Plumbing DWV & Supply Pressure Tests are Critical

Поделиться
HTML-код
  • Опубликовано: 12 авг 2023
  • Come along as I go into a residential Plumbing DWV (Drainage, Waste, Vent) and Supply Pressure Test.#inspection #residential #plumbing #drainagepipes #water

Комментарии • 23

  • @greggclaussen
    @greggclaussen 10 месяцев назад +1

    You're always informative. Thanks for the video

    • @PPG1967
      @PPG1967  10 месяцев назад +1

      I appreciate your support, and thanks for watching!!

  • @Deep_Divers
    @Deep_Divers 9 месяцев назад +1

    Thanks! I am ripping through all your videos. Reading the codes is one thing. Seeing it in the field is another. Very helpful when you not only point out the specific violation but where it applies elsewhere like you typically do. How about a video on plumbing cleanouts and where they are required?

    • @PPG1967
      @PPG1967  9 месяцев назад +1

      I appreciate the support $$$....thanks for watching.

  • @Lonzohiggins999
    @Lonzohiggins999 10 месяцев назад

    I'm about to get my inspection for a remodel thank you , very informative

    • @Lonzohiggins999
      @Lonzohiggins999 10 месяцев назад

      Quick question , how do you make it so that the water doesn't overflow through the showers since they're are below flood lever rim ?

    • @PPG1967
      @PPG1967  10 месяцев назад

      Plug or cap that shower drain.

  • @bartowens1860
    @bartowens1860 10 месяцев назад +1

    Good video, thanks for the information.

    • @PPG1967
      @PPG1967  10 месяцев назад

      I appreciate your feedback, and thanks for watching!!

  • @Downs96
    @Downs96 6 месяцев назад

    Here in Michigan, you cannot have 3” elbows horizontal to horizontal.

    • @PPG1967
      @PPG1967  6 месяцев назад

      What code book??

  • @constructivainspections
    @constructivainspections 10 месяцев назад +2

    I've never had the pleasure of shadowing a plumbing inspector so this is very informative. One question, just how far down the line is the ball placed in the drain line? And is there any test for the line beyond that, say, out to the street?

    • @PPG1967
      @PPG1967  10 месяцев назад

      It really depends on the layout. There's an underslab plumbing inspection if the house is on a slab, which is what you saw in the video. There's also a sewer lateral inspection. (Sewer connection to the street). To answer your question, a test plug is installed where the new drainage meets the existing.

  • @nobleroofinggeneralcontrac7961
    @nobleroofinggeneralcontrac7961 7 месяцев назад

    So if you have no water service to the building because you are waiting for the water department (construction held up) or it is winter..... cold temps. I would have concerns of testing with water you would never get all the water out of the lines unless you blew it out... . liner test yup great go ahead and sheetrock then during construction liner gets damage. I believe that all shower pans should be a copper pan with the brass drain soldered in.

    • @PPG1967
      @PPG1967  7 месяцев назад +1

      Normally, in the wintertime, we allow air.

  • @jwblount7802
    @jwblount7802 7 месяцев назад

    The irc/Ipc has a major contradiction when it comes to the plastic testing. Both say you cannot use air on plastic but 312.7 forces sewer test of the IPC requires 5 lbs of pressure greater than then working pressure of the pump. So the only way to do that is to air test it. Cannot use working water pressure that will creates a cross contamination situation..

    • @PPG1967
      @PPG1967  7 месяцев назад

      So, first of all, the plumbing section in the IRC is straight out of the IPC.
      Personally, I don't like air for any type of plumbing pressure test. It's easier to locate leaks with water

    • @PPG1967
      @PPG1967  7 месяцев назад

      The sewer drainage test required pressure can be achieved with a stack filled drainage system.

    • @jwblount7802
      @jwblount7802 7 месяцев назад

      @@PPG1967 How do you stack fill an 1 1/2" lift station pressure line 5lbs higher than the working pressure of a 25 lb pressure pump? Thats where that contradiction come into play.

    • @PPG1967
      @PPG1967  7 месяцев назад

      Ok, I misunderstood. You can use water or air with a forced sewer test.

    • @PPG1967
      @PPG1967  7 месяцев назад

      codes.iccsafe.org/s/IPC2015_NY/chapter-3-general-regulations/IPC2015-Ch03-Sec312.7

  • @nathanthomas4777
    @nathanthomas4777 9 месяцев назад

    Dirty arms are to long to the tee

    • @PPG1967
      @PPG1967  9 месяцев назад

      Huh???...for the size pipe (1-1/4") the maximum is 5'