CATERPILLAR/ PERKINS C4.4 EGR (NRS) temporary fix for derate 2791-7code
code 2791-7 EGR Valve Control : Not Responding Properly.
this is a just a temporary fix until your able to replace the EGR valve, the code should clear on it's own. make sure there is nothing loose inside of the manifold before installing.
Просмотров: 1 173

Видео

TROY BUILT HORSE ROTOTILLER TILLER tine worm gear replacement
Просмотров 1,4 тыс.9 месяцев назад
note: this is a 1994 model. it's fairly easy to repair, if you don't change the tapper roller bearings, don't worry about the end play, just put the same shims back in. remember to clean the hell out of it, any metal shavings have to be cleaned out of it. you will need to buy some long snap ring pliers they are about $10 on amazon 1901976 Worm Gear 1 92104035 Oil Seal 2 92104030 Oil Seal 1 GW11...
After SHTF power 2, basics of charging a car battery, charge controllers
Просмотров 2879 месяцев назад
#shtf
Dear, Generac do you hate techs?
Просмотров 699 месяцев назад
i forgot to add, Generac put there own payload into the john deer's ECM, so it will not derate if the DPF is plugged. (i know, i hate emissions too)
fuel filters working overtime. contaminated diesel.
Просмотров 269 месяцев назад
fuel filters working overtime. contaminated diesel.
After SHTF power 1, you NEED a meter, basics of using a meter
Просмотров 229 месяцев назад
#shtf #prepper
1HP Jet Pump Rebuild, Pump is Whining
Просмотров 231Год назад
1HP Jet Pump Rebuild, Pump is Whining
tour of a (small) landfill gas powered power plant
Просмотров 287Год назад
when i said keeping a vacuum on the system, i meant on the wells, to keep down surface emissions from the landfill
project thermo king 15 kw generator part three, engine teardown and rebuild
Просмотров 1 тыс.2 года назад
project thermo king 15 kw generator part three, engine teardown and rebuild
trashed Honda ES6500
Просмотров 1,4 тыс.2 года назад
trashed Honda ES6500
project thermo king 15 kw generator (kind of a dumpster fire) part two. strike two..
Просмотров 2792 года назад
project thermo king 15 kw generator (kind of a dumpster fire) part two. strike two..
resealing oil pump/oil pan 2nd gen MDX acura
Просмотров 22 тыс.2 года назад
sorry about not showing it running, i forgot to. this applies to most j series Honda
the new to me project thermo king 15 kw generator (kind of a dumpster fire) part one
Просмотров 1,5 тыс.2 года назад
overview the generator and finding out that it has a bad hole Cummins 15 kw alternator and 2.2L NA Isuzu diesel
one of those failure to launch days
Просмотров 422 года назад
one of those failure to launch days
lighting off a 3MW(3000KW) KOHLER 175 series
Просмотров 1522 года назад
lighting off a 3MW(3000KW) KOHLER 175 series
Kohler generator showing "phantom" faults,
Просмотров 2,1 тыс.3 года назад
Kohler generator showing "phantom" faults,
Troubleshooting Well Pump Pressure Switch
Просмотров 41 тыс.3 года назад
Troubleshooting Well Pump Pressure Switch
Chinese SG700MD micro inverter, cooling
Просмотров 4 тыс.3 года назад
Chinese SG700MD micro inverter, cooling
kohler 350kw random under voltage alarm
Просмотров 1,3 тыс.3 года назад
kohler 350kw random under voltage alarm
THE BROKE ASS HOMEOWNER: the pipe puller project.. part 4, the anti climatic ending
Просмотров 2304 года назад
THE BROKE ASS HOMEOWNER: the pipe puller project.. part 4, the anti climatic ending
Advice for the first time firearm buyers, in California
Просмотров 1574 года назад
Advice for the first time firearm buyers, in California
another generac trouble call..
Просмотров 1964 года назад
another generac trouble call..
THE BROKE ASS HOMEOWNER: the pipe puller project.. part 3 just breaking everything
Просмотров 3544 года назад
THE BROKE ASS HOMEOWNER: the pipe puller project.. part 3 just breaking everything
THE BROKE ASS HOMEOWNER: the pipe puller project.. part deux (2)
Просмотров 1084 года назад
THE BROKE ASS HOMEOWNER: the pipe puller project.. part deux (2)
THE BROKE ASS HOMEOWNER: the pipe puller project.. part 1
Просмотров 2,6 тыс.4 года назад
THE BROKE ASS HOMEOWNER: the pipe puller project.. part 1
THE BROKE ASS HOMEOWNER: A small plow job
Просмотров 724 года назад
THE BROKE ASS HOMEOWNER: A small plow job
ROTATE YOUR BRAKE PADS!!!
Просмотров 4614 года назад
ROTATE YOUR BRAKE PADS!!!
Quick Random Generators #23 shipping damage strikes again!!
Просмотров 904 года назад
Quick Random Generators #23 shipping damage strikes again!!
poulan micro fixing the chain adjuster and BSing
Просмотров 3,3 тыс.4 года назад
poulan micro fixing the chain adjuster and BSing
17mm stubby wrench fixed
Просмотров 764 года назад
17mm stubby wrench fixed

Комментарии

  • @Jeff-jr3sg
    @Jeff-jr3sg День назад

    Thank you so much man. Your video just saved us at work after the hurricane that hit.

  • @IRONMANMETALBILLDANKANIS
    @IRONMANMETALBILLDANKANIS 6 дней назад

    Best video about this winch. Thanks. Reposition the camera. Your arm is in the way. A lot of the shots

  • @TheAurorastorage
    @TheAurorastorage 14 дней назад

    Nice vid on setting the exercises. Thanks. Would you happen to know how to program some dry contacts inside the controller panel to those green screw down connectors? I'm specifically looking to be able to have a set of dry contacts to tell me when there is no commercial power and one to tell me that the transfer switch is in the active mode to the generator. Thanks.

  • @davidschlabach8817
    @davidschlabach8817 17 дней назад

    God fucking damnit i just replaced my timing belt and crank seal thinking that was what was leaking, inside of timing cover still full of oil after this has got to be it

  • @larryehlert7506
    @larryehlert7506 19 дней назад

    What is the best solar panel set up for these??

  • @Camperman1951
    @Camperman1951 21 день назад

    Umm

  • @chiefordnance
    @chiefordnance 24 дня назад

    I HATE STANDADYNE injection pumps I replace so many while in the Army, plus the HMWWVS had them garbage.

  • @evanjbentley9719
    @evanjbentley9719 Месяц назад

    thank you for posting saved me 400 dollars you the man

  • @dannyc7839
    @dannyc7839 Месяц назад

    My freespool knob shaft broke. Is there any ways to take that out?

  • @petejansen7220
    @petejansen7220 Месяц назад

    Great video BUT a your hand is in the way to see which terminals you are touching with your metre when testing the switch

  • @jesseleanos3997
    @jesseleanos3997 Месяц назад

    And uuuuuu and uuuuuuuuuu and uuuuuu you should really practice your script. It made it impossible to watch your video and uuuuu and uuuu

  • @jamshermon
    @jamshermon Месяц назад

    Brother I have one generator showing voltage fluctuation when I aplay load , please provide better solution Spectrum Detroit diesel(model:230 DSE)300 KVA generator

  • @brianclugston.hypnotist.B2
    @brianclugston.hypnotist.B2 Месяц назад

    pronounced...generjunk....lol....did it have an hpanel in her or an older controller?

  • @brianclugston.hypnotist.B2
    @brianclugston.hypnotist.B2 Месяц назад

    I love the video,,,minus the ats buzzz, lol. As an update, flightsystems has made a 1500 replacement that covers the 1000 1200 and 1500. They also do repairs on the original 1500. Also they repair the old 340 controllers as well. this is as june 2024. I do have a question though....do you remove the original transformer array as well?

  • @Knuckle_Draggr
    @Knuckle_Draggr Месяц назад

    I can't get over the heavy mouth breathing

  • @SkaBob
    @SkaBob 2 месяца назад

    I have the same kind, SG500MD, and if you pull the board out you will probably find the MOSFETS have the same thermal interface tape with the blue covering still on them. Likely preventing effective heat transfer to the case. It wasn't too hard to pull it apart and get the board half way out to pull the liner off the tape. Maybe a 20 minute job, hoping it fixes the throttling on hot days.

  • @blackout7615
    @blackout7615 2 месяца назад

    My favorite part of this is when you said "i was born a f-up, i know how to fix my problems"

  • @jmhall918
    @jmhall918 2 месяца назад

    “From here to here” ::covers “here” with his hand::

  • @hrdman2luv
    @hrdman2luv 2 месяца назад

    If it's starting and stopping, change your breaker. It's probably rusted all to hell in there, from the tape that's on it. (trapping moisture) inside it. Humidity will rust them out pretty quick.

  • @nspro931
    @nspro931 2 месяца назад

    I was just reading the manual for these and it says you can't replace the SCV and must replace the whole pump. Where did you get the SCV to replace? Did they change their stance or something?

  • @AnthonyGriz
    @AnthonyGriz 3 месяца назад

    Big thank you for sharing this - I literally just had the exact same problem, a nice easy solution!

  • @bluejene2146
    @bluejene2146 3 месяца назад

    Cool video thanks for posting you remind me of a mechanic in the last shopp i worked in

  • @nerdoutreachprogram5358
    @nerdoutreachprogram5358 3 месяца назад

    This is the only video in all internet of someone taking apart this specific vacuum. Mine stopped working and it’s got to be the switch or the motor.

  • @nerdoutreachprogram5358
    @nerdoutreachprogram5358 3 месяца назад

    How did you get the foot power switch off?

  • @kingservicesoftexas2564
    @kingservicesoftexas2564 3 месяца назад

    I used a paper clip. Worked just fine

  • @thomasrice2888
    @thomasrice2888 4 месяца назад

    The manual recommends installing seals last to prevent damage. Otherwise great video.

  • @solucionestecnologicasvzla
    @solucionestecnologicasvzla 4 месяца назад

    I need the software , can you help me..

  • @brettsummer5070
    @brettsummer5070 4 месяца назад

    One of my units do that if the low coolant temp comes on. Lights up like 6 different alarms.

  • @leusmaximusx
    @leusmaximusx 4 месяца назад

    allowable ampacity (AA) is permitted to be the 90deg when temperature correction factor necessitates application #2 THHN will have AA to be 130A * (say 0.96) Temp Correction Factor for hotter ambient = 124.8A to be connected to a 75deg terminal >> than by using THW at 115A , even though when no correction factor both THW & THHN have AA of conductor ampacity (CA) of 115A to a 75 deg terminal ; this is the advantage of using THHN in hot environments which the NEC permits .

  • @deadsalmondead
    @deadsalmondead 4 месяца назад

    Pro tip I just discovered if you submit a warranty claim in the first two months for defective item they send you a refund check and just tell you to dispose of the defective item. Free pump, boom.

  • @claudioguerrero6192
    @claudioguerrero6192 5 месяцев назад

    My Kohler generator turns off after 2 minutes and sends the auxiliary failure alarm, what would be the reason?

    • @brettsummer5070
      @brettsummer5070 4 месяца назад

      My money is on the low coolant sensor. Top of coolant (and I mean fill it until it’s touching the cap) if that doesn’t work, try bypassing the sensor it might have failed

  • @cbigham
    @cbigham 5 месяцев назад

    I think your looking at the Exeter rotor and stator not the pmg, pmg would be behind that rotor.

  • @poxbottle7791
    @poxbottle7791 5 месяцев назад

    Ehh umm ahh mmm ammm ehh. your boring ramblings I could only take for 6 minutes.

  • @nelchan2421
    @nelchan2421 5 месяцев назад

    Please be gentle and be grateful. Not everyone can afford a new Ryobi or any brand of power tools.

  • @fungiuse
    @fungiuse 5 месяцев назад

    There is no CURE or FIX for this type of cleaner!!! The first trouble, simply throw away and not waste time trying to fix it !!! You pay for what you get... It's a JUNK vac cleaner ........ Next time Buy a DYSON !!

  • @ding9633
    @ding9633 6 месяцев назад

    Why did the last seal only last 20k?

  • @user-se8qy2xk8g
    @user-se8qy2xk8g 6 месяцев назад

    Do you know if these generator ends are able to be wired for 230 volt?

  • @Abbadon2001
    @Abbadon2001 6 месяцев назад

    This looks like the EGR off a C6.6 or C7.2, are you sure its from a C4.4?

  • @jaygreen4526
    @jaygreen4526 6 месяцев назад

    go grab another beer and call it a day my buddy.

  • @AllenNix-iz6ev
    @AllenNix-iz6ev 6 месяцев назад

    They say you should run for 30 hours for break in time without a load ... And they are know to run for 20.000 thousand hours before tear down ....

    • @chainsawsandgenerators9952
      @chainsawsandgenerators9952 6 месяцев назад

      i just looked at a Ryobi with 2500 hours and it was done, completely worn out. now, if you take care of it, change the oil frequently and run it at 50% or less then yes, i can see getting over 20k hours out of it. i seen an Isuzu generator with 100k hours, and the head has never been off.

  • @FrankBennett-oj8ph
    @FrankBennett-oj8ph 6 месяцев назад

    Are these the steps I need for delaying the start times? When I do a load test, I need the AC units to completely stop spinning before the Transfer switch swaps to generator power. The office equipment is on battery, so I have time. I want it to delay 4 minutes before the load is transfered.

  • @robbypro3370
    @robbypro3370 6 месяцев назад

    This generator won't even run my small microwave.for 10 seconds. Maybe the power convertor was on charging the battery at the same time?

    • @chainsawsandgenerators9952
      @chainsawsandgenerators9952 6 месяцев назад

      possibility, a small microwave only draws about 800 watts. in eco mode, dose it sound like its going full speed before you connect the microwave in? if it is, then that's your problem

    • @robbypro3370
      @robbypro3370 6 месяцев назад

      @chainsawsandgenerators9952 No, it went full speed on the microwave start up and 10 seconds of running, the microwave shut down with a lo pwr on display. The generator stayed running but wasn't supplying enough power to keep up. Shore power works fine.

  • @avidal85
    @avidal85 7 месяцев назад

    Great video! We have been dealing with a problem in a CTG 1200A ATS with the MX150 controller. The thing is, we set up the everything and genset run every test fine from the controller including load test, no load start, etc. The thing is that when we shut down the utility to test like in a real life situation: 1) I takes 1 exact minute to close the start relay, even when the start delay is set to the minimum time. 2) When it finally starts, as soon as the generator runs, the start relay opens and turns the genset off, and closes and open again and again until when stop it manually. 3) I’m not very familiar with the MX150, but the controller screen is supposed to turn off when the utility goes out? Any input on this will be appreciated!! Thanks 🙏🏻

    • @chainsawsandgenerators9952
      @chainsawsandgenerators9952 6 месяцев назад

      have you tried setting the engine start for something like 10 seconds? you may have lost the coin cell battery, power down the ATS, and remove the back cover form the controller and you'll see it. lastly and most likely the logic is corrupt, if it is send it to these guy's www.flightsystems.com/ i use them a lot, i think the last one we did cost about $550

  • @deadsalmondead
    @deadsalmondead 7 месяцев назад

    Let’s say I wanted to lower the output rate to use for filling gopher tunnels with mud without risking blowing mud all over the lawn by accident. Could I cut the impeller blades down smaller and that would do it?

    • @chainsawsandgenerators9952
      @chainsawsandgenerators9952 6 месяцев назад

      i'd try using a celling fan speed controller something that's raided for something like 1000 watts

    • @deadsalmondead
      @deadsalmondead 6 месяцев назад

      @@chainsawsandgenerators9952 ok cool.

    • @deadsalmondead
      @deadsalmondead 6 месяцев назад

      @@chainsawsandgenerators9952 ok cool. So I found KBWC-210K it’s a speed controller with a little over 1000watt rating. So you suggest splitting open the cable for the float switch to wire the speed controller instead of the float switch? Your help is much appreciated 👍👍👍

    • @deadsalmondead
      @deadsalmondead 6 месяцев назад

      @@chainsawsandgenerators9952 ok so my buddy said try a rheostat. Basically it restricts the power to the pump or something. It’s description is “Newest For Router Fan Variable Speed Controller Electric Motor Rheostat AC 120V” and it has the output plug where the pump would plug in, and a power cable to plug into the wall outlet. So bam ! I guess I am going to try that.

  • @ruivalentect2ggx918
    @ruivalentect2ggx918 7 месяцев назад

    Hello my friend Can you tell me the app you use to connect wifi ?

    • @chainsawsandgenerators9952
      @chainsawsandgenerators9952 7 месяцев назад

      i don't use the app.

    • @SkaBob
      @SkaBob 2 месяца назад

      I have one like that, it needs an external wireless adapter to connect to a program on a computer. It was called databox24g, they are around $40 on direct from China websites. Then it took a while to find the netms software, the download link didn't work anymore.

    • @SkaBob
      @SkaBob 2 месяца назад

      I have the same type of inverter, it needs a seperate wireless data collector plugged into a computer. It's called something like databox24G and for sale on direct from China sites think I paid around around $40 for it. It records the data on a computer you can view it on the netms program, but you can't access it online. Plus side is it will work forever even if the app gets shut down or they go out of business. Some of the newer ones do have wifi, you need to check your paper and see if it says NETMS and databox for monitoring.

  • @vicentesantiago2142
    @vicentesantiago2142 7 месяцев назад

    How to connect tranferswitch to this controller?

  • @stevenarron1545
    @stevenarron1545 8 месяцев назад

    I have similar problem but don't have parts available... please can you help.

  • @Arjun-lt3nx
    @Arjun-lt3nx 9 месяцев назад

    *promosm*

  • @edricoddot
    @edricoddot 9 месяцев назад

    Hook battery up first, duh

  • @edricoddot
    @edricoddot 9 месяцев назад

    I think someone with better knowledge would do a better job explaining this job. Good riddens