Installation of a Heatshrink Termination on a Three-core MV Armoured Cable
Просмотров 175 тыс.7 лет назад
This video by REPL shows the installation of a Heatshrink Termination on a Three-core MV Armoured Cable. *This video is property of REPL International Ltd* REPL reserve the right to update the information contained in this document at any time without notice. It is the users responsibility to ensure it is suitable for the intended application. Any implied warranty relating to fitness for a part...
Installation of a Heatshrink Straight Joint on Three-core MV Armoured Cable
Просмотров 46 тыс.7 лет назад
REPL Installation video of a heatshrink straight joint on three core MV armoured cable. *This video is property of REPL International Ltd.* REPL reserve the right to update the information contained in this document at any time without notice. It is the users responsibility to ensure it is suitable for the intended application. Any implied warranty relating to fitness for a particular purpose a...

Комментарии

  • @AfricanTalesWithNma
    @AfricanTalesWithNma 23 дня назад

    I have my Industrial training presentation today, this is really helpful

  • @AzreenJafaar
    @AzreenJafaar 24 дня назад

    Amazing job🎉

  • @anphan6905
    @anphan6905 2 месяца назад

    💓💓💓

  • @dimk6522
    @dimk6522 2 месяца назад

    Where is the earth conductor?

  • @pannierselvamsanthoshkumar8958
    @pannierselvamsanthoshkumar8958 4 месяца назад

    Good video i will like it

  • @cristianrojaschamorro
    @cristianrojaschamorro 5 месяцев назад

    THIS WORK IS VERY VERY FAILED.

  • @dewangisirftumsa5349
    @dewangisirftumsa5349 5 месяцев назад

    I m cable jointer from Pakistan i need canda cable jointer job

  • @hocinedjaborebbi7458
    @hocinedjaborebbi7458 6 месяцев назад

    excellent travail

  • @patterdalezipsuzilil
    @patterdalezipsuzilil 7 месяцев назад

    I got told off once for using a Stanley knife instead of a penknife

  • @kyaligonzajohn107
    @kyaligonzajohn107 10 месяцев назад

    Thumbs up 👍 for sharing this useful content.

  • @omargarcia9132
    @omargarcia9132 Год назад

    Did I miss the step where he pulled back the concentric shield and installed that metal clamp? It all of a sudden showed up mid video 😊

  • @mohammadsabirkhan1560
    @mohammadsabirkhan1560 Год назад

    What is this monstrosity?

  • @KrishnaKumar-zz7dm
    @KrishnaKumar-zz7dm Год назад

    Good

  • @rxchester3364
    @rxchester3364 Год назад

    This video release 5 years ago but only have 117k viewers, kinda rarely electrical engineers 🥴

  • @fabiogarcia1431
    @fabiogarcia1431 Год назад

    Can I use these cables to charge my smartphone? LoL

    • @souravgandhi977
      @souravgandhi977 7 месяцев назад

      😂😂

    • @lobbyhoe01
      @lobbyhoe01 7 месяцев назад

      You absolutely could, just wouldn’t be very practical to have a cable many times larger than your charging brick.

  • @Pathfindor
    @Pathfindor 2 года назад

    No PPE?

  • @muazabduljamil2237
    @muazabduljamil2237 2 года назад

    cool3

  • @neilm84b97
    @neilm84b97 2 года назад

    Now show me in a muddy wet hole with a 5 inch ground clearance

  • @elektricalchannel9784
    @elektricalchannel9784 3 года назад

    Ok👍

  • @Game-cr8pg
    @Game-cr8pg 3 года назад

    Tndtns ns 😥😱

  • @ericjx
    @ericjx 3 года назад

    Lol, this seemed a bit haphazard compared to other ones of these I’ve watched.

  • @coldfire0101
    @coldfire0101 3 года назад

    why has he now got wire coming out of the jacket ?? you broke that off

  • @nomfanelomthembu9242
    @nomfanelomthembu9242 3 года назад

    Can I have the measurements please

  • @AmirKhan-vm6uo
    @AmirKhan-vm6uo 3 года назад

    Good job 👍

  • @mdzahid5120
    @mdzahid5120 3 года назад

    Very nice

  • @mdzahid5120
    @mdzahid5120 3 года назад

    Very Nice Good GOB MD ZAHID Malaysia

  • @hartshacks6445
    @hartshacks6445 3 года назад

    Wouldn’t it make more sense to just have one continuous shrink tube instead of two and putting mastic in between

    • @kylesenior
      @kylesenior Год назад

      That requires you to have longer free lengths of cable on an end for the heatshrink to rest while doing the connection. This might no be possible inside conduit or in a pit.

  • @rihanaentertainment3848
    @rihanaentertainment3848 3 года назад

    sample work if u work direct site not like that different little bit.

  • @andey12chanel
    @andey12chanel 3 года назад

    Thanks for sharing this content

  • @edgarsilva1024
    @edgarsilva1024 3 года назад

    Thank you for the your exercise brother

  • @ellemcc2547
    @ellemcc2547 3 года назад

    @3:32 What are those "springs" called?

    • @fivefourfivebythreenine337
      @fivefourfivebythreenine337 3 года назад

      They're called "constant force springs". Supplied with all KV term kits for tape shielded cable.

  • @tuateaaukino9924
    @tuateaaukino9924 4 года назад

    2:02 always cut away from yourself 😂😂 Craftsman 🤙🏼

  • @commercialelectrician133
    @commercialelectrician133 4 года назад

    Where can I get the item so I can learn to do this

  • @espotek
    @espotek 4 года назад

    Please use hand glove for safety

  • @dharmasingh7999
    @dharmasingh7999 4 года назад

    Very cool thank you sir

  • @yensabi
    @yensabi 4 года назад

    Got to be an easier way to do this , too much to go wrong...!!

  • @Doti_231
    @Doti_231 4 года назад

    What you called cable gland for MV cable and what material is?

  • @manni02
    @manni02 4 года назад

    What will happen if the length of anti tracking tube of 6.6kV 3Core termination kit is reduced at site due to constraint of terminal box dimension.. assume supplied length of anti tracking tube is 500mm and we reduced it at site to 450mm

  • @dawoodjanmychannel3400
    @dawoodjanmychannel3400 5 лет назад

    Wow very good

  • @kitsouk1
    @kitsouk1 5 лет назад

    What is the service life for this joint?

  • @clampinmotion2430
    @clampinmotion2430 5 лет назад

    1KM cable connected... oh shit I forgot to put heatshrink tube before connect it.

  • @megamanwins
    @megamanwins 5 лет назад

    Very useful videos! can you cover more of this topics?

  • @keenemolefe1631
    @keenemolefe1631 5 лет назад

    wonderful

  • @keenemolefe1631
    @keenemolefe1631 5 лет назад

    wonderful

  • @alinili5569
    @alinili5569 5 лет назад

    I never seen selling this kit any where I watched a joiner once on street he was branching off to the block of flat I had the contract to do it was very interesting but he said. They only make them and supply to southern electric Thanks for the video

    • @douro20
      @douro20 4 года назад

      You can still buy the components. They also make a cold-shrink solution.

    • @syedmurtazahassam7236
      @syedmurtazahassam7236 4 года назад

      I sell armoured cage only which is an important part of cable joint and we make it of good quality 1mm thick polished prime sheet of all sizes if you want any go to my page (Armour case of cable)...

  • @ayrendraganas8686
    @ayrendraganas8686 5 лет назад

    hey this video actually looks like how someone would do it in the field; no specialized tools like cable strippers, but whatever is at hand like a knife

    • @ayrendraganas8686
      @ayrendraganas8686 5 лет назад

      well, not entirely, but still way more believable than all the other videos like this out on youtube

    • @dpvng.dpvng.
      @dpvng.dpvng. 5 лет назад

      yeah especially how shielding wires magically appears at 7:05

    • @karimkhan985
      @karimkhan985 5 лет назад

      Yellow filler tapes not proper uniform

    • @JasperJanssen
      @JasperJanssen 5 лет назад

      That’s clearly not a “whatever is at hand” knife, that’s a “I’ve had this knife for 30 years and I know *exactly* how sharp it is” knife.