Solar PV & Battery storage Installation In Bournemouth | Step-by-step video |
In this Video today we run you through a breakdown of how we installed 16 Jinko 435w panels with a Fox ESS 6Kw hybrid inverter & 14.5 kWh of battery storage!
Please share, like & subscribe
If your interested in a free quotation please reach out on 01202 923231 or www.letelectrical.co.uk/renewables
⚡️⚡️⚡️Connect with me on Social Media⚡️⚡️⚡️
letelectrical​
let_electri...​
letelectrical.co.uk/​
#electricianinpoole​ #localelectrician​
Let Electrical Services
Electrician in Poole, Electrician in Bournemouth
#dorset #electrician #batterystorage #solarsystem #solarhouse #solar #dorset #poole #bournemouth
Просмотров: 315

Видео

Consumer unit upgrade | 18th Edition SPD fuse board | By an electrician in Poole
Просмотров 1,5 тыс.Год назад
In todays video we are returning for day 2 on this project, we show you a quick run through of us changing over the consumer unit. ⚡️⚡️⚡️Connect with me on Social Media⚡️⚡️⚡️ letelectrical​ let_electri...​ letelectrical.co.uk/​ #electricianinpoole​ #localelectrician​ Let Electrical Services Electrician in Poole, Electrician in Bournemouth
How to Add more Sockets to a ring Circuit | Extending a ring circuit | Electrician in Poole
Просмотров 8 тыс.Год назад
In todays video we extend a ring circuit to add more sockets in an upstairs of a house Don't forget to check out Day 2 ⚡️⚡️⚡️Connect with me on Social Media⚡️⚡️⚡️ letelectrical​ let_electri...​ letelectrical.co.uk/​ #electricianinpoole​ #localelectrician​ Let Electrical Services Electrician in Poole, Electrician in Bournemouth
Energy savings tips by using by upgrading to LED Lighting #ledlighting #outsidelights#moneysavingtip
Просмотров 147Год назад
Energy savings tips by using by upgrading to LED Lighting #ledlighting #outsidelights#moneysavingtip
Poor Existing Electrics | Zappi EV Charger Installed | Difficult Cable route! | Electrician in Poole
Просмотров 594Год назад
Poor Existing Electrics | Zappi EV Charger Installed | Difficult Cable route! | Electrician in Poole
How we carry out an EICR Video | Electrician in Poole | How to carry out an EICR
Просмотров 1,8 тыс.Год назад
How we carry out an EICR Video | Electrician in Poole | How to carry out an EICR
Installation of 2 new consumer units within an outside Office and Garage| By an Electrician in Poole
Просмотров 25 тыс.Год назад
Installation of 2 new consumer units within an outside Office and Garage| By an Electrician in Poole
Installing a Outside socket via conduit by an Electrician in Poole
Просмотров 7 тыс.Год назад
Installing a Outside socket via conduit by an Electrician in Poole
Hello! and Welcome to LET Electrical Services. Please watch this video.
Просмотров 290Год назад
Hello! and Welcome to LET Electrical Services. Please watch this video.
Quote intro video
Просмотров 357Год назад
Quote intro video
Installing a 18th Edition RCBO/SPD Consumer unit | Walk through Video
Просмотров 11 тыс.2 года назад
Installing a 18th Edition RCBO/SPD Consumer unit | Walk through Video
How to test a socket circuit ( Ring Final circuit ) Electrician in Poole
Просмотров 2,7 тыс.2 года назад
How to test a socket circuit ( Ring Final circuit ) Electrician in Poole
How To Fix an electrical fault - Tripping fuse
Просмотров 2632 года назад
How To Fix an electrical fault - Tripping fuse
How To Fit/Replace a Socket By LET Electrical Services
Просмотров 3583 года назад
How To Fit/Replace a Socket By LET Electrical Services
Electrical Installation condition Report Codes Explained
Просмотров 5263 года назад
Electrical Installation condition Report Codes Explained
HOW to Install Electric Underfloor Heating | Electrician in Poole
Просмотров 2533 года назад
HOW to Install Electric Underfloor Heating | Electrician in Poole
DAY in the Life of a jobbing Electrician| Electrician in Poole
Просмотров 3523 года назад
DAY in the Life of a jobbing Electrician| Electrician in Poole
Rewiring Electrical Sockets and lighting Circuits
Просмотров 5273 года назад
Rewiring Electrical Sockets and lighting Circuits
Quinetic Switching Video| LET Electrical Services |
Просмотров 3,6 тыс.3 года назад
Quinetic Switching Video| LET Electrical Services |
LET Electrical Services | 1st Video | Fan Installation #electrician #poole
Просмотров 8663 года назад
LET Electrical Services | 1st Video | Fan Installation #electrician #poole

Комментарии

  • @JMD-yn4btw
    @JMD-yn4btw 5 дней назад

    Nice work! Can you detail the panel setup wattage for the two roofs? You have 6,960 watts total available by the stickers. If you have 4,785 watts on one set and only 2,175 watts on the other set, are they wired the same or different volts/amps? It looks like a very robust system and should provide a lot of power.

  • @EMEL-hr4ut
    @EMEL-hr4ut Месяц назад

    I like Hager and they also have rectangular knockouts. They have a rectangular plastic insert with 20mm knockout so an earthed banjo to earth the armoured should work. Otherwise drill the metal box but hate that as wears me hole saws out ! 🤣

  • @EMEL-hr4ut
    @EMEL-hr4ut Месяц назад

    Good work. I like to stick bonding or tile adhesive around as don't trust my sockets to stay fixed ..fixed ! 😅 i take it the bathroom light was a non connected or loose earth.

  • @EMEL-hr4ut
    @EMEL-hr4ut Месяц назад

    Just the vid I was looking for. IR test at a socket on a ring. Nifty technique.

  • @Dog-whisperer7494
    @Dog-whisperer7494 2 месяца назад

    I would have us hospital conduit saddles , not plumbers copper pipe clip. Also the T box at the socket one screw through the centre would have been plenty . Otherwise it a nice lean in stall 👍

  • @JohnDundee-el2ro
    @JohnDundee-el2ro 3 месяца назад

    What is the black flex or data cable going into the bottom of EV fuseboard and how do you connect it both ends should you not have showed us that

  • @Loake878
    @Loake878 4 месяца назад

    So when you said you’d show us, you just pointed at it.

  • @harveylinney
    @harveylinney 4 месяца назад

    No pig tail on the cable going back in through the wall and sloping downwards 🫣. School boy error or Friday afternoon install?

  • @mrchrome5403
    @mrchrome5403 4 месяца назад

    With no anti thedt protection from dirty thiefs rolling up and charging thier cars too better re think youre design with a lock system!

    • @tommendoza1812
      @tommendoza1812 4 месяца назад

      You can lock the ohme from the app

  • @charliejames678
    @charliejames678 4 месяца назад

    Great video 👏

  • @mozlabmozlab2918
    @mozlabmozlab2918 5 месяцев назад

    Can you add an electric shower circuit on a garage consumer unit

    • @EMEL-hr4ut
      @EMEL-hr4ut Месяц назад

      Electric showers can have their own mini fuse board same as a garage consumer unit where there is no RCD protection on the main fuse board or there is no more room on RCD side (or room at all) to fit an RCD protected breaker. The main power supply is usually cut into with Henly Blocks to supply the shower board and the 10mm power cable feeding the shower run from that. You need at least a 40amp breaker for any decent electric shower and garage consumer units usually only come with a 32amp and 6amp (sockets and lights) so you have to get a new breaker straight off.

  • @train4905
    @train4905 6 месяцев назад

    Exellent

  • @teddycravens9280
    @teddycravens9280 6 месяцев назад

    I smell plastic burning in my bathroom..

  • @bonaminhrasmey42
    @bonaminhrasmey42 6 месяцев назад

    ❤where do you get the power from.

  • @Lee-dp6ji
    @Lee-dp6ji 7 месяцев назад

    Man United in one room

  • @divemasteruk
    @divemasteruk 9 месяцев назад

    Why the speed up, no instructions and most missing, cant see what you are doing

  • @mohammadasadejaz3359
    @mohammadasadejaz3359 9 месяцев назад

    Can i install a a cable outdoor extension to a pluged socket insidde my kitchen

  • @recce45
    @recce45 10 месяцев назад

    In a shed / garden office does the consumer unit have to be a minimum distance from the floor?

  • @Spark101.
    @Spark101. 11 месяцев назад

    Squeeze the croc clips a little…….the reading may come down 👍

  • @Spark101.
    @Spark101. 11 месяцев назад

    L/L: 0.33. N/N: 0.33. E/E: 0.63. The CPC should actually be 0.55 with a tolerance of 0.05 ohms. So the max reading for CPC is 0.60. At 0.63 it’s technically a fail. Slight loose connection somewhere

  • @Spark101.
    @Spark101. 11 месяцев назад

    Its actually within 0.05……..not 0.5, but that might have been a slip of the tongue

  • @Chris-hy6jy
    @Chris-hy6jy 11 месяцев назад

    Personally I'd have routed the tails into the bottom right of the board to keep them clear of the circuit wiring, but good job all the same!

  • @inokinugent57
    @inokinugent57 11 месяцев назад

    That’s a DB upgrade 😂 poor Tennant 18th Edition 😢😢😢😢😢NO RCD Protection

  • @ElectricEssenceLtd
    @ElectricEssenceLtd Год назад

    Great video. 250V should be ok for old wiring.

  • @dennisjorgensen3446
    @dennisjorgensen3446 Год назад

    Good work, who fitted the Isolation Switch?

    • @EMEL-hr4ut
      @EMEL-hr4ut Месяц назад

      That would be the chap in the video. Electricians are now allowed pull main fuses in the Poole area (southern electricity) as long as you get their sealing bands first.

  • @mattunderwood4948
    @mattunderwood4948 Год назад

    Did you install surge protection on this install?

  • @nw5835
    @nw5835 Год назад

    so where is the Consumer unit change and some additional down-lights Video.

  • @nw5835
    @nw5835 Год назад

    You haven't quite grasped the concept of shorts, have you?

  • @ELECTRICLIFE4U
    @ELECTRICLIFE4U Год назад

    👍👍👍👍👍

  • @afghansun
    @afghansun Год назад

    Well done 👍

  • @Matibeos
    @Matibeos Год назад

    Hi mate, great video for trainees like myself. Thanks for taking the effort to film, edit & upload. Very newbie question here, but when you buy the 3core cable does it matter what the core colours are? Obviously you use brown for live but why is it black for CPC & grey for neutral? Can’t you ask for blue, brown & earth? 3phase has black grey brown and it’s confusing me! Cheers 👍🏻

  • @chris..L-d4y
    @chris..L-d4y Год назад

    Good job

  • @keithjackett9895
    @keithjackett9895 Год назад

    Can you explain to me why there are 3 red 2.5 wires in 2 of the 32 Amp Rings? Are 2 of them for a Ring and the 3rd a fused spur maybe??? Answers Below Please .

    • @letelectricalservices5143
      @letelectricalservices5143 Год назад

      Correct, 3rd is a spur

    • @Baggiolyful
      @Baggiolyful 6 месяцев назад

      When I did my 18th edition refresher course my teacher pointed out that you are allowed to spur off a ring Mcb with one double socket and there it was in the regs book I didn’t know. This was useful recently when I needed a double socket in a cupboard for a cctv rack but the board was full.

    • @keithjackett9895
      @keithjackett9895 6 месяцев назад

      Yes you are correct, i was thinking of an optimal design where one wouldn't require an add-on spur. thankyou for your responce Sir.@@Baggiolyful

    • @kennyla4060
      @kennyla4060 4 месяца назад

      Your aloud to fuse spur directly from the mcb

    • @keithjackett9895
      @keithjackett9895 4 месяца назад

      What about bridging a RCBO cos you can only get 2 x 2.5mm cable in each Live & Neutral terminals? Are Wago blocks aloud??

  • @Luberg330
    @Luberg330 Год назад

    Russia 🇷🇺

  • @12000gp
    @12000gp Год назад

    Who pulled that main fuse out?

  • @martinburgess2322
    @martinburgess2322 Год назад

    Nice little job 👍👊

  • @JIBS.
    @JIBS. Год назад

    Nice video. Are you keeping the ring intact due to carpets etc being up and would you in another environment if the carpets were all down & the room packed just fuse spur the ring and your sockets that way.

    • @EMEL-hr4ut
      @EMEL-hr4ut Месяц назад

      If carpets down they got to come up ! Electricians love moving furniture and pulling back carpets ! The job would just be too easy otherwise and only half the fun ! 😅

  • @letelectricalservices5143
    @letelectricalservices5143 Год назад

    If you enjoyed this video don't forget to Like and Sub!

  • @tonyleo7529
    @tonyleo7529 Год назад

    Does the equipotential bonding on the gas have to be before the tee on the gas outlet pipe? I know nothing about electrical requirements. Not sure how much of a difference it would make on this installation? As a gas engineer, just wondering how much of a difference it would make here? Nice tidy work on the consumer unit.

    • @letelectricalservices5143
      @letelectricalservices5143 Год назад

      Morning, The regulation like the gas bonding to be installed within 600mm from memory as stated here "The main equipotential bonding conductor connection to any gas or other service should be made as near as practicable (preferably within 600mm) to the point of entry to the premises." Hope this helps

  • @terrymayes601
    @terrymayes601 Год назад

    Did you have to change the wall box to deeper depth for switch.thanks

  • @Montalbano_
    @Montalbano_ Год назад

    What size armoured cable did you use?

    • @letelectricalservices5143
      @letelectricalservices5143 Год назад

      6mm 3core SWA With a 32amp MCB

    • @ali3ndnb
      @ali3ndnb Год назад

      @@letelectricalservices5143 Do you need 3 core? Doesn’t the armour act as your bonding?

    • @persona250
      @persona250 5 месяцев назад

      @@ali3ndnbit does . Try getting 2 core swa from wholesalers.

  • @michaelmason5174
    @michaelmason5174 Год назад

    No gasget or sealer on angle box ?

    • @letelectricalservices5143
      @letelectricalservices5143 Год назад

      Hi firstly thank you for your comment. Installation was installed within a porched area, used an outside socket for damage protection as he was using it as a workshop so no need for a gasket. We used sealers around the tube joint as shown in the video. Thanks Lewis

  • @electricalsolutionse4ltd700
    @electricalsolutionse4ltd700 Год назад

    Good job brother, love those lewden boards.👍👍👍👍👍👍👍

  • @electricalsolutionse4ltd700
    @electricalsolutionse4ltd700 Год назад

    Good job brother great vid, I’ll catch up and follow your content. Hopefully I’ll get some content if my own out soon.👍👍👍👍👍👍

    • @letelectricalservices5143
      @letelectricalservices5143 Год назад

      Thank you! much appreciated. Definitely get some out, RUclips took bit of a back foot for me due to work load!

  • @zippymo672
    @zippymo672 Год назад

    My mentor said if it is old wiring like you have in that property, then you shouldn't really need to test at 500v. 240v should be enough. Each to their own I guess.

  • @allanjseven
    @allanjseven Год назад

    Hi As there is no rcd protected circuits or spd in place. What code would this be now with the new amendment in force? Many thanks

    • @letelectricalservices5143
      @letelectricalservices5143 Год назад

      RCD C2 depending on which part i.e. sockets that can be used outdoors etc.

    • @allanjseven
      @allanjseven Год назад

      @@letelectricalservices5143 thanks what about no spd present?

  • @ianmiller3182
    @ianmiller3182 Год назад

    Nice run through. Was the water supply a metal service ? The gas bond probably should have been before any branches.

  • @zippymo672
    @zippymo672 Год назад

    Quality install. I'm still a learner in the trade so I find these type of videos very helpful.

  • @ImranKhan-cf8gs
    @ImranKhan-cf8gs Год назад

    Why earth twice this is 3 core armoured

    • @letelectricalservices5143
      @letelectricalservices5143 Год назад

      Hi, we earth the armoured aswell to ensure its safe if it was to get hit by a spade or alike

    • @persona250
      @persona250 5 месяцев назад

      The armour is an exposed conductive part and has to be connected to the earthing system.

  • @sergiofernandez3725
    @sergiofernandez3725 Год назад

    Good tip.