NFPA 13 3 & 4 Times Rule fire sprinklers spraying over horizontal and around vertical obstructions
NFPA 13 3 times rule and 4 times rule is used for Obstructions to Sprinkler Discharge Pattern Development. This will position the sprinkler head to spray over horizontal obstructions within 18 inches of deflector and around vertical obstructions. This is a full lesson to understand the 3 and 4 times rules.
Просмотров: 1 141

Видео

NFPA 13 Soffit and Cabinet Rule. Fire sprinklers spraying under obstructions
Просмотров 7763 месяца назад
Fire sprinklers spraying under obstructions located against walls. NFPA 13
NFPA 13 Beam Rule. Fire Sprinkler spraying under obstruction.
Просмотров 8344 месяца назад
Positioning of fire sprinklers to avoid obstructions to discharge
NFPA 13 obstructed unobstructed construction. Fire sprinkler distance below ceiling.
Просмотров 2 тыс.4 месяца назад
NFPA 13 Obstructed and Unobstructed Construction. Fire sprinkler distance down from ceiling.
Fire sprinklers in electrical rooms NFPA 13 NFPA 70
Просмотров 4395 месяцев назад
NFPA 70 dedicated electrical space is found under indoor electrical rooms 1000 volts nominal or less. Switchboards, panelboards, switchgear, or motor control. NFPA 13.
Ordinary Hazard Occupancy NFPA 13 Fire sprinkler head spacing
Просмотров 5845 месяцев назад
Ordinary Hazard Occupancy NFPA 13 Fire sprinkler head spacing
Fire sprinkler test question 001
Просмотров 2916 месяцев назад
Fire sprinkler test question 001
Difference between quick and standard response fire sprinklers
Просмотров 1,6 тыс.6 месяцев назад
Difference between quick and standard response fire sprinklers
NFPA 13 Compartment Definition
Просмотров 1758 месяцев назад
NFPA 13 Compartment Definition
NFPA 13 Small Room Rule. Standard spray fire sprinkler head spacing.
Просмотров 3868 месяцев назад
NFPA 13 Small Room Rule. Standard spray fire sprinkler head spacing.
Standpipe hose valve handle clearance
Просмотров 1948 месяцев назад
Standpipe hose valve handle clearance
Light Hazard Occupancy NFPA 13 Fire sprinkler head spacing.
Просмотров 76010 месяцев назад
Light Hazard Occupancy NFPA 13 Fire sprinkler head spacing.

Комментарии

  • @kurdisshop243
    @kurdisshop243 3 часа назад

    That's sweet they have a thread cutter set up to?

  • @albertmiranda7764
    @albertmiranda7764 3 дня назад

    wow .. these videos are so good and so helpful! please continue to make videos about NFPA 13

    • @NFPAJoe
      @NFPAJoe 2 дня назад

      @@albertmiranda7764 thank you! I have some more videos coming soon 😎👍

  • @MrTristans80
    @MrTristans80 6 дней назад

    Damn that deluge system will get that flamable matterials storage tank wetter than you mom on a friday night! Good work!

    • @NFPAJoe
      @NFPAJoe 5 дней назад

      Hahaaa 😂

  • @asoteico9528
    @asoteico9528 6 дней назад

    What a Toy !!! Need one of those !!!

    • @NFPAJoe
      @NFPAJoe 5 дней назад

      Couldn’t believe it. Awesome tool 👍

  • @Zx14rrrrrrrrrrr
    @Zx14rrrrrrrrrrr 7 дней назад

    Groovy baby

  • @asoteico9528
    @asoteico9528 7 дней назад

    Great !!! Nice set up !!!

    • @NFPAJoe
      @NFPAJoe 7 дней назад

      @@asoteico9528 deluge system with dry pilot line 🤙

    • @asoteico9528
      @asoteico9528 7 дней назад

      @@NFPAJoe Thanks Joe !!! Great dude !!!

  • @asoteico9528
    @asoteico9528 8 дней назад

    Great !! Would like to be there!!!

  • @patricks368
    @patricks368 11 дней назад

    That thing is my best friend for sch 40

    • @NFPAJoe
      @NFPAJoe 11 дней назад

      Definitely! Have to have it 💪

  • @patricks368
    @patricks368 13 дней назад

    Joe knows code. Nice job

    • @NFPAJoe
      @NFPAJoe 13 дней назад

      😎👍

  • @asoteico9528
    @asoteico9528 15 дней назад

    Great !!!

  • @asoteico9528
    @asoteico9528 15 дней назад

    Amazing !!!

    • @NFPAJoe
      @NFPAJoe 14 дней назад

      Yes it’s really cool technology!

  • @asoteico9528
    @asoteico9528 16 дней назад

    Great !!! Thanks Joe !!!

    • @NFPAJoe
      @NFPAJoe 16 дней назад

      Your welcome 😎👍

  • @asoteico9528
    @asoteico9528 16 дней назад

    Great job !!! Real one !!!

  • @asoteico9528
    @asoteico9528 17 дней назад

    Great job !!!

  • @asoteico9528
    @asoteico9528 18 дней назад

    How can I get into this union !

    • @NFPAJoe
      @NFPAJoe 17 дней назад

      Sign up and you will get on the list ! 💪 look up local 550 Bostons sprinkler fitters union and give them a call to get details

  • @asoteico9528
    @asoteico9528 18 дней назад

    Great !!!

  • @asoteico9528
    @asoteico9528 18 дней назад

    Great lecture !!!

    • @NFPAJoe
      @NFPAJoe 18 дней назад

      @@asoteico9528 thank you ! 😎👍

  • @jimmyreeder3815
    @jimmyreeder3815 24 дня назад

    Been installing sprinkler systems around 20 yrs now that is some beautiful looking work there good job

    • @NFPAJoe
      @NFPAJoe 24 дня назад

      Thanks 👍

  • @joenolan1574
    @joenolan1574 Месяц назад

    The melch

    • @NFPAJoe
      @NFPAJoe Месяц назад

      @@joenolan1574 Joe!!!!! 😎🤙

  • @ADOWAI
    @ADOWAI Месяц назад

    Why big duct at 8:15 ruclips.net/video/V0yOc47MkOY/видео.htmlsi=BNHpzP79gbJl2fr-&t=495 is NOTobstruction and small pipe @7:28 is obstruction and need to follow 3x rule ?

    • @NFPAJoe
      @NFPAJoe Месяц назад

      @ADOWAI 7:28 I was going over an example of how to use the 3 times rule. And then went to explain how when using specifically the standard spray upright and pendant in light and ordinary hazard occupancy only structural elements have to be acknowledged when spraying over an obstruction. Unless the obstruction is over 4’ wide. Let me know if you are understanding now. Thanks

  • @justinjordan4733
    @justinjordan4733 Месяц назад

    THANK YOU FOR THIS VIDEO!!!!

    • @NFPAJoe
      @NFPAJoe Месяц назад

      Your welcome!! 😎👍

  • @randym9183
    @randym9183 Месяц назад

    Wasnt a question but thanks for the info if your telling the truth

    • @NFPAJoe
      @NFPAJoe Месяц назад

      Your welcome. And yes I always tell the truth when doing RUclips. I don’t put it on RUclips unless I can reference to NFPA 👍

  • @TAHIRHUSSAINMEPINDUSTRY
    @TAHIRHUSSAINMEPINDUSTRY Месяц назад

    Super, i did not not understand what you spoke if obstruction over 4 feet? you need to make more videos about obstruction/installation as there are too many videos on this subject

    • @NFPAJoe
      @NFPAJoe Месяц назад

      Thank you. Yes my next video is on obstructions over 4 feet. I have a couple more videos I plan on making about obstructions.

  • @TAHIRHUSSAINMEPINDUSTRY
    @TAHIRHUSSAINMEPINDUSTRY Месяц назад

    Joe thanks your excellent video, so i will go residential high rise building quick response? where i can find position of QR sprinkler below ceiling in NFPA standard section?

    • @NFPAJoe
      @NFPAJoe Месяц назад

      If it’s a residential building I would assume the units would have residential style sprinkler heads. Check out my video on obstructed and unobstructed construction I go over distance below ceiling for all style heads 👍

  • @MohammedIbrahim-rp1kv
    @MohammedIbrahim-rp1kv Месяц назад

    nice one bro!! lot of like this definitions need to be clarified, thanks a lot and keep going

    • @NFPAJoe
      @NFPAJoe Месяц назад

      Thanks, will do! 😎👍

  • @turkfire
    @turkfire 2 месяца назад

    Perfect explanation. All clear !

    • @NFPAJoe
      @NFPAJoe 2 месяца назад

      😎👍

  • @TAHIRHUSSAINMEPINDUSTRY
    @TAHIRHUSSAINMEPINDUSTRY 2 месяца назад

    Joe, why you made limited videos? Why not continue other videos which have unique topic? Like Deluge valve etc

    • @NFPAJoe
      @NFPAJoe 2 месяца назад

      I do plan on making more videos. I want to cover all the different style sprinkler system valves and fire pumps.

  • @TAHIRHUSSAINMEPINDUSTRY
    @TAHIRHUSSAINMEPINDUSTRY 2 месяца назад

    Appriciated, excellent videos. No videos available on website regarding the obstruction

    • @NFPAJoe
      @NFPAJoe 2 месяца назад

      Thank you !

  • @chrisquickfall2301
    @chrisquickfall2301 2 месяца назад

    Awesome content. Thanks Joe.

    • @NFPAJoe
      @NFPAJoe 2 месяца назад

      Thank you 😎👍

  • @MohammedIbrahim-ql1wh
    @MohammedIbrahim-ql1wh 2 месяца назад

    Ohh man, thanks..❤❤

    • @NFPAJoe
      @NFPAJoe 2 месяца назад

      Your welcome ! 😎👍

  • @sebastianlealurquiola5905
    @sebastianlealurquiola5905 2 месяца назад

    Buddy…. You're the man. You have been so helpful.

    • @NFPAJoe
      @NFPAJoe 2 месяца назад

      Thank you!! I appreciate that and happy to hear 😎👍

  • @user-ny2zs8he3g
    @user-ny2zs8he3g 2 месяца назад

    Nice work Joe Joe you got the Automatic Hand book ? Its better than the standard npfa13.

    • @NFPAJoe
      @NFPAJoe 2 месяца назад

      Thanks ! Yes I have a membership with NFPA codes online!

  • @Ibn-Abdul-Barr
    @Ibn-Abdul-Barr 3 месяца назад

    Thanks Joe it’s refreshing how clearly you explain things. I think you would put these kinds of videos more often

    • @NFPAJoe
      @NFPAJoe 3 месяца назад

      Your welcome and thank you for the comment. I’m working on a video now on the 3 and 4 times rule. I’m trying to get a video out every 2 weeks,this one I’m working on has taken alittle longer. Should be done soon !

  • @albertcollazo3548
    @albertcollazo3548 3 месяца назад

    Thanks bro!

    • @NFPAJoe
      @NFPAJoe 3 месяца назад

      No problem!

  • @austinhologroski
    @austinhologroski 3 месяца назад

    What's the rule when say there's only two steel beams affecting a line in obstructed construction? When can the sprinklers return to 1-12 below deck?

    • @NFPAJoe
      @NFPAJoe 3 месяца назад

      You should go back to 1-12” below the deck as soon as the beams that are above the heads are spaced over 7’-6” on center. You could keep them at 1”-12” down even if it is obstructed construction as long as the spray pattern isn’t obstructed by the beams. You can figure that out using the beam rule. Going 1-6 inches below the structural members, max 22” is just an option. Let me know if this helps !

    • @austinhologroski
      @austinhologroski 3 месяца назад

      I only have two beams about 20" in depth and 5' apart that run horizontally across the center of the branch line. One head falls directly under the pocket of the beams and the rest of the heads on the line are spaced 8' spart. My question is what distance can I go back to 1-12 on the other side of the beams? The next head after the beam is 3'9 from the side if it. Can I run that head and the rest down the line at 1-12"?

    • @NFPAJoe
      @NFPAJoe 3 месяца назад

      @@austinhologroski yes! Sounds like you can run that head and the rest down the line at 1”-12”.

    • @austinhologroski
      @austinhologroski 3 месяца назад

      @@NFPAJoe thanks 👍

  • @danielgarcia3085
    @danielgarcia3085 3 месяца назад

    FPE here, you got yourself a new subscriber! Loving your videos.

    • @NFPAJoe
      @NFPAJoe 3 месяца назад

      Awesome, thank you!

  • @firedemon0823
    @firedemon0823 3 месяца назад

    Well done bro.

    • @NFPAJoe
      @NFPAJoe 3 месяца назад

      Thank you !

  • @user-ny2zs8he3g
    @user-ny2zs8he3g 3 месяца назад

    Smart way you put it Joe , I like this .

    • @NFPAJoe
      @NFPAJoe 3 месяца назад

      Thank you 😎🤙

  • @muhammadaleem1868
    @muhammadaleem1868 4 месяца назад

    Excellent explanation. thumbs up

  • @jetsgang5266
    @jetsgang5266 4 месяца назад

    A Joe wondering can you do video on above and below sprinkler heads when add when not?

    • @NFPAJoe
      @NFPAJoe 4 месяца назад

      Hey! Yea that’s a good topic 👍.

    • @user-ny2zs8he3g
      @user-ny2zs8he3g 4 месяца назад

      @jetsgang It applies in wood structure ceiling ( or combustible insulation ) you got to protect both. Or when there is 2 sets of wood joists.

    • @NFPAJoe
      @NFPAJoe 4 месяца назад

      Above and below coverage can have a lot of different situations. Definitely can be because of combustible construction above the ceiling like mentioned or could be for cloud ceilings, or slatted ceilings. Are you in any of these or putting heads above and below obstructions like duct work ?

    • @jetsgang5266
      @jetsgang5266 4 месяца назад

      @@NFPAJoe the duct takes up almost whole room it’s was a electrical room duct was tight to concrete deck so head is obstructed…it no Ceiling in room all uprights it didn’t make sense me cuz we only added 1 head above on one side of room meaning that head was blocked from deck it’s not going spray the other side of the room

    • @jetsgang5266
      @jetsgang5266 4 месяца назад

      @@NFPAJoe I wish I could just show u pic so you would understand more see it then we use 155 I thought electrical rooms normally 200

  • @user-ny2zs8he3g
    @user-ny2zs8he3g 4 месяца назад

    Nice work Joe. It pretty much applies for ESFR , CMDA, CMSA application. I am actually showing that in every drawing I send in the field, for guys to keep an eye while they installing

    • @NFPAJoe
      @NFPAJoe 4 месяца назад

      Thanks ! Awesome idea to have it on the install prints for reference. 😎👍

    • @user-ny2zs8he3g
      @user-ny2zs8he3g 4 месяца назад

      @@NFPAJoe Yeap,.. been a fitter in the past I know if we make it easy for the field guys and informative , less mistakes and better results are made.

  • @user-ny2zs8he3g
    @user-ny2zs8he3g 4 месяца назад

    Guys hurry the fuck up the foreman is here :)

    • @NFPAJoe
      @NFPAJoe 4 месяца назад

      Hahaaa 😎👍

  • @user-hj5cm6cg7r
    @user-hj5cm6cg7r 4 месяца назад

    👍

  • @user-ny2zs8he3g
    @user-ny2zs8he3g 4 месяца назад

    Joe you a foremen , project manager.? . I worked in the field for about 11 years then another 8 design took a break for 3 years now I m back 6 months Are you on Instagram how can I contact you ?

    • @NFPAJoe
      @NFPAJoe 4 месяца назад

      Heyyy. I am currently a foreman. I’ve been in the field since 2005 and I have been a trainer at local 550 training center for 5 years as a second job. You can email me at sprinklahfittah@yahoo.com

    • @user-ny2zs8he3g
      @user-ny2zs8he3g 4 месяца назад

      @@NFPAJoe I can tell from the tone of your voice . I started in the field 97 but I been taking time off few years here and there , however I was lucky to work with a good foreman like yourself in service. He had my hands on in every dry pipe that exist out there. Internal resets were fun back in the days.

    • @jetsgang5266
      @jetsgang5266 4 месяца назад

      A Joe was wondering can you do video on above and below sprinkler heads my foreman has me adding bunch heads just for nothing

  • @user-ny2zs8he3g
    @user-ny2zs8he3g 4 месяца назад

    I have seen this before but seem to apply only to certain unique application. This sprinkler design would not be compatible in high pile storage .

  • @user-ny2zs8he3g
    @user-ny2zs8he3g 4 месяца назад

    I remember back in the days we had to cut that by hand on the vice. It s nice to see technology has made things easier but probably not as much fun as the old days

    • @NFPAJoe
      @NFPAJoe 4 месяца назад

      Yes we have a 6” to 8” manual pipe cutter onsite. If I don’t have the hydraulic cutter and groover available I will score the pipe with the manual cutter and then use a bandsaw to finish

    • @user-ny2zs8he3g
      @user-ny2zs8he3g 4 месяца назад

      @@NFPAJoe that sounds right. Let me introduce myself . Martin. Joe how s the union in Boston still a thing or not. In NYC not as strong as used to. Most shop are converted to non union

    • @NFPAJoe
      @NFPAJoe 4 месяца назад

      @@user-ny2zs8he3g Hey Martin. Thanks for the interest in the channel. Working on a new video now on obstructed/unobstructed construction should be a good one. Bostons unions are strong 💪. Work is looking good as far as I can see.

  • @mian114
    @mian114 4 месяца назад

    Informative.

  • @user-ny2zs8he3g
    @user-ny2zs8he3g 5 месяцев назад

    Joe where you located mind asking . I was a install and repair guy for 10 years in Brooklyn Ny now doing design for 12 but live in Oregon still work for my NY shop

    • @NFPAJoe
      @NFPAJoe 5 месяцев назад

      Heyy. Located in Boston Massachusetts

    • @user-ny2zs8he3g
      @user-ny2zs8he3g 5 месяцев назад

      @@NFPAJoe Last time been there 6 months ago.

  • @user-ny2zs8he3g
    @user-ny2zs8he3g 5 месяцев назад

    This distinguishing is always useful, good job Joe.

    • @NFPAJoe
      @NFPAJoe 5 месяцев назад

      Thanks !

  • @user-ny2zs8he3g
    @user-ny2zs8he3g 5 месяцев назад

    Joe a question for you , if you happen to know ,. I hear that black pipe in many jobs used on dry system. Galvanized only in ESFR jobs or big heads but I can't find anywhere that's describes specifically what's k factor size or at what point should use galvanized in dry system.

    • @NFPAJoe
      @NFPAJoe 5 месяцев назад

      Heyy sorry for the late reply. So the option to use Galvanized pipe has nothing to do with code. It’s an option offered to have your sprinkler system last longer. During the sales process of having a sprinkler system installed you could choose to have black schedule 10 or 40. You could add a nitrogen system to help keep moisture out of the pipe. Or you could most commonly use galvanized pipe, and the only reason would be to have the pipe last longer before rotting out due to moisture.

    • @user-ny2zs8he3g
      @user-ny2zs8he3g 5 месяцев назад

      @@NFPAJoe thank you so much brother