EG4 6000XP with EG4 PowerPro Battery Part 2
My previous video is here:
ruclips.net/video/t1I8V5ONSnI/видео.html
In this video I am mainly discussing two settings on the inverter, setting 12 and setting 20 found in the manual.
Setting 12 deals with the end of discharge cutoff limit. I have this set to 30%.
Setting 20 deals with ECO mode enabled or disabled. I have it set to enabled, this allows for grid bypass mode when the battery reaches the discharge level as set in setting 12.
The purpose of this for me is so I can run on solar and battery for the critical load panel during most situations. During inclement weather when the panels can't charge the battery and I drain the battery, it will switch to bypass mode. When in bypass mode the...
Просмотров: 2 349

Видео

EG4 6000XP and EG4 PowerPro Battery Generator
Просмотров 11 тыс.7 месяцев назад
This build is intended to be a UPS and back up generator system for my critical load panel.  I am using the EG4 6000XP inverter and EG4 PowerPro battery. I purchased both from Signature Solar. I didn’t want to make this a “permanent installation” thus the cart. This cart construction is very sturdy. As mentioned in the video I purchased the 80/20 8080 type extrusion from Amazon and some from A...
Juiced Hyperscrambler 2 Hall Sensor Replacement
Просмотров 295Год назад
I was not able to find a RUclips video for replacing the hall sensors on the Juiced Hyperscrambler 2 motor. I received an error code 8 which is a hall sensor error on my display, after a few more hall errors the motor stopped working completely. I had to push the bike back to my house. The bike had 560 miles on it when this happened. I first tried a replacement controller and that did not fix t...
Lutron Caseta compatibility with RA2 Select (Powpak dimming module)
Просмотров 6852 года назад
In this video I show that a Lutron Powpak dimming module that’s compatible with higher end Lutron systems, such as RA2 Select and higher, can be controlled within the Caseta system to some degree. This Powpak dimming module shown in the video is not compatible with the Caseta hub and Lutron app ecosystem. However, I can still have the Pico remote and occupancy sensor control the Caseta devices...
LED T8 fluorescent tube modification
Просмотров 1,8 тыс.10 лет назад
This is a DIY project that takes about 15 minutes. LED fluorescent tubes are meant to be installed into a fluorescent fixture upon removal of the ballast so straight 110v goes into the LED tube. This video is a modification of the tube so I can plug an extension cord on one end of the tube to make it a light tube. These LED tubes are very light, with the power supply built in. This particular m...
Dad Playing Amazing Grace from June 2010
Просмотров 9810 лет назад
Chinese zither or guzheng (pronounced gujong)
Alaska Cabin foggy morning
Просмотров 14912 лет назад
A nice quiet foggy morning along the river in a remote part of Alaska
Judy's Trip to Orvieto (Civita) W/Church Bells
Просмотров 12112 лет назад
compilation of several short videos
Judy's Trip to Orvieto (Civita)
Просмотров 3412 лет назад
compilation of several short videos
Rakuten iPad2 Keyboard Case
Просмотров 19 тыс.12 лет назад
4-25-12 update: There is a killer keyboard on kickstarter. It's a bit pricey. I have nothing to do with it, I'm not peddling my own thing but check it out. www.kickstarter.com/projects/552506690/brydge-ipad-do-more I ordered this from Rakuten in Japan. I turns your iPad2 into a faux MacBook Air or Netbook. No trackpad for cursor control since iOS does not support that, you must use your finger ...
Zydeco Music
Просмотров 11 тыс.14 лет назад
Zydeco music at the Roots Music Festival in Fredericksburg Texas. Best band was Chubby Carrier and the Bayou Swamp Band, you also see Earl "washboard" Sally...great entertainer! This video was taken solely on my iPhone 3Gs
Bats Coming out
Просмотров 5514 лет назад
approximately 1 million bats coming out of an abandoned train tunnel near Fredericksburg Texas.
Joan Memorial pt 5 of 5
Просмотров 28815 лет назад
My sister Joan passed away after a battle with cancer on August 10, 2009. Joan Memorial Service in Fairbanks Part 5 of 5 Song: JOANIE IRENE All words and music by Leila Maria Johnson song is copyright control What will people say when Ive gone away, What will people say about me? Will they remember my smile, once Im gone for awhile, When they think of me what will they see? Will they see me in ...
Joan Memorial pt 4 of 5
Просмотров 8015 лет назад
My sister Joan passed away after a battle with cancer on August 10, 2009. Joan Memorial Service in Fairbanks Part 4 of 5
Joan Memorial pt 3 of 5
Просмотров 6315 лет назад
My sister Joan passed away after a battle with cancer on August 10, 2009. Joan Memorial Service in Fairbanks Part 3 of 5
Joan Memorial pt 2 of 5
Просмотров 12015 лет назад
Joan Memorial pt 2 of 5
Joan Memorial pt 1 of 5
Просмотров 17215 лет назад
Joan Memorial pt 1 of 5
Joan's last few days in Yuma, AZ
Просмотров 42815 лет назад
Joan's last few days in Yuma, AZ
Carina Playing Piano
Просмотров 43817 лет назад
Carina Playing Piano
NHRA drag racing pits
Просмотров 3 тыс.17 лет назад
NHRA drag racing pits
small plane taking off snow packed runway
Просмотров 3,1 тыс.17 лет назад
small plane taking off snow packed runway
Boat ride up river with McKinley in view
Просмотров 45217 лет назад
Boat ride up river with McKinley in view
Snowmachine on frozen creek
Просмотров 48917 лет назад
Snowmachine on frozen creek
mosquitos from mosquito magnet
Просмотров 12 тыс.17 лет назад
mosquitos from mosquito magnet
Alaska wilderness moose call
Просмотров 27 тыс.17 лет назад
Alaska wilderness moose call
Me Driving small boat
Просмотров 76617 лет назад
Me Driving small boat

Комментарии

  • @maddeusdoggeus1
    @maddeusdoggeus1 4 дня назад

    Outstanding Build! Thanks for sharing.

  • @PICOBULLY
    @PICOBULLY 11 дней назад

    When charging your batteries from the Grid do you use your inlet?

  • @d.pollard5962
    @d.pollard5962 17 дней назад

    Joe I am trying to put this together, size on 12x24 aluminum plate is actually 9"x21" and how do you attach the 2020 aluminum to the 8080. I am trying to get this built asap and I have all the parts. The wheels don't line up to the slots on the ones from automation direct. It is getting very frustrating as I am so close. Any help would be great. Thanks

    • @alaskajoe61
      @alaskajoe61 17 дней назад

      My aluminum plate is a true 12"x24" plate. For the attachment of the 2020 extrusion to 8080 extrusion I used two 90 deg brackets like this www.amazon.com/gp/product/B01H19M9VA/ref=ppx_yo_dt_b_search_asin_title?ie=UTF8&psc=1 Not sure if your casters are the same as mine. For me I was able to line up two holes with the slot in the extrusion and bolt it to the frame, the other two holes didn't line up with the slot in the extrusion. But that works for me to roll it around my garage, this is not meant to roll on a rough surface like a driveway or something like that.

    • @d.pollard5962
      @d.pollard5962 17 дней назад

      @@alaskajoe61 Thank you I appreciate the quick answer and help. So yes the wheels weren't lining up and I was going to do the same thing as you did, I ordered the 90 degree L brackets thank you for that explanation. Went today to buy M6 and M5 bolts and nuts as the M8 kit wasn't going through the wheels. The Cust Service at AD was nice but not helpful on the 12x24 aluminum sheet. I ordered what I searched which was a 12x24 plate but received a 9x21 inch piece of aluminum. I will call them Friday and try to resolve that. My build will have 2 batteries, A inside power pro ESS and a Ruixu lithi 2-16 14.3 kwh and 16 kwh respectively so 30.3 kwh of storage for $6288.00 $207.53 a kilowatt

  • @d.pollard5962
    @d.pollard5962 Месяц назад

    alright Joe everything is ordered and coming in now, wish me luck

  • @Slackware1995
    @Slackware1995 Месяц назад

    The 6000xp is rated for 240vac 25 amp as an inverter. BUT In AC or generator bypass mode it will supply 240vac 50 amp to the loads. The part I'm trying to figure out is how to limit ac (or generator) input amps. The reason being is that each 6000xp can do 50 amps in bypass while charging the batteries. This is potentially 75 amps (assuming max dc charging) which is a huge problem. The only solution I've figured out is to guess load amps, add a 20% buffer and convert the load into watts. Then take 240vac 50 amp input = 12,000 watts subtract the load watts. This gives you available watts for battery charging. Divide charging watts by 48vdc to get max charging amps and lower that by a few amps as an additional buffer. 6000xp's in parallel add to the complexity. Why they assume that 50 amps bypass is good for an inverter that only is rated for 25 amps is beyond me. 50 amps total ac input is almost reasonable. Why no option to set max ac input amps? I would assume most people would want max ac input to be the same as rated output, 25 amps. The 6000xp's inverter is rated 240vac 25 amps = 6000 watts. Presumably most people will design the max load to be under 6000 amps. Most common is either a single or dual 6000xp configuration. Dual allows for 240vac 50amp output, or 12,000 watts. Most people will set up a 240vac 50 amp breaker and cabling because larger is much more expensive and 50 amp is common due to RV's, generators and car chargers. 240vac 50amp service is enough for a small house or RV. i doubt there are a huge number of 5000 sq foot off grid houses. 12,000 watts is enough for a medium sized ac, hot water heater, washer/dryer, lights, tv, computer, and phone charging. Basically normal living in a 1000 sq foot off-grid house as long as you don't try to run everything at once. Or a "critical loads panel" for a larger house. For a single 6000xp, the expected max load is likely around 3500 watts (you don't want to run 6000 watts continuously). 20% buffer brings it to 4200 watts, 50 amp input means 7800 watts available for charging or 162.5 amps, maybe set ac charging to 150 amps. The trouble is dual 6000xp. Assuming max expected load of 7000 watts plus 20% buffer = 8400 watts. 50 amp input is 12,000 watts, leaving 3600 watts for battery charging. This limits you to 75 amps charging, maybe 70 amps to be safe. This is 35 amps per 6000xp. Even though you calculate 7000 max expected watts, what happens if the ac is running, your wife is cooking and someone takes a shower then dries their hair? A smallish ac will draw about 2000 watts, 1000 watts for a microwave or instapot, 1500-1700 watts for a hair dryer and 4000 watts for hot water heater (or 8000 watts if a long heater. We'll ignore other possible loads. This is 8500 watts. This is likely happening at night, so 3600 watts battery charging possible. 12,100 watts meaning the 50 amp breaker will trip in a few minutes. Worse yet, each 6000xp will happily bypass up to 50 amps. A dual 6000xp is spec'd to require 100 amps input (or more). By code you need a 120 amp breaker, except that isn't available, even 125 amp is rare. Meaning either 150 amp or 200 amp breaker. By code your cable must handle at least 20% more. Now you are paying for heavy duty cabling. Only a couple decades ago did it become common for houses to have 200 amp service, meaning most houses only have 100 amp service. Upgrading your house from 100 amp to 200 amp service is several thousand dollars. If someone buys 4 6000xp's in order to supply 100 amps to their house then they'll have to upgrade even more. Its all a never ending spiral. I can understand that some people want 50 amp bypass available. It should be an option, not default. The default should be 25 amps. This also partially explains the large generator requirements.

    • @Slackware1995
      @Slackware1995 Месяц назад

      I contacted Signature Solar tech support. Currently there is no way to limit either AC input, Generator, or even Bypass power. I requested that they send a feature request to EG4 to allow these limits. The more people that request features increases the chance that EG4 will implement them sooner. A 6000xp with it's 25 amp inverter should at the minimum allow a lower Bypass; 25 amp versus 50 amp. Even better would be to limit AC and/or Generator input to 25 amp. Best would be an option to allow the user to set their own limit possibly between 10 and 50 amps. I didn't think about requesting the ability to disable bypass mode. I can see a single 6000xp were you want to limit the AC input to 40 amp (80% of the maximum of a 50 amp breaker; considered a safe limit). I can also see a limit of 25 amp. And a lower limit becomes useful with multiple 6000xp. With two 6000xp you may want a 20 amp limit so that the total is 40 amp. EG4 recommends > 10kw generator for a single 6000xp. This us 41.67 amp, not enough for the 50 amp bypass (but likely enough for most people). Except for two 6000xp they recommend a > 15 kw generator. This is 62.5 amp, nowhere enough for the 100 amp Bypass. This means if you use the recommended size generator you first have to calculate the estimated AC load, plus a buffer, then limit the charging to not exceed the generator capability. Plus is you have loads the have high starting current, you may have to reduce charging even more. Generators are rated with peak power and running power. If you have a large AC or multiple AC units the compressor starting power (minus running power) may be more than the generator's difference between peak and running power. Then to add to the confusion, the setting for battery charging is DC amp. This means you must decide how many AC amps that you can use in bypass mode then multiply by 240vac to get power in Watts, then divide by charging volts to get charging DC amps, and finally adjust for effeciency. Even worse if your batteries are low the charging volts will be significantly lower than the charging volts that you set. This will result in different charging amps when the batteries are low versus when they are nearly full. As an example, your expected maximum AC load is 4000 Watts, which is 16.67 amps at 240vac. You decide to add 20% as a buffer which brings the AC load to 4800 Watts which is 20 amps at 240vac. You want to limit total input AC to 40 amps (on a 50 amp breaker). This allows another 4800 Watts for battery charging. If you use 54v to charge this would allow 88.9 amps DC. The claimed battery charging efficiency is 93%. This will lower your charging setting to 82.7 amps. But to be safe, you lower the maximum charging current to 80 amps, which is 4320 Watts charging, 4645 Watts consumption. This safely puts you under 40 amp 240vac input from the 50 amp breaker. You are happy! Except when evening comes and the AC unit(s) aren't running suddenly you AC load goes from 4000-4800 Watts to perhaps 1000-1800 Watts (with maybe short periods of increased usage, say your 1000w microwave). In this case your 6000xp doesn't say "I can charge the batteries faster!". You will still limit charging the batteries to 80 amp DC unless you manually change the DC charging amps and hope that you remember to lower it again before the AC unit(s) kick back on. If there was a setting to limit the AC input to 40 amps via a setting then if the 6000xp went into Bypass mode it will be limited to 40 amps, if your load is less then the rest could be used to charge the batteries up to a maximum of your charging limit. Everything would be automatic. If your AC load exceeds the maximum AC input then the 6000xp would fault to protect itself. A single 6000xp is relatively simple. It gets really complicated if you parallel multiple 6000xp's. The 50 amp Bypass mode is per 6000xp. 2 units is 100 amps (the old standard size house service) 3 units is 150 amps 4 units is 200 amps (the new standard size house service). 5 units is 250 amps etc This means that most older houses can only supply two 6000xp's assuming and newer houses can only supply four 6000xp's; assuming no other loads. Lets say you want to design a solar system to supply your old house. If you have a newer house you likely have 240vac 200 amp service from the electric company. This limits you to a maximum of four 6000xp's which can supply up to a combined 240vac 100 amps. For many people this is likely sufficient for now. But as you are forced into using more electricity (replacing natural gas stove, water heater, clothes dryer and furnace) and needing to charge at least 1 electric car you will often exceed 100 amps. Except to increase the number of 6000xp's you also need either to increase the service from the electric company which is a large cost OR configure only four 6000xp's with AC input, with additional 6000xp's off-grid. The second option has another issue that is unclear. The manual says all 6000xp's must be connected to your generator. The manual does NOT specify this for the AC input, but it's reasonable that if the generator requires it so does the AC input. EG4 needs to clarify this. If all 6000xp's must be connected to the AC input then you would need 2 seperate 6000xp systems, one connected to the grid and the other off-grid. Each system would have it's own bank of 6000xp's, it's own batteries, and it's own PV. Though you could cross charge the battery banks utilizing EG4 chargevertors. I'm not sure if both banks of 6000xp's can supply a single distribution box (if they will sync their AC outputs). If not then you would need another distribution box. The only other solution is to charge the batteries with multiple EG4 chargevertors, one per 240vac 30 amps of service (or lower charging per unit using 240vac 25 amps). This would be 3 or 4 units for 100 amp service or 6 or 8 units for 200 amp service. This adds several thousand dollars of cost and the chargevertors do not have remote reporting or control. You also can currently only have comms between your batteries and either the 6000xp's or the chargevertor. Most people will likely decide that comms to the 6000xp is more important, meaning that the chargevertors must charge based on voltage not SOC. All of this could be quickly resolved by the ability to limit AC input current. If you have three 6000xp's connected to 100 amp service you could limit them to 33 amps each (instead of the 50 amps currently) if you have four 6000xp connected to 100 amp service you could limit them to 25 amps each. If you have two 6000xp's connected to 50 amp service you could limit the input to 25 amp (or 20 amp with consequences). Obviously these limits will also limit the available current for charging. There are likely many people who love the 50 amp bypass mode. Maybe your house has 200 amp service and you only need to supply up to 100 amps to your house. Being able to supply the full 100 amps to the house while having 22,320 Watts available to quickly charge a large battery bank on cloudy days or in order to take advantage of variable electric rates is awesome.

    • @Slackware1995
      @Slackware1995 Месяц назад

      I personally believe a large percentage of 6000xp users would not only benefit from input limits but love them. I had originally added a 120vac 30 amp circuit for my previous RV. When I purchased the house it had a 240vac 30 amp circuit for a generator. We are planning on selling the house in a few months so I don't see a reason to buy a new 50 amp breaker and upgrade the wiring; especially considering that I have two 6000xp's in my RV which would need two 50 amp breakers. My experience with the 240vac 30 amp breaker is that if I'm close to 30 amps for about an hour the breaker will trip. This means that I have to limit myself to 27-28 amps (6480-6720 Watts), or 13.5-14 amps (3240-3360 Watts) per 6000xp. My base load plus the smaller AC uses about 1800 Watts while the base loads plus the larger AC is about 2000 Watts. The base loads with both AC units running is around 3500-3800 Watts. If the 6000xp's decide to go into Bypass with both AC units running there is nothing left to charge the batteries (I'm fine with this) but a single AC allows for Bypass and charging the batteries. I currently am configured to charge using about 3800 Watts, which allows running the smaller AC unit. The only time I run the AC at home is on hot days when I'll be working inside. This means that most of the time I could charge at 6400 Watts instead of 4800 Watts. With an AC input limit this would be automatic. I'd set both 6000xp's a limit of 13.5 or 14 amps. Magically I could run one or both AC units and the 6000xp would charge the batteries with what is available. If I don't run the AC units then the batteries would automatically charge faster. If EG4 gave us the ability to configure charging amps for each of the 3 AC start/stop times then I could have a work around. Maybe 0 amps charging from 11 am to 6 pm, from 10 pm to 6 am full charging (because the AC units are both off), from 6 am to 11 am and 6 pm to 10 pm allow charging based on the larger AC unit running. It wouldn't be perfect and I'd need to change the settings when camping and connected to 240vac 50 amp service and then remember to switch it back when at home. I know someone will say "just use an EG4 chargevertor". I have a version 2 and it's great for using a small generator. Remember that I can only communicate with batteries with either the 6000xp's or chargevertor. It makes more sense to connect the 6000xp's. This means the chargevertor doesn't have battery SOC and the chargevertor doesn't have remote control nor remote monitoring. This means changing the charging amps if its hooked to the generator, 120vac 30 amp service or 240vac 30/50 amp service. This requires going into the RV basement. It would be nice if the EG4 chargevertor integrated with the EG4 6000xp (and other EG4 inverter systems like the 12k and 18k). If you could plug the chargvertor comm into the 6000xp and the 6000xp relayed battery SOC and configuration data while the chargevertor sent the 6000xp charging data so that we could use the EG4 app or webpage to update chargevertor settings and monitor charge amps/Watts and historical data it would be great. Especially if you could parallel the chargevetors with comms to a 6000xp. Heck I'd get a 2nd chargevertor if that was possible.

  • @tslucam
    @tslucam Месяц назад

    That's awesome. I think this is the first portable i've seen with extruded aluminum. Nicely done. And thank you for the details on the build.

  • @noyjr9492
    @noyjr9492 2 месяца назад

    You think another eg4 battery would fit behind this contraption?

    • @alaskajoe61
      @alaskajoe61 2 месяца назад

      @@noyjr9492 with this extrusion you can get different lengths. So yes you could

  • @cory8837
    @cory8837 2 месяца назад

    You should be put in jail for not mentioning the cost.

    • @d.pollard5962
      @d.pollard5962 Месяц назад

      it is built to last, $500 was my estimation but with everything more like $800 to 1000

  • @MS-ie1gs
    @MS-ie1gs 2 месяца назад

    Amazing build. One potential add for my future build would be a car charger input. Load this up in a truck (would take some creativity) and charge quickly at a EV charging station. Also, potentially use an EV to charge using newer V2L technology...why not use the 100kWh EV battery as an emergency backup on a cloudy day!

  • @Madsci-zy8wm
    @Madsci-zy8wm 3 месяца назад

    Search RUclips for "6000xp is not UL9540 certified. YOU CANNOT LEGALLY install in the US along with solar panels." if you're planning to install a 6000XP at your home.

    • @cory8837
      @cory8837 2 месяца назад

      I guess I'm going to jail then 😂

    • @Marco-Alexi
      @Marco-Alexi Месяц назад

      Incorrect. The 6000XP does not feed to the grid. It can't. Therefore, it is no more illegal than plugging in a lamp your kid made in science class, or your vacuume cleaner that isn't ul9540 certified. That certification is only required for grid tied inverters that send power TO the grid.

  • @InVinoVeritas.
    @InVinoVeritas. 4 месяца назад

    Nice setup!! Hope to get same system. Question, is your portable system grounded or need to be? Maybe if for permanent home installation? Thanks.

    • @alaskajoe61
      @alaskajoe61 3 месяца назад

      It is grounded via the 50 amp plug from my service panel.

  • @JonOvalle
    @JonOvalle 4 месяца назад

    You absolutely made it portable! That’s awesome.

  • @jimgraham290
    @jimgraham290 4 месяца назад

    If the battery is below the threshold set - 30%, and the inverter is in bypass mode running the loads; the small amount of solar being generated by that panels will be used to charge the batteries?

    • @alaskajoe61
      @alaskajoe61 3 месяца назад

      It depends how small the solar generation is. There is a minimum needed to begin charging. I think it is on the order of 100-200 watts being generated to begin charging. There is a loss going from solar generated power to battery changing power. If I have 200 watts on my panels, maybe because it is early morning or rain clouds, it may only charge the battery with 30 watts or something along those lines. It will take forever at that rate to charge. The bypass mode will stay in effect until the panels charge the battery to +10% of what your cutoff setting is, so in my case the battery needs to get to 40% before it switches from bypass to battery power for the loads.

  • @justanotherdillhole7824
    @justanotherdillhole7824 4 месяца назад

    thanks for the cheat sheet ps nice set up you created mobile and connections etc

  • @MaNGLeDSHaDoW
    @MaNGLeDSHaDoW 4 месяца назад

    Really nice construction and build. Obviously high quality. Question: where is your neutral-ground bond in the system? I have one of these inverters and am in the process of making the plans to set it up. I’d like to do something similar but the neutral-ground connections for this unit are a bit tricky. Remember, this unit does not have dynamic neutral-ground bonding capabilities as they are right now (from what I’ve read). It looks like you used a three prong 50a grid input connection, which means there’s definitely an upstream neutral-ground bond. This means that setting 26 should be disabled (no neutral-ground bond in the unit) and your breaker panel on the cart should have the neutrals and grounds separate. However, if you operate the unit without the grid input connected, there wouldn’t be a neutral-ground bond in the system. Conversely, if the neutrals and grounds are bonded in the unit and/or in the panel on the cart, you could have more than one ground-neutral bond in the system if the Grid input is connected. So you have to be pretty specific on your use case and it almost seems like the unit should be hardwired and stationary (or at least be very very very careful with how you use it). @willprowse any comments or suggestions?

    • @alaskajoe61
      @alaskajoe61 4 месяца назад

      Thanks for the compliment about the build. I am pretty happy with it. I have the neutral-ground bond disabled on the inverter. The main service panel where the utility feed comes in is the only location where the neutral and ground are bonded. All my other panels in the house are not bonded. There are two ways my inverter system stays bonded: 1) through the 50 amp grid plug as you mentioned. 2) the output of my inverter system, the 30 amp plug, connects to my critical load panel in the house via a generator interlocked backfed breaker. That critical load panel's ground and neutral lines goes back to the main service panel which is bonded. Through the 30 amp plug the ground and neutral lines do not get interrupted if the backfed breaker is shut off. The ground and neutral lines on this 30 amp connection are screwed to their respective bus bars in the critical load panel. Just to restate, the critical load panel does not have the ground and neutral bonded in that panel, it is bonded back at the main service panel. If you look at 1:46 of my video I am showing the generator inlet plug on the wall. It has the required label (required by my locality) specifying that it must be a floating neutral system that is plugged into that plug. It all depends how it is set up in the panel and how you switch from grid to the generator. Since I am using a backfed breaker method in the critical load panel, only the hots get disconnected. Had I used a generator transfer switch, those can disconnect both the hot and neutral, in that case it would be a different setup. If I was to disconnect the inverter from the 50 amp plug and the 30 amp plug and use the inverter and battery as a stand alone power source, then I would need to enable neutral-ground bond in setting 26.

    • @stephenfuller2936
      @stephenfuller2936 4 месяца назад

      @@alaskajoe61 I looked back at 1:46 and can confirm you definitely have the right labeling. Can you estimate how much the extrusion set you back by itself? Looked like around 600-800 by my guestimations. I may make a version using 4x4's instead just based off the affordability of wood.

    • @alaskajoe61
      @alaskajoe61 4 месяца назад

      @@stephenfuller2936 I don't know exactly the cost of all the extrusion I purchased but I would also guess in the range you estimated.

  • @richardatkinson6031
    @richardatkinson6031 4 месяца назад

    wow! I don't know which I like better the cart or the solar. Very informative video.

  • @samfish6938
    @samfish6938 4 месяца назад

    RUiXU | Lithi2-16 | 51.2V314Ah | 16kWh LiFePO4 Battery $2999 i think they might be similar batterys

    • @d.pollard5962
      @d.pollard5962 4 месяца назад

      buying one of these soon let's try to keep it quiet til after I get the 2 I need and want to run my home, thanks. lol, but serious

  • @upspincreek2210
    @upspincreek2210 4 месяца назад

    I’ll be buying this inverter in a few weeks so really appreciate this level of detail you provided. I will be referring back to this again I’m sure.Thank you for taking the time to share this!

  • @quickquote1568
    @quickquote1568 4 месяца назад

    Bet this can't start and run a 6kW motor load like a 6kW well pump.

    • @d.pollard5962
      @d.pollard5962 4 месяца назад

      Will prowse does it, diy solar fun with Ray loveless does it and more with his.

    • @quickquote1568
      @quickquote1568 4 месяца назад

      @@d.pollard5962 They've never started a 6kW inductive load on video. 6kW is an 8 horsepower load. In fact, this inverter even failed to start Ray Loveless' home's AC unit without grid assist. I've even asked SS month's ago to create a video with their 6KW inverter starting an 8 HP motor and they haven't done it either.

    • @branch_ranch
      @branch_ranch 4 месяца назад

      Sounds like you need an SQ grundfos well pump with soft start.

    • @quickquote1568
      @quickquote1568 4 месяца назад

      @@branch_ranch Grundfos pumps are way too expensive.

    • @d.pollard5962
      @d.pollard5962 4 месяца назад

      @@quickquote1568 East Texas Homestead just did a video of one of his 3 doing a well pump. I knew I had seen it, sorry I mentioned ones that did not cover your specific issue. I thought those would give some info and you could ask them for more guidance. Hope that helps.

  • @d.pollard5962
    @d.pollard5962 4 месяца назад

    Thank you so much. I am going to order and build this set up because I plan on renting out my home in several years and don't want to have to take down my set up. Thank you for your videos and help. I have questions about putting it together and hook up if you can explain in more videos I/we would appreciate it

  • @nosborne24
    @nosborne24 4 месяца назад

    I’m looking to buy this inverter and you are the first person that I have found that has explain the settings that I was interested in. Thank you very much.

  • @awbean5254
    @awbean5254 4 месяца назад

    GREAT PROJECT & QUALITY BUILD! WHAT IS THE POSSIBILITY TO INSTALL ANOTHER EG4 BATTERY 🔋 ON THE BACKSIDE TO DOUBLE YOUR BATTERY 🔋 POWER ON A SMALL FLOOR FOOTPRINT 👣 IF WALL SPACE IS LIMITED?

    • @alaskajoe61
      @alaskajoe61 4 месяца назад

      Yes that would be possible but you would want longer members at the bottom instead of the 2x 610mm length I used

  • @rroades
    @rroades 5 месяцев назад

    Very interested by this as I’m doing something very similar but on a hand truck that lays flat, holds 800lbs. The links in the description are not active. Can you add them in a pinned comment so we can view them?

  • @gbsorenson
    @gbsorenson 5 месяцев назад

    That's awesome, and pretty much what I want to do. I have a 10 breaker generator transfer switch installed and want to use a 6000xp as my backup generator. I plan on putting in about 4000w of solar panels to start with, add to them as needed. I was going to do server rack batteries, but my look into just doing the EG4's. Nice work!

  • @jordanjones6137
    @jordanjones6137 5 месяцев назад

    how did you mount the battery and inverter?

    • @alaskajoe61
      @alaskajoe61 5 месяцев назад

      In the video at 5:22 to 5:34 I show the cross members that hold the battery and the inverter.

  • @WillProwse
    @WillProwse 5 месяцев назад

    Very nice

    • @alaskajoe61
      @alaskajoe61 5 месяцев назад

      Thank you very much. I've watched most of your videos. It was your RUclipss on the 6000XP and the PowerPro battery videos that got me thinking about this project. Thank you!

  • @Madsci-zy8wm
    @Madsci-zy8wm 5 месяцев назад

    With all of the well documented problems that the EG4 6500EX inverters are having, why on Earth would you buy one of these low cost, high frequency output transformerless inverters? There is very little difference between the EG4 6500EX and the EG4 6000XP. They both use low cost, high frequency inverter tech which yield a shorter life expectancy and a far poorer peak power capacities than "Real" heavy duty, low frequency, transformer based inverters. There were no major design changes between the EG4 6500EX and the EG4 6000XP. A change in color scheme and a few minor differences in the component layout is about it. The Chinese have been trying to get their high frequency inverter tech right for over 30 years and have not succeeded and probably never will. Don't take my word for it, Google or search youtube for "low frequency inverter vs high frequency inverters"

  • @myhificloud
    @myhificloud 6 месяцев назад

    Intelligent build and thank you for the video. Very much looking foward to future updates/upgrades/testing and your insights. Thanks again

  • @meilyn22
    @meilyn22 6 месяцев назад

    That's a fantastic build. Super smart.

  • @Panhandlehomestead
    @Panhandlehomestead 6 месяцев назад

    Wow I want one! Nice work sir

  • @makesaveinccomm
    @makesaveinccomm 6 месяцев назад

    That look nice, but you can build out of lumber or wood, cheaper, 4 wheel flat dolly at harborfreigh 14 usd. Other lumer at hd or wood pallets... needed screws

    • @meilyn22
      @meilyn22 6 месяцев назад

      No thanks. We prefer what's in the video..

  • @rodneyhillbrant8418
    @rodneyhillbrant8418 6 месяцев назад

    50 amp because It has a 50 amp bypass from the grid

  • @terrahillfarm
    @terrahillfarm 6 месяцев назад

    Very nice and clean build you did there. I built a 3000w backup with 5.12 kWh battery and couldn’t believe how well it replaced my portable generator. No carbon monoxide risks and no trips to the store for fuel if you have some decent solar panels. Started expanding to whole house solar and recently ordered a pair of the XPs. Great job keep going! 👍☀️⚡️💡🔋

  • @alexandermayorga7987
    @alexandermayorga7987 6 месяцев назад

    What did you have to do to get the 6000XP to communicate to the battery? Did you have to do any firmware updates or when you plugged it in, it worked?

    • @alaskajoe61
      @alaskajoe61 6 месяцев назад

      I just followed the instruction on which port to connect, the dip switch configuration and make sure the battery and inverter were configured for lux battery

    • @alexandermayorga7987
      @alexandermayorga7987 6 месяцев назад

      Thank you! I had a little trouble but managed to get it done and working@@alaskajoe61

  • @Steven-sp8mc
    @Steven-sp8mc 6 месяцев назад

    *promosm* 💪

  • @fredrichey222
    @fredrichey222 6 месяцев назад

    50 amp is correct it is in the specs!

  • @australianmade2659
    @australianmade2659 6 месяцев назад

    I think the breakers on the unit are bigger as you want to discriminate between breakers. You don’t want the generator breaker to trip BEFORE the house circuit breakers.

  • @eddiechavez72
    @eddiechavez72 6 месяцев назад

    If you wanted to add an extra battery would you connect it together with a 2/0 battery cable?

  • @larryphillips4164
    @larryphillips4164 6 месяцев назад

    California is aids.

  • @Lukeor
    @Lukeor 6 месяцев назад

    awesome, dude.....

  • @DrAriene
    @DrAriene 6 месяцев назад

    @alaskajoe61 great video. Please make more. I'd like to see more. Does your setup allow you to add another battery to the back side? How much did the whole project end up costing if you don't mind sharing?

    • @alaskajoe61
      @alaskajoe61 6 месяцев назад

      The size of cart I made does not really have enough room for a battery on the back side. However, if you order your rails at the bottom a bit longer you could certainly fit two batteries on it. The inverter was $1400, the battery $4000. All the extrusions, breaker panel, etc was roughly on the order $800-1000

    • @meilyn22
      @meilyn22 6 месяцев назад

      I think that battery is now 3700 the last time I checked.

  • @sgdesignwork
    @sgdesignwork 6 месяцев назад

    The rack is great! Would you be able to make a video explaining the wiring of the xp and details of your connection to the house? I just bought a ecoflow ultra and will have the smart panel 2 installed soon. I'm wishing there was some way to use the PowerPro battery with the Ecoflow system. If you could add a contact to your channel that would be great. I also live in California.

  • @Scat.original
    @Scat.original 7 месяцев назад

    Could you add links to all the electrical components and to links on Automation Direct? Also the link to the Aluminum plate and lenghts for each extrusion? Thanks Great Works

  • @iowac
    @iowac 7 месяцев назад

    question I am just now trying to get mine online I got the app its asking for customer code, do we have to get that from eg4 electronics?

  • @Mike-01234
    @Mike-01234 7 месяцев назад

    The manual isn't very good lot of things left out

  • @ScottieBMan
    @ScottieBMan 7 месяцев назад

    What settings do you have for grid powering option? Lead Acid or Li Ion? Etc…?

  • @dennisbushmitch8416
    @dennisbushmitch8416 7 месяцев назад

    Please write in some comments what issues you had configuring your inverter to charge the batteries from the grid without PVs. If you could post a small document, would be great. I just bought the same inverter and I hear, it’s not well documented.

  • @phebrian
    @phebrian 7 месяцев назад

    This is great I’ve been thinking of doing something very similar. Thanks for sharing your experience.

  • @sspyder181
    @sspyder181 7 месяцев назад

    It can do 50 amp bypass from grid.

  • @AlexHernandez-de7iz
    @AlexHernandez-de7iz 7 месяцев назад

    Great work! I also have a 6000XP and Power Pro battery. I just received my bluesun 460w bifacial panels. Soon enough I’ll say good by to Edison!

    • @jdepew
      @jdepew 4 месяца назад

      Where did you buy your solar panels?