- Видео 395
- Просмотров 848 215
PowerPlant By BS Rathore
Индия
Добавлен 25 мар 2012
I Bhagwan Singh Rathore, B.E(Mech.)/MS(Energy and Environment) i am An operation engineer with more than 7 years of experience in supercritical thermal powerplant And worked on 110 MW 210MW 660MW Units
Here you can find various knowledgeable videos about Thermal power plant operations and can get to know how things work in a power station
You can put your queries in comment box or inbox me on instagram i will try to help you.
Here you can find various knowledgeable videos about Thermal power plant operations and can get to know how things work in a power station
You can put your queries in comment box or inbox me on instagram i will try to help you.
LPH Low pressure heaters ll working construction and procedure
Join this channel to get access to perks:
ruclips.net/channel/UCaYF8wlzL1766y1CUMAqXKgjoin
REGENERATORS or LPH
A low pressure heater (LPH) is a shell-and-tube heat exchanger that uses steam from a turbine to heat condensate water in a power plant. LPHs can be installed vertically or horizontally, depending on the plant's design.
ruclips.net/channel/UCaYF8wlzL1766y1CUMAqXKgjoin
REGENERATORS or LPH
A low pressure heater (LPH) is a shell-and-tube heat exchanger that uses steam from a turbine to heat condensate water in a power plant. LPHs can be installed vertically or horizontally, depending on the plant's design.
Просмотров: 165
Видео
CEP ll Working start up and construction of condensate extraction pump
Просмотров 46114 дней назад
In this video I Bhagwan Singh Rathore(5 yrexperienced in operations) tried to explain the light up procedure of 660MW Supercritical thermal power plant In this part we learn overview of plant and how to run / start CEP(condensate extraction pump) Timestamp
Vacuum Pump ll Working When Why and How to start ll Thermal Powerplant
Просмотров 323Месяц назад
Join this channel to get access to perks: ruclips.net/channel/UCaYF8wlzL1766y1CUMAqXKgjoin
Ejector vacuum system ll Concept and starting procedure Powerplant
Просмотров 206Месяц назад
Join this channel to get access to perks: ruclips.net/channel/UCaYF8wlzL1766y1CUMAqXKgjoin
Working Of Steam Turbine
Просмотров 3542 месяца назад
Join this channel to get access to perks: ruclips.net/channel/UCaYF8wlzL1766y1CUMAqXKgjoin
Condenser Vacuum ll How it increases efficiency
Просмотров 2862 месяца назад
Join this channel to get access to perks: ruclips.net/channel/UCaYF8wlzL1766y1CUMAqXKgjoin
Hotwell And placement of Condenser LPH Ejector vacuum breaker LPDFT gsc csc
Просмотров 2972 месяца назад
Hotwell And placement of Condenser LPH Ejector vacuum breaker LPDFT gsc csc
Biasing input in coal feeders ll air ll feedwater ll Id fan ll Fd fan ll Pa fan
Просмотров 1332 месяца назад
Biasing input in coal feeders ll air ll feedwater ll Id fan ll Fd fan ll Pa fan
How coal Generates electricity ll Working of a thermal power plant
Просмотров 2452 месяца назад
How coal Generates electricity ll Working of a thermal power plant
Lay Out Of A Thermal Powerplant ll Powerplant Engineering Introduction
Просмотров 1723 месяца назад
Lay Out Of A Thermal Powerplant ll Powerplant Engineering Introduction
Thermal powerplant introduction ll Story of worlds first engine
Просмотров 1553 месяца назад
Thermal powerplant introduction ll Story of worlds first engine
Powerplant Introduction ll Power generation
Просмотров 3254 месяца назад
Powerplant Introduction ll Power generation
Why did Capacitors and Reactors used in Power Grid
Просмотров 2065 месяцев назад
Why did Capacitors and Reactors used in Power Grid
Thermal power plant Engineers destination
Просмотров 1986 месяцев назад
Thermal power plant Engineers destination
How a coal mill looks inside view
Просмотров 1,4 тыс.6 месяцев назад
How a coal mill looks inside view
Generator capability curve And Relation between Mvar and Mw
Просмотров 6937 месяцев назад
Generator capability curve And Relation between Mvar and Mw
Power Factor ll Active power Mw and Reactive Power Mvar
Просмотров 8037 месяцев назад
Power Factor ll Active power Mw and Reactive Power Mvar
Switchgear and Auxiliary Power Supply for 110mw Powerplant
Просмотров 2858 месяцев назад
Switchgear and Auxiliary Power Supply for 110mw Powerplant
How to Open and Close Isolators and Circuit Breakers
Просмотров 2338 месяцев назад
How to Open and Close Isolators and Circuit Breakers
Synchronisation of two power bus ll Charging line feeders
Просмотров 1838 месяцев назад
Synchronisation of two power bus ll Charging line feeders
Switchyard of a powerplant ll Transformers and Feeder lines
Просмотров 4519 месяцев назад
Switchyard of a powerplant ll Transformers and Feeder lines
What is the Grid Frequency ll Elecrical Power grid
Просмотров 5429 месяцев назад
What is the Grid Frequency ll Elecrical Power grid
Load Control By DROOP RGMO and FGMO ll Power Grid in India
Просмотров 3,1 тыс.9 месяцев назад
Load Control By DROOP RGMO and FGMO ll Power Grid in India
Power Grid in India ll Generation and Load
Просмотров 4969 месяцев назад
Power Grid in India ll Generation and Load
Wind Turbine Generators #windturbine
Просмотров 769 месяцев назад
Wind Turbine Generators #windturbine
Boiler Safety Valve and Pressure at which it opens
Просмотров 2569 месяцев назад
Boiler Safety Valve and Pressure at which it opens
Osm, Sir Please keaped up ❤
Sir DCS General Electric (GE)
Group 😊🎉😊 hy ❤uall
Sir why continuous vent in LPH open in condenser, and continuous vent of HPH open in dearator?
Are you talking about drip water ?
Air vent is provided for remove continuously non condensable gases from HPH & LPH to condenser
Kuch plant mein isse operational vent bhi kehte hai magar HPH ka dearator mein jata hai aur LPH Ka condenser mein jata hai
@@BhagwanSRathore Nai Sir, operational vent, continuous vent kehte hai, air vent
Thanks for sharing the knowledge
Hello sir please one video aux boiler light up kashe karte hai
Sure sir 👍
Ha sir ye Mera bhi need hai sir... please
They need to close the steam channels right away
Cep we need moor videos on this pump
Look at the shitty air quality in the area? No thank you.
Through your ACs EVs out so we need not burn coal anymore
Sir job lgwa do
I will update if there any vacancy
Thanks, very useful video...
♨️🌐🌋
Sir i want to ask you something... Sir i dont have triple 60 and my age is 26..i am working in a 8 mw afbc boiler in operation department...but i want to go for npti..sir is it good to go there.. Sir kaha jaau kya kru?? please guide me little bit sir.requesting you
If you are already working in a powerplant you do not need to join npti or other training institutes just gain experience there and also try to catch opportunities in adani tata reliance pp
Respected sir your lectures are really superb as always.. Sir i want to ask you something about creer related sir?sir can i ask you
Sir i want to ask you that is there any opportunity for freshers btech in mechanical engineering....sir is there any vendors for btg area.. respected sir i am really struggling to find a job..now i am in 8 mw boiler afbc as GET...sir i want to switch... Sir i requesting you to please reply to me...
CEP
Steam turbine am I right
Thanku sir👍
Thank you🤗
Sir in steam jet Ejector why syphon is used in inter condenser & after condenser drain line ?
Syphon provides sealing by maintaining water inside it so in any case there will be no air ingress in condenser
Esh bgm tone ka name kya hai
Dahej mey hai
E s p please provide video upload
sir mera ho sakta hai thermal power plant mai. sir mera dream hai thermal power plant mai work kerne ka.
Ji bilkul ho skta hai
@@BhagwanSRathore sir mai bahut try kya hu but is field mai fresher hu isliye kahi ho nahi pa raha hai. aapke video acche lagte hai.
Koi training institute join kar lo like adani ntpc cbip reliance etc fir vha se achhe moke aayenge abhi rajasthan me 3 4 powerplant aayenge but inme exam hoga technical syllabus
@@BhagwanSRathore sir mai UPPCL ki preparation ker raha tha. 2 bar 1, 0.5 no se final merit mai nikal gaya. uske baad private job mai aya hu. ab job ke sath preparation continue kerna ha kyuki vacancy ane mai kafi time lagta hai.
Full video upload please
Bahut badhiya
Good
New join
Cool water slide
Very nice sir, very helpful
is it safe to give oil in service,when furance and oxygen are not within permissible limit,danger of explosion in 2nd pass exist in 500 MW tangentail fired boiler
Oxygen should be more than 2 % is safe
sir mera ho sakta hai thermal power plant mai
Sir can we run unit full load with one FD FAN, what parameters we should watch
Sir may you share screenshot of auto controls loop (running at load above 50%)
sir aapka no mil sakta hai online help ke liye
In 250 Mw When one id fan trip then one fd fan also trip.In this situtation can be take oil gun for prevention of flame intensity
Yes you can take oil guns as id fd triping also trips an fuel elevation
this lecture is very helpful to us .first time in mahagenco we run supercritical 660 mw . this lectures are very useful .please make detail video on control loop of seperator level control (dry and wet mode condition) also the function of BRP
Already uploaded on channel plz explore the playlist
Bhai kam milega electrician 💡 kam iti hai or ex,p bhi hai
to thk kese karein ??
हाथ लगा के चेक करो वाइब्रेशन फील हो रहा है चारो सेंसर में तो वायरिंग में इश्यू है या जिसमें वाइब्रेशन nhi aa रहा उसको चेंज करो
mere sir isi plant mai job kerte hai
Sir...please 1 lecture on DCDB system and UPS,Battery
Thank you sir
Why this parameter archive eco inlet feedwater temperature and high pressure heater outlet difference more than 10deg during wet to dry mode change over
Sir kaun se type ka vaccum pump hai... Water ring type hai kya
Yes
Nice explanation...
Thanks
Sir prds working principle kya hota hai
Already uploaded on channel plz watch light up procedure playlist
ruclips.net/video/Ob_M-gfcFxg/видео.html
@@BhagwanSRathore ty sir
Ejector or hoger me kya different h....kon sa jayad effective h...
@@manohardhaker423 ejector holding aur hogger me kya work principle hai
Scary height..😅
Very true
Silicon khul gaya
Pessenger se gaila
I HAVE A REQUEST FROM YOU SIR, PLEASE MAKE A VIDEO ON MARGINAL CONTRIBUTION. PLEASE SIR, YOUR TEACHING STYLE VERY NICE, UNDERSTAND VERY WELL
Free fire 🔥
The real one
Milta power
Why LPH-1 kept in Condenser and why Use drain cooler..
Lp turbine exhaust steam has some heat which can be extracted by using LPH and drain coolers help increase condensate temp and cool down the drain so it can be reused