How to wire 3phase 30 Amp disconnect
this video illustrates how to wire up a 30 Amp disconnect. please be sure to turn off all power before you get started.
Просмотров: 2 058

Видео

How to test and reset a GFCI outlet
Просмотров 273Год назад
This video explains how to test and reset a GFCI outlet. The video also explains the purpose of GFCI outlets.
How to reset a tripped curcuit breaker.
Просмотров 91Год назад
This video explains how to reset a tripped circuit breaker. If you have lights or outlets in your house that suddenly stop working, it is most likely due to a tripped circuit breaker. Learn how to reset a tripped curcuit breaker.
How to pull wire for a single pole switch.
Просмотров 4863 года назад
This video explains how to pull wire, particularly non metallic sheathing cable, for a single pole switch. The video explains the 2 different ways that this can be done. The video also explains how to install a single pole switch.
How to install a 3 wire range outlet.
Просмотров 121 тыс.4 года назад
This video explains how to install a 50amp 3 wire range outlet.
How to install a plug for an extension cord
Просмотров 1,6 тыс.4 года назад
This video explains how to install a plug on the end of an extension cord.
How to install a 4 prong range cord
Просмотров 13 тыс.4 года назад
This video explains how to install a 4 prong range cord.
How to install a 3 prong range cord
Просмотров 5 тыс.4 года назад
This video explains how to install a 3 prong range cord for a stove or a range.
How to install a 3wire 30amp dryer outlet
Просмотров 304 тыс.4 года назад
This video explains how to install a 3wire 30 dryer outlet ( specifically in residential, using romex in a plastic box.)
How to install a 2 lamp ballast ( for T5 lamps)
Просмотров 10 тыс.4 года назад
This video explains how to replace and install a 2 lamp ballast, specifically for type T5 lamps.
HOW TO INSTALL A 4WIRE 30 amp DRYER OUTLET
Просмотров 17 тыс.4 года назад
This video explains how to install a 4wire dryer outlet. It informs the viewers that the wire size, and where and how to terminate each of the 4 wires.
How to install a 4 way switch
Просмотров 5804 года назад
This video explain how to install a 4 way switch in a circuit that is wired using romax cable.
How to install a 3way switch
Просмотров 1624 года назад
This video explains how to install a 3 way switch, particularly in a house that is wired in romax. It specifically shows where each wire lands.
How to wire 3way switches using romex cable.
Просмотров 2,3 тыс.4 года назад
In this video, I explain how to wire a set of 3way switches using romex cable ( I explain one way it can be done). There a different way you can do it. The video also talks about where 3ways are normally located and where they are needed.
How to use and read a receptacle outlet tester
Просмотров 53 тыс.4 года назад
This video explains how to use, read, understand and troubleshoot using an receptacle outlet tester.
Determine the circuit color in a 3phase panel (divide by 6)
Просмотров 10 тыс.5 лет назад
Determine the circuit color in a 3phase panel (divide by 6)
How to install an A. C. Disconnect
Просмотров 307 тыс.5 лет назад
How to install an A. C. Disconnect
How to install a dimmer
Просмотров 937 лет назад
How to install a dimmer
Pushing or Pulling mc cable through metal studs
Просмотров 19 тыс.7 лет назад
Pushing or Pulling mc cable through metal studs
Explaining a parallel circuit
Просмотров 957 лет назад
Explaining a parallel circuit
How to install a 120volt GFCI outlet and install a regular outlet on the load side of the GFCI
Просмотров 5097 лет назад
How to install a 120volt GFCI outlet and install a regular outlet on the load side of the GFCI
EXPLAINING A SERIES CIRCUIT
Просмотров 717 лет назад
EXPLAINING A SERIES CIRCUIT
How to install a 120volt receptacle outlet
Просмотров 1067 лет назад
How to install a 120volt receptacle outlet
HOW TO INSTALL A SINGLE POLE SWITCH IN A PLASTIC BOX
Просмотров 1,7 тыс.7 лет назад
HOW TO INSTALL A SINGLE POLE SWITCH IN A PLASTIC BOX
HOW TO PERFORM AN ELECTRICAL 3 POINT TEST
Просмотров 3,8 тыс.7 лет назад
HOW TO PERFORM AN ELECTRICAL 3 POINT TEST
HOW TO USE AN OHM'S LAW CIRCLE CHART
Просмотров 3,8 тыс.7 лет назад
HOW TO USE AN OHM'S LAW CIRCLE CHART

Комментарии

  • @jasonwildbunch
    @jasonwildbunch 2 дня назад

    Thanks bud it helped

  • @mariehailey6738
    @mariehailey6738 6 дней назад

    Thank you, thank you, thank you!

  • @caidiaz9454
    @caidiaz9454 7 дней назад

    Thank you sir.

  • @user-zj1ms4fp5r
    @user-zj1ms4fp5r 9 дней назад

    Great Video for all level in installing an AC Disconnect

  • @AyhamMubeen
    @AyhamMubeen 10 дней назад

    Great job Brother ❤❤❤❤

  • @davidstellwagen1073
    @davidstellwagen1073 13 дней назад

    Violation of NEC 250.140(B) that allows 3 wire says "... if an equipment grounding conductor is not present in the outlet or junction box...". So that section doesn't apply, you have to use a a four wire receptacle in compliance with 250.140(A), and change the cord per appliance manufacturers instructions.

  • @davidw64us1964
    @davidw64us1964 17 дней назад

    Ty for having this video

  • @luisvega74
    @luisvega74 23 дня назад

    Thank you thank you so much. It helped me a lot. I just moved to a new home with a different outlet on the dryer and appreciate your help. Be grateful and God bless you.

  • @joel5466
    @joel5466 Месяц назад

    It was really helpful!

  • @tutubito08
    @tutubito08 Месяц назад

    Very good and clear explanation. Thanks

  • @richinman7774
    @richinman7774 Месяц назад

    Since it is 240v shouldn't you use 10/2 Romex????? Asking for a friend...

    • @rickyjewett6082
      @rickyjewett6082 Месяц назад

      @@richinman7774 that depends on the amperage size of the equipment. If the amprage size of the equipment is 20 amps or less, you can use size 12 romax.

  • @oodavidyyf8416
    @oodavidyyf8416 Месяц назад

    Nice video but if it was 120v. How would that wire to the box.

  • @parkerjohnson5420
    @parkerjohnson5420 Месяц назад

    Should wrap your white wire with some red tape to signify 240. I think that’s code.

    • @rickyjewett6082
      @rickyjewett6082 Месяц назад

      @parkerjohnson5420 yes. That is true. Thank you.

  • @parkerjohnson5420
    @parkerjohnson5420 Месяц назад

    Birds in cars?!?!😱

  • @masterk5066
    @masterk5066 Месяц назад

    Gotta be a fuse or something I hope 😭. So I have 7-8 outlets all reading Open Hot top & bottom except One of the outlets the bottom one works but the top one stopped working as well last year open hot. Trips everytime I plug my computer or treadmill up in bedroom too…..wanna throw the whole breaker away outdoor outlets dead too smh

  • @Mandy357
    @Mandy357 Месяц назад

    Outstanding video, so much covered in a clear and straight forward manner. Thank you, sir.

  • @juniormedina9282
    @juniormedina9282 Месяц назад

    Can I use this on a 20amp breaker double pole 12k btu with a 10/2 bcoz my service panel is about 30ft distance. Or should I I use the fused kind.

    • @rickyjewett6082
      @rickyjewett6082 Месяц назад

      You can use this one in the video or you can use the fuse dis connect. Either will be fine.

    • @juniormedina9282
      @juniormedina9282 Месяц назад

      @@rickyjewett6082 can I use the 30amp fuse disconnect with a 15amp fuse bcoz that what it says on the nameplate of my mini split unit

  • @user-hi8vm6gg9n
    @user-hi8vm6gg9n Месяц назад

    When i tighten down the screw, it doesn't hold fit the wire. The wire still pops out. Any tips how to deal with it 8:44

  • @marioobispo2576
    @marioobispo2576 2 месяца назад

    But I’m still not understanding why we divide the circuit number by 6? Someone please help

  • @zu1502
    @zu1502 2 месяца назад

    So for a 120 v where do I put the neutral wire on each side ?

  • @cleetisap
    @cleetisap 2 месяца назад

    Great video! Thanks for sharing this.

  • @zu1502
    @zu1502 2 месяца назад

    Can a quick disconnect be installed inside for a mini split AC unit ?

  • @fouglasdir
    @fouglasdir 2 месяца назад

    Excellent video! Thanks, I'm ready to do it.

  • @OMG3Dmax
    @OMG3Dmax 2 месяца назад

    good lesson!

  • @royaltoadclub8322
    @royaltoadclub8322 2 месяца назад

    Fantastic video. I've watched like 10 videos on the same thing and learned nothing until this one.

  • @nw4827
    @nw4827 2 месяца назад

    Hell yeah brother 👍

  • @StangTime75
    @StangTime75 2 месяца назад

    Ricky should be an instructor at a trade school. Very clear instructions.

  • @I_name_All_my_guns
    @I_name_All_my_guns 2 месяца назад

    Thank you. Liked and subscribed. I look forward to watching more of your videos

  • @kalelSRB
    @kalelSRB 2 месяца назад

    thank you for this information

  • @racing7m
    @racing7m 2 месяца назад

    Good video man

  • @keithshuler6703
    @keithshuler6703 2 месяца назад

    Thx boss man. I should turn off the breaker switch first, right?

  • @mariagallegos1164
    @mariagallegos1164 2 месяца назад

    Thank you very much

  • @WorldHayes-VR
    @WorldHayes-VR 2 месяца назад

    I have a older house that use old breaker box that use fuses my dryer cord is not pulling enough voltage im getting a code 9c1. Do i install a new plug or is it the breaker box?

    • @rickyjewett6082
      @rickyjewett6082 2 месяца назад

      It could be a fuse blown in your box Also could be your outlet. I would suggest that you change out and install a new plug.

  • @juancho8522
    @juancho8522 2 месяца назад

    Thanks brother.

  • @solarflare8806
    @solarflare8806 2 месяца назад

    Thank you sir!

  • @t.a.3813
    @t.a.3813 2 месяца назад

    This is the only video that explained it to where I understand the line and the load, and 240 vs. 120 and where everything should land properly and to read the directions of course. Thank you.

  • @RockMe1977
    @RockMe1977 3 месяца назад

    God bless your heart Ricky what a perfect demonstration and now i know my landlord sabotaged me. 🕊️ The truth shall set you free and you just did. I hope something wonderful happens to you for helping me 🌹

  • @tony1959rams
    @tony1959rams 3 месяца назад

    Nice refresher training video for a old man that hasn't done one in a long time. Thanks

  • @Dav777
    @Dav777 3 месяца назад

    Thank you so much for doing this video. You're a life saver.

  • @tomclark6742
    @tomclark6742 3 месяца назад

    The bare copper wire should be wired to the silver base of outlet with a clip for this type of outlet.

  • @denyalmccoy8725
    @denyalmccoy8725 3 месяца назад

    What if you have black,white,and ground could still hook it up?

    • @rickyjewett6082
      @rickyjewett6082 3 месяца назад

      Yes you can. Use the white as a hot wire, use the black as a hot wire, and use your ground as your neutral wire. So put the black under one of the hot screws, put the white under the other hot screw and put the ground where the neutral would go.

  • @agentblack3090
    @agentblack3090 3 месяца назад

    Thank you. This help me a lot!

  • @merllhagard6799
    @merllhagard6799 3 месяца назад

    The Romex feeder on your condensing unit needs to be protected. This video is wrong in so many ways. 😂

  • @merllhagard6799
    @merllhagard6799 3 месяца назад

    This video demonstrates exactly why it's important to have a licensed technician perform this work. This bloke has no idea what the hell he's talking about.

  • @merllhagard6799
    @merllhagard6799 3 месяца назад

    12 Gauge wire for a residential cooling system??? Let's all pray for this customer...

  • @user-kd1fh7rn1v
    @user-kd1fh7rn1v 4 месяца назад

    Is there no grounding terminal on these plugs?

    • @rickyjewett6082
      @rickyjewett6082 4 месяца назад

      No, there is no ground terminal on this plug. The dryer will be grounded through the neutral wire.

  • @brandiestreet6347
    @brandiestreet6347 4 месяца назад

    This video was so helpful thank you did tons of research and couldn't find a single one this actully worked and went well so far

  • @stevemann6576
    @stevemann6576 4 месяца назад

    What I *don't* get is why the single pin of the receptacle goes in the lowest position when the plug on the power cable will have it at the apex of the triangle opposite where the cord is attached, making the plug need to be inserted "upside down". Also, with the two pins at the top, any cross-pin contact while pulling or inserting the plug is a 220 v experience, when it would be half that if the neutral was at the top. It makes no sense to me. Just installed one of these and came looking to double check I had it "right".

  • @nealbj3224
    @nealbj3224 4 месяца назад

    This video is exactly why people can't assume that everything on RUclips is correct! What in the world 😮

  • @rinalyn32
    @rinalyn32 4 месяца назад

    The ground being just chillen in the box makes me nervous.. is it really ok to do? I live in a trailer and am terrified of doing it wrong

    • @rickyjewett6082
      @rickyjewett6082 4 месяца назад

      It is totally OK to just leave the ground in the box. Be sure to push it to the back of the box. It OK. It's safe.