I GOT SO MUCH ABUSE ON THIS JOB! 😱
#TopElectrician #fusebord #Electrician #apprentice #electric #consumerunit #renewables #electrician #testing
LET ME DO MY JOB! In maybe our most dramatic episode yet, I am working on a house renovation in York. We're first fixing and second fixing in one fell swoop. We've got numerous sockets to drill out and wire up for the new kitchen renovation. Throughout the rest of the house we're focused mainly on the lighting, replacing most downlights and pendant lights respectively. Not only do the neighbours start beefing with me, I also got abused by some scammer on the phone so all in all its been an eventful project! 😅
If you enjoy this type of content, hit like, leave a comment, and press su...
Просмотров: 816

Видео

HOW TO WIRE A HOUSE EXTENSION! 🏠⚡
Просмотров 1,6 тыс.День назад
#TopElectrician #fusebord #Electrician #apprentice #electric #consumerunit #renewables #electrician #testing SO EASY! In this video, myself and Ellis are going to show you how to wire a home extension on one of our easiest jobs to date. This first fix consists of 6 sockets and 8 downlights. Super simple job, just a matter of extending the ring and tying everything up on a 3 gang switch. Comment...
I HATE PLASTERERS! 🤬
Просмотров 1 тыс.14 дней назад
#TopElectrician #fusebord #Electrician #apprentice #electric #consumerunit #renewables #electrician #testing PLASTERERS 😡 In this week's episode, myself, Brian, Jonah, and Ellis are all working on a second fix for a property however the plasterers have made life very difficult for us. We've come back to the job to find that the plasterer has plastered over one of our sockets completely and just...
AWESOME KITCHEN INSTALL! ⚡
Просмотров 83421 день назад
#TopElectrician #fusebord #Electrician #apprentice #electric #consumerunit #renewables #electrician #testing FIRST FIX MASTERCLASS! In this episode, myself, Jonah & Brian are working together on this kitchen first fix. There's a bunch of downlights to install so we'll show you how to do that. Whilst taking out the old lights we notice a few of them were all crispy and could have been a real fir...
THEY CAN'T KEEP GETTING AWAY WITH THIS!🔌⚡
Просмотров 893Месяц назад
#TopElectrician #fusebord #Electrician #apprentice #electric #consumerunit #renewables #electrician #testing DODGY WIRING! We have 2 jobs this week and both of them feature dodgy wiring! Kicking off with the zappi EV charger installation, the fuse board had loads of exposed copper and dodgy feeds but now we've got everything all nice, neat and sweet. Then we went on to a school where all the em...
SECOND FIX KITCHEN DONE RIGHT! ⚡🔌
Просмотров 431Месяц назад
#TopElectrician #fusebord #Electrician #apprentice #electric #consumerunit #renewables #electrician #testing ROUND 2! We are back at this property from a couple weeks ago, you may remember. We did the first fix and now we are on with the second fix electrics. We'll be fixing all the sockets, wiring up all the appliances as well as installing the JCC downlights. There wasn't enough space for a j...
HOW TO INSTALL A TETHERED ZAPPI CHARGER! ⚡🔋
Просмотров 406Месяц назад
#TopElectrician #fusebord #Electrician #apprentice #electric #consumerunit #renewables #electrician #testing TRICKY WIRING! In this episode we are installing a tethered Zappi EV charger, something that's usually straightforward but it was one hell of a task getting the cables to run from the drive, all the way through the house and into the fuse board. I even had to get the customer to give me ...
FIRST FIX DONE RIGHT! 🔌⚡
Просмотров 2,1 тыс.Месяц назад
FIRST FIX DONE RIGHT! 🔌⚡
WE TRIED AN ESCAPE ROOM! 😱
Просмотров 2302 месяца назад
WE TRIED AN ESCAPE ROOM! 😱
EICR REMEDIAL MASTERCLASS! ⚡
Просмотров 5772 месяца назад
EICR REMEDIAL MASTERCLASS! ⚡
CUSTOM LED STRIP LIGHTING! 💡⚡
Просмотров 3722 месяца назад
CUSTOM LED STRIP LIGHTING! 💡⚡
RUNNING AN ELECTRICIAN BUSINESS!⚡👨‍💼
Просмотров 7782 месяца назад
RUNNING AN ELECTRICIAN BUSINESS!⚡👨‍💼
ULTIMATE GUIDE TO EICR TESTING!⚡🔌
Просмотров 1,4 тыс.2 месяца назад
ULTIMATE GUIDE TO EICR TESTING!⚡🔌
HOW TO INSTALL A TESLA EV CHARGER! 🚘⚡
Просмотров 2,6 тыс.3 месяца назад
HOW TO INSTALL A TESLA EV CHARGER! 🚘⚡
TINY CAFE TESTING!⚡🍵
Просмотров 5863 месяца назад
TINY CAFE TESTING!⚡🍵
HOW TO INSTALL AN UNTETHERED ZAPPI CHARGER! 🚗⚡
Просмотров 6003 месяца назад
HOW TO INSTALL AN UNTETHERED ZAPPI CHARGER! 🚗⚡
HOW TO RUN YOUR BUSINESS WITHOUT YOU! 👨‍💼 📈
Просмотров 2833 месяца назад
HOW TO RUN YOUR BUSINESS WITHOUT YOU! 👨‍💼 📈
DAY IN THE LIFE OF A TOP ELECTRICIAN! ⚡
Просмотров 5744 месяца назад
DAY IN THE LIFE OF A TOP ELECTRICIAN! ⚡
THIS HAS NEVER HAPPENED BEFORE! 😱
Просмотров 6064 месяца назад
THIS HAS NEVER HAPPENED BEFORE! 😱
NEW APPRENTICE HAS A GO!⚡😯
Просмотров 5114 месяца назад
NEW APPRENTICE HAS A GO!⚡😯
THIS TRICK MAKES TESTING EASY! 🔌⚡
Просмотров 2 тыс.4 месяца назад
THIS TRICK MAKES TESTING EASY! 🔌⚡
THIS TINY FLAT HAD MASSIVE PROBLEMS! ⚡🔌
Просмотров 9675 месяцев назад
THIS TINY FLAT HAD MASSIVE PROBLEMS! ⚡🔌
INCEPTOR MILLI - THE PERFECT DOWNLIGHT!?⚡💡#ad
Просмотров 4165 месяцев назад
INCEPTOR MILLI - THE PERFECT DOWNLIGHT!?⚡💡#ad
THIS DEFINITELY NEEDED TESTING! ⚡🏠
Просмотров 6745 месяцев назад
THIS DEFINITELY NEEDED TESTING! ⚡🏠
EICR TEST EXPOSED THIS HOME!⚡🔌
Просмотров 1,5 тыс.5 месяцев назад
EICR TEST EXPOSED THIS HOME!⚡🔌
KITCHEN 2ND FIX ELECTRICS! ⚡💡
Просмотров 3856 месяцев назад
KITCHEN 2ND FIX ELECTRICS! ⚡💡
⚽ SOCCERTRADE:⚡ELECTRICIANS V. PLUMBERS💦
Просмотров 2666 месяцев назад
⚽ SOCCERTRADE:⚡ELECTRICIANS V. PLUMBERS💦
BACK TO WINNING WAYS @ ELEX SHOW 2024! 🥳🎉
Просмотров 6366 месяцев назад
BACK TO WINNING WAYS @ ELEX SHOW 2024! 🥳🎉
HOW TO WIRE A HEATING SYSTEM! (S-PLAN) 🔥⚡
Просмотров 8556 месяцев назад
HOW TO WIRE A HEATING SYSTEM! (S-PLAN) 🔥⚡
FAULT FINDING CRASH COURSE! ⚡😁
Просмотров 1,8 тыс.7 месяцев назад
FAULT FINDING CRASH COURSE! ⚡😁

Комментарии

  • @dibertnz415
    @dibertnz415 12 часов назад

    Mental math is always hard 13:16 haha

  • @dibertnz415
    @dibertnz415 12 часов назад

    Nice 👍

  • @AngelaPeters-fy1tc
    @AngelaPeters-fy1tc 3 дня назад

    Excellent content again,nice tip on the downlight hole maker thing. ive watched the first fix and it was very interesting just got slightly confused on where the 2 bundles of 2.5 mm t&e where going. Did you do a standard ring as in point to point or did you do a balanced ring? Really interesting very good content indeed young man. Keep up the good.

  • @AngelaPeters-fy1tc
    @AngelaPeters-fy1tc 4 дня назад

    Excellent content again full of good stuff, technical and comedy all in one. what depth do you chase your walls for the 2.5 mm T&E cable just as a matter of interest? Liking your style, and you made me salivate with that steak and chips, good job again thankyou.

  • @marveldcfanedit7240
    @marveldcfanedit7240 4 дня назад

    Makes me laugh it be different if you're doing the work for them these people seem to think that you drill as a silent button on it

    • @finneyelectrical
      @finneyelectrical 2 дня назад

      Yeah they are nuts! 10-3 working hours haha and I better not start till then. Some people are not realistic, definitely when it’s once every ten year for a 2 week Reno 😂 you a sparky?

  • @davidshaw9142
    @davidshaw9142 5 дней назад

    I was putting up a 30w led PIR to cover rear entrance 2 floors and a neighbour who lives 38 metres away(i measured distance shouted me off the ladders and screamed at me to turn it off as its hurting her eyes😂😂 i said dont look at it then, and i told her there are another 2 goind up either side, she said i am not putting any more up, 😂😂 i put the other 2 up

    • @finneyelectrical
      @finneyelectrical 4 дня назад

      Haha 😜 it’s bad ain’t it when it’s nothing to do with you. Deal with the customer if you have a problem, unless you want to pay for today’s wage to make me leave 😂 were they old?

    • @davidshaw9142
      @davidshaw9142 4 дня назад

      @finneyelectrical yeah OLD,,it's funny you mentioning wages as I was going to say to her pay my days wage and I will go then, by the way you are right I keep the scammers in the phone now and do silly voices to them as it is preventing them getting to the vulnerable

  • @dsmale7067
    @dsmale7067 5 дней назад

    Great video, York is a pain for parking, had day out there this year so recognise where you are working, 👍

    • @finneyelectrical
      @finneyelectrical 4 дня назад

      Yeah nightmare! You could park in the Sainsbury’s for cheap but it’s just 2 hours now! Had to take the parking fine when we had our staff do 😢 didn’t have time to re park

  • @YoungBobby98
    @YoungBobby98 5 дней назад

    The longer video is a treat, so much chaos in one video. You handled it all like a pro👌🏻that scammer had enough, my man isn’t getting that commission or bank details💀😂class video as always mate! Gotta ask, when fitting those down-lights, do you install new wiring or do you use the old wiring and just slap them in a waygo/junction box and simply link them through the waygos?. Again Finney, class video which killed me😂keep up the ace work and keep your head up my man cause you’re smashing it👌🏻

    • @finneyelectrical
      @finneyelectrical 4 дня назад

      Thank you Bobby! Man of many kind word’s 😎 yeah I can’t stand the scammers! But me they shouldn’t have my number and 2 I’m going to waste their time so they don’t scam anyone else. So I Wago box the cable coming through to the new down lights in and out. Had to cut a few access holes to get the cables through which took some time. Might be the staff do next video 😂 can’t remember what I’ve filmed

  • @billybulmer7386
    @billybulmer7386 6 дней назад

    You on Aldwalk this week?

    • @finneyelectrical
      @finneyelectrical 4 дня назад

      Not sure what it’s called, just down the side of your move 😁

    • @billybulmer7386
      @billybulmer7386 4 дня назад

      It’s a nice part of York, just a shame about some of the residents!👿

  • @willuk2000
    @willuk2000 7 дней назад

    What size gland did you need for the armoured cable to the Tesla wall connector? I think most glands for 6mm/3-core SWA/armoured cable all seem to be 20mm - would you recommend an insert to try and take this from 20 to 25mm+ or just a different type of gland - any recommendations? Thank you for the video - looks a tidy install 😎

    • @finneyelectrical
      @finneyelectrical 4 дня назад

      Sure I replied to this haha 25mm just fits I think. 25mm plastic compression for Tesla side as you don’t want to export the houses earth. 20mm armoured good on the inside. Cheers for watching!

  • @thesteve142gaming7
    @thesteve142gaming7 9 дней назад

    Just a quick one, you pulling the lighting circuit onto rcd is it not a requirement to have the rcd upgraded to type A as you have install new wiring? Keep up the good work cheers

    • @finneyelectrical
      @finneyelectrical 9 дней назад

      Heya the Steve! Cheers for the watch and subscribing. So the requirement is if it’s going to go over 6ma dc it will blind a normal type AC RCD. This is a tiny house so will never go over that so the existing RCD is fine. You should measure it though with a dc clamp meter with everything on 👌

    • @thesteve142gaming7
      @thesteve142gaming7 9 дней назад

      @ nice one appreciate it mate

  • @benfearn702
    @benfearn702 10 дней назад

    Very down to earth, helps older newbies like myself to see what happens in real life work

    • @finneyelectrical
      @finneyelectrical 9 дней назад

      Ah cheers Ben! Are you retraining? I try to keep these very real world, there’s a lot of fake accounts that just post their best work but it doesn’t always end up that sweet most days haha

  • @AngelaPeters-fy1tc
    @AngelaPeters-fy1tc 10 дней назад

    Excellent video, that crispy white JB was that a ceiling rose doubling as a JB and what happened had the old cable been arcing you probably said but I was munching sweet chilli sensations crisps and maybe missed it. Great content keep them coming.

    • @finneyelectrical
      @finneyelectrical 8 дней назад

      Haha can beat the sweet chilli!

    • @finneyelectrical
      @finneyelectrical 8 дней назад

      So they are old style “pork pie” junction boxes, usually has 4-5 screw terminals in. They are a ok to use if you can get access to them but aren’t a maintainable connection so can’t just hide these to get plastered over. I much prefer the ago boxes and Wago connectors

  • @AngelaPeters-fy1tc
    @AngelaPeters-fy1tc 11 дней назад

    Great content thanks, keep up the good work.

    • @finneyelectrical
      @finneyelectrical 9 дней назад

      Cheers Angela! Are you an electrican yourself?

  • @fitfreddiesforum
    @fitfreddiesforum 11 дней назад

    rented property 5 yrs ok what if the property has several tenant lets in that period . should be done on each let

    • @finneyelectrical
      @finneyelectrical 11 дней назад

      It does say change of occupancy but no landlord is going to let that fly 😂 most try get away with the bare minimum. This was a property to sell so 10 year as it’s owned not rented

  • @JIBS.
    @JIBS. 12 дней назад

    Still my favourite electrician on RUclips.

    • @mrskhepple
      @mrskhepple 11 дней назад

      Ditto ❤️

    • @finneyelectrical
      @finneyelectrical 11 дней назад

      Cheers JIBS! Keeps me going 💪 thanks for commenting too, helps push out to more people, not easy to grow when the next biggest is on a few hundred thousand subs haha it’s not about the numbers as I love doing the vids, but would be nice to do give aways!

    • @finneyelectrical
      @finneyelectrical 11 дней назад

      Thank you Mrs hepple!

  • @billybulmer7386
    @billybulmer7386 13 дней назад

    👍👍👍

    • @finneyelectrical
      @finneyelectrical 11 дней назад

      Cheers billy! Hope you’re not in the floody area in York. Had a nightmare in traffic on Haxby road today. Took 40min to travel a usually 7min drive!

    • @billybulmer7386
      @billybulmer7386 11 дней назад

      @ oh dear, sounds like you are not having a good day. Haxby road can be bad at the best of times. People queuing for the hospital on wiggy road doesn’t help matters though. I always try avoid that part of York if I can on an afternoon.

  • @Joe90Gallagher
    @Joe90Gallagher 18 дней назад

    Love a good rewire 😀 nice work brother

    • @finneyelectrical
      @finneyelectrical 18 дней назад

      This was a take over job so was a bit of a nightmare! Started blowing up at the end one of the circuits

  • @stepbackandthink
    @stepbackandthink 20 дней назад

    Having the boxes so far back was a bit ridiculous to start with.

    • @finneyelectrical
      @finneyelectrical 19 дней назад

      It’s a joke ain’t it! We got told to chase them in and returned to find all the walls had 70mm insulation 😂 cant trust customer 😂

  • @simonr1392
    @simonr1392 20 дней назад

    Great video until the RCD main switch! That's just a no no and all it's saved them is around £100 if that with Fusebox.

    • @finneyelectrical
      @finneyelectrical 19 дней назад

      On a budget, can’t all have money 💰 would have loved a clean sweep. Funny how some sparkies think everything has to be rcbo these days. The reg is if it’s going to go over 6ma dc, which non of these circuits can’t. A weird snobbery

    • @simonr1392
      @simonr1392 19 дней назад

      @@finneyelectrical I guess the issue is no one can see down the line as to how anything changes. I'm pretty sure it says that an RCD as main switch isn't right🤔

    • @finneyelectrical
      @finneyelectrical 19 дней назад

      @simonr1392 nah you can buy a garage board that’s literally this? There’s no way of the circuits we have on there will go over 6ma so will be good. Wouldn’t risk it with lighting though, too much with led lighting 😁

  • @GrahamWoodward-ww1zf
    @GrahamWoodward-ww1zf 20 дней назад

    Trades walking off site= alarm bells.

    • @finneyelectrical
      @finneyelectrical 19 дней назад

      💯 not the easiest customers but getting there

  • @billybulmer7386
    @billybulmer7386 20 дней назад

    Spam & egg! I have never ever seen that on offer in York and I hope it stays that way😂

    • @finneyelectrical
      @finneyelectrical 19 дней назад

      Yorks missing a trick, too nice 👌 you not tried it?

    • @billybulmer7386
      @billybulmer7386 19 дней назад

      Spam and egg?-- no, no and no!🤣

  • @enochabban8086
    @enochabban8086 20 дней назад

    Hi , mate Enoch watching live from Ghana

    • @finneyelectrical
      @finneyelectrical 20 дней назад

      Yes Enoch! Nice to have you comment and enjoy the video!

  • @YoungBobby98
    @YoungBobby98 20 дней назад

    Love the video, made me laugh within the first 2 minutes😂clean work as always my man!

    • @finneyelectrical
      @finneyelectrical 20 дней назад

      Cheers young Bobby for the comment! Love hearing feedback on the video. Was it the garden Halloween 👻 haha 😜

  • @tonywatson1412
    @tonywatson1412 21 день назад

    Laying against the wall. One hand in pocket , other hand with phone...bloody lazy looking , half awake fcuking sleeping beauty

  • @ian.M440
    @ian.M440 26 дней назад

    TOP electrician Nice work

  • @billybulmer7386
    @billybulmer7386 27 дней назад

    That is going to be one beautiful kitchen when it done👍👍

    • @finneyelectrical
      @finneyelectrical 21 день назад

      Going to look ace when it’s done, stay tuned for 2nd fix

  • @Ox0077-p7h
    @Ox0077-p7h 27 дней назад

    I thought r1+r2 is not required on an eicr, rather should do live test to get proper realistic Zs no ?

    • @finneyelectrical
      @finneyelectrical 15 дней назад

      Zs is just r1+r2 and your ze. So doing either is fine. But some would say not removing the circuits cpc from the met, doesn’t prove partallel paths. What you think?

  • @craigbutler6243
    @craigbutler6243 29 дней назад

    Great vid James. Does the tesla charger not have a CT device like other chargers & how do you connect it to the internet? Cheers

    • @finneyelectrical
      @finneyelectrical 29 дней назад

      Heya it’s got a Tesla app where you connect the charger through wifi

    • @finneyelectrical
      @finneyelectrical 29 дней назад

      No ct’s, just set load

  • @jasedeed8771
    @jasedeed8771 Месяц назад

    Good job... 👍...... Good video👍

  • @billybulmer7386
    @billybulmer7386 Месяц назад

    👍👍

  • @tedsims4601
    @tedsims4601 Месяц назад

    Brilliant video! ❤

  • @dsmale7067
    @dsmale7067 Месяц назад

    Any SPD ?

    • @finneyelectrical
      @finneyelectrical Месяц назад

      Was on the small db ❤️

    • @dsmale7067
      @dsmale7067 Месяц назад

      Cool 😎

    • @finneyelectrical
      @finneyelectrical Месяц назад

      @@dsmale7067 was a nice job this, I always quote remote from pictures, never go out to jobs to quote. This was clutch, ordered 10m and it only just reached with 2 inch spare 😂

    • @MICKY111able
      @MICKY111able 28 дней назад

      Doesn't the charge point need to be on its own dedicated rcd, not shared with other circuits?

    • @finneyelectrical
      @finneyelectrical 28 дней назад

      @ nope, just a double pole RCD and type A RCD 👌 SPD is even up to the customer but they have to opt out

  • @YoungBobby98
    @YoungBobby98 Месяц назад

    The electrical knowledge that this man possesses is almost frightening. Learning a lot from you, keep up the class work and videos as always😁👌🏻

    • @finneyelectrical
      @finneyelectrical Месяц назад

      Cheers young Bobby! Couldn’t believe the whole school had been wired wrong, bet they charged a fortune aswell!

    • @tedsims4601
      @tedsims4601 Месяц назад

      I've learnt a lot and I'm not even an electrican

  • @ergwa
    @ergwa Месяц назад

    Excellent job 🎉

  • @mandyf5441
    @mandyf5441 Месяц назад

    Must be satisfying to correct someone’s work

    • @finneyelectrical
      @finneyelectrical Месяц назад

      Satisfying getting paid to fix loads of issues and they use us in the future!

  • @YoungBobby98
    @YoungBobby98 Месяц назад

    Another brilliant video mate👌🏻inspiring me to push through this studying after work even though i’m always tired af😂keep up the ace work mate, top job & video as always!

    • @finneyelectrical
      @finneyelectrical Месяц назад

      Get it done! Sacrifice the now for your future self. Seeking short term pleasure screws up the future self. It will be worth it in the end young Bobby 😁 so you doing a night school then whilst being an apprentice?

    • @YoungBobby98
      @YoungBobby98 Месяц назад

      @ i’m doing a full time course whilst i work in the steel industry😭it’s difficult but i’m slowly getting there! I’m hoping to get an electricians mate role just so i can learn the practical side of things whilst i continue the theory of it all😁thanks for the wise words though, it helps me out a lot!😄

    • @AngelaPeters-fy1tc
      @AngelaPeters-fy1tc 3 дня назад

      @@YoungBobby98 Good man, hats off to you, you will get there.

  • @jdsarvang21
    @jdsarvang21 Месяц назад

    Can you please tell me the wire and box name you have used . Which wire we can use for outside light

    • @finneyelectrical
      @finneyelectrical Месяц назад

      Heya! Yes so any outside us protected 1mm or 1.5mm cable is fine for outside. The box is called a wiska box. 😁

    • @jdsarvang21
      @jdsarvang21 Месяц назад

      @ twin and earth cable is 1.5 but its not good for outside which one is good for weather protection

    • @finneyelectrical
      @finneyelectrical Месяц назад

      Don’t use twin, most ho7 cable is up protected but need to check with manufacture

  • @nimeshp3528
    @nimeshp3528 Месяц назад

    Awesome video, very informative, just what I needed. Love the style and edit great work overall. 👍🙏🏾

  • @billybulmer7386
    @billybulmer7386 Месяц назад

    👍👍

    • @finneyelectrical
      @finneyelectrical Месяц назад

      Thank you Billy! You don’t know any electricians in York do you wanting a job? Or one man bands wanting to be employed, sick of getting in work for themselves

    • @billybulmer7386
      @billybulmer7386 Месяц назад

      @ hi James, Thank you for the message. All the lads I know are either off the tools or have left the trade. We’re all of the age now whereby manual work is not really for us! Sorry not to be of help.

    • @finneyelectrical
      @finneyelectrical Месяц назад

      @billybulmer7386 might be some use, I might try find retired electricians to do a call answering service, so they answer on behalf of the company and answer any technical questions. The pass the info onto the office. Easy money 💰

  • @adriatikkrasniqi1453
    @adriatikkrasniqi1453 Месяц назад

    Nice work

  • @adamskiharvey3684
    @adamskiharvey3684 Месяц назад

    Daaaam, I'm glad I'm not the only one that's seen this same thing on 240v.

    • @finneyelectrical
      @finneyelectrical Месяц назад

      Shocking ain’t it! Daily this is

    • @adamskiharvey3684
      @adamskiharvey3684 Месяц назад

      @finneyelectrical I mostly work with DC and even see the same on that.

    • @finneyelectrical
      @finneyelectrical Месяц назад

      @adamskiharvey3684 shocking ain’t it 😂 must be loads of fires caused by bad workmanship

  • @thegrinch3691
    @thegrinch3691 Месяц назад

    I like your glasses mate where did you get them?

  • @derekwright2388
    @derekwright2388 Месяц назад

    I mean.... Haven't you heard of wirenuts? (yes I am being sarcastic)

  • @lucascox5996
    @lucascox5996 Месяц назад

    What size SWA did you use pal?

    • @finneyelectrical
      @finneyelectrical 29 дней назад

      6mm 3c

    • @willuk2000
      @willuk2000 7 дней назад

      What size/type of gland did you need for the 6mm 3c SWA? The cutouts for the cable entry look huge on the Tesla box (25-28mm) - was a regular IP rated gland okay as you’re not earthing the wire armour in this? All the regular 6mm 3core glands for armoured cable seem to be 20mm?

    • @finneyelectrical
      @finneyelectrical 7 дней назад

      Heya will! So you use a 25mm gland off the top of my head, you need the armouring for the mechanical protection but you don’t want to export the earth to the charger as you want the pen faults switched earth. So you use a plastic gland to provide electrical separation. And you earth the armoured braiding using the supplies earth

    • @willuk2000
      @willuk2000 7 дней назад

      @@finneyelectrical Thanks for the detail 😎 I wasn’t sure if the armour in the cable needed earthing at each end (to the PEN fault’s switched earth) but as the glands I have for the 6mm 3core SWA are only 20mm I think it would be difficult to fit in this unit anyway (if I use an adaptor to take these up to 25mm then it probably wouldn’t be possible to get a earth nut on the inside metal thread anyway!) I think a 25mm plastic IP rated gland would probably be easiest - and earth the armour to the supply earth, then earth the earth core in the cable to the PEN switched earth?

    • @finneyelectrical
      @finneyelectrical 6 дней назад

      You’ve got it! That’s the way you’re supposed to do it. Is it just garo you for for pen fault?

  • @YoungBobby98
    @YoungBobby98 Месяц назад

    What an intro, different from plumbers for a change💀😂

    • @finneyelectrical
      @finneyelectrical Месяц назад

      Totally they can be right cretins. Normally put up with half the box filled, but not this!

  • @raymurphy9749
    @raymurphy9749 Месяц назад

    Bill the customer , telling them they'll need to be reimbursed by the plasterers for your extra time and materials. Absolute fkin joke doing that to another man's work .

    • @finneyelectrical
      @finneyelectrical Месяц назад

      Yeah I will be doing! Total joke all the extra work. Made a right mess!

  • @stevenwhiting1424
    @stevenwhiting1424 Месяц назад

    Builders did this to me on a full house rewire in the kitchen, not only filled every box but also cut my wires short

    • @finneyelectrical
      @finneyelectrical Месяц назад

      Bad ain’t it! I’ll be billing the customer to bill the plasterer. They cut some cables short and pushed all the down lights above the insulation. Wouldn’t mind but never even met them! Think they didn’t like the client

  • @rjkelectrical6086
    @rjkelectrical6086 Месяц назад

    Out of interest why didn’t you install an SPD?

    • @Bazza-tn5ck
      @Bazza-tn5ck Месяц назад

      Section 443 states that surge protection should be installed where over voltage could result in serious injury or loss of life, so as the zappi uses PEN fault protection over voltage could cause degradation of the PEN fault protection device and cause it not to operate under loss of PEN conditions, therefore I believe surge protection is required.

    • @finneyelectrical
      @finneyelectrical 15 дней назад

      Just have to offer it

    • @finneyelectrical
      @finneyelectrical 15 дней назад

      You have to install SPD unless they opt out. It isn’t a requirement. Realistically, if there ever was multiple surges, the SPD will blow and be useless for the next surge as no one checks them. So I get why they aren’t set in stone like RCD protection. Nice point raised though

    • @rjkelectrical6086
      @rjkelectrical6086 15 дней назад

      @@finneyelectrical your wrong, you can only omit the need of an SPD if a risk assessment is carried out where transient over voltage is unlikely or the cost of fitting such a device out ways the damage caused to equipment connected.

    • @rjkelectrical6086
      @rjkelectrical6086 15 дней назад

      Pen fault protection isn’t used for over voltage, it’s used for a loss of the neutral conductor so in this instance the metal work would become live in a TNCS installation. Some manufacturers state an SPD must be fitted. So to comply with installation practices for the charger your fitting the customer not wanting it doesn’t cut the mustard 🤠👍

  • @Akz-xc1gu
    @Akz-xc1gu Месяц назад

    Why wouldn't you use a 10mm T&E in that trunking with a cat5 to a junction box and then the swa?

    • @finneyelectrical
      @finneyelectrical 15 дней назад

      Just a tidier job with ev ultra 👌 would have a joint box on the outside, also where it goes up the wall to db, that would look crap in a twin and earth with a data stuck to the side of it. Could have put some white trunking there but would have to be super wide due to the flat 90 bending radius