lap kaise kiya hain ek dekhiye...... Ek engineer or ek foreman main Kiya difference Hain .
sir, you are Great....Thank you.. really really Good knowledge with great explanation
Such a clear full knowledge of raft foundation i got bro.......thanku so bro....waiting for videos like this
thank you very much brother... your video was very understandable. thanks for your service.
This video very helpful to me cracking my exam I really appreciate you for making such a nice video.....
Yar yi main bar avr distribution reinforcement kis Tarah dalty hay
congratulations.................................. super
zabadast yaar keep it up
Good share
What is the area of this raft? Total steel ? And labours and steel fixer es required for this raft foundation.
Very informative video, do continue this series.
Sir ji raft footing se kitna storey house bana sakte h.
Excellent keep it up ♥️
Just one word fabulous
Very helpful 👍
Good job 👍
Explanation in English will help every one
Nice info. Thx
per aghar aap ki saat reinforcment bar ki length kum ho rahi ho tu ap building wire ki zarye ap ne jo joint lagai ha wo tu aap ak hi line ma lagai ha unfortunatly in earth quake your bottom mash will be disturb so the result is your structure of building is also distrub if i right so please noted this imported point
Very help full
Very big structure, thank you for showing it.
Good job
Good one. Thanks
How you prepared a uniform soil bed for p.c.c
Thank you sir i like this video
Could you tell me what type of column is there one with reinforcement within the column?
Column steel bars are in parallel not in ulternative for overlapping area
Hi
May I ask for how many storied building this Foundation is prepared?
And what is the soil condition here?
TIA
Can we use this fou dation type in house building
Grid line kia hoti hay..??
Excellent job. I wish i could afford to employ you to do my job in ghana
Did u understand his language?
@@prawingajbhiye8816 I didn't lol but based on the job done that's why I said that. Lol
Nice lecture
where we have to provide lapping in top and bottom reinforcement in raft (lapping position)??
May i know this rainforcement is for howmany stair 🏢
What the size of bar that used ?
Good
why havent we provided extra bars for column ??
Bhaiya jee you tube channel PE video bana rahe achhi bat Hain lekin kabhi I S CODE bhi reading karna chahiye aapko malum hain aap kitne technical mistake Kiya Hain collumn lap alternate hona chahiye or raft and footing main hamesha long spen main bar hona chahiye short span distribution bar , raft top main bar and distribution bar short span (3 layer ) hona chahiye . Steel lap ke liye hamesha 1:6 ratio crank hona chahiye or aapne raft steel lap kaise kiya hain ek dekhiye...... Ek engineer or ek foreman main Kiya difference Hain .
रफ रफ फौंडेशन में जी प्लस टू मकान बनाने में कितना खर्चा पड़ेगा पर 1000 स्क्वायर फीट में
Good job sir
Ye kitne manzil Ka hai rod size puller size beam size stair details bataie
Make more videos plz it's very helpful
Thanks so much sir
Sir iska Bbs Kaise Nikalte hai
Nice
Nice vidio
Thank you sir
Civil society
Good video but dimensions should be kept proper as in column L u said 30 milli instead of 300 mili ;)
With topmat also
In foundation main reinforcement have to provide in long direction, so it will be botom- bottom and top- top
In bottom mat main reinforcement should be provided in bottom and in top mat it will be in top....
Work in oman
U said main reinforcement should lie in shorter dir. But it is wrong. For flat raft main reinforcement should lie along longer direction
Good
Ap pedestal colum ko bol rahy ho..??
Location of Site?
Below the column the raft bottom bar has been lapped .. it's actually wrong !. There is max. BM
Hello brother
👍
I need it's drawings plz
work in Oman
Please sir can you forward me pdf of raft drawing
Sure, I would be happy to do this for you.....
Please Share Your Mail Details....
@@civilengineersitework6460 sayedkhalid.kazi@gmail.com it's my email id
@@sayedkhalidkazi6034 Please Do Check Your Mail...
use english pls😢
sir, you are Great....Thank you.. really really Good knowledge with great explanation
good