Engineering in Tamil
Engineering in Tamil
  • Видео 46
  • Просмотров 296 885
Tan delta test, Dissipation factor test, Loss angle for Transformer oil,Transformer testing in Tamil
@engineering in tamil
The Transformer Oil Tan Delta Test is conducted to assess the insulation quality of transformer oil. It measures the dissipation factor or tan delta, which indicates the power factor of the insulating material. High tan delta values suggest potential issues with the insulation, helping identify and prevent transformer failures.
The recommended value for tan delta or dissipation factor in used transformer oil as per IEC (International Electrotechnical Commission) standards is typically below 0.5%. Higher values may indicate potential issues with the insulation system of the transformer. Regular testing of transformer oil helps assess its condition and detect any deterio...
Просмотров: 4 816

Видео

What are the important factors to be consider for Transformer Maintenance, Explanation in Tamil
Просмотров 1,1 тыс.10 месяцев назад
#trending #electrical #Maintenance #Transformers @Engineering-in-tamil Electrical Interview Questions?
High Voltage Tester, High Voltage Detector, High Voltage Phasing Tester, Electrical Safety in Tamil
Просмотров 1,6 тыс.11 месяцев назад
@Engineering-in-tamil A high voltage Tester, also known as a high voltage detector, The purpose of a high voltage detector or high voltage tester is to determine the presence or absence of live electrical current in high voltage systems or equipment. It is used to ensure the safety of personnel working with or around high voltage power lines, electrical substations, or other high voltage instal...
Current Transformer Secondary Terminals Open Circuit here nothing will happen Why? how? in Tamil
Просмотров 3,2 тыс.11 месяцев назад
@Engineering-in-tamil Answer of the Question Below mentioned points are deeply Explained in video Dual Core Transformer In a dual core current transformer, both the primary and secondary terminals are important for its operation. Both sets of secondary terminals, 1S1 and 1S2 as well as 2S1 and 2S2, are typically connected to relays or other monitoring devices. Leaving any of the secondary termi...
Transformer Turns Ratio Test, Maintenance of transformer, Testing of Transformer in Tamil
Просмотров 9 тыс.11 месяцев назад
Transformer Turns Ratio (TTR) is one of the most common test used to assess the condition of the transformer's windings and core. It is performed as a part of acceptance and maintenance test procedure to determine any problems due to poor design, assembly, handling, overloading, fault conditions or poor maintenance
Vanguard Transformer Turns Ratio Tester, How to use Vanguard TTR Meter in Tamil
Просмотров 84711 месяцев назад
The ATRT-01B S3 is Vanguard micro-processor based, single phase, automatic transformer turns-ratio tester. The ATRT-01B S3, to determine the transformer turns-ratio. The transformer turns-ratio is determined by precisely measuring the voltages across the unloaded transformer windings. The ATRT-01B S3’s measuring circuitry self adjusts before each measurement to ensure turns-ratio accuracy. Two ...
Types Over current Relay, What is Over Current Relay, Instantaneous and IDMT Relays, Types of Relays
Просмотров 2,3 тыс.Год назад
Types Over current Relay, What is Over Current Relay, Instantaneous and IDMT Relays, Types of Relays
What is Transformer Overcurrent Relay, Testing of Overcurrent Relay,Electromechanical relay in Tamil
Просмотров 4,3 тыс.Год назад
What is Transformer Overcurrent Relay, Testing of Overcurrent Relay,Electromechanical relay in Tamil
Electrical Substation, Electrical Switchyard Equipment's of substation and SLD Explanation in Tamil
Просмотров 4,2 тыс.Год назад
Electrical Substation, Electrical Switchyard Equipment's of substation and SLD Explanation in Tamil
What is Faradays Law of Induction? in Tamil, what is the Electricity and how it is Generated?
Просмотров 1,1 тыс.2 года назад
What is Faradays Law of Induction? in Tamil, what is the Electricity and how it is Generated?
Transformer Winding Resistance Test in Tamil, Transformer Testing, Transformer Maintenance in Tamil
Просмотров 28 тыс.2 года назад
Transformer Winding Resistance Test in Tamil, Transformer Testing, Transformer Maintenance in Tamil
VCB Vacuum Circuit Breaker Maintenance, Vacuum Integrity Test, Vacuum chamber/ bottle test in Tamil
Просмотров 17 тыс.2 года назад
VCB Vacuum Circuit Breaker Maintenance, Vacuum Integrity Test, Vacuum chamber/ bottle test in Tamil
CT Secondary Injection, Transformer Mutual induction principle, Faraday's law of induction in Tamil
Просмотров 2,8 тыс.2 года назад
CT Secondary Injection, Transformer Mutual induction principle, Faraday's law of induction in Tamil
What is Knee point Voltage of current transformer| knee point voltage Calculations &Testing in Tamil
Просмотров 14 тыс.2 года назад
What is Knee point Voltage of current transformer| knee point voltage Calculations &Testing in Tamil
What is Fuse? Explanation in Tamil, how it is working| how to select the fuse rating| types of fuses
Просмотров 3,3 тыс.2 года назад
What is Fuse? Explanation in Tamil, how it is working| how to select the fuse rating| types of fuses
Why CT Secondary should not kept open in Tamil | Why CT Secondary is always short circuited?
Просмотров 15 тыс.2 года назад
Why CT Secondary should not kept open in Tamil | Why CT Secondary is always short circuited?
Current Transformer Primary Injection Ratio Test in Tamil l CT Turns ratio test
Просмотров 7 тыс.2 года назад
Current Transformer Primary Injection Ratio Test in Tamil l CT Turns ratio test
What is Inside an Current Transformer in Tamil l CT Dismantling l CT Construction and Working
Просмотров 3,2 тыс.2 года назад
What is Inside an Current Transformer in Tamil l CT Dismantling l CT Construction and Working
Transformer Breather Working in Tamil | Why Breather in Transformer | Silica gel Breather|
Просмотров 3,5 тыс.2 года назад
Transformer Breather Working in Tamil | Why Breather in Transformer | Silica gel Breather|
Transformer Silica Gel Color Changing Process Live Demo Test in Tamil
Просмотров 1,9 тыс.2 года назад
Transformer Silica Gel Color Changing Process Live Demo Test in Tamil
Transformer Gasket in Tamil,Gasket sheet Material & Specification,Bushing Gasket,#EngineeringinTamil
Просмотров 1,2 тыс.2 года назад
Transformer Gasket in Tamil,Gasket sheet Material & Specification,Bushing Gasket,#EngineeringinTamil
Transformer Blast in Tamil l Transformer Accident l Why Transformer blast l #EngineeringinTamil
Просмотров 1,5 тыс.2 года назад
Transformer Blast in Tamil l Transformer Accident l Why Transformer blast l #EngineeringinTamil
Electromagnetic induction disc relay in Tamil, Over current Protection Relay, #EngineeringinTamil
Просмотров 2,2 тыс.2 года назад
Electromagnetic induction disc relay in Tamil, Over current Protection Relay, #EngineeringinTamil
What is? Transformer Tap changer in Tamil|Transformer Maintenance | Off Load & On load Tap changer
Просмотров 21 тыс.3 года назад
What is? Transformer Tap changer in Tamil|Transformer Maintenance | Off Load & On load Tap changer
DGA Test For Transformer in tamil |Dissolved Gas Analysis| Oil Test| Internal Fault Analysis
Просмотров 9 тыс.3 года назад
DGA Test For Transformer in tamil |Dissolved Gas Analysis| Oil Test| Internal Fault Analysis
How to Check Hipot Test for HT Cable in Tamil |High Voltage Test| Pressure Test| Dielectric Test
Просмотров 26 тыс.3 года назад
How to Check Hipot Test for HT Cable in Tamil |High Voltage Test| Pressure Test| Dielectric Test
Electric shock | Back feeding supply | Electrical safety | Electrical maintenance| in Tamil
Просмотров 16 тыс.3 года назад
Electric shock | Back feeding supply | Electrical safety | Electrical maintenance| in Tamil
Transformer turns ratio test in Tamil, Transformer Maintenance in Tamil, Transformer testing inTamil
Просмотров 24 тыс.3 года назад
Transformer turns ratio test in Tamil, Transformer Maintenance in Tamil, Transformer testing inTamil
How to Check CT turns ratio test | Ratio Test |CT Maintenance in Tamil
Просмотров 12 тыс.3 года назад
How to Check CT turns ratio test | Ratio Test |CT Maintenance in Tamil
How to check CT Resistance using multimeter| CT secondary winding Ohms|CT Maintenance | in Tamil
Просмотров 11 тыс.3 года назад
How to check CT Resistance using multimeter| CT secondary winding Ohms|CT Maintenance | in Tamil

Комментарии

  • @KHarshiniMKarthickumar
    @KHarshiniMKarthickumar 6 часов назад

    Hi, could you please clarify whether the acceptable result value is 0.5 or 0.5% (0.005).

  • @paulraj4110
    @paulraj4110 5 дней назад

    Plz make it video in PS CT

  • @paulraj4110
    @paulraj4110 5 дней назад

    Good explanation with CT 😮

  • @aneestec7425
    @aneestec7425 5 дней назад

    Thanks for sharing

  • @ponrajraju2450
    @ponrajraju2450 10 дней назад

    Explain is very well

  • @Suryakumar-1329
    @Suryakumar-1329 12 дней назад

    transformer rating ?

  • @anandsing8013
    @anandsing8013 16 дней назад

    How much voltage need to inject

  • @kss383
    @kss383 29 дней назад

    Winding heat ஐ குறைப்பதற்கு டிரான்ஸ்பார்மர் ஆயில் யூஸ் ஆகிறது

  • @Mohi__
    @Mohi__ Месяц назад

    Super super 🫡

  • @MohanSundaram-fw7nz
    @MohanSundaram-fw7nz Месяц назад

    Explained very well 👏 But how did you get 2mA as a reference leakage current ? You forgot to explain that i guess...

  • @naveensundar2803
    @naveensundar2803 Месяц назад

    Is there polarity for S1 and S2

  • @NovaTech-r2s
    @NovaTech-r2s Месяц назад

    ruclips.net/video/NO0rs-WoXGI/видео.htmlsi=TLZIiZno1uUxraMR

  • @rpt802
    @rpt802 Месяц назад

    Na eee student transformer polarity test podunga sir

  • @amalraj9733
    @amalraj9733 Месяц назад

    Brother... Metering RMU CT & VT testing video pod unga brother

  • @shiekmydeen4107
    @shiekmydeen4107 2 месяца назад

    Super sir

  • @shiekmydeen4107
    @shiekmydeen4107 2 месяца назад

    Relay pathi fulla podunga sir plz

  • @shiekmydeen4107
    @shiekmydeen4107 2 месяца назад

    Good sir

  • @pandiankarthikeyan2977
    @pandiankarthikeyan2977 2 месяца назад

    Aramai..sir....thanks lot

  • @arunkumar-sq8sj
    @arunkumar-sq8sj 2 месяца назад

    Does any one tell, what happen when anyone of the primary winding is open in delta connection??

  • @dhanasekaranmuthusamy4879
    @dhanasekaranmuthusamy4879 2 месяца назад

    Thank you

  • @prabaguts
    @prabaguts 2 месяца назад

    Nice

  • @DhanabalanPonnusamy
    @DhanabalanPonnusamy 2 месяца назад

    Thanks

  • @bruganallasubhan3342
    @bruganallasubhan3342 2 месяца назад

    Bro...LT side winding resistance check pandra pa...Ht side winding epdi irukanamum.. I mean Winding to Earth connect pananuma

  • @bruganallasubhan3342
    @bruganallasubhan3342 2 месяца назад

    How much voktage we should inject to test the LT side winding resstance

  • @dhanasekaranmuthusamy4879
    @dhanasekaranmuthusamy4879 2 месяца назад

    Good

  • @ManikandanGa3
    @ManikandanGa3 2 месяца назад

    Good explanation, thank you

  • @theneshmaharajan2791
    @theneshmaharajan2791 2 месяца назад

    Super explained

  • @rajkumaR-nw1wl
    @rajkumaR-nw1wl 3 месяца назад

    One doubt bro. 200/100mA ct ratio means how to set primary and secondary current in multifunction meter?

  • @rajasekarmanoharan3345
    @rajasekarmanoharan3345 3 месяца назад

    Super explanation

  • @rmurali3355
    @rmurali3355 3 месяца назад

    What is the fuse wire for 5hp motor.... pls

  • @RamaKrishnan-c7z
    @RamaKrishnan-c7z 3 месяца назад

    Good, thanks...❤

  • @kalanithi07
    @kalanithi07 3 месяца назад

    Excellent bro. Plz have my suscription.

  • @murthy_es
    @murthy_es 3 месяца назад

    Brother three phase voltage pannanuma. Kit la irundu epdi three phase connect pannanum

  • @user-us9px5lc7k
    @user-us9px5lc7k 3 месяца назад

    Hi

  • @Mugilan-vh6bv
    @Mugilan-vh6bv 3 месяца назад

    Good information sir, thank you sir

  • @rajeshantony6319
    @rajeshantony6319 3 месяца назад

    Very useful video 🎉

  • @rvsuresh1992
    @rvsuresh1992 3 месяца назад

    Super anna... Romba easy a puriyuthu ....

  • @Fake_life____2002
    @Fake_life____2002 3 месяца назад

    Why use in √2 DC formula

  • @ragulprasanth3576
    @ragulprasanth3576 3 месяца назад

    Sir , reference mA ipdi calculation panrathu

  • @senthilkumar-ss5yq
    @senthilkumar-ss5yq 3 месяца назад

    Sir suppose we found knee point voltage less than Ct name plate details mentioned voltage what action need to take? CT should replace.

  • @MoinKhan-p8j
    @MoinKhan-p8j 3 месяца назад

    CT Ka use earthing wire me kyu use krte hai please reply me

  • @dineshb396
    @dineshb396 3 месяца назад

    ❤ pls upload videos

  • @amalraj9733
    @amalraj9733 3 месяца назад

    Brother! Super.. Excellent

  • @tamilvideos14
    @tamilvideos14 3 месяца назад

    cables connected la irudha edhum prblm ilaiya

  • @v.sanjaykumar6818
    @v.sanjaykumar6818 3 месяца назад

    Transmission and distribution pathi podunga sir

  • @narasappanapple2720
    @narasappanapple2720 3 месяца назад

    ❤ super derivation

  • @kombanffyt8020
    @kombanffyt8020 4 месяца назад

    🎉

  • @lV__TAMILVENDHANV
    @lV__TAMILVENDHANV 4 месяца назад

    Sir nega kuwait erukigaala

  • @imthiaz1995
    @imthiaz1995 4 месяца назад

    Neenga Kuwait la work pandringaloo

  • @ajithkumar.s4383
    @ajithkumar.s4383 4 месяца назад

    Sir srfa testing video podunga🙏