Danfoss AERO TAMPERPROOF. How to lock, limit, set, thief protect and mount radiator head.
Locking the Radiator Head:
Danfoss Aero Tamperproof heads have a locking feature to prevent tampering with the temperature settings. Locate the locking mechanism on the side of the head.
Use a tool provided by Danfoss to turn the lock to the locked position. This will prevent anyone from adjusting the temperature setting without the tool.
Limiting the Temperature:
Danfoss Aero Tamperproof radiator heads allow you to set a maximum temperature limit to prevent overheating in the room.
Look for a temperature limit adjustment pin on the radiator head.
Adjust the pin to your desired maximum temperature. This will prevent the radiator from heating the room above the set limit.
Setting the Temperature:...
Просмотров: 43

Видео

Danfoss AERO. How to lock, limit, set, thief protect and mount radiator head.
Просмотров 66Месяц назад
Locking the Radiator Head: Danfoss Aero heads have a locking feature to prevent tampering with the temperature settings. Locate the locking mechanism on the side of the head. Use a tool provided by Danfoss to turn the lock to the locked position. This will prevent anyone from adjusting the temperature setting without the tool. Limiting the Temperature: Danfoss Aero radiator heads allow you to s...
Danfoss REDIA. How to lock, limit, set, thief protect and mount radiator head.
Просмотров 812 месяца назад
To lock, limit, set, and mount the radiator head Redia from Danfoss, you typically follow a set of instructions. Locking the Radiator Head: Danfoss Redia heads have a locking feature to prevent tampering with the temperature settings. Locate the locking mechanism on the side of the head. Use a tool provided by Danfoss to turn the lock to the locked position. This will prevent anyone from adjust...
How Thermostatic Radiator Valves (TRV) work - presetting is the key!
Просмотров 1562 месяца назад
Radiator valves play a crucial role in controlling the flow of hot water through a radiator, allowing you to regulate the temperature in a room. Properly setting or "presetting" these valves is indeed key to achieving optimal heating efficiency. Here's a general overview of how radiator valves work: Thermostatic Radiator Valve (TRV): Many modern radiator valves are thermostatic, meaning they ha...
Efficient AHU Energy Management: AB-QM & NovoCon in Action!
Просмотров 1463 месяца назад
NovoCon is digital actuator that facilitates continuous monitoring, active energy management, and preventive maintenance. It is designed to operate in various building types, including offices, hotels, hospitals, cruise ships, universities, data centers, shopping malls, museums, and supermarkets. Key features and applications may include: Continuous Monitoring: NovoCon likely provides real-time...
Icon2 24V Danfoss Thermostat Installation
Просмотров 4743 месяца назад
Installation Thermostats can be wired in either BUS or Star configuration, see Master Controller Installation Guide for more information. Optional floor sensor requires use of electrical conduit! Installer Menu Touch and hold to access the Settings Menu. In Settings Menu, touch and hold to access the Installer Menu. Menus ME1:Range limitation of setpoint for room temperature. ME2: Info / versio...
How does ir work - Heat Pump Optimizer on Icon2?
Просмотров 5364 месяца назад
In cold climates. Heat pumps may go through defrost cycles to remove ice buildup on the outdoor unit. Danfoss Icon2 "Heat pump optimiser" on other words "Automatic by-pass" feature. Ensures flow circulation at any time. Heat pump needs circulation. Using this feature. Heat pump heating demand control can be connected to Icon2 boiler relay. To have less heat pump compressor start/stop cycles.
Step-by-Step Guide: Installing Underfloor Heating Control Hub with Multiple Thermostats
Просмотров 4754 месяца назад
The Danfoss Icon 230V wired wiring center is designed to enable the connection of multiple thermostats to a single system. This allows for more advanced control over heating zones and can improve the overall efficiency and comfort of a heating system. Here's a brief overview of its features and functionality: Multiple Thermostat Connections: The Icon 230V wiring center can accommodate connectio...
DANFOSS TP5001 RESET
Просмотров 1,7 тыс.5 месяцев назад
DANFOSS TP5001 RESET
Calibration (offset) Danfoss thermostat WT-P "BasicPlus2"
Просмотров 2,2 тыс.5 месяцев назад
Calibration (offset) Danfoss thermostat WT-P "BasicPlus2"
Danfoss thermostat TP5001 SETUP & MENU
Просмотров 10 тыс.5 месяцев назад
Danfoss thermostat TP5001 SETUP & MENU
Icon 230V Programable Danfoss Thermostat MENU
Просмотров 8616 месяцев назад
Icon 230V Programable Danfoss Thermostat MENU
Icon 230V Programable Danfoss Thermostat Installation
Просмотров 1,1 тыс.6 месяцев назад
Icon 230V Programable Danfoss Thermostat Installation
Icon 230V Display Danfoss Thermostat MENU
Просмотров 2,1 тыс.7 месяцев назад
Icon 230V Display Danfoss Thermostat MENU
Icon 230V Display Danfoss Thermostat Installation
Просмотров 1,2 тыс.7 месяцев назад
Icon 230V Display Danfoss Thermostat Installation
Danfoss Icon2 Room Thermostat Featured MENU
Просмотров 8648 месяцев назад
Danfoss Icon2 Room Thermostat Featured MENU
Danfoss Icon2 Room Thermostat MENU
Просмотров 1,8 тыс.8 месяцев назад
Danfoss Icon2 Room Thermostat MENU
Underfloor cooling heating. How does it work? Danfoss Icon App 0004
Просмотров 1,3 тыс.8 месяцев назад
Underfloor cooling heating. How does it work? Danfoss Icon App 0004
Danfoss Icon2 Review underfloor heating cooling control system
Просмотров 5 тыс.8 месяцев назад
Danfoss Icon2 Review underfloor heating cooling control system
Danfoss Icon2 Fast Installation guide
Просмотров 7 тыс.9 месяцев назад
Danfoss Icon2 Fast Installation guide
Danfoss Icon 230V Dial In Wall Room Thermostat Installation
Просмотров 1,4 тыс.10 месяцев назад
Danfoss Icon 230V Dial In Wall Room Thermostat Installation
How to turn subtitles ON and change language for YouTube videos
Просмотров 7310 месяцев назад
How to turn subtitles ON and change language for RUclips videos
Noisy radiator. How To Fix Banging Ticking Knocking Hammering radiator noise?
Просмотров 19 тыс.Год назад
Noisy radiator. How To Fix Banging Ticking Knocking Hammering radiator noise?
How to lower underfloor heating supply temperature for multifamily house. Check this project video.
Просмотров 305Год назад
How to lower underfloor heating supply temperature for multifamily house. Check this project video.
Radiator connection
Просмотров 435Год назад
Radiator connection
Underfloor heating actuators. Avoid mistakes. Tips and tricks!
Просмотров 6 тыс.Год назад
Underfloor heating actuators. Avoid mistakes. Tips and tricks!
Thermostatic radiator valve with remote sensor working principle
Просмотров 1,5 тыс.Год назад
Thermostatic radiator valve with remote sensor working principle
Plumbing FAILS! Fun to watch. Check how not to do.
Просмотров 726Год назад
Plumbing FAILS! Fun to watch. Check how not to do.
Smart heating with Danfoss Ally App and Pro programmable radiator thermostat
Просмотров 3,3 тыс.Год назад
Smart heating with Danfoss Ally App and Pro programmable radiator thermostat
Balancing valve setting
Просмотров 1,1 тыс.Год назад
Balancing valve setting

Комментарии

  • @333tche
    @333tche 16 дней назад

    All our thermostats show a temperature at least 2 degrees higher than what they are set up for. Can that be heating coming from the appartment below? If yes, can we turn the floor heating system off completely and turn it on again when winter comes? Is there anything particular to be done if shutting it off?

    • @heatingsolutions123
      @heatingsolutions123 13 дней назад

      In case thermostats show higher temperature comparing to than what they are set. Heating should be off already. Heat most probably is coming from sun radiation. Barely from neighbours that much. There is nothing particular you should do to switch heating off as it is already off. Just in case you can set lower or minimum temperature.

  • @MrRogez
    @MrRogez 19 дней назад

    Hi thanks for taking the time to make these videos. I have 02.3 on my screen… do you know what that is? I looked at fault codes and can’t see that code In the manual. 👍🏻

    • @heatingsolutions123
      @heatingsolutions123 19 дней назад

      Hi! Strange... I would recommend resetting, TP 5001 Reset Video is here: ruclips.net/video/5fzT1mMkY7g/видео.htmlsi=8XEnOrIMdu7Mc_dI In case resetting does not help - thermostat most probably is broken.

  • @nemanjagradinac5419
    @nemanjagradinac5419 23 дня назад

    Fantastic rig you’ve made my friend, and literally the best training video on this topic I have ever seen. You’ve got an excellent way of explaining everything in various conditions and you’re clearly very talented in your job and capable of teaching others in simpler terms! Well done mate 🤙 and absolutely spot on!

  • @xFiniti64
    @xFiniti64 28 дней назад

    what ? ant reklaminio stendo ziuriu lietuviskai parasyta :D

  • @afolabileshi3179
    @afolabileshi3179 29 дней назад

    I am currently having problem putting the floor heating active. It has been a nightmare

    • @heatingsolutions123
      @heatingsolutions123 29 дней назад

      If heating indicator (waves) are on. Heating should work.

  • @johncarry5989
    @johncarry5989 Месяц назад

    Thank you for making this video. I can now use my heating properly. What a ridiculously overly complicated device this thermostat is.

  • @shanepatchett4151
    @shanepatchett4151 Месяц назад

    Can you only have 4 different times or can you add extra

    • @heatingsolutions123
      @heatingsolutions123 Месяц назад

      4 different comfort and saving times. You can not add more unfortunately.

  • @agreatd
    @agreatd Месяц назад

    Turiu 088l0121 grindims, ar galima juos pakeisti i 088L1140, plug n play ar sudetingiau? davikliu / grindu visos info nezinau, nes statytojas dejo, ne as

  • @dictatorts
    @dictatorts Месяц назад

    Are they still available? I can see only Icon thermostats in the catalogue This one looks more robust and displays current temp all the time

    • @heatingsolutions123
      @heatingsolutions123 Месяц назад

      Yes. It is available, also TP 5001 Looks similar if you would need on - wall mounting or you have only 2 wires available you can use battery version for actuator or boiler control ruclips.net/video/BTGKSqTgHkA/видео.htmlsi=tfZ6a8J__gGzolM3

    • @heatingsolutions123
      @heatingsolutions123 Месяц назад

      Wiring center: ruclips.net/video/5Z44RHS4N-o/видео.htmlsi=hHNiEjCxxYttjuFx

  • @estellesola7318
    @estellesola7318 Месяц назад

    Awful thermostat I can't use it, doesn't seem to be same settings as the video

    • @heatingsolutions123
      @heatingsolutions123 Месяц назад

      Might be you have another one similar looking TP5001, video on it is here: ruclips.net/video/BTGKSqTgHkA/видео.htmlsi=y_jhDb3r8apnsFbL

  • @futurechannel001
    @futurechannel001 Месяц назад

    Good day! How can I re-setup the control of thermostat. I want to make the thermostat to action other actuators. Example now the thermostat from one room give control to 1-2-3-6-7. I want to change to give action to 1-2-4-5-6 and to move control of 3 and 7 on other thermostat. Thank you.

    • @heatingsolutions123
      @heatingsolutions123 Месяц назад

      Hi! Select "Uninstall", then "OK". Select with up arrow output you want to change, confirm with "OK". One by one. And then use "Install" as on video.

    • @futurechannel001
      @futurechannel001 Месяц назад

      But if I select Uninstall? What will be uninstalled? Themostate or the actuators?

    • @heatingsolutions123
      @heatingsolutions123 Месяц назад

      @@futurechannel001 actuator output will be uninstalled from master controller. You can not uninstall thermostat, only reset.

    • @futurechannel001
      @futurechannel001 Месяц назад

      @@heatingsolutions123 Can you please make a video with this explanation how to change the setup of the Thermostat and Actuators.

    • @heatingsolutions123
      @heatingsolutions123 Месяц назад

      @@futurechannel001 Sorry, I do not have first Icon version anymore. Another way to solve your case would be reseting Icon Master ruclips.net/video/ErfuVqSK-8o/видео.htmlsi=3DjTe5BdppbQl_Lk and all room thermostats to factory setting. Icon/Icon2, wireless and wired reset is the same: ruclips.net/user/shortslPaoofPJnFo?si=Gb4-5lRU_kbA1-xs After reseting you can program all as new

  • @kayleigh16
    @kayleigh16 Месяц назад

    Mine won't come on at all how do you turn off the timer?

    • @heatingsolutions123
      @heatingsolutions123 Месяц назад

      Hi:) If you really got same thermostat TP5001. Hold "M" for 6 seconds. At P01 SET 01 - (Manual temperature operation)

  • @Falco_Aqua_Artist
    @Falco_Aqua_Artist 2 месяца назад

    Danke sehr hilfreich ❤

  • @marthal9388
    @marthal9388 2 месяца назад

    Very difficult thermostat to understand the operation, even though you explained it very well I blame the manufacturers.

    • @heatingsolutions123
      @heatingsolutions123 Месяц назад

      Less sophisticated would be not programmable. Such as RET 1000 or RET 2000

  • @bernadetebozza6493
    @bernadetebozza6493 2 месяца назад

    Se vocês nao compreende na sua língua, imagina eu que falo português. Hahaha

  • @sem2738
    @sem2738 2 месяца назад

    How do I turn on the floor heating all the time?

    • @heatingsolutions123
      @heatingsolutions123 2 месяца назад

      P01 set 01 - manual control. Rise temperature higher than room. If you have floor temperature sensor at P02 set 03 and you will see floor temperature.

  • @furkanustunsoy989
    @furkanustunsoy989 2 месяца назад

    Hi, I have water underfloor heating system which actuator do I need to use NC or NO and why?

    • @heatingsolutions123
      @heatingsolutions123 2 месяца назад

      For underfloor it is more common to use NC. In case electricity fails or automatics - your floor will be secured. And as concrete holds heat you will not get frozen for a cuite long time to fix the problem.

  • @anTonho20
    @anTonho20 2 месяца назад

    Thanks for clear instructions :)

  • @uniqueBG78
    @uniqueBG78 2 месяца назад

    Thank you. How about model WT-D? There is no clock symbol on the dial, there is only < > M. Please help how to adjust the offset.

  • @HuseyinD44
    @HuseyinD44 2 месяца назад

    Hello, shouldn't the liter adjustment be made on the glass tube? Also, should they all be on when making adjustments via the tube?

    • @heatingsolutions123
      @heatingsolutions123 2 месяца назад

      If you know exactly how much litres/min you need for each cirquit you can adjust with flow meter. Another way is using presetting as on video.

    • @HuseyinD44
      @HuseyinD44 2 месяца назад

      @@heatingsolutions123 If they are all on, is the setting correct? Or should I move on to the next after setting one zone? Is there a video about this?

  • @Hayley-we7qz
    @Hayley-we7qz 2 месяца назад

    Can you only select heating to come on at the times already programmed such as 6.30am and 8.30am. Or can I select different times. I’d like the heating to come on during the night about 3am until 6am

    • @heatingsolutions123
      @heatingsolutions123 2 месяца назад

      You can select any time you would like to. How to, is in this video somewhere from 6:30....

  • @Dan-xv4vx
    @Dan-xv4vx 2 месяца назад

    Helpful. My thermostat was flashing e6. I reset it which seems to have got rid of the e6 message. But now our boiler is on all night from like 11pm - 7am. No heating, just the boiler being on and releasing the steam from the vent outside. Any ideas why? Thanks, Dan.

    • @heatingsolutions123
      @heatingsolutions123 2 месяца назад

      Usually if heating is not needed, boiler switches to hot water preparation. If hot water is not needed, hot water tank is full of hot water. Boiler goes to stand by mode. If steam goes out - boiler is on. Please check your set temperature and real temperature measured by thermostat. If set temperature is lower you should see waves symbol and boiler should be on. Otherwise boiler should be off (if hot water is not needed) To check if installation is right you can switch from scheduling mode to manual temperature mode.

    • @Dan-xv4vx
      @Dan-xv4vx 2 месяца назад

      @@heatingsolutions123 thanks. Yes I've currently had it in manual mode for nearly 48 hours which does seem to have it working perfectly fine. So I'm not sure why it wasn't working fine in 5/2 setting.

  • @flaviusvirlan3406
    @flaviusvirlan3406 3 месяца назад

    Some folks do this balancing on the flow meters, by taking the red caps off and setting the flow on the setting wheel. Is it a mistake ?

    • @heatingsolutions123
      @heatingsolutions123 3 месяца назад

      Setting on flow meters is another way of circiut balancing. Where do they get needed flow to set? Setting all flow meters at same flow would be a mistake if circuits are not same length.

  • @garyf5192
    @garyf5192 3 месяца назад

    Nicely done.

  • @Ri.Ma98
    @Ri.Ma98 3 месяца назад

    I have it on manuell but the Problem is that I sometimes have to press random bottoms until it turns the heating on sometimes it will not work till I have tried it for a few hours

    • @heatingsolutions123
      @heatingsolutions123 3 месяца назад

      I would try to reset it and set to manual again. Reset video is here: ruclips.net/video/jfTSCQ40qCo/видео.htmlsi=HrMsxPKfC44Bg9cP

  • @heatingsolutions123
    @heatingsolutions123 3 месяца назад

    Ačiū!

  • @yousafahmed7657
    @yousafahmed7657 3 месяца назад

    I have this same thermostat. I am not able to manually increase nor decrease my temperature. It just stays on the same number all the time and the heating icon does not come on. My downstairs one is working fine. Can you advice what I can do please

    • @heatingsolutions123
      @heatingsolutions123 3 месяца назад

      I would try reset, here is a video on it: ruclips.net/video/5fzT1mMkY7g/видео.html

  • @alexrussell5884
    @alexrussell5884 3 месяца назад

    Thanks for you help with this. How do you make it so the underfloor heating is deactivated? I’m trying to turn the heating off but the underfloor heating icon remains on and I don’t seem to be able to cool the flat down. Can you help?

    • @heatingsolutions123
      @heatingsolutions123 3 месяца назад

      Probably you have underfloor sensor. Please check setting P02 SET 01 - only room control, 02 - room and floor, 03 - only floor. I would set P02 and 01 for test if it helps. Video on setup is here: ruclips.net/video/Nzqw2VN4pOY/видео.htmlsi=jCTxjYCopcqOWxNT Video on thermostat reset to factory setting is here: ruclips.net/video/jfTSCQ40qCo/видео.htmlsi=6Oy-J_H9doCgWKRs

  • @chanellebritney7612
    @chanellebritney7612 3 месяца назад

    Who do I contact if it’s still not working after all this

    • @heatingsolutions123
      @heatingsolutions123 3 месяца назад

      Please contact maintenance company, installer or local Danfoss.

  • @alexrussell5884
    @alexrussell5884 3 месяца назад

    What does the number on the thermostat tell us? The temperature of the room at that time? Or the temperature that the thermostat think we're trying to maintain?

    • @heatingsolutions123
      @heatingsolutions123 3 месяца назад

      SET temperature is the temperature thermostat is going to maintain. Real room temperature is shown after you have pushed once "<" or ">". Calibration setting adjusts real measured temperature. I hope this explains the issue.

  • @alexrussell5884
    @alexrussell5884 3 месяца назад

    Thanks for the video. I manage to get the thermostat on 'P01 - 01' and then hit clock to remove the clock icon (which works). however once i've done that the reading on the thermostat is at 28.5 degrees and i can't seem to get it to go down. When i hit the arrows like you do in the end of your video it just shows me the thermometer icon and the word 'set' on the left side of the screen and 13 degrees - which i then cannot move. Can you help?

    • @heatingsolutions123
      @heatingsolutions123 3 месяца назад

      Reading might be temporarely wrong because of your hand heat for a while. Temperature reading should go down in a minutes if you do no touch it anymore. If you can not set below 13C degrees, might be limitation done in a menu: ruclips.net/video/4--W20us1hg/видео.htmlsi=W9yZF74M0lFo1fQ1

  • @chanellebritney7612
    @chanellebritney7612 4 месяца назад

    I change my temperature but it goes back to default temperature which means the house is always cold

    • @heatingsolutions123
      @heatingsolutions123 4 месяца назад

      Hi! Please adjust schedule and set time correctly. Or switch the schedule off, set manual mode. Video ir here: ruclips.net/video/OO0nVY5sgbU/видео.htmlsi=gCddx-estMr2ZRBC

  • @ja4291
    @ja4291 4 месяца назад

    I like rhe videos, really helpful. ❤

  • @user-gv9jv5sp7s
    @user-gv9jv5sp7s 4 месяца назад

    Hi, I have a combi-boiler and I’ve set my thermostat to timed mode (5/2) with the following: 07:00 - 18C 10:00 - 18C 17:30 - 19C 21:00 - 19C However, after event 4 (21:00), the boiler still switches when the temperature goes below 19C. Is this normal as I expect no heating after 21:00. Is the boiler not meant to turn off after 21:00 overnight and not come back on until 07:00? Thank you!

    • @heatingsolutions123
      @heatingsolutions123 4 месяца назад

      Might be you are using P02 01 - ON/OFF Load compensation is enabled. ON/Off load compensation is a feature of temperature control products such as room thermostats and programmable thermostats. On/Off load compensation is a proven method of minimising energy use by calculating the demand from a thermostat. As the temperature approaches the required setting, the boiler will fire for shorter periods of time, ensuring a constant temperature is maintained. This not only enhances comfort levels, but also uses less energy. On/Off load compensating products are ideal for use with modern systems in well-insulated houses. Recommended for use with gas condensing boilers. Thermostat prevents boiler working for too long period of time. In this way, the heating works more efficiently, as the return temperature of the heating return is lowered. Condensation is better. Less gas is consumed. Please try setting: P02 02 - ON/OFF standard operation. Boiler is ON till set temperature is reached. And setting: P03 01 - Normal start control.

  •  4 месяца назад

    If I’m not able to press any buttons ( when touching buttons nothing happens ), what could be wrong? Could it be locked so people dont mess with it? Is there a way to activate the controls?

    • @heatingsolutions123
      @heatingsolutions123 4 месяца назад

      Controls are only for system setup. Here are videos how to proceed: ruclips.net/video/2HrkCJHfqbw/видео.htmlsi=M36OPiCOBBYELmgu ruclips.net/video/qEo3Tbe1--A/видео.htmlsi=c46MjgLcrIsWAOTJ

  • @banarsisahu7811
    @banarsisahu7811 4 месяца назад

    thermostat show lock what do lock open

    • @heatingsolutions123
      @heatingsolutions123 4 месяца назад

      Unlock video: ruclips.net/video/KrxH8B9PwM0/видео.htmlsi=BGnJ2c4EE1kENIhp

  • @cuentaalterna1652
    @cuentaalterna1652 4 месяца назад

    So the problem can be solved by opening the valvula?

    • @heatingsolutions123
      @heatingsolutions123 4 месяца назад

      Yes, for temporarely problem solving. Open on max or close fully. Complete solution would be installing flow and return pipes properly.

  • @leannemoore2620
    @leannemoore2620 4 месяца назад

    Mine is set to 20°c on highest temp, no schedule, but its still rising to 24°c 😫

    • @heatingsolutions123
      @heatingsolutions123 4 месяца назад

      Probably wrong installation or thermostat is broken :(

  • @sarkhangadirzade3805
    @sarkhangadirzade3805 4 месяца назад

    Great video! By any chance, do you have a similar guide for Danfoss Icon master controller? I browsed around your channel, but couldn't find any.

    • @heatingsolutions123
      @heatingsolutions123 4 месяца назад

      Thank you for your feedback! Here is Icon first generation video: ruclips.net/video/2HrkCJHfqbw/видео.htmlsi=DfD9c_Rds7Egj-7I Here is Icon 2, second generation video: ruclips.net/video/52wKnb-YC9A/видео.htmlsi=WHMnF29-Jk380xMf and there are more separate videos about reset and thermostats setup. Tell me please if this is not what you were looking for?

  • @nataliemchardy
    @nataliemchardy 4 месяца назад

    Thank you so much for this video it helped me with the problems I was having with my thermostat

  • @hensondorsey1146
    @hensondorsey1146 4 месяца назад

    I dont understand my heaters keep coming on i just want to turn it off completely. Only switch it on when i need to… can u please explain

    • @heatingsolutions123
      @heatingsolutions123 4 месяца назад

      OK. Best way would be to set the thermostat to "manual" control, "schedule off". In case real room temperature is higher comparing to set temperature. Thermostat should be off. Otherwise it is broken. Schedule off: ruclips.net/video/OO0nVY5sgbU/видео.htmlsi=fUmpJ1aW5r-RcQnp

  • @MLabeeq
    @MLabeeq 4 месяца назад

    Thanks for sharing. Was really frustrated with my new home thermostat setting and this video is the only resource on internet that was helpful :))

  • @Gadomaitis
    @Gadomaitis 4 месяца назад

    Great video, thank you!

  • @Zenthorian1
    @Zenthorian1 4 месяца назад

    I changed my batteries in my thermostat and when it turns back on it shows the frost icon and temperature but none of fhe buttons are working? It doesnt power off or dim or anthting, none of the buttons work it just shows the same icons and the room temperature what could this be please? Ive tried different batteries, resetting the boiler but nothing works. Thanks

    • @heatingsolutions123
      @heatingsolutions123 4 месяца назад

      I think you got another similar looking TP 5001 thermostat. Please try to RESET: ruclips.net/video/5fzT1mMkY7g/видео.htmlsi=spYBIpL0Itk2bCIY and SET: ruclips.net/video/BTGKSqTgHkA/видео.htmlsi=BeICEo_Rp1dHZOJp

    • @Zenthorian1
      @Zenthorian1 4 месяца назад

      @@heatingsolutions123 yes I think it's the one you linked in that comment, I've tried that and it still does nothing, the power button doesn't do anything and none of the other buttons do anything, it literally stays on the same screen (blue tint to it) with the room temperature showing and the frost icon showing. Any ideas? Thanks

    • @heatingsolutions123
      @heatingsolutions123 4 месяца назад

      @@Zenthorian1 OK, I think it is broken then. Might be thermostat got moisture or fell and broke... or something else

  • @exquisitegarcia4405
    @exquisitegarcia4405 4 месяца назад

    Hi there, I have a Danfoss Tpone thermostat. My thermostat starts my scheduled heating 3 hours before my programmed time I’m assuming it’s preheating. for example, ( 7am - 11am for 21 is my scheduled heating time) the thermostat will activate hours before my programmed time which I do not want. Please can you tell me how I can set my thermostat to start at my programmed time and not preheat in advance? I have these modes - normal start, delayed start and optimised start. - Thank you so much.

  • @Hamsterliciousness
    @Hamsterliciousness 4 месяца назад

    Thank you! You're the only video out of about an hour of searching that solved my issue. I thought it was the wires in the walls vibrating. I've never had this issue before.

  • @jackieturner980
    @jackieturner980 4 месяца назад

    Thank you so much all sorted now

  • @jackieturner980
    @jackieturner980 4 месяца назад

    I’m unable to reset my danfoss thermostat, I’ve followed instruction but no joy. I’ve also set program 3 and I’m not able to change temperature. Can anyone help please

    • @heatingsolutions123
      @heatingsolutions123 4 месяца назад

      Might be you have different thermostat TP5001. Video how to reset it: ruclips.net/video/5fzT1mMkY7g/видео.htmlsi=kTO1mdct_R5jUOy0

    • @jackieturner980
      @jackieturner980 4 месяца назад

      @@heatingsolutions123 thank you, that’s sorted. Nice one! ⭐️

  • @SanneHoekstra
    @SanneHoekstra 5 месяцев назад

    I think those thermal actuators are very stupid. If you have 5 groups that are active for 50% of the time (for example with a heatpumps) you use 5 x 2W x 12 hrs per day. There are battery powered thermostatic controls for radiators, why hasn’t this technique been improved for those actuators….

    • @heatingsolutions123
      @heatingsolutions123 5 месяцев назад

      Thermal actuators are reliable, may last 10-30 years, has no noise. 5 x 2W x 12h x 30days= 3,6 kWh - not a lot.

    • @TheHellis
      @TheHellis 3 месяца назад

      I have battery operated TRVs at the moment and looking at these wired versions as a good alternative. The smart TRVs are not strong enough long term, requires batteries and have "smart crap" in them making them not do what I want.

  • @gascon861
    @gascon861 5 месяцев назад

    Call an exorcist