Commercial Refrigeration & HVAC Essentials Inc
Commercial Refrigeration & HVAC Essentials Inc
  • Видео 46
  • Просмотров 1 508
To use OEM or Non-OEM Controllers?
Listen in on a service call part 2 of a RIF that is still down due to someone not using the right controller
Просмотров: 52

Видео

Upright 6 door reach in freezer warm on New Years Eve
Просмотров 46616 часов назад
I am dispatched 3.5 hours away to look at a problematic freezer for a customer
Send me your service & install videos
Просмотров 1319 часов назад
I can’t post enough service videos so send me yours and I will share them for all to see and learn from what’s really in the service realm today!
HVAC Communication?
Просмотров 42День назад
Communication between the customer and the tech is going downhill and is causing customer service issues.
Changing a pulley on a Carrier rooftop Part 2
Просмотров 17Месяц назад
Created with the #GoPro App on my iPhone.
Changing a pulley on a Carrier rooftop Part 1
Просмотров 74Месяц назад
Created with the #GoPro App on my iPhone.
Monday morning call diagnosis and repair
Просмотров 11Месяц назад
Created with the #GoPro App on my iPhone.
First call on Monday
Просмотров 5Месяц назад
Created with the #GoPro App on my iPhone.
Drive up the mountain from Estes Park to Loveland
Просмотров 14Месяц назад
Created with the #GoPro App on my iPhone.
Why are technicians treated like sh**?
Просмотров 5Месяц назад
Fair warning ! If technicians keep being treated like bottom dwellers , we all will be ran out of the industry. This is my perspective on the challenge.
Changing a pulley on a rooftop unit. Part 1
Просмотров 19Месяц назад
Tricks on changing a pulley
The Obstacle is the Way
Просмотров 12Месяц назад
Use the energy of obstacles to your advantage.
No heat call. I think I have a bad heat exchanger. Going off on rollout. Or do I?
Просмотров 254Месяц назад
Never seen this before. I almost mis diagnosed this rooftop
November 20, 2024
Просмотров 5Месяц назад
November 20, 2024
The Borg…..Be ready to be assimilated in 5 years time!
Просмотров 3Месяц назад
The Borg…..Be ready to be assimilated in 5 years time!
How to diagnose an IceoMatic 1800 remote ice machine
Просмотров 52Месяц назад
How to diagnose an IceoMatic 1800 remote ice machine
More steps in starting your own business
Просмотров 62 месяца назад
More steps in starting your own business
You need to sell yourself to be promoted in this industry? Part 2
Просмотров 82 месяца назад
You need to sell yourself to be promoted in this industry? Part 2
I asked twenty something how he liked being in our industry. I was surprised at his response
Просмотров 52 месяца назад
I asked twenty something how he liked being in our industry. I was surprised at his response
We don’t micromanage….but our software does? Yes it does
Просмотров 82 месяца назад
We don’t micromanage….but our software does? Yes it does
Heed my warning! If this does not change, you will never have the amount of Service Technicians
Просмотров 82 месяца назад
Heed my warning! If this does not change, you will never have the amount of Service Technicians
Return to the office or you’re fired!
Просмотров 112 месяца назад
Return to the office or you’re fired!
How to resolve the customer purchasing their own parts issue
Просмотров 93 месяца назад
How to resolve the customer purchasing their own parts issue
Sending technicians to a service call with a skill set is the exact opposite of what you should do
Просмотров 183 месяца назад
Sending technicians to a service call with a skill set is the exact opposite of what you should do
Follett ice machine so down again!
Просмотров 133 месяца назад
Follett ice machine so down again!
If this trend continues …..our industry is doomed!
Просмотров 124 месяца назад
If this trend continues …..our industry is doomed!
The elusive headmaster. How diagnose a headmaster on an ice machine.
Просмотров 494 месяца назад
The elusive headmaster. How diagnose a headmaster on an ice machine.
How to diagnose evaporator ECM motors and “I have the parts”
Просмотров 94 месяца назад
How to diagnose evaporator ECM motors and “I have the parts”
How long has technicians been mislead? Listen in to that answer and how we can fix it. I
Просмотров 104 месяца назад
How long has technicians been mislead? Listen in to that answer and how we can fix it. I
Are you going to choose the right thing to do as an employer or a technician?
Просмотров 114 месяца назад
Are you going to choose the right thing to do as an employer or a technician?

Комментарии

  • @bruceorourke5432
    @bruceorourke5432 День назад

    Can't get those controllers from ranco I don't have the number over the counter United Refrigeration try one

  • @bruceorourke5432
    @bruceorourke5432 День назад

    I agree with that I never had good luck with it that's why I switched

  • @bruceorourke5432
    @bruceorourke5432 День назад

    I use Ranco is the same as a Drexel will take his place recent cooler are freezer they have a good tech support Ashley's owned by I think Robert Shaw also can you use 18 gauge thermostat wire if the wires on the thermistors ain't long enough I used a couple they were fine

  • @BixRivers.
    @BixRivers. 3 дня назад

    I don’t think female dogs are into peeing on fire hydrants 🤠

  • @BixRivers.
    @BixRivers. 3 дня назад

    Nice video. I just subscribed. Happy New Year

  • @WswRefrigeration
    @WswRefrigeration 4 дня назад

    I pretty much use dixells on everything. If you know how to wire them and go through the settings (which is very simple)

  • @WswRefrigeration
    @WswRefrigeration 4 дня назад

    So why are the heaters not working? No way there’s 2-3 bad dixells in a row . All it does is send 115 hot leg out on terminal 7 , if you have 115 there then there’s another issue

    • @CommercialRefrigerationHVACEss
      @CommercialRefrigerationHVACEss 4 дня назад

      And here lies in the problem in todays service world. I was sent on this because there have been multiple problems with this unit. I do not know how many Dixel controllers have been changed. All I know, with Hussman factory support, that the Universal replacement Dixel was not powering the relay for the defrost heaters. So that makes one Dixel Controller bad. The one in the box is for a cooler, not a freezer so I cant use that one. I will have a video followup after I change the the replacement OEM controlller. Dixel can be easy, especially on cooler s and certain freezers. No doubt, this is a previous techs incompetence and wiring the unit he wanted it to be. when I am thrown into situations like this, I start from scratch and calll the factory and follow their direction. The first thing he said is "why do technicians install OEM controllers? I replied....I don't know. He said we need to start from scratch and install factory parts. Thats where I am now

  • @MariosACandRefrigeration
    @MariosACandRefrigeration 4 дня назад

    When the evap.sensor is out,you can manually defrost it,by connecting line to the defrost line,and you can disconnect the compressor line,on the controller.you need to change FC from oy to on,so the fans turn off on defrost.d1 is room temp,d2 is evap temp,if it is no good it will not defrost.hope that helps.the controller they install was set for a cooler.

  • @WswRefrigeration
    @WswRefrigeration 7 дней назад

    I would have pulled the bottom row of product then melted the ice with hot water and get them up and running. Dixells are super easy for the settings. Google search universal dixell manual and it pops right up

  • @carlosdominquez1456
    @carlosdominquez1456 18 дней назад

    Ok good call I thought run Cap was Bad but your are right Safety First nice Video

    • @CommercialRefrigerationHVACEss
      @CommercialRefrigerationHVACEss 17 дней назад

      @@carlosdominquez1456 Thank you Carlos. Yes…..diagnosing a bad part is one thing, repairing it for longevity is another. I try to do the latter for the best value to the customer

  • @timparsons7348
    @timparsons7348 29 дней назад

    Could be. Seems a little high in my experience. It’s usually around 180 PSIG bypass pressure.

  • @danhelsing8860
    @danhelsing8860 Месяц назад

    Seems like most hoshis open at 180 and close at 225 on 404 , hard to tell when the remote’s data label is non legiable and neither is the valve data

  • @KevinKinder-ey9gv
    @KevinKinder-ey9gv Месяц назад

    Maybe the phases are wrong

    • @CommercialRefrigerationHVACEss
      @CommercialRefrigerationHVACEss Месяц назад

      That is a great deduction since two loads are running in the wrong direction. The Induced Draft motor is a single phase PSC motor so the wiring of the phase to the unit would not be the problem. Thank you for your very insightful comment. I truly appreciate it

  • @timparsons7348
    @timparsons7348 3 месяца назад

    Apparently I didn’t verify the sound settings on the recording software. I will redo this video soon.

  • @michaelmeucci8785
    @michaelmeucci8785 5 месяцев назад

    Nice to me I watch the whole thing