Richard Marlow
Richard Marlow
  • Видео 19
  • Просмотров 116 764
Airflow Adroit Cloud MVHR Control Interface
Here is a short video I did for one of our clients who was on holiday at the time of Commissioning. This premium MVHR system was part of a Deep retrofit. This video is a brief summary of the Excellent cloud-based control system. I hope it is of use to someone.
Просмотров: 47

Видео

ASHP & MVHR working in perfect harmony, this building fabric has led to no need for space heating.
Просмотров 2,6 тыс.Год назад
All of the sustainable retrofit work and engineering carried out by Ariva Renewables www.ariva-renewables.co.uk This A-rated EPC, Eco-Retrofit, Boasts the Following Technology 5.7kW Inset Solar Array and Battery storage with Hybrid Inverter. Airflow DV145 Adroit MVHR with remote monitoring Hitachi Yutaki Monoblock 11 kW ASHP 500 ltr Hot water Cylinder Serving 6 Occupants Remote Hot water circul...
Wufi Plus Whole Building Simulation
Просмотров 1,9 тыс.2 года назад
Wufi Plus Whole Building Simulation
Airflow Adroit Condensate Trap Assembly
Просмотров 5834 года назад
A short video showing how to connect the European bottle trap to 21.5mm overflow pipe
Zehnder MVHR condensate trap arrangement
Просмотров 2,4 тыс.4 года назад
A short video showing how to get uk plumbing fittings to work with zehnder MVHR'S
Zehnder q600 with comfocool condensate arrangement
Просмотров 9 тыс.4 года назад
Probably the best MVHR set up in the World.
Build Tight Ventilate Right
Просмотров 3224 года назад
Solarcrest recommend Pro-clima Airtightness solutions
MVHR Room Valve installation
Просмотров 1,1 тыс.4 года назад
For the perfect airtight finish please follow the advice in this video. Plasterers play a key role in delivering an efficient MVHR system. 01625 423020 www.solarcrest.co.uk
Roof Waterproofing Using Polyurea
Просмотров 1834 года назад
The fastest way to cover any flat roof. Polyurea is the most robust finish there is. For a quotation please call 01625 423020 www.solarcrest.co.uk
Finding the sweet spot when commissioning
Просмотров 8874 года назад
Vent axia sentinel B
MVHR, what can it do?
Просмотров 1,8 тыс.4 года назад
MVHR or Mechanical Ventilation Heat Recovery has many other benefits, amazing energy recovery is not the only positive attribute. Check out this video for the full brief in an easy-to-understand Northern Dialect. For any info or if you would like to enquire, please call: 07985 174736 www.ariva-renewables.co.uk
Sound Pressure Testing of Vent Axia MVHR
Просмотров 1,4 тыс.5 лет назад
Measurement of breakout and vibrational noise produced by MVHR in Roof Space. Result = Whisper quiet www.solarcrest.co.uk
AIRFLOW DV145 Adroit
Просмотров 2,8 тыс.5 лет назад
A brief overview of a basic MVHR installation For more information and quotations contact: www.ariva-renewables.co.uk
Super airtight, vapour open Roof insulation
Просмотров 1226 лет назад
Super airtight, vapour open Roof insulation
Boost Switch with no wires or batteries and no mess
Просмотров 3397 лет назад
Boost Switch with no wires or batteries and no mess
Vent axia sentinel B+ control module
Просмотров 60 тыс.7 лет назад
Vent axia sentinel B control module
Typical Installation Vent Axia Sentinel B+
Просмотров 31 тыс.7 лет назад
Typical Installation Vent Axia Sentinel B

Комментарии

  • @XxKP2606xX
    @XxKP2606xX 12 дней назад

    Mine is constantly on Control mode Fan off, does anyone know how to fix that or turn it back on?

  • @lukehawkins935
    @lukehawkins935 19 дней назад

    I put mine in diagnostic mode and can’t get it out, any help?

  • @RickyBobbyNASCARLOVER
    @RickyBobbyNASCARLOVER Месяц назад

    I’m so dumb I still don’t understand, if I want to cool my house what do I do? It’s 30c outside right now, my inside temp is set at 16c (lowest it can go) and my outside temp is set at 20 (highest it can go) and then summer mode is set to ON

  • @HitachiCoolingHeatingGlobal
    @HitachiCoolingHeatingGlobal 2 месяца назад

    Hello, I am contacting you on behalf of Hitachi Cooling & Heating. We were very impressed by the installation you shared in your post and would love to share your work on our social media channels. With your permission, we would like to use your content on our social media and other communication channels to showcase real-life examples of air conditioning installations. If you agree, could you provide us with some additional details about your installation? We would like to know: The location of the installation (city or region). The equipment installed (equipment model). Any additional specifications you consider relevant (e.g. special features of the equipment, energy efficiency, etc.). Of course, we will give you full credit for your content and be sure to link to your profile. Thank you very much for considering our application! We look forward to sharing your experience with our community.

  • @daviddaniels9217
    @daviddaniels9217 3 месяца назад

    You are a very good presenter Rick. Brilliantly and clearly explained. Thank you.

  • @alexwang9983
    @alexwang9983 3 месяца назад

    why is the boots airflow mode still on?

  • @rdvankaygusz1583
    @rdvankaygusz1583 3 месяца назад

    there is no normal airflow on mine is there a setting for that

  • @chanelus402
    @chanelus402 3 месяца назад

    Hi this vent is making me sick the air it brings inside smells like chemicals it is screwing our health. Is there any option to only push bad air from inside to outside instead of getting air from outside in? Please let me know asap

  • @harshitchoudhary8275
    @harshitchoudhary8275 4 месяца назад

    How to turn off this? Bcz I'm facing a noise issue in my apartment.

  • @Roamwithsushi
    @Roamwithsushi 4 месяца назад

    The boost airflow automatically turns itself on stating boost airflow 47%. How can I turn this off ? I’m concerned about the electricity it consumes while being in that mode. Also, any rough idea how much electricity it actually consumes ?

    • @danyalabdullah7435
      @danyalabdullah7435 26 дней назад

      I'm having the same prob. Were you able to figure out how to turn it off? Thanks

  • @0-Will-0
    @0-Will-0 4 месяца назад

    Solarcrest did our install in about 2016. Did a good job and no problems since. Having MVHR is highly recommended.

  • @stooplow9936
    @stooplow9936 5 месяцев назад

    Hi I've just moved into a new place and it has a sentinel multivent A. It's black with an lcd screen in the top right corner with 3 buttons. There's no instructions on how to set it anywhere. I've looked on the internet with no luck. You wouldn't happen to know how to program it so the low normal and boost settings can be changed to different times? Thanks in advance.

  • @jamesl8868
    @jamesl8868 5 месяцев назад

    I've just moved into a flat and the system consistently remains on Boost Airflow 70%, despite me changing the normal mode hours from 7am to 10pm. Any ideas how I can get it to move to normal or even low mode to reduce the noise & electricity used?

    • @Irishrover11
      @Irishrover11 4 месяца назад

      Hey! I'm stuck on boost as well!! Did you figure out how to get it to normal? Cheers

    • @jamesl8868
      @jamesl8868 4 месяца назад

      @Irishrover11 It turns out our unit is configured to go on boost for 12 minutes whenever a bathroom light has been switched on, so in a larger household it always seems to be boosting for us

  • @xxxx-wv6hp
    @xxxx-wv6hp 5 месяцев назад

    Since I moved to my brand new apartment I started getting sick with the nasty air coming out from my vent axi built in on my apartment why is that? The filters are clean nothing really happening I am now thinking maybe they installed something wrong of there is impure air connected to the tubes bringing nasty air in, any idea?

  • @xxxx-wv6hp
    @xxxx-wv6hp 5 месяцев назад

    It’s bringing nasty toxic air inside my apartment and it’s brand new what that can be?

  • @OuraInFlames
    @OuraInFlames 7 месяцев назад

    Wasn't clear on the humidity bit. If the air in your home is quite dry and uncomfortable, what percentage should you put it to?

    • @richardmarlow4466
      @richardmarlow4466 7 месяцев назад

      Relative Humidity is relative to temperatue . Specific humidity of 7-8 grammes per Kilogramme of air which is pretty much 1 Cubic metre of Air, this is optimum.

  • @terr0riz3
    @terr0riz3 7 месяцев назад

    Useful video.What does defrost mode do. I can't get it off that atm

    • @richardmarlow4466
      @richardmarlow4466 7 месяцев назад

      it will tun off the supply fan or the MVHR until it thinks the heat exchanger is safe, dont mess with this.

  • @stephencrotty8826
    @stephencrotty8826 7 месяцев назад

    @richardmarlow4466 what settings would you recommend for cold winter temps ? From say 0 degrees to 8 ? Should indoor temp be mid 20’s ? And outdoor be quite low setting? And also what would normal supply and low supply be ? Thanks so much , have been trying to find out from manuals for so long

    • @richardmarlow4466
      @richardmarlow4466 7 месяцев назад

      for winter set mvhr to 25 degress indoor, 10 degrees outdoor

    • @stephencrotty8826
      @stephencrotty8826 7 месяцев назад

      @@richardmarlow4466thanks so much , appreciate you getting back to me !

  • @liamcarr2001
    @liamcarr2001 9 месяцев назад

    We have an identical machine. Probably the same. We are setting it up. But it's stuck on 2 menus. The time and normal air flow screens. You can manually boost it as well. That's it. Cannot get the other options you have here.

  • @adriankaminski6639
    @adriankaminski6639 11 месяцев назад

    Question to anyone who has one. I got mine instaled yesterday. Do all of them make a noise in the rooms? The 40 precent its minimum and i feel like its bit strong

  • @pgmgdaniel
    @pgmgdaniel 11 месяцев назад

    Great video! We have just moved to a new flat and we had no idea on how to set this up!!! Thanks mate

  • @sourabhigiri7035
    @sourabhigiri7035 11 месяцев назад

    How do you open the machine to clean the filters?

    • @richardmarlow4466
      @richardmarlow4466 7 месяцев назад

      sometimes the filter access flaps can be stubborn to open, use a butter knife and gently prise them open.

  • @Msuprewicz
    @Msuprewicz Год назад

    Thanks for the video, how would I ensure maximum coolness during the summer? Please kindly confirm the settings required, I would really appreciate this advice! Thanks 😊

    • @Msuprewicz
      @Msuprewicz Год назад

      It gets very very hot in the evenings!

  • @Tokaisho1
    @Tokaisho1 Год назад

    This helped me set up my own, thanks

  • @rvyas246
    @rvyas246 Год назад

    After 10 years of no issues, my vent axia has started to make a lot of noise. We had it serviced 2 months ago and filters changed, but no improvement. How can we get rid of this noise?

    • @richardmarlow4466
      @richardmarlow4466 7 месяцев назад

      check the atmosphere terminals are not clogged up and check if any debris is fouling the impellers.

  • @mersas32
    @mersas32 Год назад

    I cant find this condensing trap. Any part number would help

    • @NickLaslett
      @NickLaslett 9 месяцев назад

      Hepvo Waste Valve 32mm White Catalog code: BV1 WH

  • @danwelch1079
    @danwelch1079 Год назад

    why is there no sound?

  • @neilbridgeman7768
    @neilbridgeman7768 Год назад

    Really helpful. Thanks.

  • @sambill
    @sambill Год назад

    Would this unit help reduce temperatures during the summer? What temperature should i set it to?

    • @joenetje
      @joenetje Год назад

      No, you have a summer mode but its runs very high and does not work 🤷🏻‍♂️

  • @Damian-fz5nx
    @Damian-fz5nx Год назад

    How to unlock this ? I put 3 digit password and I don't have access now to main menu

  • @andrewinfalmouth
    @andrewinfalmouth Год назад

    Thanks for the video @richard. Any advice on a unit that stays in boost for hrs after the humidity sensors gets set off? It has been working all winter fine since it’s install new. Thanks

  • @darcycollins3023
    @darcycollins3023 Год назад

    My machine seems to be stuck on boost mode 50% and won’t change to normal airflow? Set the overrun to 5 mins like you suggested but still stuck! Initiating boost by clicking the home snowflake button only gives me the option to run a boost 1s. Then after that it’s finished, it returns to boost 50%? Any tips!

    • @arturaskalniunas2748
      @arturaskalniunas2748 Год назад

      I have the same problem. In my case it’s on 65%. Did you manage to sort it?

    • @richardmarlow4466
      @richardmarlow4466 7 месяцев назад

      the switch live cable could be wired to the live cable st the spur, also the humidity setting is too low

  • @SaqibSheikh
    @SaqibSheikh Год назад

    I have this in my flat. Still have no idea what it does or how to work it

  • @fernandogomezlopez7682
    @fernandogomezlopez7682 Год назад

    Hello, how do you do to modify for example all the day at 15% low flow rate ? For the moment the normal flow rate is 30%. This is not well explained in the manual mode. Thanks

  • @vitaliegribincea
    @vitaliegribincea Год назад

    Thank you!

  • @alincioaba464
    @alincioaba464 Год назад

    How can i see the extract temperature and the provide temperature? Does it have such sensors?

  • @claudiapifferi9043
    @claudiapifferi9043 Год назад

    Hi, sorry I'm being a bit thick. During the winter season, what temperatures do I need to set to guarantee enough warmth in the apartment? Would Indoor = 20° and outdoor= 20° work? Thanks I'm new to this and the current temperature is 16° everywhere even with the heating turned on.

  • @untouchboy
    @untouchboy Год назад

    I have exactly same moulde now its stuck fan not working on the screen shows CONTROL MODE FAN OFF

  • @deejy232
    @deejy232 Год назад

    Hi Richard. If I was in a hotel room and I wanted to turn the fan noise off, which setting on the control panel could I use? Hypothetically speaking

    • @richardmarlow4466
      @richardmarlow4466 Год назад

      Initiate control mode 2 which means installing a link across SW5 Then set your low fan speeds to 15%. This will give you manual control of the low user setting. Its important the machine isnt turned off.

  • @DJMambomagic
    @DJMambomagic Год назад

    Hi Richard, can you give me some details on the heating cooling coil you have installed, is this using the mvhr to move the air? Is it effective? Cheers

    • @richardmarlow4466
      @richardmarlow4466 Год назад

      veab.com/kategori/duct-heaters-cooler-water?lang=en Effective as the primary heating in good retrofits that have small peak heat loads. In most situations a good suplementary heating option that is super fast also gives the ability to cool. Between 2kw and 4kw capacity depending on air exchange rate and flow temps.

  • @Conorooney
    @Conorooney Год назад

    What is the "sweet spot" and why that figure? I can't make head nor tail out of P10 of the manual here: www.vent-axia.com/sites/default/files/439817_ad.pdf

  • @gamingguru5569
    @gamingguru5569 Год назад

    i want to learn this software how can i learn this? can you help me

  • @joparish1037
    @joparish1037 Год назад

    Have a similarly-sized set up, but different brands - Vaillant ASHP and Zehnder MVHR. Airtightness test was 2% off Passive Haus standard. August electricity bill was £6! 👍

  • @mateogomez-randulfe7394
    @mateogomez-randulfe7394 Год назад

    how do you turn the vent off?

  • @Castanik
    @Castanik 2 года назад

    Hi! I was wondering if you could tell me how loud the machine would be, in the same room as you? Planning on ghetto rigging one which would have the option of in my hallway outside our bedroom or inside our bedroom. We have a 55sqm apartment, so I figure we could get the 350 sentinel advance, and keep it always in low mode (to futureproof for moving in the future). Would it be possible to sleep in the same room as one on low mode? We are used to the sound of an oscillating fan on the lowest setting at the moment

    • @Tokaisho1
      @Tokaisho1 Год назад

      You can fit a cabinet for it (Like a kitchen cabinet) for the smaller Vent axias, then stick sound deadening to the inside of the cabinet and door.

  • @rayc254
    @rayc254 2 года назад

    So helpful! Thank you

  • @gerardshannon4008
    @gerardshannon4008 2 года назад

    In the bathroom, there is condensation for a number of hours after a shower, how do I address this with the HRV? The humidity is set at 65%. Any help would be appreciated

  • @matthewmascord591
    @matthewmascord591 2 года назад

    It looks like there is a small gap above the control panel. Ours seems to have this too since the engineers refitted the front panel. Is this normal with this unit?

  • @jasonpraful
    @jasonpraful 2 года назад

    Super helpful guide, navigating through the manual was hard. This video was concise, covered everything in the manual