Duct Design for Great Results w/ Ed Janowiak (ACCA)

Поделиться
HTML-код
  • Опубликовано: 21 ноя 2024

Комментарии • 94

  • @neilcomparetto5282
    @neilcomparetto5282 3 года назад +64

    HVAC School and chill tonight.

  • @robertb1138
    @robertb1138 2 года назад +19

    For him to finally get to explaining a basic concept like static pressure at the *36 minute* mark means this video could be 75% shorter. But maybe he charges by the hour.

  • @a.t.7021
    @a.t.7021 3 года назад +18

    Bryan, I appreciate the effort to provide us with duct design training but I"m certain there's a much simpler way of doing it. Some years ago I took a duct design course at the local college for two semesters, it was properly presented and easier to absorb which I appreciated. I appreciate all you do for us and hope you take this as constructive criticism. Thank you....

    • @ATeamAdam
      @ATeamAdam 3 года назад +4

      You could set your ductulator at .1". Or you could do it right. 🤔

    • @HVACRTECH-83
      @HVACRTECH-83 Год назад

      This guy is too full of himself to be a teacher anyone would respect. Guys like him are a major problem in the trades. Cocky,arrogant, worse words come to mind but I'll be nice on here. And he's not rite with all he said here either. But you won't be able to convince his type. It's a shame really

  • @휘센0187
    @휘센0187 2 года назад

    I am Korean
    I am always studying, there are many good contents, thank you always

  • @brianporter4352
    @brianporter4352 3 года назад +5

    When I lived in NJ, I attended a class that Ed taught in Mt Laurel. It was an air flow class. The first thing he said was "guys it's all about air flow" If the air flow is not right, then your charge will not be either. Very true, especially with the crappy duct systems we see in new construction.

    • @craigprice-fq2vm
      @craigprice-fq2vm Год назад

      CFM?

    • @Clamjammer
      @Clamjammer 10 дней назад

      At johnstone? Maybe we were in the same class😂

    • @brianporter4352
      @brianporter4352 8 дней назад

      @@Clamjammer I'm not sure if it was at Johnstone or not. This was through EHCC, and I think it was at their campus.

  • @Bigmandoloco
    @Bigmandoloco Год назад +1

    13:21 is where he says, THATS ENOUGH!

  • @GregariousAntithesis
    @GregariousAntithesis 3 года назад +3

    I simply use 1 cfm per sq foot and size my room duct size based on that simple math and it works out golden. Did the static tests and right on the money. Granted it was all metal duct no flex. Reality is doing all the calculations makes more sense on complex larger systems to get everything well balanced but fact is it is your usually rounding up because calculations usually are between sizes often so there is no perfection in design no matter how complex the calculations. Willing to bet there is a common factor that could be used based on a few typical conditions that you use as a multiplier that will get you every bit as close. Most of the frictional loss factors are just that anyway.

  • @love2hvac
    @love2hvac 3 года назад +5

    I was in that class! Great job Ed

    • @MJ-iy4fb
      @MJ-iy4fb 3 года назад +1

      How much longer are your school vid's going to be up?

    • @love2hvac
      @love2hvac 3 года назад +1

      @@MJ-iy4fb most of the classroom videos will be taken down this weekend. I may blur out a couple and link the the replacement.
      There is a school in town that will allow me to do some filming so I can recreate some others.

    • @mikeautostudent5562
      @mikeautostudent5562 3 года назад +1

      @@love2hvac is there anyway that you can leave the audio portion of the classes? Because it sounds like a prodcast.

  • @billcowhig5739
    @billcowhig5739 3 года назад +6

    Thank you for the review of ACCA Manual D, and for exposing the hard to find fact that TESP = ESP. If contractors actually use Manual D to design residential duct systems and retrofits, why do studies find that the majority of them are deficient? Do inspectors require acceptance tests of any kind designed to protect ignorant homeowners?

  • @johnnyprotalk3352
    @johnnyprotalk3352 2 года назад +1

    i enjoy your classes and now your videos

  • @SuperVstech
    @SuperVstech 3 года назад +2

    I love the ACCA ductulator app for iPad.

  • @MJ-iy4fb
    @MJ-iy4fb 3 года назад +1

    Nice video. Always a quality show.

  • @garysmith9772
    @garysmith9772 3 года назад +7

    Well that was about as clear as mud

  • @hum2020
    @hum2020 3 года назад +3

    Thank goodness for ductless ac.

  • @organicvids
    @organicvids 2 года назад

    funny thing, i reworked my hvac vents, removed the. yellow and pink hydroscopic garbage, sealed ALL connections with mastic and covered that with hytech ceramic additive mixed with rustoleum elastomeric roof paint then covered it with refectix. above my intake is a 12" pipe which leads tp hot water heater room which has a 25 inch vent with filter adjacent to fridge. both the heat from fridge and hot water heater are fed above intake on hvac. i run evergreen ecm 24/7 for filtration with merv 13, april air, and electrostatic prefilter with ecm 80cfm fresh air intake plumbed directly into furnace intake hooked up to filter box outside with 3 electrostaic prefilters. 5 uv lights. one in center of coil, one on each side and two on top with mirrors in coil housing to reflect uv light back into coil and set to timers. condensation line has cost guard pressurized drain with scupper valve. crawlspace is partially conditioned with no insulation in floor, a dehumidifier set to 50 with humidistat and temp gauge under home. temp gauge and humidistat after coil before main duct supply. not much more to do but get broans integrated system to run house exaust fan when fresh air fan is running, and a whole home dehumidifier like the santa fe which would dehumidify fresh air intake.

    • @adb99999999999
      @adb99999999999 2 года назад

      needs a few more uv lights

    • @organicvids
      @organicvids 2 года назад

      @@adb99999999999 yes in main duct line just one because of higher humidity levels whe using ac.

  • @Chris-uh3cm
    @Chris-uh3cm 2 года назад

    Thank you for the video and the awesome video description

  • @hvacdesignsolutions
    @hvacdesignsolutions 2 года назад +6

    If residential duct design is so easy, why do so many installers screw it up.

  • @sportsman042002
    @sportsman042002 3 года назад +2

    Man a lot of good info very thankful!

  • @AF-O6
    @AF-O6 5 месяцев назад +1

    So what you’re saying is, fab a big ass sloppy plenum out of duct board, and use a run of flex duct to a register in each room. Size the system 2 tons larger than required to keep the customer happy. Oversized ductapuss for the win…quick, dirty, and off to the next job.

  • @rickl5938
    @rickl5938 Год назад

    Wonderful video. Thank you for presenting this. Here's my question: Does the return air grille have to serve (get supply air from) the register that is in the critical airflow path for it to be considered in the critical air flow path? Obviously, this only applies to multiple return systems. Thank you.

  • @garbo8962
    @garbo8962 3 года назад +1

    Wish I had a dollar for houses and commercial sites that contractor cut corners installing undersized duct. Went round & round after installing a VFD for a 100 HP air handler. Could not run motor over 88 to 90% of full speed or motor would draw too much current. Problem went away when door on both sides of fan were tied open. Worst part the undersized duct ran up 6 floors to mechanical room. Just great on cold days when they only run 100' of duct in a 300" long room.

  • @hozerhvac4406
    @hozerhvac4406 2 года назад

    Great lesson. I needed this.

  • @joegood2474
    @joegood2474 Год назад

    All good information but the truth is unless someone is designing very complicated heavy commercial or industrial duct systems or some type of critical installation, no one that does this for a living goes through all these steps to install a 'home' duct system. The best systems for homes are home-run systems because velocity always stays the same and all you need to do is size the duct for volume, but they do need to be installed before ceilings.

  • @HVAC544
    @HVAC544 3 года назад +1

    Some of the fittings on manual D are really hard to tell what they are based on the pictures.

  • @johnnyprotalk3352
    @johnnyprotalk3352 Год назад

    awesome infomation

  • @wuldntuliktonoptb6861
    @wuldntuliktonoptb6861 9 месяцев назад

    Yea I remember after sandy up in Rhode Island they had to bring in payloaders to shovel the beach off the road and put it back like at the water line of the ocean lol.

  • @KyleRicciardi
    @KyleRicciardi 3 года назад +5

    Judging from the comments we got quite a few that fit in the "80% don't do this".

  • @PTF491
    @PTF491 3 года назад +2

    how do two stage system affect your minimum velocity requirement?

  • @davidwilliams9739
    @davidwilliams9739 3 года назад

    If I got an online now can I upgrade it to a symposium before Feb.

  • @ishalljr
    @ishalljr 3 года назад +1

    Thanks. Dropbox info?

  • @elgringoec
    @elgringoec 2 года назад

    😂 I'm three minutes in and right away I'm relating - I also have a piece of yarn on a grille so I can verify air is flowing and I also set my cooling temp to 76.

  • @johnnyprotalk3352
    @johnnyprotalk3352 Год назад +1

    just wish you went over cfm needed for each room... im alittle confused for that part

    • @erikcable1755
      @erikcable1755 10 месяцев назад

      sq feet 8foot ceiling...cfm. 10x10 room, 6 inch

  • @JB-yq9bn
    @JB-yq9bn Год назад +1

    Notice acca fittings never assume a horizontal attic install. They also heavily penalize round tee wyes. How many rivers do you see with a bull head tee and only 90 degree takeoffs? I think ACCA's bias comes across in the TEL data.

  • @balint133
    @balint133 3 года назад +24

    This could have been an hour shorter if the guy would've stopped talking about irrelevant staff all the time.

    • @edwardjanowiak
      @edwardjanowiak 3 года назад +9

      If it wasn't for the staff, there wouldn’t have been an event, it’s mine boggling that you would call them irrelevant 🤷🏽‍♀️.

  • @jesuscastillo1083
    @jesuscastillo1083 Год назад +1

    May be he’s got a part time as a comedian

  • @dakota4766
    @dakota4766 2 года назад +1

    its a bummer that he skips explaining fitting tel especially group 2. other than that so much good information

  • @anthonybrown9832
    @anthonybrown9832 3 года назад +8

    Bryan thanks for the vid,but please learn how to edit these types of videos. This guy is hard to listen to,full of nothing stories that we all have in the field.

  • @alvarovictoria1690
    @alvarovictoria1690 6 месяцев назад

    Good afternoon could you tell me please where can I get (buy) flex duct calculator ruler

  • @simonfong321
    @simonfong321 2 года назад

    Hello I have a duct system that has a 3" round duct that I want to convert to 3.25 x 10" rectangular duct. But the top portion of the 3" is to the roof. I'd say 15-24" that I don't want to change due to the roof work. I'm running about 15' of rectangular duct. How bad is it if I convert the majority of the ductwork and leave the last 15-24"? My rangehood is a low CFM capacity. 180CFM max I believe. I know it's not ideal but how bad is this? I feel it's like fumbling at the 1yd line.... any advice good or bad would be helpful. Thx

  • @ghettohey2388
    @ghettohey2388 2 года назад

    Hi Im just the average person who would hire a hvac guy to design my system and put it in my home. I liked watching and listening to your class but didnt understand alot of it. My question to you ED is this. As a homeowner how or what do you suggest or recommend to know if your getting the right system put into your home and if the system that they put in puts out the numbers that it should. Last question. What advice do you suggest when searching for a hvac person to hire

    • @Garth2011
      @Garth2011 2 года назад

      At minimum, a HERS inspector will have some mild input on that. I believe all HVAC replacements require a HERS report which is supposed to evaluate the ducting and determine if they are installed/sized correct and do not leak more that 15% at connections.

    • @joegood2474
      @joegood2474 Год назад

      BBB - must be A+ and in business over 20 years.

  • @smacleod69
    @smacleod69 3 года назад

    Doing ductwork systems and change outs for over 20 years. Not many companies do this. When you only have a certain amount of time given to get the job done. You can go by the .1 static pressure to design your system. Go with .5 total esp from the furnace specs. you will be just fine.

    • @KyleRicciardi
      @KyleRicciardi 3 года назад +1

      Did you mean 0.1 friction rate?

    • @HVAC544
      @HVAC544 3 года назад +1

      .5 is really hard to hit on a furance and ac system. Most in the field seem to run around 0.7 to 0.8 external static

    • @smacleod69
      @smacleod69 3 года назад

      @@KyleRicciardi Nope. Static pressure determines cfm of air air flow in the system. You measure static pressure with a manometer, not friction rate.

    • @KyleRicciardi
      @KyleRicciardi 3 года назад

      @@smacleod69 friction rate is what you select on a duct slider. 0.1 friction rate is what your referring to when sizing the duct. Unless your using velocity? There is no "static pressure" on a duct slider

    • @smacleod69
      @smacleod69 3 года назад

      @@HVAC544 I can hit point .5 if I size duct work correctly. I can even hit .5 in a change out scenario by modifying r/a ducts like upsizing and/or adding a return. Using wide louvered r/a grills instead of standard grills. Also increase the size of some supply ducts or add one. And lastly, do an air flow balance can help.

  • @pepeshopping
    @pepeshopping 3 года назад +26

    Condense the knowledge. I don’t need jokes.

    • @nojiggle530
      @nojiggle530 Год назад +2

      Yah ed is a terrible teacher just rants and brags it's so sad we only have 2 people that know how to design duct

    • @HVACRTECH-83
      @HVACRTECH-83 Год назад +2

      Agree. This is an absolute waste of all of our time. I can't stand this arrogant guy. Wish bryan would stop using him. He's useless

    • @MrsChip
      @MrsChip 8 месяцев назад +1

      Come on, Ed’s good and I enjoy his presentation and find him humorous. Better than delivering material too dry.

    • @stephanguidry2178
      @stephanguidry2178 3 месяца назад

      Speak for yourself, entertaining and informative. I’m a fan

  • @edlauren9434
    @edlauren9434 3 года назад +12

    It’s difficult to listen to the screaming voice.

    • @torr5952
      @torr5952 3 года назад

      Agree :-)

    • @edlauren9434
      @edlauren9434 3 года назад

      :)

    • @farleyredfield3768
      @farleyredfield3768 Год назад

      Does anyone watch this and read the silly comments? The guy is doing what he does and letting us follow him through it. Everyone commenting negatively is a whiner

  • @monysok5343
    @monysok5343 2 года назад

    GOOD

  • @Garth2011
    @Garth2011 2 года назад

    I've seen a lot of homes get built, NO WAY those contractors bothered with this math or point of view. Especially those units that have the return grill 1 to 2 feet from the blower...they do that all of the time (or at least since the 1980's through the early 2000's they did).

  • @onlyulee866
    @onlyulee866 10 месяцев назад

    What happens if you oversize the duct and the unit has zone damper

    • @edwardjanowiak
      @edwardjanowiak 10 месяцев назад

      As long as the supply outlet, register selection is proper, oversizing a duct and reducing velocity is not a problem. If you’re not controlling your branch run volume, who knows what’s gonna happen ( probably won’t be good).

  • @andysmith5940
    @andysmith5940 11 месяцев назад

    about 15 minutes of good content and 2 hours of shooting the breeze. very frustrating

  • @darrinscoilsclouds1498
    @darrinscoilsclouds1498 2 года назад

    Too much chitchat. Moving on.

  • @ATeamAdam
    @ATeamAdam 3 года назад

    You said ductulator

  • @damon6852
    @damon6852 3 года назад +2

    Well, this presenter has his comedic timing down, and I enjoyed this for that…but did I learn much…no

  • @tabithafranklin8750
    @tabithafranklin8750 3 года назад +6

    What is this? A Joke? The dude takes FOREVER to get to the point!

  • @bernardinovilla2255
    @bernardinovilla2255 Месяц назад

    These teacher reminds me my college teacher that spend most of the class talking about how dumb was his wife and very little of hvac content. Me in the other hand, I had to drive for 45 minutes to get to the class, stopped work earlier for class and pay my tuition for all of this crap!!

  • @331whf9
    @331whf9 2 года назад +2

    Why all the small talk? This guy wana be a comedian?

  • @darkflux
    @darkflux Год назад

    i feel like this class could have been about an hour if you cut out all the jokes and personal trivia.
    a handful of jokes once in a while keeps peoples' attention. a constant stream of jokes just distracts attention from your class.

  • @tealkerberus748
    @tealkerberus748 8 месяцев назад

    Bruh I'm six minutes into this vid and I didn't come here to listen to you talk about your uncle. Do you get to the point?

  • @andrewattia5882
    @andrewattia5882 Год назад

    Borderline useless video, just be aware