![YAPS ELECTRO](/img/default-banner.jpg)
- Видео 12
- Просмотров 19 818
YAPS ELECTRO
Добавлен 7 окт 2019
Z zero with tool touch off probe on ULTIMATIK 48M
In this video I show how to Z zero with tool touch off probe on ULTIMATIK 48M
Просмотров: 49
Видео
Z zero common way on ULTIMATIK 48M
Просмотров 36Год назад
In this video I show how to Z zero common way.
Tool length measuring for ULTIMATIK 48M
Просмотров 21Год назад
In this video I show how to measure the tool length.
ASDA-B2 Factory Reset
Просмотров 17 тыс.3 года назад
How to reset parameters of ASDA-B2 Delta AC-Servo Drive, back to Factory default.
ULTIMATIK 48M cutting melamine doors
Просмотров 8734 года назад
Cutting melamine doors including holes for hinges with ULTIMATIK 48M CNC router.
Engraving letters with CNC Router "ULTIMATIK MINI"
Просмотров 5014 года назад
Engraving letters with CNC Router "ULTIMATIK MINI". Engraving letters on double layered plastic.
ULTIMATIK 48M CNC router 2
Просмотров 2104 года назад
Ultimatik 48M is designed for small Kitchen Cabinet Shops, very compact CNC Router. Runs on single phase 220~240 Volt or 208~240 Volt three phase.
ULTIMATIK 48M CNC router 1
Просмотров 7684 года назад
Ultimatik 48M is designed for small Kitchen Cabinet Shops, very compact CNC Router. Runs on single phase 220~240 Volt or 208~240 Volt three phase.
How to use the ULTIMATIK MINI CNC router in manual mode
Просмотров 1274 года назад
How to use the ULTIMATIK MINI cnc router in manual mode with DDCSV 2.1 controller.
How to save the toolpads for the ULTIMATIK MINI cnc router using ArtCAM
Просмотров 614 года назад
How to save the toolpads for the ULTIMATIK MINI cnc router using ArtCAM.
How to load program and make part zero on ULTIMATIK MINI cnc router
Просмотров 1174 года назад
How to load program and make part zero on ULTIMATIK MINI cnc router with DDCSV 2.1 controller.
How to Home the ULTIMATIK MINI cnc router
Просмотров 3054 года назад
How to Home the ULTIMATIK MINI cnc router with DDCSV 2.1 controller
Hello, how is the measurement calibration done on this device? For example, when I say Y go 10 MM, I actually want it to go 100 mm.
Hi Ibrahim, sorry for late reply. If you actually want to go Y 100mm then you have to enter 100mm not 10mm.
There is a slightly used one (2022) for sale in my town. I am thinking about purchasing it to make some doors, head boards, and cabinets
Nice machine George!
AL025?
Please send position mode wiring details
Good 👍
Do you Know Drive Working Speed setings
Please solution Al009
Do you know the solution for al022?
Sorry for late reply, AL022 Main circuit power lack phase: Check if RST power cable is loose or does not connect to the power. This alarm occurs when no power connects to single phase servo drive.
Please Contact CN1 Wiring Image
P2 - 08 = 10
please Do you know the solution for alarm 009?
Sorry for late reply, AL009: Excessive deviation of Position Command Causes Checking Method Corrective Actions Parameter P2-35 is set too small Check the setting value of parameter P2-35 (The warning condition of excessive position deviation). Increase the setting value of P2-35 (The warning condition of excessive position deviation). The setting of the gain value is too small. Check if the setting value is appropriate. Correctly adjust the gain value. The torque limit is too low. Check the torque limit value. Correctly adjust the torque limit value. Excessive external load Check the external load. Reduce the external load or evaluate the motor capacity again.
Do you know the solution for alarm 009?
Sorry for late reply, AL009: Excessive deviation of Position Command Causes Checking Method Corrective Actions Parameter P2-35 is set too small Check the setting value of parameter P2-35 (The warning condition of excessive position deviation). Increase the setting value of P2-35 (The warning condition of excessive position deviation). The setting of the gain value is too small. Check if the setting value is appropriate. Correctly adjust the gain value. The torque limit is too low. Check the torque limit value. Correctly adjust the torque limit value. Excessive external load Check the external load. Reduce the external load or evaluate the motor capacity again.
Please AL.009 Discuss and Connecting Wiring Image
Al.o11 ka alarms kese remove hoga
Encoder cable check