- Видео 74
- Просмотров 207 833
TroubleshootTech
Индия
Добавлен 3 дек 2021
Welcome To TroubleshootTech.
In this Channel We Show
Electrical and Electronics Projects
Electronics Components
Discription and How to use them
Electrical And Electronics General Knowledge
Industrial Automation & General Purpose Electronics Problems Solutions Like As
PLC Programming, Commissioning, Installing, Problem Troubleshooting And Repairing Related Videos
VFD Parameters Setting, Faults Solutions, Installation Commissioning & Repairing Related Videos
VFD Installation For Solar Panel
HMI Programming, Commissioning, Installing, Problem Troubleshooting And Repairing Related Videos
Servo Drive Programming, Commissioning, Installing, Problem Troubleshooting And Repairing Related Videos
Soft Starter Parameters Setting Faults Solutions Installation & Commissioning And Repairing Related Videos
Programming And Fault Troubleshooting
Electrical Panel Wiring
Electronic Components Testing
For Inquiry You Can Contact Us - spectrum0173@gmail.com
9682877982 WhatsApp
In this Channel We Show
Electrical and Electronics Projects
Electronics Components
Discription and How to use them
Electrical And Electronics General Knowledge
Industrial Automation & General Purpose Electronics Problems Solutions Like As
PLC Programming, Commissioning, Installing, Problem Troubleshooting And Repairing Related Videos
VFD Parameters Setting, Faults Solutions, Installation Commissioning & Repairing Related Videos
VFD Installation For Solar Panel
HMI Programming, Commissioning, Installing, Problem Troubleshooting And Repairing Related Videos
Servo Drive Programming, Commissioning, Installing, Problem Troubleshooting And Repairing Related Videos
Soft Starter Parameters Setting Faults Solutions Installation & Commissioning And Repairing Related Videos
Programming And Fault Troubleshooting
Electrical Panel Wiring
Electronic Components Testing
For Inquiry You Can Contact Us - spectrum0173@gmail.com
9682877982 WhatsApp
AC Drive Analog Input 2-8V to 0-50Hz AC Drive VFD All Setting Parameter for Analog Input #control
Is video mein VFD ya AC Drive ya Inverter ke Analog Input AVI ke baare mei Sabhi Type ki speed control kaise karna kis parameter mei kya Value set Karna hai Sab Kuch bataya gaya hai...
Agar is Video se related ya Other VFD ya AC drive ya Inverter ke baare mei Koi bhi Question ho aap Comment mei Punch sakte ho...
Is video mei maine Bataya Hai Analog Input 0-10V ko Kaise Different voltage par set kar sakte hain... Or Analog Frequency Reference speed ko bhi Kaise set karna Hai Or Kis Parameter mei kya Set karna hai .... Wiring Ka Animation Or Hard Wiring se sab Bataya gaya hai....
Yaha mai 5K ka Potentiometer use kar raha hu... Jise AVI input, ACM or +10V par Connect Kiya Hua Hai ....jisko ma...
Agar is Video se related ya Other VFD ya AC drive ya Inverter ke baare mei Koi bhi Question ho aap Comment mei Punch sakte ho...
Is video mei maine Bataya Hai Analog Input 0-10V ko Kaise Different voltage par set kar sakte hain... Or Analog Frequency Reference speed ko bhi Kaise set karna Hai Or Kis Parameter mei kya Set karna hai .... Wiring Ka Animation Or Hard Wiring se sab Bataya gaya hai....
Yaha mai 5K ka Potentiometer use kar raha hu... Jise AVI input, ACM or +10V par Connect Kiya Hua Hai ....jisko ma...
Просмотров: 30
Видео
How To Use Counter In Delta VFD Complete Detail With Wiring and Parameter Start with Factory Reset
Просмотров 677 часов назад
How to use Delta VFD as A Counter.... Delta VFD EL has Inbuilt Counter Function... In this Video I'm Showing Delta VFD Complete Wiring for Counter Function with PNP And NPN Mode. I'm using Digital Input MI3 for Counting Pulse and Digital Input MI4 use for Counter Reset. I'm using Two types or Function of Counter ... In which Counter Set at A set value then Relay only switch and in other relay w...
PNP or NPN Connection ki Complete Detail With Wiring. Delta Drive PNP NPN Mode select by Dip Switch
Просмотров 12221 час назад
Is video mein delta Drive ko PNP for NPN mod per chalaya gaya hai Aur PNP or NPN ke bare mein samjhaya bhi gaya hai PNP aur NPN board drive mein kis tarike se kam karta hai aur uski wiring Kaise ki jaati Hai Is video mein main jo model use kar raha hun vah Delta drive ka 3 Phase ka model Hai 1 HP mein Agar aapko Delta drive ke bare mein kuchh Bhi baat samajh mein nahin aati hai ya video mein jo...
Delta VFD EL Preset Speed Multi Speed Multi Frequency Fixed different Frequencies Fix Frequency
Просмотров 1542 месяца назад
Delta VFD EL programming for :- Crane Application Elevator Application Multi speed application Multi-Speed Multi Frequency Preset Speed Preset frequency Diffrent Fix Frequency If we want to run VFD at some Fixed Frequency use these parameters Delta Multi Speed VFD setting DELTA lift application Delta Elevator Application ELEVATOR Brake Operation using Relay Delta VFD Relay use in Lift or Crane ...
Delta Servo Drive ASDA A2 Run Using external encoder... for Cutting machine Application...
Просмотров 1725 месяцев назад
in this cutting machine Project I'm using an delta A2 servo 5000PPR Encoder Proface HMI 4402 and TM200 Schneider PLC contact me for Project Discussion 9682877982
Estun Pronet E 15 A Servo Drive JOG Mode Parameter setting
Просмотров 8338 месяцев назад
Estun Servo Drive JOG Mode Testing Step by Step Parameter setting
Delta VFD EL Keypad Lock Unlock या Parameter lock Unlock setting.. Factory Reset Error..how to solve
Просмотров 4,7 тыс.9 месяцев назад
Delta VFD keypad Lock Unlock setting इसी से ही parameter lock Unlock setting bhi hoti hai... parameter lock हैं या keypad lock है तब आप factory reset या factory Default या all Parameter reset karenge तब आपको Err... Show होगा... इसको अनलॉक करने के लिए Parameter number 00.02 में 0 सेट करना है और enter कर देना है.. इससे parameters unlock हो जायेंगे... और जब आप factory Reset करेंगे तो फैक्ट्री रिसे...
Delta VFD EL में पॉट से Frequency या स्पीड control कैसे करे... इस वीडियो में parameter setting देखे
Просмотров 3569 месяцев назад
Delta EL VFD Keypad Potentiometer Speed Control parameter setting पोटेंशियोमीटर से इस ड्राइव में स्पीड कंट्रोल कैसे करते हैं वह हम देखेंगे इस वीडियो में मैंने बताया है अगर हमें ड्राइव को लोकल मोड में पोटेंशियोमीटर से कंट्रोल करना है वह हम कैसे करेंगे लोकल मोड का मतलब है ड्राइव को कीपैड से कंट्रोल करना और रिमोट का मतलब है ड्राइव को टर्मिनल वायरिंग से या कंट्रोल वायरिंग से कंट्रोल करना मैं इस वीड...
Delta VFD EL or Delta EL VFD or Delta EL Drive Factory Default or Reset All Parameter or Factory
Просмотров 1,3 тыс.9 месяцев назад
delta VFD Ya Delta Drive EL series ko Factory Reset kaise karna hai wo hum is video mei dekhenge .... #automation #electronic #delta #vfd
Inovance servo drive SV630A SV630B SV630P SV660P में factory Reset या factory Default कैसे करें
Просмотров 1,1 тыс.9 месяцев назад
Inovance Servo Drive में किस पैरामीटर में factory reset या सभी पैरामीटर्स को कैसे रिसेट करना है... देखें इस वीडियो में.. inovance Servo जैसे कि SV630A SV630B SV630P SV660P इन सभी sarvo ड्राइव के पैरामीटर same ही हैं
Inovance servo drive Parameter setting Before JOG Mode Testing.... Solve...!! JOG Mode Not Working..
Просмотров 1,3 тыс.9 месяцев назад
inovance servo drive SV630 SV630A SV630B SV630P SV660P PARAMETER SETTING BEFORE JOG MODE ENABLE... #automation #servo #servomotors
Inovance Servo Drive SV630A SV630C SV630P SV660P JOG Mode Testing जोग मोड पैरामीटर्स सेटिंग कैसे करे
Просмотров 7429 месяцев назад
#automation #inovance #servo Inovance की सर्वो SV630A SV630C SV630P SV660P को JOG मोड पर कैसे टेस्ट करते हैं उसके पैरामीटर की सेटिंग कैसे करते हैं वह हम इस वीडियो में देखेंगे
Data Loading.... PLC1 Communication Error Time-Out... HOW TO OPEN MONITOUCH HMI MENU... Fuji HMI
Просмотров 1,5 тыс.10 месяцев назад
इस वीडियो में मैं MONITOUCH HMI TS1070 का use कर रहा हूं... इसको ON करने पर इसमें Data Loading... और PLC1 Communication Error Time-Out..... Show होता है... क्या HMI सही है... इसको समझते हैं.... #MONITOUCH #hmi #fuji #automation #repair #electronic
Schneider Servo JOG Mode Not Working or Srv_On servo On Error Problem servo Jog Mode Problem #Servo
Просмотров 12711 месяцев назад
Schneider Servo JOG Mode Not Working or Srv_On servo On Error Problem servo Jog Mode Problem #Servo
Schneider Servo Drive Repairing LXM23D Servo Drive रिपेयर करना सीखें हिंदी में Servo Drive Repairing
Просмотров 70211 месяцев назад
Schneider Servo Drive Repairing LXM23D Servo Drive रिपेयर करना सीखें हिंदी में Servo Drive Repairing
Siemens S7 200 Transistor Type PLC Repairing... Output and SMPS Section MOSFET and 15V faulty Zener
Просмотров 9311 месяцев назад
Siemens S7 200 Transistor Type PLC Repairing... Output and SMPS Section MOSFET and 15V faulty Zener
Delta Servo Drive JOG Mode Parameter Setting Step By Step and Forward Reverse Testing आसान तरीके से
Просмотров 1,7 тыс.Год назад
Delta Servo Drive JOG Mode Parameter Setting Step By Step and Forward Reverse Testing आसान तरीके से
Yaskawa Sigma Servo Drive JOG Mode Step By Step Parameter Setting and Testing
Просмотров 1,4 тыс.Год назад
Yaskawa Sigma Servo Drive JOG Mode Step By Step Parameter Setting and Testing
How use Yaskawa SigmaWin+ and Yaskawa Servo Communication and How to Run Yaskawa Servo On JOG Mode
Просмотров 671Год назад
How use Yaskawa SigmaWin and Yaskawa Servo Communication and How to Run Yaskawa Servo On JOG Mode
CNC Machine Controller keypad Testing Keypad Repairing...
Просмотров 159Год назад
CNC Machine Controller keypad Testing Keypad Repairing...
Mitsubishi Servo Drive MR J2 Repairing Testing IGBT J2-Q series IGBT J2-Q16A-C Datasheet C364C102H01
Просмотров 1,7 тыс.Год назад
Mitsubishi Servo Drive MR J2 Repairing Testing IGBT J2-Q series IGBT J2-Q16A-C Datasheet C364C102H01
How to Repair delta VFD Delta AC Drive Repairing… Delta AC Drive Power Card Firing Section Repairing
Просмотров 9 тыс.2 года назад
How to Repair delta VFD Delta AC Drive Repairing… Delta AC Drive Power Card Firing Section Repairing
ATV310 2Wire & 3Wire Parameters Settings, Stop Forward Reverse Wiring & Parameters Setting in Hindi
Просмотров 13 тыс.2 года назад
ATV310 2Wire & 3Wire Parameters Settings, Stop Forward Reverse Wiring & Parameters Setting in Hindi
How To Install ATV310 Power Connection & Control Wiring.. Schneider ATV310 VFD की वायरिंग कैसे करें
Просмотров 6 тыс.2 года назад
How To Install ATV310 Power Connection & Control Wiring.. Schneider ATV310 VFD की वायरिंग कैसे करें
How To Install Delta VFD for Basic Operation, Delta VFD M Delta Drive की सेटिंग कैसे करें
Просмотров 6 тыс.2 года назад
How To Install Delta VFD for Basic Operation, Delta VFD M Delta Drive की सेटिंग कैसे करें
Altivar71 Testing After Service 40HP 3Phase
Просмотров 522 года назад
Altivar71 Testing After Service 40HP 3Phase
INVT VFD Factory Reset setting Parameter INVT GD10 Drive INVT Drive or INVT Inverter Part 3
Просмотров 25 тыс.2 года назад
INVT VFD Factory Reset setting Parameter INVT GD10 Drive INVT Drive or INVT Inverter Part 3
How to Install INVT On Remote Mode, INVT VFD Ki Wiring Setting Kaise Karen Part 2
Просмотров 13 тыс.2 года назад
How to Install INVT On Remote Mode, INVT VFD Ki Wiring Setting Kaise Karen Part 2
How To Install INVT Drive INVT VFD Run Command Parameter setting Part 1 INVT VFD Setting
Просмотров 22 тыс.2 года назад
How To Install INVT Drive INVT VFD Run Command Parameter setting Part 1 INVT VFD Setting
SMPS Repairing 24V DC Power Supply Repairing & Electronic Components Testing & Troubleshooting
Просмотров 1982 года назад
SMPS Repairing 24V DC Power Supply Repairing & Electronic Components Testing & Troubleshooting
Use fully videos
🙏😊
Please aur videos bnaye🙏🙏
2-3 din mei upload karta hu
Mujhe next video ka intzaar hai....
Theek hai... Mai 1 ya 2 din mei Fir se dalunga
Please help
Han ji
GD10-OR4G-S2-B ko key pad se chlana hai sir kya karu
iski bhi Video 1-2 din mei he Dalta hu
ruclips.net/video/W0z0xsEZtJI/видео.html
ruclips.net/video/ZponozYhIKc/видео.html
Hii
Hii
Sir can it's RS485 works
@@hanzlarehman968 Han Kaam Karta hai
manual books me sari setting hoti hai😅😅😅😂 me bata raha hu❌
Manual
Bhai iss machine me kitna amp ka transformer lagta hai
@@ansaritechnicaladda 3 se 4
Plz contact number mere vfd repair krwani hai
Kon si
Sir namaste Agar forward aur reverse ek hi jagah ek hi time chalne ka videos banaye aur parameter seting bataye
Ek he jageh hai... Aap kya kehna cha rahe ho...
Sir thanks for your input. Nice explanation. Can you please guide how to take parameters backup
Download software from PLC247.com
Nothing happening by enter button. For delta vfd ms300
MS300 mei nahi....EL series
Mere waale mai same problem only 5 volt show karte hei. Koyi volume kam nehi karte hei
Hmm potentiometer change kijiye
А как сбросить какие комбинации набирать?
plchmiservo.com/inovance-drive-inodrive-shop-v2-0-3-inovance-servo-software/ Download this software and use ...
А сбросить как-то можно? И какое значение должно быть?
Using PC for Reset this alarm or Factory Reset for Thr Servo Drive...
Ошибка сервопривода е630.0 в чем причина SV660P сервопривод
1- 1st Check Motor U V W Phase Sequence..
One of delta drive display shows 88888 wht may the problem
Is Delta Drive Is El or E series then Change Control card
I tried this, but - - 06 code keeps appearing at times and motor stops running. I was using 2 wire control, 4 wire, 0 to 10VDC sensor given. L1 as start signal. Any clue why? And how to resolve the issue?
--06 stands for NST is not a fault but means the drive is in an freewheel stop condition. Causes and fixes : 1. VFD has an input assigned to Freewheel stop? Check to see if that the input is active. 2. The drive is in 3 wire control (201 =3C). LI1 must be active before the NST will clear. 3. The VFD is in 2 wire control (201 = 2C) Verify if the drive was powered with the run command active, if so cycle the run command or set 202 to 01 (LEVEL) IO menu, 2 wire type = level 4. If the drive is being controlled by serial communication, the drive will display --06 until the Hex value of 6 has been written to the command word. 5. If the 4-20 mA signal loss is programmed to freewheel stop and the drive has loss the signal. Check the 4-20 mA signal. 6. If the drive is running from terminal control and the stop button on the keypad or remote display is pressed, the drive will go to --06. Power cycle the drive to clear the --06.
@@troubleshoottech3605 thanks
Sir pronet e 10 d m pot dot aarha h servo motor nhi chal rhi kya problem hai
@@lovepaniyal3935 Jog par test karo .... Kisi kisi drive mei Factory reset karne ke baad pot ata hai ....
@@troubleshoottech3605 please explain esa kyu horha h phle drive running m tha
Ye terminal wiring ka sign hai .... Terminal wiring disable karo ya POT ke parameter ko disable karo....
@@troubleshoottech3605 okk terminal wiring disable krne k baad bhi nhi hua Pot ka parameter konsa h
PN000.1 or Pn000.2
How to sansor connected npn no premeter
Kuch bhi samajh nahi aya kya punchna cha rahe ho....
What about Er.b03
Ye ya to programming related issu hai nahi to encoder ki taraf se problem aa rahi hai....
Error 14 Panasonic A4 how to remove?
Ye over current ka alarm hai... But is alarm ane ki condition Kiya hai... Kya Servo drive mei supply dete he alarm aa raha hai....ya Servo on ka singnal Dene par aa raha hai...ya Servo thoda chalti hai tab alarm ata hai....
@@troubleshoottech3605 servo on krty hi ajata hai and sometimes on krty bhi ata hai
CT or Firing section mei Problem hogi ...
@@troubleshoottech3605 please send contact number
Sir main Pakistan se ho Toyota Air loom electronic lab repairer ho mujy ap ki yh video se bot help mili hy plz ap mujy servo card or motor ki wiring bata saky hy with pc...
Manual download kijiye ....
Good work
😁
Contact number bhai ji
DP par hai
where software donwload
Plc247.com
Sir up ka phn no
DP par hai
bhai 1hp motor sudui fwd a ki vabe chalbo with on/off switch and potentiometer diye , er parameter gulo ki debo ebong potentiometer konta use kobo please ektu guide koren.
🙄
@@troubleshoottech3605 appka replied emoji ka matalab samjha nahi , kya aap bata skte ho mujhe invt gd20 ka ye configuration
@souravb387 hmm mujhe language samajh nahi aathi
@@troubleshoottech3605 oh... aap kahase ho india me???? ye chanel bangla desh ka hai isliye maine bengali me pucha tha inko , mai west bengal se hu . kya aap ka contact no mil sakta hai ???
Bangal se ...??? Kaha likha hai
Terminal not working. How to solve this???
Check my other video ... For local(Keypad) and Remote(Terminal) mode
I run Speed Mode but when DI 1 ON / SERVO ON the motor immediately spins slowly ? Can you help me sir ?
Check zero speed parameter
And Also check Input Pulse in Servo using Servo Display Parameter
@@troubleshoottech3605 thank you sir,I'll check it
Sir frequency 22 se start ho rahi hai 1 se nahi ho rahi hai
Sir is per koi video bnao
@@vikashtanwar6495 Iske kuch reason Ho sakte hain . 1-minimum Frequency 22 set hai …. 2- Preset speed par drive set Ho Sakti hai …… or Minimum Reference Usko 22Hz ka Mil raha Ho …
Thanks sir
Sir ATV320 ko details se samjha den
Abhi kaha samajh nahi aya
Not working
Factory reset ke baat try karo
Sir pls ye bta do fc 301 mai apne bina capacitor bank lgaye kaise drive on ki hai checking ke liye meri drive mai input side igbt burnt tha lgaya to W27 ka fault a rha hia
Positive Negative
@@troubleshoottech3605 input mai ac supply nhi deni uski jgh sirf DC supply jha 560 vdc ati hai wha deni hai supply uske baad display on ho jayegi fir Bina capacitor or choke lgaye bina
Yes
@@troubleshoottech3605 W27 alarm a rha hai brake chopper ka kya check kru sir danfoss FC301 Mai 22 kw
Brake Parameter disable karo... Manual mei brake ka parameter dekho.. or usko disable karo
Sir Acl problem how solved pls help 7.5hp
Check a Small card in your drive Which is Give Firing signal to Gate of the IGBT … this card Also Know as ACL card Also
Firing hm check krenge sir drive ke connection kaise honge igbt ko bahar nikal diya uske baad kyonki igbt check kr liya shi hai alarm gff a rha hai Vfd-E series hai drive
Ok
Sir igbt nikal ke kaise connection kr ke firing check krenge pls help kr do mere 15 kw delta drive mai gff fault a rha hai
CT check karo...
CT check kr liya sir ok hai aap firing ka bta dete kaise check krte hai mai voltage check kr leta
A alarm current section ka h
Ok
Bhai input section ka hota to manual me clear bataya hota
Ok
Inovance servo error 20 what problem bro😢
Complete Model Number batao...
Supply ic Konsa h
TNY2806N
Bro short circuit
Kiya hai wo
Inovance servo me err 770 aa rha what to do
Check phase A wire of encoder... When you test Phase A wire Using a Multimeter then Should be beep sound both side of Phase A wire....
@@troubleshoottech3605 sir encoder cable ok. Durning line run .some time this problems occur ,but after reset ,it work properly. some times occur this problem ,what to do??
Encoder problem
Error 770 fault??what to do
Encoder
Phase A
Pleace share sigma win + software
drive.google.com/file/d/1DN59_bjMAPjJZ9gl5fOXu7w4IEnWjp6H/view?usp=sharing
Password Extract: plc247.com
@@troubleshoottech3605 thank you
Sir CFF show kar raha hain aur koi function work nahi kar raha hian ? Kya kare
Parameter FCS mei INI set kar do .....
@@troubleshoottech3605 drive kharab thi
sir mere pas 5hp delta m modle ki vfd h .iski igbt short thi , check kane per pta chla smps ki winding bi open the ,ab new smps lga diya h , drive on ho gai h but mosfet k2225 heet ho rha h , sab kuch dusri drive ke sath match bi kar chuka h but problem solve nhi ho rhi h. dirve me 1 h supply de ke rkhha koi problem nhi hui but mosfet heet ho rha h .plz solutions btaye
K2225 MOSFET ke Gate par Supply nahi aa rahi hai.... Koi na Koi Resistance ya Diode kharab hoga SMPS section mei...theek se check karo... Ya SMPS IC bhi Kharab ho sakti hai Output na de rahi ho...
Open the window and let it fly. It's not worth your time.
Thnx 😊👍